Loading...
HomeMy WebLinkAboutproduct approval (2)—.� - Regulation BCIS Home I Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications I FBC Staff BCIS Site Map { Links Search i Florida ON Product Approvalr USERPublic User Product Approval Menu > Application Detail •i FL # FL13339-R5 Application Type Revision Code Version 2014 Application Status Approved Comments Archived ❑ Product Manufacturer . Attic Breeze Address/Phone/Email 1370 FM 116 Gatesville, TX 76528 (254)865-9999 travis.hipp@atticbreeie.net Authorized Signature James Buckner jimmy@cbuckinc.net Technical Representative Travis Hipp Address/Phone/Email 1370 FM 116 Gatesville, TX 76528 (877) 288-4234 trav[s.hipp@atticbreeze.net Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Ci Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed James L. Buckner, P.E. @ CBUCK Engineering the Evaluation Report Florlda License PE-31242 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 12/01/2029 Validated By Michael John Werner, P.E. I] Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL13339 R5 COI FL13339 R5 COI CertOfIndeo.odf 1709.2 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Date Revised FL # Model, Number or Name A, 13339.1 01_Solar Attic Fan Method 2 Option B 06/14/2017 06/15/2017 06/21/2017 08/08/2017 01/05/2018 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +115/-115 other: Refer to evaluation report for limitations and conditions of use. Refer to manufacturer's installation instructions as a supplemental guide. 13339.2 1 02_Solar Attic Fan Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +115/-115 Other: Refer to evaluation report for limitations and conditions of use. Refer to manufacturer's installation instructions as a supplemental guide. 13339.3 1 03_Solar Attic Fan Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +115/-115 other: Refer to evaluation report for limitations and conditions of use. Refer to manufacturer's installation instructions as a supplemental guide. 13339.4 1 04_Solar Attic Fan Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +115/-115 other: Refer to evaluation report for limitations and conditions of use. Refer to manufacturer's installation instructions as a supplemental guide. Description Models AB-201A, AB-202A, AB-251A, AB-252A, AB-2022A, AB-3022A & AB-4022A. Self -flashing, solar powered fan units, with solar panel directly attached to fan unit shroud/dome installation Instructions FL13339 R5 II 1 Attic Breeze-SPAF Panel Direct to Flush Mount Unit EvalReport .odf Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL13339 R5 AE 1 Attic Breeze-SPAF Panel Direct to Flush Mount Unit EvalReport .Ddf Created by Independent Third Party: Yes Models AB-201D, AB-202D, AB-251D, AB-252D, AB-401, AB- 402, AB-2022D, AB-3022D & AB-4022D. Self -flashing, solar powered fan units, with solar panel(s) remotely attached from fan unit, using low profile mounting brackets Installation Instructions F: 13339 R5 II 2 Attic Breeze-SPAF Panel Remote to Low Profile EvalReport .odf Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL13339 R5 AE 2 Attic Breeze-SPAF Panel Remote to Low Profile EvalReport .odf Created by Independent Third Party: Yes Models AB-201D, AB-202D, AB-251D, AB-252D, AB-401, AB- 402, AB-2022D, AB-3022D & AB-4022D. Self -flashing, solar powered fan units, with solar panel(s) remotely attached from fan unit, using universal mounting bracket Installation Instructions FL13339 R5 II 3 Attic Breeze-SPAF Panel Remote Inclined EvalReport .odf Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports Fi 1 334g R5 AE 3 Attic Breeze-SPAF Panel Remote Inclined EyalRe op rt .odf Created by Independent Third Party: Yes Models AB-601, AB-602 & AB-6022D. Self -flashing, solar powered fan units, with solar panel remotely attached from fan unit, using low profile mounting brackets Installation Instructions FL13339 R5 II 4 Attic Breeze-SPAF Panel Remote to Low Profile EvalReport .odf Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL , 333o cc eF a Attic n ze-SPAF Panel Remote to Low Profile EvalReport .odf Created by Independent Third Party: Yes 13339.5 05_Solar Attic Fan Models AB-601, AB-602 & AB-6022D. Self -flashing, solar powered fan units, with solar panel remotely attached from fan unit, using universal mounting brackets Limits of Use Installation Instructions Approved for use in HVHZ: No FL13339 R5 Il 5 Attic Breeze-SPAF Panel Remote Approved for use outside HVHZ: Yes Inclined EvalReport odf Impact Resistant: No Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. Design Pressure: +115/-115 #31242 Other: Refer to evaluation report for limitations and Created by Independent Third Party: Yes conditions of use. Refer to manufacturer's installation Evaluation Reports instructions as a supplemental guide. FL13339 RS AE 5 Attic Breeze-SPAF Panel Remote Inclined EvalReport_pdf Created by Independent Third Party: Yes 13339.6 06_Cardinal Ventilation Models CV-2000 & CV-3000. Self -flashing, circular shaped solar powered fan units, with solar panel directly attached to fan unit hood/dome Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +115/-115 Other: Refer to evaluation report for limitations and Installation Instructions FL13339 R5 II 6 AB -Cardinal SPAF Panel Direct to Flush Mount Unit EvalReport Ddf Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242 Created by Independent Third Party: Yes conditions of use. Refer to manufacturer's Installation Evaluation Reports Instructions as a supplemental guide. FL13339 R5 AE 6 AS -Cardinal SPAF Panel Direct to Flush Mount Unit EvalReport .Ddf Created by Independent Third Party: Yes 13339.7 Curb Mount Series Curb Profile vent fan base for attachment to roof curbs Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +115/-115 Other: Refer to evaluation report for limitations and conditions of use. Installation Instructions FL13339 R5 II 17-144 2-7 ER Curb Base es.Ddf Verified By: James L Buckner, P.E. @CBUCK, Inc P.E. # 31242 Created by Independent Third Party: Yes Evaluation Reports FL13339 R5 AE 17-144 2-7 ER Curb Base es.Ddf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Cbovriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Aeeepte: MMM 99 Credit Card Safe _ SpPCldlft j r= Cucj'ural r=nC; Ir1L=E,rinQ CBUCK, Inc. Certificate of Authorization #8064 Evaluation Report "Solar Attic Fans" Self -Flashing Series with Shroud/Dome Mounted Solar Panel 20 Watts, 30 Watts & 40 Watts Solar Panels Manufacturer Attic Breeze, LLC. 1370 FM 116 Gatesville, Texas 76528 (877) 288-4234 for Florida Product Approval # FL 13339.1 R6 Florida Building Code 6th Edition (2017) Per Rule 61G20-3 Method: 2.- B Category: Roofing Sub - Category: Roofing Accessories that are an Integral Part of the Roofing System Product Name: Product Description: Prepared by: James L. Buckner, P.E., SECS Florida Professional Engineer # 31242 Florida Evaluation ANE ID: 1916 Report No. 18-101-SPAF-Dir-S4W-ER Date: 1/4/ 18 Contents: Evaluation Report Pages 1— 6 Solar Attic Fans Self -Flashing Series F csimil of digital copy signed by with Shroud/Dome Mounted Solar l�anPt es L. Buckner, P.E. Electronically signed and sealed documents comply with the provisions of FAC Rule 61G1! BuC * ; * ' No 31242 u 441 ��'•, STATE OF 2018.01.04 15:00:37-05'00' CBUCK, Inc. - Palm Beach County, Florida Phone: (561) 491-9927 • Email: cbuck@cbuckinc.net • Website: www.cbuckinc.net Spcecialrtj Structural IEngllnpprinq Manufacturer: Attic Breeze, LLC. Product Name: Solar Attic Fans Product Category: Roofing FL #: FL 13339.1 R6 Date: 1/4/18 Report No.: 18-.101-SPAF-Dir-S4W-ER Page 2 of 6 CBUCK, Inc. Certificate of Authorization #8064 Product Sub -Category Roofing Accessories that are an Integral part of the Roofing System Compliance Method: State Product Approval Rule 61G20-3.005 (2) (b) Product Description: The Solar Attic Fan is a roof mounted system powered by a solar panel. The unit consists of a 14 inch diameter fan, enclosed in a self -flashing fan house base vent, with corrosion resistant, zincalume alloy steel housing, including a thermal switch, and a rodent guard. The solar panel is attached directly to the fan house unit shroud/dome. Product Assembly as Self -flashing solar attic fan with shroud/dome mounted solar panel Evaluated: - Fan house base unit component mechanically attached to deck with wood screws. Model Numbers: No./Designation AB-201A AB-202A AB-251A AB-252A AB-2022A AB-3022A AB-4022A Fan Unit Base Support: Type: Wood Deck (Design of support system is outside the scope of this evaluation) Description: • 15/32" or greater Plywood, or • Wood plank deck (based on minimum density/specific gravity of 0.42) Roof Slope: Slope shall be in compliance with FBC, Chapter 15 based on the type of roof covering. Performance: Allowable Wind Resistance: * Positive Design Pressure: + 115 PSF * Negative Design Pressure: -115 PSF * Allowable design pressures for allowable stress design (ASD). Lim FL #: FL 13339.1 R6 Date: 1 / 4 / 18 Report No.: 18-101-SPAF-Dir-S4W-ER Page 3 of 6 Specialty Strucfi urat Engineering CBUCK, Inc. Certificate of Authorization #18064 Performance Standards: The following test protocol was performed to demonstrate compliance with the intent of the code as this product does not specifically addressed the performance standard in the code. • ASTM E330-02 —Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors and by Uniform Static Air Pressure Difference Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 6th Edition (2017), Section 1708.2. Evaluation Report Scope: This product evaluation demonstrates compliance of this product with the structural wind load requirements of the Florida Building Code, as related to Florida Product Approval Rule 61G20-3.001. Limits of Use: • The Solar Attic Fan including solar panel and electrical wiring shall be installed in compliance with Attic Breeze's installation instructions and in accordance with applicable Building Codes • Scope of "Limitations and Conditions of Use" for this evaluation: This evaluation report for "Optional Statewide Approval" contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under "Optional Statewide Approval". • Option for application outside "Limitations and Conditions of Use" Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific approvalby the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. • Refer to applicable building code section for ventilation requirements. • Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof vent products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certification, Inc. (FBC Organization #: QUA 1824) Specialty Structural Enc1neerinq Component(s) Solar Attic Fan Material Standards: - Nominal Dimensions Fan House Base: Fan House Shroud/ Dome: Solar Panel: Overall Height: FL #: FL 13339.1 R6 Date: 1 / 4 / 18 Report No.: 18-101-SPAF-Dir-S4W-ER Page 4 of 6 CBUCK, Inc. Certificate of Authorization #8064 28" x 28" 21-1/2" x 21-1/2" 19-1/4" x 16-1/4" 12" - Fan House Base & Shroud/Dome Material: Material: Steel Thickness: 22 ga. Yield Strength: 33 ksi Minimum Corrosion Resistance: Galvalume or Zincalume per ASTM A792 AZ 50 or in compliance with the FBC, Section 1507.4.3. Fastener Type: Size: Standard: Corrosion Resistance: Pancake Head Wood Screw #10 x 1 in. Minimum Per ANSI/ASME B18.6.1 Per FBC Section 1506.6 Installation: installation Method: (Refer to Pages 5 and 6 of this evaluation report.) "The Solar Attic fans" shall be installed in compliance with the installation method listed in this report. The installation method described herein is in accordance with the scope of this evaluation report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. Evaluated Referenced Data: 1. ASTM E330-02 Uniform Static Air Pressure Difference Test By Certified Testing Laboratories, Inc. (FBC Organization ID# TST 1577) Project #: CTLA 2002W, Dated: 11 / 20 / 09 2. Quality Assurance By Keystone Certification, Inc. (FBC Organization ID# QUA 1824) Attic Breeze, LLC. Licensee #740 3. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization # AN 1916) 4. Engineering Analysis By. CBUCK Engineering Report #C09-194, Dated: 12 / 1 / 09 Report #C16-164, Dated: 10 / 20 / 16 FL #: FL 13339.1 R6 Date: 1 / 4 / 18 CBVCK EngIneering Report No.: 18-101-SPAF-Dir-S4W-ER Page 5 of 6 .N SpPGatty Structural Encglnec=rinq LHULK InC. certIfICate Of Authorization #6U64 Installation Method Attic Breeze, LLC. Solar Attic Fan Attachment Assembly Fan House Shroud - Fan house #10 x V Pam Wood Screw Solar Panel 20" Diameter Plywood Deck Typical Opervng Assembly Front Section View Solar Panel 2114' Fan House Shroud Fan house Ir 2(Y' Diameter #10 x 1" Pancake -Head Plywood Deck I Wood Screw Typical Opedn9 Assembly Side Section View Deck 1513�' Nin. [10 FL #: FL 13339.1 R6 Date: 1/4/18 Report No.: 18-101-SPAF-Dir-S4W-ER Page 6 of 6 Speq=aftj Structural ErKWneaerino CBUCK, Inc. Certificate of Authorization &8064 Installation Method Attic Breeze,, LLC. Solar Attic Fan Attachment Assembly ...... ... . . . Assembly Top Plan View