HomeMy WebLinkAboutproduct approval (2)—.� -
Regulation
BCIS Home I Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications I FBC Staff BCIS Site Map { Links Search i
Florida
ON
Product Approvalr
USERPublic User
Product Approval Menu > Application Detail
•i FL # FL13339-R5
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived ❑
Product Manufacturer . Attic Breeze
Address/Phone/Email 1370 FM 116
Gatesville, TX 76528
(254)865-9999
travis.hipp@atticbreeie.net
Authorized Signature James Buckner
jimmy@cbuckinc.net
Technical Representative Travis Hipp
Address/Phone/Email 1370 FM 116
Gatesville, TX 76528
(877) 288-4234
trav[s.hipp@atticbreeze.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Roofing Accessories that are an Integral Part of the Roofing System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Ci Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
James L. Buckner, P.E. @ CBUCK Engineering
the Evaluation Report
Florlda License
PE-31242
Quality Assurance Entity
Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date
12/01/2029
Validated By
Michael John Werner, P.E.
I] Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL13339 R5 COI FL13339 R5 COI CertOfIndeo.odf
1709.2
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Date Revised
FL # Model, Number or Name
A, 13339.1 01_Solar Attic Fan
Method 2 Option B
06/14/2017
06/15/2017
06/21/2017
08/08/2017
01/05/2018
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +115/-115
other: Refer to evaluation report for limitations and
conditions of use. Refer to manufacturer's installation
instructions as a supplemental guide.
13339.2 1 02_Solar Attic Fan
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +115/-115
Other: Refer to evaluation report for limitations and
conditions of use. Refer to manufacturer's installation
instructions as a supplemental guide.
13339.3 1 03_Solar Attic Fan
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +115/-115
other: Refer to evaluation report for limitations and
conditions of use. Refer to manufacturer's installation
instructions as a supplemental guide.
13339.4 1 04_Solar Attic Fan
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +115/-115
other: Refer to evaluation report for limitations and
conditions of use. Refer to manufacturer's installation
instructions as a supplemental guide.
Description
Models AB-201A, AB-202A, AB-251A, AB-252A, AB-2022A,
AB-3022A & AB-4022A. Self -flashing, solar powered fan
units, with solar panel directly attached to fan unit
shroud/dome
installation Instructions
FL13339 R5 II 1 Attic Breeze-SPAF Panel Direct to Flush
Mount Unit EvalReport .odf
Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E.
#31242
Created by Independent Third Party: Yes
Evaluation Reports
FL13339 R5 AE 1 Attic Breeze-SPAF Panel Direct to Flush
Mount Unit EvalReport .Ddf
Created by Independent Third Party: Yes
Models AB-201D, AB-202D, AB-251D, AB-252D, AB-401, AB-
402, AB-2022D, AB-3022D & AB-4022D. Self -flashing, solar
powered fan units, with solar panel(s) remotely attached
from fan unit, using low profile mounting brackets
Installation Instructions
F: 13339 R5 II 2 Attic Breeze-SPAF Panel Remote to Low
Profile EvalReport .odf
Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E.
#31242
Created by Independent Third Party: Yes
Evaluation Reports
FL13339 R5 AE 2 Attic Breeze-SPAF Panel Remote to Low
Profile EvalReport .odf
Created by Independent Third Party: Yes
Models AB-201D, AB-202D, AB-251D, AB-252D, AB-401, AB-
402, AB-2022D, AB-3022D & AB-4022D. Self -flashing, solar
powered fan units, with solar panel(s) remotely attached
from fan unit, using universal mounting bracket
Installation Instructions
FL13339 R5 II 3 Attic Breeze-SPAF Panel Remote
Inclined EvalReport .odf
Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E.
#31242
Created by Independent Third Party: Yes
Evaluation Reports
Fi 1 334g R5 AE 3 Attic Breeze-SPAF Panel Remote
Inclined EyalRe op rt .odf
Created by Independent Third Party: Yes
Models AB-601, AB-602 & AB-6022D. Self -flashing, solar
powered fan units, with solar panel remotely attached from
fan unit, using low profile mounting brackets
Installation Instructions
FL13339 R5 II 4 Attic Breeze-SPAF Panel Remote to Low
Profile EvalReport .odf
Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E.
#31242
Created by Independent Third Party: Yes
Evaluation Reports
FL , 333o cc eF a Attic n ze-SPAF Panel Remote to Low
Profile EvalReport .odf
Created by Independent Third Party: Yes
13339.5 05_Solar Attic Fan Models AB-601, AB-602 & AB-6022D. Self -flashing, solar
powered fan units, with solar panel remotely attached from
fan unit, using universal mounting brackets
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL13339 R5 Il 5 Attic Breeze-SPAF Panel Remote
Approved for use outside HVHZ: Yes Inclined EvalReport odf
Impact Resistant: No
Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E.
Design Pressure: +115/-115
#31242
Other: Refer to evaluation report for limitations and
Created by Independent Third Party: Yes
conditions of use. Refer to manufacturer's installation
Evaluation Reports
instructions as a supplemental guide.
FL13339 RS AE 5 Attic Breeze-SPAF Panel Remote
Inclined EvalReport_pdf
Created by Independent Third Party: Yes
13339.6
06_Cardinal Ventilation
Models CV-2000 & CV-3000. Self -flashing, circular shaped
solar powered fan units, with solar panel directly attached to
fan unit hood/dome
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +115/-115
Other: Refer to evaluation report for limitations and
Installation Instructions
FL13339 R5 II 6 AB -Cardinal SPAF Panel Direct to Flush
Mount Unit EvalReport Ddf
Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E.
#31242
Created by Independent Third Party: Yes
conditions of use. Refer to manufacturer's Installation
Evaluation Reports
Instructions as a supplemental guide.
FL13339 R5 AE 6 AS -Cardinal SPAF Panel Direct to Flush
Mount Unit EvalReport .Ddf
Created by Independent Third Party: Yes
13339.7
Curb Mount Series
Curb Profile vent fan base for attachment to roof curbs
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +115/-115
Other: Refer to evaluation report for limitations and
conditions of use.
Installation Instructions
FL13339 R5 II 17-144 2-7 ER Curb Base es.Ddf
Verified By: James L Buckner, P.E. @CBUCK, Inc P.E. #
31242
Created by Independent Third Party: Yes
Evaluation Reports
FL13339 R5 AE 17-144 2-7 ER Curb Base es.Ddf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Cbovriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please
click here .
Product Approval Aeeepte:
MMM 99
Credit Card
Safe
_
SpPCldlft j r= Cucj'ural r=nC; Ir1L=E,rinQ CBUCK, Inc. Certificate of Authorization #8064
Evaluation Report
"Solar Attic Fans"
Self -Flashing Series
with Shroud/Dome Mounted Solar Panel
20 Watts, 30 Watts & 40 Watts Solar Panels
Manufacturer
Attic Breeze, LLC.
1370 FM 116
Gatesville, Texas 76528
(877) 288-4234
for
Florida Product Approval
# FL 13339.1 R6
Florida Building Code 6th Edition (2017)
Per Rule 61G20-3
Method: 2.- B
Category: Roofing
Sub - Category: Roofing Accessories that are an Integral
Part of the Roofing System
Product Name:
Product Description:
Prepared by:
James L. Buckner, P.E., SECS
Florida Professional Engineer # 31242
Florida Evaluation ANE ID: 1916
Report No. 18-101-SPAF-Dir-S4W-ER
Date: 1/4/ 18
Contents:
Evaluation Report Pages 1— 6
Solar Attic Fans
Self -Flashing Series
F csimil of digital copy signed by
with Shroud/Dome Mounted Solar l�anPt es L. Buckner, P.E.
Electronically signed and sealed documents
comply with the provisions of FAC Rule 61G1!
BuC
* ;
* ' No 31242
u
441
��'•, STATE OF
2018.01.04 15:00:37-05'00'
CBUCK, Inc. - Palm Beach County, Florida
Phone: (561) 491-9927 • Email: cbuck@cbuckinc.net • Website: www.cbuckinc.net
Spcecialrtj Structural IEngllnpprinq
Manufacturer: Attic Breeze, LLC.
Product Name: Solar Attic Fans
Product Category: Roofing
FL #: FL 13339.1 R6
Date: 1/4/18
Report No.: 18-.101-SPAF-Dir-S4W-ER
Page 2 of 6
CBUCK, Inc. Certificate of Authorization #8064
Product Sub -Category Roofing Accessories that are an Integral part of the Roofing System
Compliance Method: State Product Approval Rule 61G20-3.005 (2) (b)
Product Description: The Solar Attic Fan is a roof mounted system powered by a solar panel. The unit
consists of a 14 inch diameter fan, enclosed in a self -flashing fan house base vent,
with corrosion resistant, zincalume alloy steel housing, including a thermal switch,
and a rodent guard. The solar panel is attached directly to the fan house unit
shroud/dome.
Product Assembly as Self -flashing solar attic fan with shroud/dome mounted solar panel
Evaluated: - Fan house base unit component mechanically attached to deck with wood
screws.
Model Numbers: No./Designation
AB-201A
AB-202A
AB-251A
AB-252A
AB-2022A
AB-3022A
AB-4022A
Fan Unit Base Support: Type:
Wood Deck
(Design of support system is outside the scope of this evaluation)
Description:
• 15/32" or greater Plywood, or
• Wood plank deck (based on minimum density/specific gravity of 0.42)
Roof Slope: Slope shall be in compliance with FBC, Chapter 15 based on the type of roof covering.
Performance: Allowable Wind Resistance:
* Positive Design Pressure: + 115 PSF
* Negative Design Pressure: -115 PSF
* Allowable design pressures for allowable stress design (ASD).
Lim
FL #: FL 13339.1 R6
Date: 1 / 4 / 18
Report No.: 18-101-SPAF-Dir-S4W-ER
Page 3 of 6
Specialty Strucfi urat Engineering CBUCK, Inc. Certificate of Authorization #18064
Performance Standards: The following test protocol was performed to demonstrate compliance with the
intent of the code as this product does not specifically addressed the performance
standard in the code.
• ASTM E330-02 —Standard Test Method for Structural Performance of Exterior
Windows, Curtain Walls, and Doors and by Uniform Static Air Pressure Difference
Code Compliance: The product described herein has demonstrated compliance with the Florida
Building Code 6th Edition (2017), Section 1708.2.
Evaluation Report Scope: This product evaluation demonstrates compliance of this product with the structural
wind load requirements of the Florida Building Code, as related to Florida Product
Approval Rule 61G20-3.001.
Limits of Use: • The Solar Attic Fan including solar panel and electrical wiring shall be installed in
compliance with Attic Breeze's installation instructions and in accordance with
applicable Building Codes
• Scope of "Limitations and Conditions of Use" for this evaluation:
This evaluation report for "Optional Statewide Approval" contains technical
documentation, specifications and installation method(s) which include
"Limitations and Conditions of Use" throughout the report in accordance with
Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is
the authority to approve products under "Optional Statewide Approval".
• Option for application outside "Limitations and Conditions of Use"
Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific
approvalby the local authorities having jurisdiction in accordance with the
alternate methods and materials authorized in the Code". Any modification of
the product as evaluated in this report and approved by the Florida Building
Commission is outside the scope of this evaluation and will be the responsibility
of others.
• Refer to applicable building code section for ventilation requirements.
• Design of support system is outside the scope of this report.
• Fire Classification is outside the scope of Rule 61G20-3, and is therefore not
included in this evaluation.
• This evaluation report does not evaluate the use of this product for use in the
High Velocity Hurricane Zone code section. (Dade & Broward Counties)
Quality Assurance: The manufacturer has demonstrated compliance of roof vent products in accordance
with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a
quality assurance program audited by an approved quality assurance entity through
Keystone Certification, Inc. (FBC Organization #: QUA 1824)
Specialty Structural Enc1neerinq
Component(s) Solar Attic Fan
Material Standards: - Nominal Dimensions
Fan House Base:
Fan House Shroud/ Dome:
Solar Panel:
Overall Height:
FL #: FL 13339.1 R6
Date: 1 / 4 / 18
Report No.: 18-101-SPAF-Dir-S4W-ER
Page 4 of 6
CBUCK, Inc. Certificate of Authorization #8064
28" x 28"
21-1/2" x 21-1/2"
19-1/4" x 16-1/4"
12"
- Fan House Base & Shroud/Dome Material:
Material: Steel
Thickness: 22 ga.
Yield Strength: 33 ksi Minimum
Corrosion Resistance: Galvalume or Zincalume per ASTM A792 AZ 50
or in compliance with the FBC, Section 1507.4.3.
Fastener
Type:
Size:
Standard:
Corrosion Resistance:
Pancake Head Wood Screw
#10 x 1 in. Minimum
Per ANSI/ASME B18.6.1
Per FBC Section 1506.6
Installation: installation Method:
(Refer to Pages 5 and 6 of this evaluation report.)
"The Solar Attic fans" shall be installed in compliance with the installation method
listed in this report. The installation method described herein is in accordance with
the scope of this evaluation report. Refer to manufacturer's installation instructions
as a supplemental guide for attachment.
Evaluated Referenced Data: 1. ASTM E330-02 Uniform Static Air Pressure Difference Test
By Certified Testing Laboratories, Inc. (FBC Organization ID# TST 1577)
Project #: CTLA 2002W, Dated: 11 / 20 / 09
2. Quality Assurance
By Keystone Certification, Inc. (FBC Organization ID# QUA 1824)
Attic Breeze, LLC. Licensee #740
3. Certification of Independence
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization # AN 1916)
4. Engineering Analysis
By. CBUCK Engineering
Report #C09-194, Dated: 12 / 1 / 09
Report #C16-164, Dated: 10 / 20 / 16
FL #: FL 13339.1 R6
Date: 1 / 4 / 18
CBVCK EngIneering Report No.: 18-101-SPAF-Dir-S4W-ER
Page 5 of 6
.N
SpPGatty Structural Encglnec=rinq LHULK InC. certIfICate Of Authorization #6U64
Installation Method
Attic Breeze, LLC.
Solar Attic Fan Attachment Assembly
Fan House Shroud -
Fan house
#10 x V Pam
Wood Screw
Solar Panel
20" Diameter
Plywood Deck
Typical Opervng
Assembly Front Section View
Solar Panel
2114'
Fan House Shroud
Fan house
Ir 2(Y' Diameter
#10 x 1" Pancake -Head Plywood Deck I
Wood Screw Typical Opedn9
Assembly Side Section View
Deck
1513�' Nin.
[10
FL #: FL 13339.1 R6
Date: 1/4/18
Report No.: 18-101-SPAF-Dir-S4W-ER
Page 6 of 6
Speq=aftj Structural ErKWneaerino CBUCK, Inc. Certificate of Authorization &8064
Installation Method
Attic Breeze,, LLC.
Solar Attic Fan Attachment Assembly
...... ... . . .
Assembly Top Plan View