Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: ADAMS HOMES- 2508 MODEL Builder Name: ADAMS HOMES Street: 8113 AMALFI CIRCLE Permit Office: ST LUCIE COUNTY City, State, Zip: PORT ST LUCIE , FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2038.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1794.00 ft2 b. Frame - Wood, Adjacent R=11.0 244.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= fe 5. Is this a worst case? No 10. Ceiling Types (2508.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 2508.00 ft2 6. Conditioned floor area above grade (W) 2508 b. N/A R= ft2 Conditioned floor area below grade (W) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows (271.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: AHU CLST 6 200 a. U-Factor: Sgl, U=0.65 218.00 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.70 53.33 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 47.0 SEER:15.00 •" c. U-Factor: N/A ft2 ,,. SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.0 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.260 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2508.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2508.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.108 Total Proposed Modified Loads: 73.21 PASS Total Baseline Loads: 76.01 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. a !(ii�.»:"�s:��•���tiC) PREPARED BY: �SJ Before construction is completed DATE: 5-25-202U this building will be inspected for I . compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Eyre Co OWNER/AG BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. ® - Compliance requires an Air Barrier and Insulation Inspection Checklist infabs�c� r fFJ,0� 1 tind this project requires an envelope leakage test report with envelope leakage no greater thar� CIF 50 (134102.4.11.2). oy 0PAPLiANICE s.� UWY occ 5/22/2020 2:51 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: ADAMS HOMES- 2508 MODE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2508 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 8113 AMALFI CIRCLE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: PORT ST LUCIE, Family Type: Single-family FL, New/E)asting: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp I/ Design Location TMY Site 97.5 % 2.5 % Winter Summer, Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2508 22072 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 O WIC 1 44 352 No 0 1 Yes Yes Yes 2 O WIC 2 45 360 No 0 1 No Yes Yes 3 O BATH 119 952 No 0 1 Yes Yes Yes 4 LIVING ROOM 182 1456 No 0 1 Yes Yes Yes 5 FOYER 72 720 No 0 1 Yes Yes Yes 6 DINING ROOM 169 1690 No 0 1 Yes Yes Yes 7 FAMILY ROOM 542 5420 No 0 1 Yes Yes Yes 8 BREAKFAST 65 650 No 0 1 Yes Yes Yes 9 HALLWAY 85 680 No 0 1 No Yes Yes 10 KITCHEN 156 1560 Yes 0 1 No Yes Yes 11 HALL 2 52 416 No 0 1 No Yes Yes 12 LAUNDRY 73 584 No 0 1 No Yes Yes 13 AHU CLST 15 120 No 0 1 No Yes Yes 14 BATH 2 45 360 No 0 1 No Yes Yes 15 CLST 2 22 176 No 0 1 Yes Yes Yes 16 BEDROOM 2 143 1144 No 0 1 1 Yes Yes Yes 17 BEDROOM 3 132 1056 No 0 1 1 Yes Yes Yes 18 CLST 3 21 168 No 0 1 Yes Yes Yes 19 CLST 4 14 112 No 0 1 Yes Yes Yes 20 BEDROOM 4 143 1144 No 0 1 1 Yes Yes Yes 21 BATH 3 98 784 No 0 1 Yes Yes Yes 22 0 TOILET 24 192 No 0 1 No Yes Yes 5/22/2020 2:51 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 23 OWNERS BEDRO 247 1976 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation O W IC 1 9 ft 0 44 ft2 ---- 1 0 0 2 Slab -On -Grade Edge Insulation O W IC 2 1 ft 0 45 ft2 ---- 1 0 0 3 Slab -On -Grade Edge Insulation 0 BATH 11 ft 0 119 ft2 ---- 1 0 0 4 Slab -On -Grade Edge Insulation LIVING ROOM 32 ft 0 182 ft2 ---- 1 0 0 5 Slab -On -Grade Edge Insulation FOYER 8 ft 0 72 ft2 _--- 1 0 0 6 Slab -On -Grade Edge Insulation DINING ROOM 14 ft 0 169 ft2 ---- 1 0 0 7 Slab -On -Grade Edge Insulation FAMILY ROOM 18 ft 0 542 ft2 ---- 1 0 0 8 Slab -On -Grade Edge Insulation BREAKFAST 9 ft 0 65 ft2 ---- 1 0 0 9 Slab -On -Grade Edge Insulation HALLWAY 1 ft 0 85 ft2 ---- 1 0 0 10SIab-On-Grade Edge Insulation KITCHEN 1 ft 0 156 ft2 ---- 1 0 0 11SIab-On-Grade Edge Insulation HALL 2 1 ft 0 52 ft2 ---- 1 0 0 12SIab-On-Grade Edge Insulation LAUNDRY 1 ft 0 73 ft2 ---- 1 0 0 13SIab-On-Grade Edge Insulation AHU CLST 1 ft 0 15 ft2 ---- 1 0 0 14SIab-On-Grade Edge Insulation BATH 2 1 ft 0 45 ft2 ---- 1 0 0 15SIab-On-Grade Edge Insulation CLST 2 2ft 0 22 ft2 ---- 1 0 0 16SIab-On-Grade Edge Insulation BEDROOM 2 13 ft 0 143 ft2 ---- 1 0 0 17SIab-On-Grade Edge Insulation BEDROOM 3 12 ft 0 132 ft2 ---- 1 0 0 18SIab-On-Grade Edge Insulation CLST 3 3 ft 0 21 ft2 ---- 1 0 0 19SIab-On-Grade Edge Insulation CLST 4 2ft 0 14 ft2 ---- 1 0 0 20SIab-On-Grade Edge Insulation BEDROOM 4 24 ft 0 143 ft2 ---- 1 0 0 21SIab-On-Grade Edge Insulation BATH 3 14 ft 0 98 ft2 ---- 1 0 0 22SIab-On-Grade Edge Insulation 0 TOILET 1 ft 0 24 ft2 ---- 1 0 0 23SIab-On-Grade Edge Insulation OWNERS BEDR 41 ft 0 247 ft2 ---- 1 0 0 5/22/2020 2:51 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch I/ # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2805 ft2 0 ft2 Medium N 0.4 No 0.9 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2508 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) O WIC 1 30 Blown 44 ft2 0.1 Wood 2 Under Attic (Vented) O WIC 2 30 Blown 45ft2 0.1 Wood 3 Under Attic (Vented) 0 BATH 30 Blown 119 ft2 0.1 Wood 4 Under Attic (Vented) LIVING ROOM 30 Blown 182ft2 0.1 Wood 5 Under Attic (Vented) FOYER 30 Blown 72ft2 0.1 Wood 6 Under Attic (Vented) DINING ROOM 30 Blown 169 ft2 0.1 Wood 7 Under Attic (Vented) FAMILY ROOM 30 Blown 542 ft2 0.1 Wood 8 Under Attic (Vented) BREAKFAST 30 Blown 65 ft2 0.1 Wood 9 Under Attic (Vented) HALLWAY 30 Blown 85 ft2 0.1 Wood 10 Under Attic (Vented) KITCHEN 30 Blown 156 ft2 0.1 Wood 11 Under Attic (Vented) HALL 2 30 Blown 52 ft2 0.1 Wood 12 Under Attic (Vented) LAUNDRY 30 Blown 73 ft2 0.1 Wood 13 Under Attic (Vented) AHU CLST 30 Blown 15 ft2 0.1 Wood 14 Under Attic (Vented) BATH 2 30 Blown 45 ft2 0.1 Wood 15 Under Attic (Vented) CLST 2 30 Blown 22 ft2 0.1 Wood 16 Under Attic (Vented) BEDROOM 2 30 Blown 143 ft2 0.1 Wood 17 Under Attic (Vented) BEDROOM 3 30 Blown 132 ft2 0.1 Wood 18 Under Attic (Vented) CLST 3 30 Blown 21 ft2 0.1 Wood 19 Under Attic (Vented) CLST 4 30 Blown 14 ft2 0.1 Wood 20 Under Attic (Vented) BEDROOM 4 30 Blown 143 ft2 0.1 Wood 21 Under Attic (Vented) BATH 3 30 Blown 98 ft2 0.1 Wood 22 Under Attic (Vented) 0 TOILET 30 Blown 24 ft2 0.1 Wood 23 Under Attic (Vented) OWNERS BEDR 30 Blown 247ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space _ 1 SW Exterior Concrete Block - Int Insul 0 WIC 1 4.1 9 0 8 0 72.0 ft2 0 0 0.4 0 _ 2 SW Exterior Concrete Block - Int Insul 0 BATH 4.1 11 0 8 0 88.0 ft2 0 0 0.4 0 3 NE Exterior Concrete Block - Int InsuLIVING ROO 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 4 NW Exterior Concrete Block - Int InsuLIVING ROO 4.1 13 0 8 0 104.0 ft2 0 0 0.4 0 5 SW Exterior Concrete Block - Int InsuLIVING ROO 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 6 NW Exterior Concrete Block - Int Insul FOYER 4.1 8 0 10 0 80.0 ft2 0 0 0.4 0 5/22/2020 2:51 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space , Cavity WEt idth Height Aran Sheathing Framing Solar Below o 7 NW Exterior Concrete Block - Int InsuDINING ROO 4.1 13 0 10 0 130.0 ft2 0 0 0.4 0 8 S Exterior Concrete Block - Int InsuDINING ROO 4.1 1 0 10 0 10.0 ft2 0 0 0.4 0 9 NE Garage Frame- Wood DINING ROO 11 2 0 10 0 20.0 ft2 0 0.1 0.4 0 10 SE Exterior Concrete Block - Int InsuFAMILY ROO 4.1 18 0 10 0 180.0 ft2 0 0 0.4 0 11 S Exterior Concrete Block - Int InsuBREAKFAST 4.1 5 0 10 0 50.0 ft2 0 0 0.4 0 12 SE Exterior Concrete Block - Int InsuBREAKFAST 4.1 4 0 10 0 40.0 ft2 0 0 0.4 0 13 NW Garage Frame - Wood LAUNDRY 11 8 0 8 0 64.0 ft2 0 0.1 0.4 0 14 NE Garage Frame - Wood LAUNDRY 11 2 0 8 0 16.0 ft2 0 0.1 0.4 0 15 NW Garage Frame - Wood BATH 2 11 5 0 8 0 40.0 ft2 0 0.1 0.4 0 16 NE Exterior Concrete Block - Int Insul CLST 2 4.1 2 0 8 0 16.0 ft2 0 0 0.4 0 17 NW Garage Frame - Wood CLST 2 11 11 0 8 0 88.0 ft2 0 0.1 0.4 0 18 SW Garage Frame - Wood CLST 2 11 2 0 8 0 16.0 if 0 0.1 0.4 0 _ 19 NE Exterior Concrete Block - Int InsuBEDROOM 2 4.1 13 0 8 0 104.0 ft2 0 0 0.4 0 20 NE Exterior Concrete Block - Int InsuBEDROOM 3 4.1 12 0 8 0 96.0 ft2 0 0 0.4 0 _ 21 NE Exterior Concrete Block - Int Insul CLST 3 4.1 3 0 8 0 24.0 ft2 0 0 0.4 0 22 NE Exterior Concrete Block- Int Insul CLST 4 4.1 2 0 8 0 16.0 ft2 0 0 0.4 0 23 NE Exterior Concrete Block - Int InsuBEDROOM 4 4.1 13 0 8 0 104.0 ft2 0 0 0.4 0 24 SE Exterior Concrete Block - Int InsuBEDROOM 4 4.1 11 0 8 0 88.0 ft2 0 0 0.4 0 25 SW Exterior Concrete Block - Int Insul BATH 3 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 26 SE Exterior Concrete Block - Int Insul BATH 3 4.1 9 0 8 0 72.0 ft2 0 0 0.4 0 27 NE Exterior Concrete Block - Int InsuDWNERS BE 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 28 SW Exterior Concrete Block - Int Insu0W NERS BE 4.1 18 0 8 0 144.0 ft2 0 . 0 0.4 0 29 SE Exterior Concrete Block - Int InsuDW NERS BE 4.1 13 0 8 0 104.0 ft2 0 0 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated FOYER None .39 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 SW 2 Metal Low-E Single Yes 0.65 0.25 N 9.0 ft2 2 ft 0 in 1 ft 4 in None None 2 NW 4 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 2 ft 0 in 1 ft 4 in None None 3 SW 5 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 4 NW 7 Metal Low-E Single Yes 0.65 0.25 N 36.0 ft2 2 ft 0 in 1 ft 4 in None None 5 SE 10 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 2 ft 0 in 1 ft 4 in None None 6 SE 10 Metal Low-E Single Yes 0.7 0.3 N 17.8 ft2 2 ft 0 in 1 ft 4 in None None 7 S 11 Metal Low-E Single Yes 0.65 0.25 N 8.0 ft2 2 ft 0 in 1 ft 4 in None None 8 SE 12 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 9 NE 19 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 10 NE 20 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 2'ft 0 in 1 ft 4 in None None 11 SE 24 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 5/22/2020 2:51 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. V # Wall Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 12 13 14 SW 25 Metal Low-E Single NE 27 Metal Low-E Single SE 29 Metal Low-E Single Yes Yes Yes 0.7 0.3 N 17.8 ftz 2 ft 0 in 1 ft 4 in None 0.7 0.3 N 17.8 ft2 2 ft 0 in 1 ft 4 in None 0.65 0.25 N 30.0 ftz 2 ft 0 in 1 ft 4 in None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 528 ftz 528 ftz 30 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000391 2575.1 141.37 265.86 .1409 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Single HSPF:8.5 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 15 47 kBtu/hr 1410 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ftz DUCTS / # ---- Supply ---- Location R-Value Area ---- Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 200 ft' Attic 20 ftz Default Leakage AHU CLST (Default) c(Default) c 1 1 5/22/2020 2:51 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan HeatinJan Feb Feb Mar Mar Apr f Apr f May May Jun 4 Jun Jul 4 Jul Auge 4 Au4 Sep Oct f Oct f X� Nov Nov Dec f X} Dec VentingJan Feb X Mar [X] Apr [ May [ Jun [ Jul [ Aug [ Se [ Oct [Xj Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (W EH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 .78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 O W IC 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 O WIC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 O BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 O TOILET Default(8lbs/sq.ft. ft2 ft 0.3 O LINEN Default(8 Ibs/sq.ft. ft2 ft 0.3 LIVING ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 DINING ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 FAMILY ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 BREAKFAST Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 HALLWAY Default(8 Ibs/sq.ft. ft2 ft 0.3 AHU CLST Default(8 Ibs/sq.ft. ft2 ft 0.3 UTILITY Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 LINEN Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 4 Default(8 Ibs/s .ft. ft2 ft 0.3 OWNERS BEDRO 5/22/2020 2:51 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: ST LUCIE COUNTY Permit #: Job, Information . Builder: ADAMS HOMES Community: Lot: NA Address: 8113 AMALFI CIRCLE City: PORT ST LUCIE State: FL Zip: Al•r; Leakage Test Results Passing results, mast`meet,'"edher the Performance; .Prescriptive, or ER/ Mefhod PRESCRIPTIVE METHOD -The building -or dwelling, unit shall be tested°and-venfied,as having anair leakage rate of not exceeding 7 air . changes perzhour,at;a pressure bf 02 inch`w.g. (50"Pascals)in Climate -Zones` 1=and 2. • °, v O PERFORMANCE'or ERl'M ETHOD-The'building or dwelling,unit shall be tested and verified as hav'ng an air leakage rate of not exceeding the selected-ACH(50) value, as shown on Form R405-2017 (Performance) of R406-2017 (ERI), section labeled as -infiltration, sdb-section ACH50. ACH(50) specked on Form R405-2017-Energy Calc (Perforr mance,`) orR406-2017. (ERl): 7.000 x 60 _ 22072 = Method for calculating building volume: CFM(50) Building Volume ACH(50) O Retrieved from architectural plans F-1 PASS • Code software calculated When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Testing`Company Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 5/22/2020 2:52:10 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location AHU CLST 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 47.0 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2508 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.660 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.260 14. Heating system: Capacity 34.0 c) Area 7c. 271.3 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signatu Date: Address of New Home: 8113 AMALFI CIRCLE City/FL Zip: PORT ST LUCIE, FL 5/22/2020 2:51:32 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1