Loading...
HomeMy WebLinkAboutproduct approval (3)7/29/2020 Florida Building Code Online BCIS Home Log In User Registration Hot Topics ; Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links xiµ• Search db d rL( ,...�-� Product Approval 1USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL17022-R7 Application Type Revision Code Version 2017 Application Status Approved Comments 08/18/2017v. date reapply 08/21/17 Archived Product Manufacturer Extreme Metal Fabricators, LLC Address/Phone/Email 2160 SW Poma Drive_ Palm City, FL 34990 (772)872-8034 flvalidation@yahoo.com Authorized Signature Richard McKuhen flvalidation@yahoo.com Technical Representative Richard McKuhen Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772)872-8034 rchard@emfab.net Quality Assurance Representative Address/Phone/Email Category Roofing , Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy. Received Florida Engineer or Architect Name who developed the LOCKE BOWDEN Evaluation Report Florida License - PE-49704 Quality Assurance Entity' Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/22/2024 . Validated By Zachary R. Priest, P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.pdf Referenced Standard and Year (of Standard) Standard Year TAS 125 2003 UL 1897 2012 UL•580 2006 Equivalence of Product Standards Certified By Sections from the Code 7/29/2020 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 08/18/2017 Date Validated 08/25/2017 Date Pending FBC Approval 08/28/2017 Date Approved 10/10/2017 Summary of Products FL # Model, Number or Name Description 17022.1 1 - "5V Crimp" (116) 26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel mechanically attached to 15/32" plywood or Wood Deck with fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.1 5 V CRIMP ssr.pdf Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ Table A . Evaluation Reports Other: Refer to evaluation report for conditions. Install the FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.pdf assembly in compliance with the installation method listed in Created by Independent Third Party: Yes this report and applicable code sections of FBC. Refer to manufacturer's installation. instructions. 17022.2 2 - "5V Crimp" (R6) 0.032" Aluminum, 3/8" Rib height, 21' wide lapped roof panel, mechanically attached to 15/32" plywood or Wood Deck with exposed fasteners Limits of Use Approved for use in HVHZ: No Installation Instructions FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr.pdf Verified By: Locke Bowden, P.E. 49704 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ Table A Other: Refer to evaluation report for conditions.Instali the Evaluation Reports FL17022 R7 AE FL 17022.2 '5 V CRIMP 0.032 ALUM ssr.pdf Created by Independent Third Party: Yes assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.3 3 - "1.5" Mechanical Seam" (115) 1.5" rib height, 16" wide, 24 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.3 1.5 MECHANICAL Approved for use outside HVHZ: Yes seam 24ga ssr.pdf Impact Resistant: No Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/ Table A Created by Independent Third Party: Yes Other. Refer to evaluation report for conditions and limitations Evaluation Reports of use. Install the asserbly in compliance with the installation FL17022 R7 AE FL 17022.3 1.5 MECHANICAL method listed in this report and applicable code sections of seam 24ga ssnpi f FBC. Refer to manufacturer's installation instructions. Created by Independent Third Party: Yes 17022.4 4 - "1.5" Mechanical Seam" (R5) 1.5" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to 15/32" plywood or Wood Deck with clips and fasteners. Limits of Use .Approved for use In HVHZ: No Installation Instructions FL17022 R7 II FL 17022.4 MECHANCIAL SEAM Approved for use outside HVHZ: Yes ALUMINUM ssr.pdf Impact Resistant: No Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/ Table A Created by Independent Third Party: Yes Other: Refer to evaluation report for conditions and limitations Evaluation Reports of use. Install the assembly in compliance with the installation FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM method listed in this report and applicable code sections of ALUMINUM ssr.pdf FBC. Refer to manufacturer's installation instructions. Created by Independent Third Party: Yes 17022.5 5 - "1 in. Nail Strip" (115) 1" rib height, 16" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Limits of Use Approved for use in HVHZ: No Installation Instructions FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ Table A Other: Refer to evaluation report for conditions and limitations Evaluation Reports FL17022 R7 AE FL 17022.5 i.0 NAILSTRIP ssr.pdf Created by Independent Third Party: Yes of use. Install the assembly in compliance with the installation 2160 SW Poma Drive Palm City, FL 34990 Compliant with Florida Building Code 2017 (61h ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Product: 1" Nailstrip 26GA Steel Roof Panel FBC Sec.1507.4.2 Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood Deck w/ 0.42 specific gravity with 16" Coverage (Max.) Rib Height I" Corrosion Resistant Compliant: FBC Sec.1507.4.3 Fastener 1: #10 x 1" (min.) Pancake Head Wood Screw to penetrate 3/16" (min.) thru bottom of support. Adhesive/Sealant : Bostik 9151 Chem -Chalk one component, polyurethane adhesive with 3/1V continuous bead application along base of male rib vertical flange at each panel seam. Underlayment: To be compliant with FBC Sec 1507.1.1 Slope: Shall be in compliance with FBC Sec.1507. Install Details: Table A Allowable Loads METHOD 1 METHOD 2 DESIGN PRESSURE* _ _- -86 PSF Main field -97.25 PSF Perimeter FASTENER SPACING 6" O.C. 6" O.C. SEAM ADHESIVE Not required 3/16" continuous bead I (see details) _ Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527 UL 580-0.6 & UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen #1 & #2 EQUIVALENCY: UL1897-04 is equivalent to Test Standard UL1897-12. *Design Pressure mar in of safe 2:1 Certificate of Independence: Locke Bowden, P.E. does not have, not will acquire a financial iip�St6nq9y05ompany manufacturing or distributing products under this evaluation. .�,�.� k ' Locke Bowden, P.E. is not owned, operated, or control)e `t�r�y� mR� , dian�i% tuner, or distributing products under this report. = // • =r, • '� ; ' seal s - h •• STATE OF i Q • . ate. •.c FLL�RIO�,•;� \y2. Limitations: 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 61h ed.. 2. Minimum slope to be compliant with Florida Building Code 2017 6"' ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities wrudsdicfion is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6"' ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. FL 17022.5 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details 16" Panel Profile 16" o.c. 3/4" —t— Deck: -15/32" or greater Plywood, or - Wood plank Integral Snap Lock .For METHOD 2: Apply 3/16" Bead Bostik 915Tm Sealant Continuous Along Male Rib Vertical Flange Fastener #10 X 1" Min. per Table "A" Pancake Head Wood Screw (Typical Fastening Pattern Across Width) 1° r FL 17022.5 1.0 Nail Strip (26GA Steel),16" Wide Roof Panel - Details MZ- or greater Plywood, or - Wood plank Faetcncr Isometric View Apply X16" Bead Bostik 91511 Sealant Continuous Along Male Rib Vertical Flange (Refer to Table 'IN')