HomeMy WebLinkAboutproduct approval (3)7/29/2020 Florida Building Code Online
BCIS Home Log In User Registration Hot Topics ; Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links xiµ• Search
db
d
rL( ,...�-� Product Approval
1USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL # FL17022-R7
Application Type Revision
Code Version 2017
Application Status Approved
Comments 08/18/2017v. date reapply 08/21/17
Archived
Product Manufacturer Extreme Metal Fabricators, LLC
Address/Phone/Email 2160 SW Poma Drive_
Palm City, FL 34990
(772)872-8034
flvalidation@yahoo.com
Authorized Signature Richard McKuhen
flvalidation@yahoo.com
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
rchard@emfab.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing ,
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy. Received
Florida Engineer or Architect Name who developed the LOCKE BOWDEN
Evaluation Report
Florida License - PE-49704
Quality Assurance Entity' Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024 .
Validated By Zachary R. Priest, P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.pdf
Referenced Standard and Year (of Standard) Standard Year
TAS 125 2003
UL 1897 2012
UL•580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
7/29/2020
Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted
08/18/2017
Date Validated
08/25/2017
Date Pending FBC Approval
08/28/2017
Date Approved
10/10/2017
Summary of Products
FL #
Model, Number or Name
Description
17022.1
1 - "5V Crimp" (116)
26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel
mechanically attached to 15/32" plywood or Wood Deck with
fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.1 5 V CRIMP ssr.pdf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ Table A .
Evaluation Reports
Other: Refer to evaluation report for conditions. Install the
FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.pdf
assembly in compliance with the installation method listed in
Created by Independent Third Party: Yes
this report and applicable code sections of FBC. Refer to
manufacturer's installation. instructions.
17022.2
2 - "5V Crimp" (R6)
0.032" Aluminum, 3/8" Rib height, 21' wide lapped roof panel,
mechanically attached to 15/32" plywood or Wood Deck with
exposed fasteners
Limits of Use
Approved for use in HVHZ: No
Installation Instructions
FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ Table A
Other: Refer to evaluation report for conditions.Instali the
Evaluation Reports
FL17022 R7 AE FL 17022.2 '5 V CRIMP 0.032 ALUM ssr.pdf
Created by Independent Third Party: Yes
assembly in compliance with the installation method listed in
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022.3
3 - "1.5" Mechanical Seam" (115)
1.5" rib height, 16" wide, 24 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with clips and fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.3 1.5 MECHANICAL
Approved for use outside HVHZ: Yes
seam 24ga ssr.pdf
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ Table A
Created by Independent Third Party: Yes
Other. Refer to evaluation report for conditions and limitations
Evaluation Reports
of use. Install the asserbly in compliance with the installation
FL17022 R7 AE FL 17022.3 1.5 MECHANICAL
method listed in this report and applicable code sections of
seam 24ga ssnpi f
FBC. Refer to manufacturer's installation instructions.
Created by Independent Third Party: Yes
17022.4
4 - "1.5" Mechanical Seam" (R5)
1.5" rib height, 16" wide, 0.032" aluminum, standing seam roof
panel mechanically attached to 15/32" plywood or Wood Deck
with clips and fasteners.
Limits of Use
.Approved for use In HVHZ: No
Installation Instructions
FL17022 R7 II FL 17022.4 MECHANCIAL SEAM
Approved for use outside HVHZ: Yes
ALUMINUM ssr.pdf
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and limitations
Evaluation Reports
of use. Install the assembly in compliance with the installation
FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM
method listed in this report and applicable code sections of
ALUMINUM ssr.pdf
FBC. Refer to manufacturer's installation instructions.
Created by Independent Third Party: Yes
17022.5
5 - "1 in. Nail Strip" (115)
1" rib height, 16" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with fasteners.
Limits of Use
Approved for use in HVHZ: No
Installation Instructions
FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ Table A
Other: Refer to evaluation report for conditions and limitations
Evaluation Reports
FL17022 R7 AE FL 17022.5 i.0 NAILSTRIP ssr.pdf
Created by Independent Third Party: Yes
of use. Install the assembly in compliance with the installation
2160 SW Poma Drive
Palm City, FL 34990
Compliant with Florida Building Code 2017 (61h ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Product: 1" Nailstrip 26GA Steel Roof Panel FBC Sec.1507.4.2
Yield strength: 50 ksi min.; Attached to min.15/32" plywood or
Wood Deck w/ 0.42 specific gravity with 16" Coverage (Max.)
Rib Height I"
Corrosion Resistant Compliant: FBC Sec.1507.4.3
Fastener 1: #10 x 1" (min.) Pancake Head Wood Screw to penetrate 3/16" (min.) thru
bottom of support.
Adhesive/Sealant : Bostik 9151 Chem -Chalk one component, polyurethane adhesive with
3/1V continuous bead application along base of male rib vertical flange at each panel
seam.
Underlayment: To be compliant with FBC Sec 1507.1.1
Slope: Shall be in compliance with FBC Sec.1507.
Install Details: Table A Allowable Loads
METHOD 1
METHOD 2
DESIGN PRESSURE* _ _-
-86 PSF Main field
-97.25 PSF Perimeter
FASTENER SPACING
6" O.C.
6" O.C.
SEAM ADHESIVE
Not required
3/16" continuous bead
I
(see details)
_
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527
UL 580-0.6 & UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen #1 & #2
EQUIVALENCY: UL1897-04 is equivalent to Test Standard UL1897-12. *Design Pressure mar in of safe 2:1
Certificate of Independence:
Locke Bowden, P.E. does not have, not will acquire a financial iip�St6nq9y05ompany manufacturing or distributing products
under this evaluation. .�,�.� k '
Locke Bowden, P.E. is not owned, operated, or control)e `t�r�y� mR� , dian�i% tuner, or distributing products under this
report. = // • =r,
• '� ; ' seal
s
- h •• STATE OF
i Q • . ate.
•.c FLL�RIO�,•;�
\y2.
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 61h ed..
2. Minimum slope to be compliant with Florida Building Code 2017 6"' ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities wrudsdicfion is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6"' ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural
Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
FL 17022.5 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details
16"
Panel Profile
16" o.c.
3/4"
—t—
Deck:
-15/32" or greater Plywood, or
- Wood plank
Integral Snap Lock
.For METHOD 2:
Apply 3/16" Bead Bostik 915Tm Sealant
Continuous Along Male Rib Vertical Flange
Fastener
#10 X 1" Min. per Table "A"
Pancake Head Wood Screw
(Typical Fastening Pattern Across Width)
1° r
FL 17022.5 1.0 Nail Strip (26GA Steel),16" Wide Roof Panel - Details
MZ- or greater Plywood, or
- Wood plank
Faetcncr
Isometric View
Apply X16" Bead Bostik 91511 Sealant
Continuous Along Male Rib Vertical Flange
(Refer to Table 'IN')