Loading...
HomeMy WebLinkAbout205048-1d Compaction - signedHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net DATE TESTED:KSM JOB #:205048-1d/SH/jo PERMIT #:NUC #528 CONTRACTOR:Wynne Development Nuc Model:MC-1DR-P JOB LOCATION:4 Cordova Lane Nuc Serial #:MD049528 Spanish Lakes One Port St Lucie, Florida ITEM TESTED:Compacted Foundation Fill TEST LOCATION OF SAMPLE DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE (P.C.F) PERCENT COMPACTION 1. S.W.0" - 12"39 106.8 112.0 95.4% 2. N.W."40 107.3 "95.8% 3. Center "40 107.1 "95.6% 4. N.E."38 106.4 "95.0% 5. S.E."37 106.6 "95.2% Soil Description: Brown Sand In Place Moisture: 9.3% Proctor Optimum Moisture: 11.0% Proctor Max. Dry Density: P.C.F. 112.0 @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets Minimum Requirement for Unstaked Foundation Respectfully Submitted: Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 10/13/2020 Email to: St Lucie Building Department SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 October 12, 2020 20080800 Disclaimer:Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the tested area has been altered from the approved inspected condition. Proudly Serving Florida since 1990 110.0 111.0 112.0 113.0 8 9 10 11 12 13 14 15 W E I G H T P . C . F . D R Y Moisture -% of Dry Weight