HomeMy WebLinkAboutDesign Certification for Wind Load ComplianceSt. Lucie County
Building and Zoning Department
2300 Virginia Avenue
Fort Pierce, FL 34982
772-462-1553
Design Certification for Wind Load Compliance
This'Certification is to be completed by the project design architect or engineer. This Certification must be submitted with all
applications for building permits involving the construction of new residence (single or multi- family), residential addition, any
accessory structure requiring a building permit, and any nonresidential structure. This Certification shall not apply to interior
renovations (provided that no structural walls, columns or other similar component is being effected) and certain other minor building
permits. For further assistance, please contact the Building Inspection Office at 462-1553 or 462-2172.
Project Name
►.t-en e? V1
Street Address
'KIN Gv v off
Permit Number
e1g�2-- Oil
Occupancy Type
Construction Type
Certification Statement:
I certify that, to the best of my knowledge and belief, these plans is s h n „ to
comply with the applicable structural portion of the Building CodFdo to , d e rce e
County. I also certify that structural elements depicted on these plans provide a equat "st e
loads and forces specified by current code provisions.
Desicn Parameters and Assumptions Used- XPlease check or complete the appropriate box.)
1. Florida Building, Code 2004 Edition V ASCE 7-
Inclusive of 2006 and 2007 revisions.
2. Building Design is (check one) Enclosed Partially Enclosed Open Building
3. Building Height: y% p )"'`I 4. Wind Speed Used in Building Design: 1410 3 second gust
S. Wind Exposure Classification (refer to exposure tables in Building Code identified in Line #1): a
6. Average Wind Velocity Pressure on Exterior Faces of Structure 4.5 PSF
}y 7. Peak Wind Velocity Pressure on Exterior Faces of Structure 71 PSF
S. Importance/Use Factor (obtain from Building Code): A 6
• 9. Loads: Floor 6 Jr' PSF Roof/dead 2 S PSF Roof/live 10 PSF
10. Were Shear Walls Considered for Structure (check one): Yes �% No (if No, attach explanation)
11. Is a Continuous Load Path Provided (check one): Yes ✓ No (if No, attach explanation)
12. Are Component and Cladding Detail Provided (check one): Yes ✓ No (if No, attach explanation)
13. Minimum Soil Beari.ng•Pressure: _; Rl PSF
As witnessed b y s al. "re eer :. t information included with this certification is true and
correct, to th es my- d a ! .
y
Name: _ i. ; Certification #: 6601110 5� [Seal Here]
Design Firm: Date: / 0 O SLCCDV Form # 020-00