HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: ADAMS HOMES- 2508 MODEL
Builder Name: ADAMS HOMES
Street: 8113 AMALFI CIRCLE
Permit Office: ST LUCIE COUNTY
City, State, Zip: PORT ST LUCIE , FL,
Permit Number:
Owner:
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (2038.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1794.00 ft2
b. Frame - Wood, Adjacent
R=11.0 244.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= fe
5. Is this a worst case? No
10. Ceiling Types (2508.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2508.00 ft2
6. Conditioned floor area above grade (W) 2508
b. N/A
R= ft2
Conditioned floor area below grade (W) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows (271.3 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: AHU CLST
6 200
a. U-Factor: Sgl, U=0.65 218.00 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.70 53.33 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.30
a. Central Unit
47.0 SEER:15.00 •"
c. U-Factor: N/A ft2
,,.
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.0 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 2.000 ft.
Area Weighted Average SHGC: 0.260
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (2508.0 sqft.) Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 2508.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
None
Glass/Floor Area: 0.108 Total Proposed Modified Loads: 73.21
PASS
Total Baseline Loads: 76.01
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
a !(ii�.»:"�s:��•���tiC)
PREPARED BY: �SJ
Before construction is completed
DATE: 5-25-202U
this building will be inspected for
I .
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Eyre Co
OWNER/AG
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1. ®
- Compliance requires an Air Barrier and Insulation Inspection Checklist infabs�c� r fFJ,0� 1 tind this project requires
an envelope leakage test report with envelope leakage no greater thar� CIF 50 (134102.4.11.2).
oy 0PAPLiANICE
s.� UWY
occ
5/22/2020 2:51 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 7
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
ADAMS HOMES- 2508 MODE
Bedrooms: 4
Address Type:
Street Address
Building Type:
User
Conditioned Area: 2508
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle: 0
Street:
8113 AMALFI CIRCLE
Permit Office:
ST LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
PORT ST LUCIE,
Family Type:
Single-family
FL,
New/E)asting:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design
Daily Temp
I/ Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer,
Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2508
22072
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
O WIC 1
44
352 No
0
1
Yes
Yes
Yes
2
O WIC 2
45
360 No
0
1
No
Yes
Yes
3
O BATH
119
952 No
0
1
Yes
Yes
Yes
4
LIVING ROOM
182
1456 No
0
1
Yes
Yes
Yes
5
FOYER
72
720 No
0
1
Yes
Yes
Yes
6
DINING ROOM
169
1690 No
0
1
Yes
Yes
Yes
7
FAMILY ROOM
542
5420 No
0
1
Yes
Yes
Yes
8
BREAKFAST
65
650 No
0
1
Yes
Yes
Yes
9
HALLWAY
85
680 No
0
1
No
Yes
Yes
10
KITCHEN
156
1560 Yes
0
1
No
Yes
Yes
11
HALL 2
52
416 No
0
1
No
Yes
Yes
12
LAUNDRY
73
584 No
0
1
No
Yes
Yes
13
AHU CLST
15
120 No
0
1
No
Yes
Yes
14
BATH 2
45
360 No
0
1
No
Yes
Yes
15
CLST 2
22
176 No
0
1
Yes
Yes
Yes
16
BEDROOM 2
143
1144 No
0
1
1
Yes
Yes
Yes
17
BEDROOM 3
132
1056 No
0
1
1
Yes
Yes
Yes
18
CLST 3
21
168 No
0
1
Yes
Yes
Yes
19
CLST 4
14
112 No
0
1
Yes
Yes
Yes
20
BEDROOM 4
143
1144 No
0
1
1
Yes
Yes
Yes
21
BATH 3
98
784 No
0
1
Yes
Yes
Yes
22
0 TOILET
24
192 No
0
1
No
Yes
Yes
5/22/2020 2:51 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SPACES
Number Name
Area Volume
Kitchen Occupants
Bedrooms
InfilID Finished
Cooled
Heated
23 OWNERS BEDRO
247 1976
No 0
1
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulation
O W IC 1
9 ft
0
44 ft2
----
1
0
0
2 Slab -On -Grade Edge Insulation
O W IC 2
1 ft
0
45 ft2
----
1
0
0
3 Slab -On -Grade Edge Insulation
0 BATH
11 ft
0
119 ft2
----
1
0
0
4 Slab -On -Grade Edge Insulation
LIVING ROOM
32 ft
0
182 ft2
----
1
0
0
5 Slab -On -Grade Edge Insulation
FOYER
8 ft
0
72 ft2
_---
1
0
0
6 Slab -On -Grade Edge Insulation
DINING ROOM
14 ft
0
169 ft2
----
1
0
0
7 Slab -On -Grade Edge Insulation
FAMILY ROOM
18 ft
0
542 ft2
----
1
0
0
8 Slab -On -Grade Edge Insulation
BREAKFAST
9 ft
0
65 ft2
----
1
0
0
9 Slab -On -Grade Edge Insulation
HALLWAY
1 ft
0
85 ft2
----
1
0
0
10SIab-On-Grade Edge Insulation
KITCHEN
1 ft
0
156 ft2
----
1
0
0
11SIab-On-Grade Edge Insulation
HALL 2
1 ft
0
52 ft2
----
1
0
0
12SIab-On-Grade Edge Insulation
LAUNDRY
1 ft
0
73 ft2
----
1
0
0
13SIab-On-Grade Edge Insulation
AHU CLST
1 ft
0
15 ft2
----
1
0
0
14SIab-On-Grade Edge Insulation
BATH 2
1 ft
0
45 ft2
----
1
0
0
15SIab-On-Grade Edge Insulation
CLST 2
2ft
0
22 ft2
----
1
0
0
16SIab-On-Grade Edge Insulation
BEDROOM 2
13 ft
0
143 ft2
----
1
0
0
17SIab-On-Grade Edge Insulation
BEDROOM 3
12 ft
0
132 ft2
----
1
0
0
18SIab-On-Grade Edge Insulation
CLST 3
3 ft
0
21 ft2
----
1
0
0
19SIab-On-Grade Edge Insulation
CLST 4
2ft
0
14 ft2
----
1
0
0
20SIab-On-Grade Edge Insulation
BEDROOM 4
24 ft
0
143 ft2
----
1
0
0
21SIab-On-Grade Edge Insulation
BATH 3
14 ft
0
98 ft2
----
1
0
0
22SIab-On-Grade Edge Insulation
0 TOILET
1 ft
0
24 ft2
----
1
0
0
23SIab-On-Grade Edge Insulation
OWNERS BEDR
41 ft
0
247 ft2
----
1
0
0
5/22/2020 2:51 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
ROOF
/
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
I/
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Composition shingles 2805 ft2
0 ft2 Medium
N
0.4
No 0.9
No 0
26.6
ATTIC
/
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
300
2508 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) O WIC 1
30
Blown
44 ft2
0.1
Wood
2
Under Attic (Vented) O WIC 2
30
Blown
45ft2
0.1
Wood
3
Under Attic (Vented) 0 BATH
30
Blown
119 ft2
0.1
Wood
4
Under Attic (Vented) LIVING ROOM
30
Blown
182ft2
0.1
Wood
5
Under Attic (Vented) FOYER
30
Blown
72ft2
0.1
Wood
6
Under Attic (Vented) DINING ROOM
30
Blown
169 ft2
0.1
Wood
7
Under Attic (Vented) FAMILY ROOM
30
Blown
542 ft2
0.1
Wood
8
Under Attic (Vented) BREAKFAST
30
Blown
65 ft2
0.1
Wood
9
Under Attic (Vented) HALLWAY
30
Blown
85 ft2
0.1
Wood
10
Under Attic (Vented) KITCHEN
30
Blown
156 ft2
0.1
Wood
11
Under Attic (Vented) HALL 2
30
Blown
52 ft2
0.1
Wood
12
Under Attic (Vented) LAUNDRY
30
Blown
73 ft2
0.1
Wood
13
Under Attic (Vented) AHU CLST
30
Blown
15 ft2
0.1
Wood
14
Under Attic (Vented) BATH 2
30
Blown
45 ft2
0.1
Wood
15
Under Attic (Vented) CLST 2
30
Blown
22 ft2
0.1
Wood
16
Under Attic (Vented) BEDROOM 2
30
Blown
143 ft2
0.1
Wood
17
Under Attic (Vented) BEDROOM 3
30
Blown
132 ft2
0.1
Wood
18
Under Attic (Vented) CLST 3
30
Blown
21 ft2
0.1
Wood
19
Under Attic (Vented) CLST 4
30
Blown
14 ft2
0.1
Wood
20
Under Attic (Vented) BEDROOM 4
30
Blown
143 ft2
0.1
Wood
21
Under Attic (Vented) BATH 3
30
Blown
98 ft2
0.1
Wood
22
Under Attic (Vented) 0 TOILET
30
Blown
24 ft2
0.1
Wood
23
Under Attic (Vented) OWNERS BEDR
30
Blown
247ft2
0.1
Wood
WALLS
Adjacent Cavity Width
Height
Sheathing Framing Solar
Below
Space
_ 1
SW
Exterior Concrete Block - Int Insul 0 WIC 1
4.1 9
0 8
0
72.0 ft2
0 0
0.4
0
_ 2
SW
Exterior Concrete Block - Int Insul 0 BATH
4.1 11
0 8
0
88.0 ft2
0 0
0.4
0
3
NE
Exterior Concrete Block - Int InsuLIVING ROO
4.1 5
0 8
0
40.0 ft2
0 0
0.4
0
4
NW
Exterior Concrete Block - Int InsuLIVING ROO
4.1 13
0 8
0
104.0 ft2
0 0
0.4
0
5
SW
Exterior Concrete Block - Int InsuLIVING ROO
4.1 14
0 8
0
112.0 ft2
0 0
0.4
0
6
NW
Exterior Concrete Block - Int Insul FOYER
4.1 8
0 10
0
80.0 ft2
0 0
0.4
0
5/22/2020 2:51 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space ,
Cavity
WEt idth
Height
Aran
Sheathing Framing
Solar Below
o
7
NW
Exterior
Concrete Block - Int InsuDINING ROO
4.1
13
0
10 0
130.0 ft2
0
0
0.4
0
8
S
Exterior
Concrete Block - Int InsuDINING ROO
4.1
1
0
10 0
10.0 ft2
0
0
0.4
0
9
NE
Garage
Frame- Wood DINING ROO
11
2
0
10 0
20.0 ft2
0
0.1
0.4
0
10
SE
Exterior
Concrete Block - Int InsuFAMILY ROO
4.1
18
0
10 0
180.0 ft2
0
0
0.4
0
11
S
Exterior
Concrete Block - Int InsuBREAKFAST
4.1
5
0
10 0
50.0 ft2
0
0
0.4
0
12
SE
Exterior
Concrete Block - Int InsuBREAKFAST
4.1
4
0
10 0
40.0 ft2
0
0
0.4
0
13
NW
Garage
Frame - Wood LAUNDRY
11
8
0
8 0
64.0 ft2
0
0.1
0.4
0
14
NE
Garage
Frame - Wood LAUNDRY
11
2
0
8 0
16.0 ft2
0
0.1
0.4
0
15
NW
Garage
Frame - Wood BATH 2
11
5
0
8 0
40.0 ft2
0
0.1
0.4
0
16
NE
Exterior
Concrete Block - Int Insul CLST 2
4.1
2
0
8 0
16.0 ft2
0
0
0.4
0
17
NW
Garage
Frame - Wood CLST 2
11
11
0
8 0
88.0 ft2
0
0.1
0.4
0
18
SW
Garage
Frame - Wood CLST 2
11
2
0
8 0
16.0 if
0
0.1
0.4
0
_ 19
NE
Exterior
Concrete Block - Int InsuBEDROOM 2
4.1
13
0
8 0
104.0 ft2
0
0
0.4
0
20
NE
Exterior
Concrete Block - Int InsuBEDROOM 3
4.1
12
0
8 0
96.0 ft2
0
0
0.4
0
_ 21
NE
Exterior
Concrete Block - Int Insul CLST 3
4.1
3
0
8 0
24.0 ft2
0
0
0.4
0
22
NE
Exterior
Concrete Block- Int Insul CLST 4
4.1
2
0
8 0
16.0 ft2
0
0
0.4
0
23
NE
Exterior
Concrete Block - Int InsuBEDROOM 4
4.1
13
0
8 0
104.0 ft2
0
0
0.4
0
24
SE
Exterior
Concrete Block - Int InsuBEDROOM 4
4.1
11
0
8 0
88.0 ft2
0
0
0.4
0
25
SW
Exterior
Concrete Block - Int Insul BATH 3
4.1
5
0
8 0
40.0 ft2
0
0
0.4
0
26
SE
Exterior
Concrete Block - Int Insul BATH 3
4.1
9
0
8 0
72.0 ft2
0
0
0.4
0
27
NE
Exterior
Concrete Block - Int InsuDWNERS BE
4.1
10
0
8 0
80.0 ft2
0
0
0.4
0
28
SW
Exterior
Concrete Block - Int Insu0W NERS BE
4.1
18
0
8 0
144.0 ft2
0 .
0
0.4
0
29
SE
Exterior
Concrete Block - Int InsuDW NERS BE
4.1
13
0
8 0
104.0 ft2
0
0
0.4
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
E
Insulated FOYER
None
.39
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
SW 2
Metal Low-E Single Yes
0.65
0.25
N
9.0 ft2
2 ft 0 in
1 ft 4 in
None
None
2
NW 4
Metal Low-E Single Yes
0.65
0.25
N
30.0 ft2
2 ft 0 in
1 ft 4 in
None
None
3
SW 5
Metal Low-E Single Yes
0.65
0.25
N
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
4
NW 7
Metal Low-E Single Yes
0.65
0.25
N
36.0 ft2
2 ft 0 in
1 ft 4 in
None
None
5
SE 10
Metal Low-E Single Yes
0.65
0.25
N
30.0 ft2
2 ft 0 in
1 ft 4 in
None
None
6
SE 10
Metal Low-E Single Yes
0.7
0.3
N
17.8 ft2
2 ft 0 in
1 ft 4 in
None
None
7
S 11
Metal Low-E Single Yes
0.65
0.25
N
8.0 ft2
2 ft 0 in
1 ft 4 in
None
None
8
SE 12
Metal Low-E Single Yes
0.65
0.25
N
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
9
NE 19
Metal Low-E Single Yes
0.65
0.25
N
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
10
NE 20
Metal Low-E Single Yes
0.65
0.25
N
15.0 ft2
2'ft 0 in
1 ft 4 in
None
None
11
SE 24
Metal Low-E Single Yes
0.65
0.25
N
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
5/22/2020 2:51 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
V #
Wall
Ornt ID Frame Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
12
13
14
SW 25 Metal Low-E Single
NE 27 Metal Low-E Single
SE 29 Metal Low-E Single
Yes
Yes
Yes
0.7 0.3 N 17.8 ftz 2 ft 0 in 1 ft 4 in None
0.7 0.3 N 17.8 ft2 2 ft 0 in 1 ft 4 in None
0.65 0.25 N 30.0 ftz 2 ft 0 in 1 ft 4 in None
None
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
528 ftz 528 ftz
30 ft 8 ft 11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000391
2575.1 141.37 265.86 .1409 7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity Block
Ducts
1
Electric Heat Pump/
Split
Single HSPF:8.5 34 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split
Single SEER: 15 47 kBtu/hr 1410 cfm 0.8 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.98 50 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ftz
DUCTS
/
#
---- Supply ----
Location R-Value Area
---- Return ---- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1
Attic 6 200 ft'
Attic
20 ftz Default Leakage AHU CLST (Default) c(Default) c
1 1
5/22/2020 2:51 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat:
N
Ceiling Fans:
CoolingJan
HeatinJan
Feb
Feb
Mar
Mar
Apr
f Apr
f
May
May
Jun
4 Jun
Jul
4 Jul
Auge
4 Au4
Sep
Oct
f Oct f X�
Nov
Nov
Dec
f X} Dec
VentingJan
Feb
X Mar
[X] Apr
[
May
[ Jun
[ Jul
[ Aug
[
Se
[ Oct [Xj
Nov
[ ]Dec
Thermostat Schedule: HERS
2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Cooling (W EH)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
.78
78
78
78
Heating (WD)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
O W IC 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
O WIC 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
O BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
O TOILET
Default(8lbs/sq.ft.
ft2
ft
0.3
O LINEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LIVING ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FOYER
Default(8 Ibs/sq.ft.
ft2
ft
0.3
DINING ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FAMILY ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BREAKFAST
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALLWAY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
AHU CLST
Default(8 Ibs/sq.ft.
ft2
ft
0.3
UTILITY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LINEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 4
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALL
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 4
Default(8 Ibs/s .ft.
ft2
ft
0.3
OWNERS BEDRO
5/22/2020 2:51 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction: ST LUCIE COUNTY
Permit #:
Job, Information .
Builder: ADAMS HOMES Community: Lot: NA
Address: 8113 AMALFI CIRCLE
City: PORT ST LUCIE State: FL Zip:
Al•r; Leakage Test Results Passing results, mast`meet,'"edher the Performance; .Prescriptive, or ER/ Mefhod
PRESCRIPTIVE METHOD -The building -or dwelling, unit shall be tested°and-venfied,as having anair leakage rate of not exceeding 7 air .
changes perzhour,at;a pressure bf 02 inch`w.g. (50"Pascals)in Climate -Zones` 1=and 2. • °,
v
O PERFORMANCE'or ERl'M ETHOD-The'building or dwelling,unit shall be tested and verified as hav'ng an air leakage rate of not exceeding
the selected-ACH(50) value, as shown on Form R405-2017 (Performance) of R406-2017 (ERI), section labeled as -infiltration, sdb-section ACH50.
ACH(50) specked on Form R405-2017-Energy Calc (Perforr mance,`) orR406-2017. (ERl): 7.000
x 60 _ 22072 = Method for calculating building volume:
CFM(50) Building Volume ACH(50) O Retrieved from architectural plans
F-1 PASS • Code software calculated
When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated
must be verified by building department.
R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals).
Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section
489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration
control measures.
2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control
measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
Testing`Company
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification #: Issuing Authority:
5/22/2020 2:52:10 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location AHU
CLST
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
4
13. Cooling system: Capacity
47.0
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
2508
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.660
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.260
14. Heating system: Capacity
34.0
c) Area
7c.
271.3
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.98
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
No
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signatu Date:
Address of New Home: 8113 AMALFI CIRCLE City/FL Zip: PORT ST LUCIE, FL
5/22/2020 2:51:32 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1