Loading...
HomeMy WebLinkAboutConstruction Plansi FBC APPROVED PRODUCTS LIST I PRODUCT CATEGORY I SUBCATEGORY I MANUFACTURER MAXIMUM ALLOWABLE WIND SPEED APPROVAL OA EXPIRATION PARTIALLY No.& DATE DATE OPEN ENCLOSED ENCLOSED FL6596 1 R5 04/05127 180r 180 "1180 10/10/17 --�z TABLE 1 RAFTER FRAME, END POST, GROUND ANCHOR AND PANEL FASTENER SPACING SPECIFICATIONS AVERAGE FASTENER SPACING ON -CENTERS ALONG RAFTERS OR MAXIMUM PURLINS, AND POSTS OR GIRTS WIND ULTIMATE NOMINAL POST / RAFTER (INCHES) RISK EXPOSURE WIND SPEED WIND SPEED SPACING INTERIOR END CATEGORY CATEGORY (MPH) (MPH) (FEET) POSTS/RAFTERS POSTS/RAFTERS t_ ,STRUCT '_STRUCTURAL WALL - CAROLINA CARPORT8,ANC. FL6702.1-RR5 03k14/27-- 180 180,- 110 TO 150 89 TO 116 5.0 6 6 `26-Gauge AG`Panel 10/10/17 �� I C �.. K1 5 M1'f- 151 "TO 180 - STRUCTURAL COMPONENTS FLOOD VENT CRAWL SPACE DOOR SYSTEMS, INC. FL29622.1 09/01/20 N/A N/A N/A NOTES: 1. Specifications applicable to 26 gauge metal roof and wall panels fastened directly to 12 or 14 gauge steel tube framing, or 18 16x8 Flood Vent 05/15/19 gauge hat channel roof purlins. EXTERIOR DOORS SWINGING ELIXIR DOOR AND METAL COMPANY FL 3 R1 09/14/20 N/A 139 138 2. Specifications applicable only for mean roof height of 20 feet or less, and roof slopes of 7° to 27` (1.5:12 to 6:12 pitch). Spacing Series 402-14 01/29/18 requirements for other roof heights and/or slopes may vary. - GROUND ANCHOR SCHEDULE _ EXTERIOR DOORS SWINGING ELIXIR DOOR AND METAL COMPANY FL17996.5-R1 09/14/20 N/A 165 147 ULTIMATE WIND SPEED h m METAL CARPORT INSTALLATION PLANS Series 407 01/29/18 P) 110 120 130 140 150 160 170 180 AND DETAILS AND FRAMING AND EXTERIOR DOORS ROLL -UP ASTA INDUSTRIES INC. FL8888.1-R5 12/31/20 N/A 180 174 FASTENER SPECIFICATIONS Model 203 (12' Max. Width) 10/07/17 12 EXTERIOR DOORS ROLL -UP CAROLINA CARPORTS, INC. FL16806.1-R4 11/11/20 N/A 158 138 14 30"Anchor DetaB 1D FOR CONSTRUCTION IN THE STATE OF FLORIDA Steel Roll Up Sheet Door (12' Max. Width) 06/18/19 � 16 „ ;WINDOWS SINGLE HUNG MI WINDOWS ANO DOORS' FL1.7499,1-'R5'''' 10/17l23 NSA : r. 1.75 i " 157 = 18 PREPARED FOR: Model 185=SH —0312-7/19 - - �• 20 48°Anchor CAROLINA CARPORTS, INC. P.O. BOX 1263 EXTERIOR DOORS ROLL -UP CAROLINA CARPORTS, INC. FL16806.2-R4 11/11/20 N!A 180 180 22 Deta�11C DOBSON, NORTH CAROLINA 27017 Steel Roll -Up Sheet Door - 8' Wide 06/18/19 p 24 EXTERIOR DOORS ROLL -UP - CAROLINA CARPORTS, INC. FL16806.4-R4 11/11/20 N/A 180 172 m 26 PREPARED BY. - BECHTOL. ENGINEERING AND TESTING, INC. Steel Roll -Up Sheet Door -10' Wide 06/18/19 28 60' Anchor 605 WEST NEW YORK AVENUE EXTERIOR DOORS ROLL -UP CAROLINA CARPORTS, INC. FL16806.3-R4 11/11/20 N/A 155 133 30 Deta11C DELAND, FLORIDA 32720 Steel Roll -Up Sheet Door -16' Wide 06/18/19 Certificate of Authorization No. 00005492 DETAILS 1C AND 1D SHOWN ON SHEET 4 OF 6 NOTES: 1 DOORS AND WINDOWS SHOWN MAY BE SUBSTITUTED FOR DIFFERENT PRODUCT LINES AND/OR MODELS, PROVIDED THE FOLLOWING CONDITIONS ARE MET REVIEW ®®fl A PRODUCT SHALL HAVE A VALID FBC PRODUCT APPROVAL B COMPONENTS ARE INSTALLED ACCORDING TO MANUFACTURERS INSTALLATION REOURIEMENTS CODE COMPLIANCE 2 FRAMING CONNECTIONS FOR DOOR AND WINDOW FRAMES REMAIN THE SAME FOR SUBSTITUTED PRODUCTS HEADERS AND WINDOW RAILS MAY BE RAISED OR LOWERED AS NECESSARY TO ACCOMODATE C E COUNTY SUBSTITUTED PRODUCT. ST o LV GENERAL NOTES' B®CC 20�'l - C�G7 1. THESE _PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO THIS IS TO CERTIFY THAT THE CALCULATIONS AND PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET -BACKS, FINISH FLOOR ELEVATION AND SLOPE, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS. SPECIFICATIONS HEREIN HAVE BEEN PREPARED BY THE 2.. THESE STRUCTURES',AfAE DESIGNED AS NON -HABITABLE UTILITY/STORAGE BUILDINGS (RISK CATEGORY I) CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS UNDERSIGNED PROFESSIONAL ENGINEER, AND ARE IN ACCORDANCE WITH THE REQUIREMENTS SECTION 1609 OF NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS, OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS LIST (THIS SHEET), AND NOT PROVIDED AND INSTALLED BY CAROLINA CARPORTS, . ) THE FLORIDA BUILDING CODE, SIXTH EDITION (2017). THE PLANS A INC., WHICH EXERT ADDITIONAL, LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S RISK. BECHTOL ENGINEERING AND TESTING, INC., SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE ARE VALID UNTIL THE NEXT REVISION OF THE FLORIDA BUILDING APPLICATION OF ADDITIONAL LOADS. CODE. 3. ALL STEEL TUBING SHALL BE 50 KSI GALVANIZED STEEL. ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL. ```1lFtiRl1//// R H BEC \ \��� 4. ALL COMPONENTS AND CLADDING SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND SHALL MEET THE DESIGN PRESSURES REQUIRED BY THE FLORIDA BUILDING CODE (FBC) AT THE LOCATION OF THE BUILDING WITHIN THE STATE OF FLORIDA. EECHTOL. ENGINEERING TE ING, INC. % ALL FIELD FRAMING CONNECTIONS SHALL BE #12-14 3/4" SELF DRILLING 605 WEST NEW YORK AVENU: ° E DELAND, FLORIDA 32720 5. x SCREWS WITHOUT CONTROL SEAL WASHER. ALL SHOP FRAMING CONNECTIONS SHALL BE WELDED. _ 140. Certillim" of No. 6_ CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS. THE REINFORCING STEEL SHALL BE MINIMUM GRADE 40. CONCRETE SLAB FOUNDATIONS SHALL BE REINFORCED WITH 6X6-W1 AXW1 .4 a LL1 _ WELDED WIRE FABRIC COMPLYING WITH ASTM A 185, OR WITH SYNTHETIC FIBER REINFORCEMENT COMPLYING WITH ASTM C1116. . (V 7. BASE RAIL GROUND ANCHOR REQUIREMENTS: ONE WITHIN 6" OF EVERY POST LOCATION, AND BOTH SIDES OF OPENINGS WHERE BASE RAIL IS ABSENT. GROUND ANCHORS ARE NOT REQUIRED FOR CONCRETE FOOTING Tfldf ,P.E. Florida i°�•'° AND/OR CONCRETE SLAB CONSTRUCTION. SEE GROUND ANCHOR SCHEDULE (THIS SHEET) FOR SPECIFIC TYPE GROUND ANCHOR REQUIREMENTS. ° F 8. CONCRETE ANCHORS SHALL BE TAPCON REDHEAD LDT 1/2" x 5" OR EQUIVALENT OR WEJ-IT ANKR-TITE MODEL AT1252, OR SLEEVE ANCHOR MODEL HSA 1260, OR EQUIVALENT. �// Ssi OBI PN'V\�\\\ . ///llllllll�� 9. POST/RAFTER BRACING: BRACE ON EVERY POST/RAFTER CONNECTION, EXCEPT FOR END WALLS. FOUNDATION SUBGRADE SOILS SHALL BE TERMITE TREATED AND COVERED WITH 6 VAPOR RETARDER PER SECTION R318.1 OF THE FBC SIXTH EDITION (2017) -RESIDENTIAL, AND SECTION 1816.1 OF THE FBC SIXTH 10 SLAEDIITION AR®®RTS9 SL (20117) BUILDING. MINIMUM ALLOWABLE FOUNDATION SOIL CONTACT BEARING PRESURE OF 2,000 PS FIS ASSUMED. CAROLINA CARPORTS, INC. 11. 14 GA FRAMING: 2-1/2" x 2-1/2" TUBE STEEL (TS) WITH 2-1/4" x 2-1/4" TS NIPPLES. GENERIC PLANS FOR USE IN THE STATE OF FLORIDA 12 GA FRAMING: 2-1/4" x 2-1/4" TS WITH 2" x 2" TS NIPPLES. - 12. ENCLOSED AREAS REQUIRING FLOOD OPENINGS MUST HAVE A MINIMUM OF TWO (2) OPENINGS ON EXTERIOR WALLS. OPENINGS SHOULD BE INSTALLED ON AT LEAST TWO (2) SIDES OF ENCLOSED AREA, WITH BASE OF BECHTOL ENGINEERfNG °�'" Ikti ° NTS OPENINGS SET WITHIN 1-FOOT OF THE HIGHER OF INTERIOR OR EXTERIOR GRADE. REQUIRED TOTAL NUMBER OF FLOOD VENTS NOTED IN THE FBC APPROVED PRODUCTS LIST SHALL BE BASED ON ONE (1) FLOOD VENT PER'�"� G20o0t EVERY 305 SQUARE FEET OF ENCLOSED AREA. SEE TYPICAL FLOOD VENT FRAMING PLAN, SHEET 5 OF 6. boe�roi3r o�eru dwe�fA4 w�TE r Deam,a ama"owrv�rm.� -TB SHEET 1 OF 6 BONY FRAME RAFTER OPEN CARPORT - HORIZONTAL ROOF BOW FRAME RAFTER ENCLOSED BUILDING - HORIZONTAL ROOF BOW FRAME RAFTER. UTILITY BUILDING - HORIZONTAL ROOF FLOOD VENT (As applicable) ROLL -UP DOOR SWINGING DOOR ROLL -UP DOOR SWINGING DOOR (As applicable) (As applicable) (As applicable) (As applicable) _- = ENCLOSED LENGTH VARIES TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE BOX EAVE FRAME RAFTER OPEN CARPORT - HORIZONTAL ROOF BOX EAVE FLAME RAFTER ENCLOSED BLDG - HORIZONTAL ROOF BOX .EAVE FRAME RAFTER UTILITY BLDG - HORIZONTAL ROOF FLOOD VENT (As applicable) ROLL -UP DOOR SWINGING DOOR ROLL -UP DOOR SWINGING DOOR (As applicable) (As applicable) (As applicable)— (As applicable) -- ENCLOSED LENGTH VARIES r - .- TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE 1 BOX EAVE FRAME RAFTER OPEN CARPORT - VERTICAL ROOF BOX EAVE FRAME RAFTER ENCLOSED BLDG - VERTICAL ROOF BOX EAVE FRAME RAFTER UTILITY BLDG - VERTICAL ROOF FLOOD VENT (As applicable) ROLL -UP DOOR SWINGING DOOR ROLL -UP DOOR SWINGING DOOR i (As applicable) (As applicable) (As applicable) (As applicable) r' {I eg •� - -- EN LO ED NGTH VARIES- - - - , TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION — — —` TYPICAL SIDE ELEVATION TYPICAL END ELEVATION NOT TO SCALE NOT TO SCALE NOT TO SCALE / NOT TO SCALE ��� 8.�sQ t NOT TO SCALE NOT TO SCALE J ? < " BECHTOL ENGINEERiN ON 0 TESTING, G. WEST •: 6W NEW YORK AVENUE NO, 385 — DELAND,FLORIDA 32720 — _ Celtlfit�t®of A N � � , ThwrtssP.E. �i�i�•FLOR\�P' �\�� CAROLINA. CARPOktg9'I l\C. GENERIC PLANS FOR USE IN THE STATE OF FLORIDA TYPICAL BOW RAFTER GABLE END ELEVATION TYPICAL BOX EAVE RAFTER GABLE END ELEVATION TYPICAL BOX EAVE RAFTER GABLE END ELEVATION 01/20/20 NOT TO SCALE NOT TO SCALE NOT TO SCALE BECHTOL ENGINEERING AND TEIRMA 0 mkb w"� `NTs tb m"� G20001 oo®aiio �mcay.at.om�exrn�.umw_ iemntEswa e�s3®m TB SHEET 2OF6 26 GA. GALVANIZED METAL ROOF PANELS FASTENED TO RAFTERS PER MANUFACTURER'S INSTALLATION INSTRUCTIONS 12 Q3 7FASTENED -CHANNEL BRACE TO RAFTER WITH 3/4' SDF's AT EACH END (4 PER BRACE) 24' MAXIMUM RAFTER SPAN ON SINGLE RAFTER -24' TO 30' RAFTER SPAN REQUIRES A TRUSSED RAFTER TYPICAL INTERIOR RAFTER/POST FRAME SECTION - BOW FRAME NOT TO SCALE 0 LENGTH VARIES DEPENDING ON SEE TABLE 1 SHEET 1 OF 6 26 GA. GALVANIZED METAL ROOF PANELS FASTENED TO RAFTERS PER MANUFACTURER'S INSTALLATION INSTRUCTIONS 2 12 4 �3 24" 16 GA U-CHANNEL BRACE FASTENED TO RAFTER WITH (2) #12-14 x 3/4' SDFs AT = EACH END (4 PER BRACE) W J "v 24 MAXIMUM RAFTER SPAN ON SINGLE RAFTER >24 TO NY RAFTER SPAN REQUIRES A TRUSSED RAFTER TYPICAL INTERIOR RAFTER/POST FRAME SECTION - BOX EAVE - HORIZONTAL ROOF NOT TO SCALE LENGTH VARIES DEPENDING ON ,"FAGINU Ur SEE II TABLE 1 SHE ET1 nr a , TYPICAL RAFTER/POST FRAMING PLAN - BOW FRAME TYPICAL RAFTER/POST FRAMING PLAN - BOX EAVE NOT TO SCALE NOT TO SCALE i SEE SEE TABLET TABLE 1 OPENING FOR SWINGING SHEET SHEET DOOR WITH NON-STRUCTURAL T 1 OF 6 1 OF 6 HEADER ref n I I 12' MAX. OPENING FOR ROLL -UP DOOR WITH STRUCTURAL HEADER 10" (TYPICAL) \/ \_X_/ OPENING FOR WINDOW WITH \ NON-STRUCTURAL HEADER TYPICAL SIDE WALL OPENINGS FRAMING PLAN AND WINDOW RAIL (Also applicable to End Wails) NOT TO SCALE LD S OPTIONAL 24'-9" TO 30' TRUSSED RAFTER - BOW 11 CpwruicR S'AV GNG UOCR 12' MAX. OPENING FOR II I xrzx k'•+: STRCTI'4P: ROLL -UP DOOR WITH Ir=„+tea NONSTRUCTURAL �\ HEADER 6' -i 26 GA. GALVANIZED METAL ROOF PANELS FASTENED TO PURLINS PER MANUFACTURER'S INSTALLATION INSTRUCTIONS 1-1/2" 18 GAUGE FURRING CHANNEL (PURLIN) 1 `24' 16 GA U-CHANNEL BRACE J FASTENED TO RAFTER WITH (2) #12-14 x 3/4' SDFs AT EACH END (4 PER BRACE) 24MAXIMUM RAFTER SPAN ON SINGLE RAFTER 124 TO 30' RAFTER SPAN REQUIRES A TRUSSED RAFTER 1-112" 18 GAUGE FURRING CHANNEL FASTENED TO EACH RAFTER WITH (2) #12-14 x 3/4' SELF -DRILLING FASTENER SPACED NOT MORE THAN 48' O.C. 3 4 SEE TABLE 1 SHEET 1 OF 6 LENG VARIES DEPENDING ON NUMBER AND SPACING OF RAFTERS r '-I TYPICAL POST/RAFTER FRAMING PLAN - VERTICAL ROOF NOT TO SCALE TYPICAL END WALL OPENINGS POST/RAFTER FRAMING PLAN NOT TO SCALE I& ___\ r-6" WELD ALL WEB CONNECTIONS, BOTH SIDES TYPICAL BOW RAFTER GABLE END FRAMING PLAN NOT TO SCALE EE AXIMUM TABLE SHEET I VERTICAL i M x 3 TYPICAL BOX EAVE RAFTER GABLE END FRAMING PLAN NOT TO SCALE 24" 16 GA U-CHANNEL BRACE FASTENED TO RAFTER WITH (2) #12-14 x 314" SELF -DRILLING SCREWS AT EACH END (4 PER BRACE) ROOF EXTENSION OPTION MAIN STRUCTURE STANI TYPICAL LEAN-TO OPTIONS FRAMING PLAN (BOTH OPTIONS S 24" 16 GA U-CHANNEL BRACE (5' To r POST) ECHTOL E NGINEERINra ` 48" 16 GA U-CHANNEL BRACE (8' TO 14' POST) B WEST NEW NGI AVENU�` BRACE ANGLE SHALL BE MIN. 30° DELAND, FLORIDA 32720 TO MAX. 45° FROM HORIZONTAL carltifteta Of FULL 6" WELD _ BOTH SIDES OPTIONAL 24'-l" TO 30' TRUSSED RAFTER - BOX EAVE NOT TO SCALE LEAN-TO OPTION N ,I"IIIII////// F\I E R)j3 tiT i ND' 3853E y elf_ Lli O/U •� STpiE NOT TO SCALE LEAN-TO FRAMING PLAN NOT TO SCALE INSTALL 1/2' x MINIMUM 5" TAPCON REDHEAD LDT ANCHOR OR 1/2' x MINIMUM 5-1/2' EXPANSION ANCHOR THROUGH BASE RAIL WITHIN 6" OF EACH RAFTER POSTS ALONG SIDES AND EVERY END ,WALL POST ALONG END WALL SECTIONS 4" MINIMUM / \ \ -..I �-2" MINIMUM MINIMUM 2-1/2" EMBEDMENT UU•• _ tl j l MONOLITHIC CONC. FOOTING (2500 PSI MIN.) REINFORCED WITH 2 #5's CONTINUOUS G_O!'CRRzIE,BAAER�IAIL ANCHORV' 5 <A 1 Not To Scale DRILL 5/8" HOLE THROUGH THE Al- 2"WASHERS BASE RAIL AND SECURE TO ANCHOR EYE WITH 1/2"DIAMETER TS CONTINUOUS THROUGH -BOLT—\ BASE RAIL (SEE GROUND ANCHOR MINIMUM 4' SCHEDULE, SHEET 1 OF 6, FOR REQUIRED ANCHOR) CONTINUOUS 4' CONCRETE PAVEMENT EYE ANCHOR �1 E � Not To Scale CONCRETE BASE RAIL ANCHORAGE % �/ (OPEN CARPORTS WHERE SLAB EDGE DISTANCE DOES NOT MEET MINIMUM EDGE DISTANCE SHOWN IN DETAIL 1B) TS TRUSSED RAFTER CHORD, OR NON-STRUCTURAL HEADER TS END POST OR DOOR/ / WINDOW FRAME POST .! TS BASEANINDOW RAIL OR NON-STRUCTURAL HEADER 1(12 GA IF ROLL -UP DOOR FRAME) 2"x2"x2' 16 GA ANGLE CLIP SECURE TO POST (EACH SIDE) AND RAFTER CHORD/RAIL WITH (4) #12-14 x 3/4" SDF's, (2) ON TOP OR BOTTOM, (2) ON SIDE NOTE: AT ROLL -UP DOOR OPENINGS, POST SHOULD BE FLUSH WITH RAIL END. CLIP POST TO RAIL ONLY ON SIDE OPPOSITE THE OPENING. POST TO RAIL, TRUSS CHORD, OR NON-STRUCTURAL HEADER CONN. DETAIL Not To Scale INSTALL 1/2" x MINIMUM 5" TAPCON REDHEAD LDT ANCHOR OR 1/2" x MINIMUM 5-1/2" EXPANSION ANCHOR DRILL 5/8" HOLE THROUGH THE 2" WASHERS THROUGH BASE RAIL WITHIN 6" OF EACH BASE RAIL AND SECURE TO RAFTER POSTS ALONG SIDES AND EVERY END ANCHOR EYE WITH 1/2" DIAMETER TS CONTINUOUS WALL POST ALONG END WALL SECTIONS THROUGH -BOLT BASE RAIL F- MIN. 6" TOP OF ASPHALT PAVEMENT OR STABLE GROUND SURFACE MINIMUM 2-1/2" EMBEDMENT MINIMUM 4' CONTINUOUS 4" CONCRETE PAVEMENT , CONCRETE BASE RAIL ANCHORAGE 1 Q B % Not To Scale (OPTIONAL - OPEN CARPORTS ONLY) 24" 16 GA U-CHANNEL BRACE (5' TO T POST) 48' 16 GA U-CHANNEL BRACE (8' TO 14' POST) BRACE ANGLE SHALL BE MIN. 45' TO MAX. 60' FROM HORIZONTAL NIPPLE TO\ 3/16" RAFTER RAFTER 6" LONG TS NIPPLE SECURE POST TO NIPPLE WITH (4) #12-14 x 3/4" SDF's RAFTER POST BOX EAVE RAFTER/POST DETAIL Not To Scale TS RAFTER POST 1-1/2" x 1-112" x 2" 16 GA CLIP ANGLE SECURE TO POST AND BASE RAIL WITH (4) #12-14 x 3/4" SDF's, 4 (2) ON TOP, (2) ON SIDE CONTINUOUS BASE RAIL END POST/BASE RAIL CONN. � Not To Scale EYEANCHOR 5/8" ROD 48" LONG I , WITH 6" HELIX OR 518" ROD 60" LONG (SEE GROUND ANCHOR WITH 7" HELIX, SCHEDULE, SHEET 1 OF 6 AS APPLICABLE — FOR APPLICABILITY) �C BASE RAIL DEEP ANCHORAGE Not To Scale NO SCREWS REQUIRED IN BOW BEND BOW RAFTER r� DRILL 5/8' HOLE THROUGH THE BASE RAIL AND SECURE TO ANCHOR EYE WITH 1/2' DIAMETER THROUGH -BOLT TOP OF ASPHALTPAVEMENT OR STABLE GROUND SURFACE 2" WASHERS TS CONTINUOUS BASE RAIL EYE ANCHOR U (SEE GROUND ANCHOR 518, ROD 30' LONG SCHEDULE, SHEET 1 OF 6 WITH DBL 4" HELIX FOR APPLICABILITY) a BASE RAIL ANCHORAGE 1 V Not To Scale 24" 16 GA U-CHANNEL BRACE (5' TO T POST) 48" 16 GA U-CHANNEL BRACE (8' TO 14' POST) BRACE ANGLE SHALL BE MIN. 45° TO MAX.. 60* FROM HORIZONTAL NIPPLE TO \ 3/16" BASE RAIL / 6" 3" 3• 6" LONG TS NIPPLE SECURE RAFTER AND POST TO NIPPLE WITH (4) #12-14 x 3/4" TS RAFTER POST SELF -DRILLING FASTENERS BOW RAFTER/POST DETAIL Not To Scale TS POST 16 GA ANGLE CLIP 'O POST AND TOP OF :)R BOTTOM OF WINDOW WITH (4) #12-14 x 314" SDF's OR BOTTOM, (2) ON SIDE NON-STRUCTURAL HEADER TS WINDOW RAIL OR GIRT FOR VERTICAL SIDING OPTION NON-STRUCTURAL HEADER, WINDOW 6 . RAIL, OR.GIRT TO POST CONN. DETAIL Not To Scale 6" LONG TS NIPPLE SECURE POST TO NIPPLE WITH (4) #12-14 x 3/4' SDFs TS RAFTER POST TS CONTINUOUS BASE RAIL POST/BASE RAIL CONN. DETAIL � Nol To Scale H. BFc BECHTOL ENIGNOWNG3,66 TESTIN16, j . 605 WEST NEW iIQRKANEWLIE DEMD, FLORIDA�32n0 m No. 3B538 CeNcato of Autlrofizatlon lip.54 _ d 76 Thanes Beelttol P.Ei ° ° STATE OF Florida Lkense No. T ° ft Q R10 • ' /S/ONAI- \\.�• II �2'x2'x2" 16 GA ANGLE CLIP SECURE TO POST AND RAFTER WITH (4) #12-14 x 3/4" SDF's, (2) ON BOTTOM, (2) ON SIDE OR 2'x4" 16 GA PLATE SECURE TO EACH SIDE OF TS END POST POSTIRAFTER CONNECTION WITH (4) #12-14 x 3/4' SDF's, n (2) ON POST, (2) ON RAFTER END POST/RAFTER CONN. DETAIL r Not To Scale 1-1/2" x 1-1/2" x 2" 16 GA CLIP ANGLE SECURE TO RAFTER POST AND GABLE RAIL WITH (4) #12-14 x 3/4" SDF's (2) ON TOP, (2) ON SIDE TS RAFTER POST a 1-1/2" x 1-1/2" x 2' 16 GA CLIP ANGLE SECURE TO RAFTER AND GABLE RAIL WITH (4) #12-14 x 3/4" SDF's, (2) ON TOP, (2) ON BOTTOM TS GABLE RAIL t GABLE RAIL TO RAFTER POST CONNECTION DETAIL 1 I H Not To Scale 2-114" FOR 12 GA FRAMING 2-1/2' FOR 14 GA FRAMING 16 GAUGE U-CHANNEL BRACE FASTENED TO THE POST AND RAFTER WITH (2) #12-14 x 3/4" SDF'S AT EACH END (4 PER BRACE) - BRACE SECTION Not To Scale NIPPLE DBL. HD -S NIPPLE EACH WITH x 3/4" -LING FASTENERS GA TS POST RAFTER POST/DBL. HEADER DETAIL � Not To Scale 1-1/2" x 1-1/2" x 2" 16 GA CLIP ANGLE SECURE TO RAFTER POST AND GABLE RAIL WITH (4) #12-14 x 3/4" St TOP AND BOTTOM 1-112" x 1-1/2' x 2" 16 GA CLIP ANGLE SECURE TO RAFTER AND GABLE RAIL WITH (4) #12-14 x 3/4" SDFs, (2) ON TOP, (2) ON BOTTOM �6" LONG TS NIPPLE SECURE RAFTER AND POST TS GABLE RAIL TO NIPPLE WITH (4) #12-14 x 314" SELF -DRILLING FASTENERS TS RAFTER POST GABLE RAIL TO RAFTER POST CONNECTION DETAIL r 1 Not To Scale b 1-1/2" 18 GAUGE FURRING CHANNEL FASTENED TO EACH RAFTER WITH (2) #12-14 x 3/4" SDF SPACED NOT MORE THAN 48" O.C. 26 GA. METAL ROOF PANEL TS RAFTER ROOF�EO 1�I(ALTER TR VERTICAL ROOF PANE[ \FTER POST NG TS NIPPLE IRE WITH (4) #12-14 x 3/4" DRILLING FASTENERS DOUBLE TS HEADER NIPPLE TO DBL. HDR. 9 RAFTER POST/HEADER DETAIL Not To Scale NIPPLE TO 3/16" RAFTER TS RAFTER 12" LONG TS NIPPLE. SECURE POST TO NIPPLE WITH (4) #12-14 x 3/4" SOFs, 24" 16 GA U-CHANNEL BRACE (5' TO T POST) 48" 16 GA U-CHANNEL BRACE (8' TO 14' POST) BRACE ANGLE SHALL BE MIN. 4'5" TO MAX. 60' FROM HORIZONTAL TS LEG POST TS RAILS W9-L•N141:701 —6" LONG TS NIPPLE WSECURE WITH (4) #12-14 x 3/4' SDF's �--TS RAFTER POST SIDE EXTENSION RAFTER/POST DETAIL Not To Scale TYPICAL FLOOD VENT FRAMING PLAN NOT TO SCALE SEE GENERAL NOTE No. 12. SHEET 1 OF 6. 6' LONG TS NIPPLE SECURE EACH WITH (4) #12-14 x 3/4" { SELF -DRILLING FASTENERS /-12 GA TS POST TS BASE RAIL c� o' 3116" NIPPLE TO BASE RAIL RAFTER POST/BASTE 0,0 BASE RAIL CONNECTION DETAIL r Not To Scale RAFTER POST 2"x4" 16 GA PLATE (ONE REQUIRED) SECURE TO EITHER SIDE OF POST/RAFTER CONNECTION WITH (4) #12-14 x 3/4" SDFs, (2) ON POST, (2) ON RAFTER _-TS LEAN-TO RAFTER 2"x7x2" 16 GA ANGLE CLIP SECURE TO POST AND RAFTER WITH (4) #12-14 x 3/4" SDF's, (2) ON RAFTER, (2) ON POST POST / LEAN-TO RAFTER CONN. DETAIL r o Not To Scale BECHTOt �NEERING AND TE ,1wC. uF� Do ORlDn-um AVENUE. 38538 Ceruftats of No. _ Trwmes BeusfA6 TE Florida Uce �• • F(ORID P �,��� ////VVV/_11,S77�; 0NAL,����`� ■6 VERTICAL SIDE OP TION SEE TABLE 1 OPENING FOR SWINGING DOOR SHEET `WITH NONSTRUCTURAL HEADER GIRTS 0 (Typical) q a 6 o f 4 'm 12' MAX. OPENING FOR ROLL -UP DOOR WITH 4 q. ON -STRUCTURAL HEADER 4 4 4 A A' TYPICAL END WALL OPENINGS POST/RAFTER/GIRT FRAMING PLAN NOT TO SCALE BOX SAVE FRAME RAFTER ENCLOSED BLDG - VERTICAL SIDES TYPICAL SIDE ELEVATION NOT TO SCALE ROLL -UP DOOR SWINGING DOOR TYPICAL END ELEVATION NOT TO SCALE 0 { 1-1/2" 18 GAUGE FURRING CHANNEL FASTENED TO OPENING FOR SWINGING DOOR EACH RAFTER WITH (2) #12-14 x 314" SELF -DRILLING WITH NON-STRUCTURAL HEADER FASTENER SPACED NOT MORE THAN 48' O.C. GIRTS (Typical) 6 q SEE TABLE 1 SHEET 1 OF 6 8 6 6 3 JOE e 5 12' MAX. OPENING FOR ROLL -UP DOOR WITH STRUCTURALHEADER 4 4 a 5 10 q 3 3 4 q q. g q 5 OPENING FOR WINCOW WRH NONSTRUCTURALHEA�ER LENGTH VARIES DEPENDING ON NUMBER (Also applicable tAND o EW RAIL AND SPACING OF RAFTERS nd Walls) TYPICAL POST/RAFTER/GIRT FRAMING PLAN NOT TO SCALE BOX EAVE FRAME RAFTER UTILITY BLDG - VERTICAL SIDES ROLL -UP DOOR SWINGING DOOR 6• TYPICAL SIDE ELEVATION TYPICAL END ELEVATION NOT TO SCALE NOT TO SCALE BECHTOL EN G NG DTES Nli U . 605 WEST NEW YORR�E DELAND, FLORiD38538 Cerowte of No. — Bwh�P.E`i ATE OF Florida Lisa •. F P \ SS1OW-\\ Il11111\