Loading...
HomeMy WebLinkAboutConstruction PlansDESIGN CRITERIA: APPLICABLE CODES, REGULATIONS & STANDARDS 1. THE 2017 FLORIDA BUILDING CODE, SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CH. 23 WOOD. 2. AA ASM 35 & SPECIFICATIONS FOR ALUMINUM STRUCTURES, PART 1-A OF THE ALUMINUM DESIGN MANUEL PREPARED BY THE ALUMINUM ASSOCIATION, INC. WASHINGTON D.C. 2005 ED. 3. ASCE 7-10 & SE17 4. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 5. ACI318 CONCRETE REFRENCE MANUAL. WIND LOADS 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY 1. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH 1609.3.1 & TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEED: 150 MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: B 3. WIND LOADS PER FBC TABLE 2002.4 (MWFRS) VULT = 150 MPH & EXPOSURE = B FOR 20 X 20 X 0.013" MESH SCREEN HORIZONTAL PRESSURES ON WINDWARD SURFACES = 31 PSF HORIZONTAL PRESSURES ON LEEWARD SURFACES = 32 PSF VERTICAL. PRESSURES ON SCREEN SURFACES = 9 PSF VERTICAL PRESSURES ON SOLID SURFACES = 25 PSF FOR 18 X 14 X 0.013" MESH SCREEN, APPLIED FACTOR = •88 FOR ALLOWABLE STRESS DESIGN, APPLIED FACTOR = •6 FOUNDATION DESIGN FOOTING SIZE EXISTING CONCRETE SLAB. NO ADDITIONAL FOOTING OR FOUNDATION SYSTEM IS REQUIRED BY THE PROPOSED CONSTRUCTION IF A MINIMUM 4" CONCRETE SLAB IS PROVIDED IN SOUND CONDITION, FREE FROM STRUCTURAL CRACKING, SPALLING & OTHER DETERIORATION. EXISTING FOUNDATION/FOOTING UNDER CONCRETE SLAB MINIMUM 8"x8" W/ (1) #5 BAR TO BE VERIFIED BY CONTRACTOR. SEE TYPICAL FOOTING DETAILS FOR NEW FOOTING DESIGN MINIMUM REQUIREMENTS. SPECIFICATIONS THE FOLLOWING SPECIFICATIONS ARE APPLICABLE TO THIS PROJECT: 1. WHERE CONCRETE SPECIFICATIONS ARE REQUIRED, WHETHER IN THE SCREEN ENCLOSURE SCOPE OF NOT, BY ONE OR MORE REGULATORY AGENCY, THE FOLLOWING SPECIFICATIONS ARE APPLICABLE: a. CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING COMPONENTS: i. PORTLAND CEMENT TYPE I - ASTM C 150 ii AGGREGATES - LARGE AGGREGATE 3/4 MAX. - ASTM C 33 iii. AIR ENTRAINING +/- 1 %- ASTM C 260 iv. WATER REDUCING AGENT - ASTM C 494 v. CLEAN PORTABLE WATER vi. OTHER ADMIXTURES NOT PERMITTED b. METAL ACCESSORIES SHALL CONFORM TO: i. REINFORCING BARS - ASTM A615, GRADE 60 ii. WELDED WIRE FABRIC - ASTM Al85 c. CONCRETE SLUMP AT DISCHARGE CHUTE NOT LESS THAN 3" OR MORE THAN 5". WATER ADDED AFTER BATCHING IS NOT PERMITTED. d. PREPARE & PLACE CONCRETE PER AMERICAN CONCRETE INSTITUTE MANUAL OF STANDARD PRACTICE, PART 1, 2, & 3 INCLUDING HOT WHEATHER RECOMMENDATIONS. e. MOIST CURE OR POLYETHYLENE CURING PERMITTED. f. PRIOR TO PLACING CONCRETE, TREAT THE ENTIRE SUBSURFACE ARE FOR TERMITES IN COMPLIANCE WITH THE FBC. g. CONCRETE SHALL BE PLACED OVER A POLYETHYLENE VAPOR BARRIER. 2. WHEN PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT 3. WHEN APPLICABLE FOR NEW SLAB ADDITION TO ADJACENT DRILL & EPDXY #5 X 8" REBAR INTO EX. FOUNDATION WITH 1" MIN. HOLE, EMBED 4" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) 4$" O.C. TYP. ALL LOCATIONS 4. WHEN APPLICABLE FOR NEW FOOTER TO EXISTING, DRILL & EPDXY NEW STEEL INTO EX. FOUNDATION WITH I" MIN. HOLE, EMBED 6" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) TYP. ALL LOCATIONS 5. MINIMUM CONCRETE STRENGTH 3000 PSI UNLESS OTHERWISE NOTED. ALUMINUM SPECIFICATIONS 1. ALUMINUM EXTRUSIONS SHALL BE 6005 T5 ALLOY UNLESS OTHERWISE NOTED. 2. ALL SELF MATING BEAM SECTIONS ARE TO BE STITCHED WITH # 12 SCREWS 6" FROM ENDS & 24" CENTER TO CENTER. 3. ROOF BRACING SHALL BE A MINIMUM 2"X2"X.050". 4. THE MINIMUM NORMAL THICKNESS OF PROTECTOR PANELS (KICKPLATES) SHALL BE AN INDUSTRY STANDARD OF 0.024 INCHES. 5. VINYL AND ACRYLIC PANELS SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH PER FBC. 6. SCREEN MATERIAL SHALL BE 18/14 SCREEN UNLESS APPROVED BY FLORIDA ENGINEERING LLC. 5. 1 "X2" & 1 "X3" NON STRUCTURAL MEMBERS MAY BE USED INTERCHANGEABLY. FASTENER SPECIFICATIONS 1. FASTENERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. (CONCRETE ANCHORS ARE TO BE TAPCONS OR BETTER, INSTALLED TO MFG. SPECIFICATIONS) 2. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, FASTENERS AND SCREENS TO MANUFACTURING SPECIFICATIONS. 3. WHERE WOOD DECK IS PRESENT USE 1 /4" X 3-1/2" GALV. LAG SCREWS IN LIEU OF MASONRY ANCHORS. UNLESS OTHERWISE SPECIFIED. 4. 1 "X2" NON STRUCTURAL MEMBERS ATTACHED TO HOST A. FOR MASONRY/CONCRETE APPLICATION USE GALVANIZED 1 /4" X 2-3/4" TAPCONS OR EQUAL AT 24" O.C. AND 6" FROM ENDS B. FOR WOOD APPLICATION USE # 14 X 2-3/4" WOOD SCREW AT 24" O.C. AND 6" FROM ENDS. C. FOR ALUMINUM APPLICATION USE # 10 X 1-1 /2" SMS OR TEK SCREW AT 24" O.C. AND 6" FROM ENDS D. WHERE 1 "X2" INSTALLED THROUGHOUT AN "OPEN VIEW' SPACING SHALL BE REDUCED TO 18" O.C. AND 6" FROM ENDS MASONRY SPECIFICATIONS 1. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2. ALL MORTAR SHALL BE TYPE M OR S. 3. ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4. PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5'-0" IN HEIGHT. MISCELLANEOUS 1. SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC R4501.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. 2. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPERATE 4TH WALL SUPPORT SYSTEM IS SO TO BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 3. DOOR LOCATION MAY BE RELOCATED BY CONTRACTOR IN THE FIELD. 4. WHERE PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT. 5. INTEGRITY OF EXISTING/ HOST STRUCTURE SHALL NOT BE COMPROMISED WITH THE ATTACHMENT OF THE PROPOSED STRUCTURE. 6. ALL 2X4 & GREATER ARE TO BE 2 x 4 SMB: 2"x4"x0.044"x0.100" UNLESS OTHERWISE INDICATED. RESPONSIBILITIES 1. ALL SITE WORK SHALL BE PERFORMED BY A LISCENED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDANANCES, AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. 2. FOR FASTENERS WHICH ARE NOT VISIBLE AFTER INSTALLATION, THE CONTRACTOR SHALL VERIFY AND ENSURE INSTALLATION HAS BEEN ACCOMPLISHED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH THE ATTACHED DETAILS. 3. FOR "PICTURE WINDOW" MODIFICATION TO EXISTING SCREEN ENCLOSURES, ALL OTHER "EXISTING SCREEN ENCLOSURE" FEATURES ARE TO MEET THE TYPICAL DETAILS AS PROVIDED IN THESE DETAILS. CONTRACTOR IS TO VERIFY & ASSURE EXISTING SCREEN ENCLOSURE IS STRUCTUALLY SOUND. ALUMINUM MEMBERS DIMENSIONS HOLLOW SECTIONS 2 x 2: 2" x 2" x 0.050" 2 x 3: 2" x 3" x 0.050" 2 x 4: 2" x 4" x 0.050" 2 x 5: 2" x 5" x 0.050" OPEN BACK SECTIONS 1 x2: 1"x2"x0.044" 1 x3: 1"x3"x0.045" SNAP SECTIONS 2 x 2 SNAP: 2" x 2" x 0.045' 2 x 3 SNAP: 2" x 3" x 0.050' 2 x 4 SNAP: 2" x 4" x 0.045" SELF MATING (SMB) 2 x 4 SM B: 2" x 4" x 0.046" x 0. 100" 2 x 5 SMB: 2" x 5" x 0.050" x 0. 116" 2 x 6 SMB: 2" x 6" x 0.050" x 0. 120" 2 x 7 S MB: 2" x 7" x 0.055" x 0. 120" 2 x 8 SMB: 2" x 8" x 0.072" x 0.224" 2 x 9 SMB: 2" x 9" x 0.072" x 0.224' 2 x 9(H) SMB: 2" x 9" x 0.082" x 0.306" 2 x 10 SMB: 2" x 10" x 0.092" x 0.374" DETAIL A L 9 ::020 nty, Permitting LL _�O:z C:)O o J LLI c N W elf: -� :U (o Q O: Z- o N CUD O OLij IIIIIII ti THESE PLANS WERE PREPARED BASED ON THE PREMISE THAT THE EXISTING STRUCTURE WAS DESIGNED BY A PROPERLY LICENSED PROFESSIONAL ENGINEER OF THE STATE OF FLORIDA, WAS PERMITTED BY THE APPROPRIATE PERMITTING AGENCY, WAS CONSTRUCTED BY A FLORIDA LICENSED CONTRACTOR AT THE TIME OF CONSTRUCTION, HAS NOT BEEN SUBJECT TO DAMAGE BY A MAJOR EVENT, AND HAS BEEN CERTIFIED BY THE CONTRACTOR THAT THE EXISTING STRUCTURE CURRENTLY SHOWS NO DEVIATIONS OR DEFECTS FROM THE STATE OF THE STRUCTURE AS PERMITTED BY THE FINAL INSPECTION OF THE PERMITTING AGENCY. ALSO, THE OWNER AND ALL PARTIES CONCERNED WILL INDEMNIFY FLORIDA ENGINEERING LLC FROM ANY DAMAGES OR CHANGES TO THE EXISTING STRUCTURE AS A RESULT OF ANY MODIFICATION OR FOR ANY OTHER REASON. HOST 12" O/H (FASCIA MOUNT) 1X2-;---------------II---------------,- I II I I �D ~ X I 2X3 Qi 3" X .024" X 11-13 COMPOSITE PANELSii m m ' HATCH DENOTES 2X2 DJ o -1 7-1 3105-H154 ii Ln Ln EXISTING APPROVED rA � OI 1/4"-1' SLOPE (MIN.)ii X X '�/ 0 2X2 pJ =li (FL.#21443-R1) i;�l CIA INSULATED INSULATED ROOF L.D N I 1X2 1 8' 6" 0-36" O/H (MAX.) 13'-0" 14'-0" 2X3 I 2X3 m m m a � N x X m N 0o N 16"X.024" 2X2 TYP. � 1X2 TYP. KP TYP. o LL =Z:C/) o- O =�:z LLI CDw v� 0 v~, ��: O\ j el c9 W O 024 FLASHING SEALED TO WALL (TYP.) #14x1/2"S.M.S.W/INTEGRAL 3/4"0WASHER AND NEOPRENE GASKET @ 12" O.C., TOP & BOTTOM. O O O IF CLEARANCE PROHIBITS INSTALLATION OF TOP FASTENERS USE # 14x4" S.M.S. W/ 1-1/4" O FENDER WASHER AND NEOPRENE GASKET @ 12' O.C. s (3) PER PAN FOR PANS EXTRUDED OR BRAKE -FORMED ROOF HEADER OR RECEIVING CHANNEL (0.044" MIN. THICKNESS) WITH MIN. 1-1/2' BEARING LEG. HOST STRUCTURE 1 /4" O x 2-1/2" LONG WOOD LAG SCREW OR MASONRY OR WOOD 1/4" O x 2-1/4' LONG MASONRY ANCHORS @ 24" O.C. MAX. ROOF PANEL ATTACHMENT - MASONRY SCALE: N.T.S. Z W Q4: � N LL = Z: O O OR TRU EXISTIN*SCREWS # 14x1 /2" S.M.S. W/ INTEGRAL 3/4" O # 14x4" S.M.S. w/ 1-1/4" d FENDER WASHER AND NEO-PRENE GASKET @ 12' O.C.WASHER = ; Z W W el AND NEOPRENE GASKET - C; O ' U ¢ _ E@ 12" O.C., TOP &BOTTOM (3) PER PAN FOR PANS# 12 X 9PANW/ R P NEO-WASHER PER PAN FOR PANSON = z �(3) tV TRUDED OR BRAKE -FORMED ROOF HEADER RECEIVING CHANNEL (0.044" MIN. THICKNESS) ROOF PER PLAN �i .,, !I V � w TH MIN. 1-1/2' BEARING LEG. � COVER END OF PANEL �j (••••• �1LONG SECURE FASCI //\\\\\\\ mLLj TAIL W/ (LAx V Q PAN HADRAFTER BEFORE ATTACHING REC. CHANNEL 2' LAG SCREW @ 24" O.C. ENTIRE LENGTH OF RECEIVING CHANNEL ROOF PANEL ATTACHMENT - WOOD FRAME 3" X 2" X .050" MIN. (SEE PLAN) co SCALE: N.T.S. o Lo ROOF PANEL TO CARRIER BEAM J r `q CONNECTION SCALE: N.T.S. ... I— rrnn ALUMINUM INTERNAL OR EXTERNAL RECEIVING CHANNELw/(4) #IOx.75" INTO GIRT OR PURLIN & (2) # 14x.75" 4 #1 Oxl-1/2' SMS INTO INTO BEAM OR UPRIGHT 0.062 ANGLE () CLIPS MAYBE USED SCREW BOSSES PURLIN MEMBER UPRIGHT, BEAM -SNAP, SELF MATING, OR HOLLOW DETAIL "C" - GIRT OR PURLIN TO BEAM OR POST DETAIL SCALE: NTS 1 /8'k2k2k ANGLE SELF -MATING OR 5032 H-32 ANGLE SNAP SECTION TYP. (2) - #12 SMS INTO COLUMN 1 /4" MASONRY ANCHOR EACH 1'k2' O.B. BASE PLATE-TYP. ANGLE - EACH SIDE COL. o 0 0 0 1-1/4" MIN. CONC. � ANCHOR EMBEDMENT 2-1/4" MIN. CONC. ANCHOR EMBEDMENT ` SECONDARY ANGLE a� a 3000 PSI CONC. SLAB/FTG. 6x6-10x10 WWM OR FIBERMESH 1 /4" MASONRY ANCHOR AT EACH ANGLE 2-1/4" MIN. CONC. ANCHOR EMBEDMENT SECONDARY ANGLE SIDE VIEW 2' MIN. INCREASE DISTANCE WHEN GREATER THAN 2x4 UPRIGHT IS USED (2) - # 12 SMS 1 /4' TAPCON XL (RED HEAD MFG. OR EQUAL) 2 @ 1 x2 BASE 2 @ SLAB (BEYOND) ° ,__ 1"x2' BASE PLATE ANCHORED o ° n TO CONC w/ 1 /4" MASONRY ANCHOR 6" MAX EACH SIDE OF POST AND 24" O.C. MAX 1-1 /4" CONC. EMBEDMENT TYP. 6" ° NOTE 3000 PSI CONC. WHERE PAVERS ARE PRESENT USE 5/16" SLAB/ FTG. TAPCON XL (RED HEAD MFG.) MASONRY 6x6-1Ox10 WWM FRONT VIEW ANCHORS TO PENETRATE UNDERLYING OR FIBERMESH CONCRETE FOOTING 2-1/4" (MIN.) DETAIL "B" - 2"x4" OR LARGER SELF MATING UPRIGHT TO DECK DETAILS SCALE: NTS ANCHORING UPRIGHT TO FOUNDATION NOTES: 1.- IF PAVERS ARE PRESENT, CONCRETE ANCHORS SHALL PENETRATE INTO FOOTING 2-1/4" MIN. (TYP.) 2.- WHEN FASTENING TO WOOD USE 1 /4" GALV. LAG SCREW IN LIEU OF CONC. ANCHORS AND ENSURE 2-1/4" MIN. PENETRATION INTO STRUCTURAL FRAMING BENEATH (TYP.) 3.- NO SECONDARY ANGLE REQUIRED FOR 2X3 UPRIGHTS OR DOOR JAMBS. FASTEN TOP OF HEADER TO INTERSECTING MEMBER w/ (4) #10 SMS (INTERNAL),2' MIN. INTO SCREW BOSS OF INTERSECTING MEMBER 3X2 EDGE BEAM 2'50K&kl/8" ANGLE W/ II II (2) # 10 x 3/4" SMS INTO EDGE BEAM (2) # 10 x 3/4" SMS INTO POST II II (NO ANGLE REQUIRED UNLESS EDGE CENTRAL COLUMN SIZE PER PLAN II ii II II BEAM SPLICED OR CORNER ATTACHMENT) CORNER COLUMN II II SIZE PER PLAN C 2"X2"Xl/8" ANGLE CUTTO FIT W/ (3) #12x.75" EACH LEG EACH SIDE OF UPRIGHTTYP. SEE UPRIGHTTO DECK CONNECTION DETAIL 2X3/ 2X4 COL. TO 2X3/ 2X4 EDGE BEAM CONNECTION SCALE: N.T.S. #14x4" S.M.S. w/ 1-1/4" 0 FENDER WASHER AND NEO-PRENE GASKET @ 12" O.C. •• E �2"X2"Xl/8"ANGLE #14x4"S.M.S. w/1-1/4"0 FENDER WASHER CUT TO FIT AND NEO-PRENE GASKET @ 24" O.C. w/#12x.75" @ 1" SPACING MAX. (4) PER LEG (MIN.) EACH SIDE TYP. FOR NON -LOAD BEARING WALLS ALTERNATELY CLIPS MAYBE USED 1/4" DIA. TAPCON 6" FROM ENDS PRIMARY UPRIGHT PER PLAN SIDE WALL UPRIGHT 24" 0,C. MAX 1-1/4" EMBEDMENT PER PLAN INTO UNDERLYING CONC. ALUMINUM INTERNAL OR EXTERNAL RECEIVING CHANNEL w/(4) #10x.75" INTO GIRT OR PURLIN & (2) #14x.75" INTO BEAM OR UPRIGHT 0.062 ANGLE (4) #lOx2" SMS INTO SCREW BOSSES CLIPS MAYBE USED MAYBE CHAIR RAIL PER PLAN "ANGLE REQUIRED ONE SIDE ONLY W HERE KICK PLATE IS INDICATED AT CORNER AND DOOR OPENINGS FASTEN W/ #10 X 9/16" SMS 6" FROM CORNERS 18" IN FIELD (2) #lOx2" SMS INTO 1/4" DIA. TAPCON 6" FROM ENDS OR FASTEN W/ #8 X 9/16" SMS SCREW BOSSES OR 24" O.C. MAX 1-1/4" EMBEDMENT 2" FROM CORNERS 8" IN FIELD CLIPS MAY BE USED INTO UNDERLYING CONC. 4 FOUNDATION PER PLAN �+ SCREEN ROOM END WALL DETAIL SCALE: N:iZ9 Fm 26GA FLASHING W/ #8 SMS 6" O/C ROOF PER PLAN CARRIER BEAM PER PLAN 3X3 OR 4X4 POST PER PLAN # 14x4" S.M.S. w/ 1-114" 0 FENDER WASHER AND NEO-PRENE GASKET @ 12" O.C. ROOF PER PLAN (2) 3/8" THRU-BOLT `FOR SMB SEE BEAM TO COL. CONNECTION FRONT VIEW ROOF PANEL TO BEAM OPTION #1 CONNETION DETAIL SCALE: N.T.S. 1"x2" FASTEN TO COL. (INTERNAL) w/(2) #10xl-1/2' SMS, FASTEN TO EA V E RAILS ABOVE w/# 10 1-1 /2' SMS 24" O.C. AND 6" WITHIN COL. TABLE "D" BEAM QTY/ SIZE EACH SIDE 2x3 (4)/#12 2x4 (5)/#12 2x5 (5)/ #12 2x6 (6)/#12 2x7 (7)/#12 2x8 (8)/#14 2x9 (9)/ #14 2x 10 (9)/ #14 26GA FLASHING W/ #8 SMS 6" O/C ROOF PER PLAN CARRIER BEAM — PER PLAN 3X3 OR 4X4 POST PER PLAN EXTRUDED OR BRAKE -FORMED ROOF HEADER OR RECEIVING CHANNEL (0.044" MIN. THICKNESS) WITH MIN. 1-1 /2" BEARING LEG. W/ #12x3/4" S.M.S. W/ INTEGRAL 3/4"0 WASHER AND NEOPRENE GASKET @ 12" O.C., TOP & BOTTOM (2) # 12x3/4" SMS @ 12" O.C. INTO RIDGE BEAM PER PLAN ROOF PER PLAN (2) 3/8" THRU-BOLT 'FOR SMB SEE BEAM TO COL. CONNECTION FRONT VIEW ROOF PANEL TO BEAM OPTION #2 CONNETION DETAIL SCALE: N.T.S. o ° BEAM PER PLAN ° (SLOPED OR FLAT) o 0 o \—BEAM PER PLAN NOTCHED TO RECEIVE COLUMN WITHIN SMS, (EACH SIDE) o QTY/ SIZE PER TABLE "D" POST (SEE PAGE FOR SIZE) NOTCH PROFILE MAY VARY TO PERMIT CORRECT # SMS rni i i�eni oG° ci eni q / � MAINTAIN MIN, OF 5/8" SEPERATION FROM EDGE OF BEAM SMS O.C. DETAIL E - UPRIGHT TO BEAM CONNECTION SCALE: NTS 0 2"X2'X.125" ANGLE W/ #14x3/4" THRU ANGLE LEG INTO BEAM EA. SIDE TYP. SEE TABLE FOR QUANTITY 2"X2'X.125" ANGLE W/ (3) 1 /4" X 2-1/4" TAPCONS @ 2" o.c. THRU ANGLE LEG INTO HOST WALL TOP VIEW BEAM PER PLAN (2X7SMB ILLUSTRATED) ° 2"X2"X.125"ANGLEW/ ° # 1 4x3/4" THRU ANGLE LEG INTO BEAM EA. SIDE TYP. SEE TABLE FOR QUANTITY ° 2"X2'X.125" ANGLE W/ FASTENER NOTES: MAINTAIN 1/2" SEPARATION BETWEEN FASTENERS. MAINTAIN 3/8" MIN, FASTENER SEPARATION FROM EDGE. FASTENERS MAY BE STAGGERED TO ENSURE PROPER QUANTITY PERMITTED (PATTERN MAY APPEAR DIFFERENT FROM ILUSTRATION) BEAM TO WALL w/ 1 /8" ANGLE TABLE BEAM SIZE QUANTITY/ SIZE PER LEG TO BEAM QUANTITY ANCHOR PER LEG TO WALL 2X4 (4) #12-(2) #16 (2) 1/4"TAPCON 2X5 (5) # 12 - (3) # 16 (2) 1 /4' TAPCON 2X6 (5) # 12 - (3) #16 (3) 1 /4" TAPCON 2X7 (6) # 14 - (4) # 16 (3) 1 /4' TAPCON 2X8 (7) # 14 - (4) # 16 (4) 1 /4" TAPCON 2X9 (8) # 14 - (5) # 16 (4) 1 /4' TAPCON 2X10 (9) #14-(6) #16 (5) 1/4"TAPCON (3) 1 /4" X 2-1/4" TAPCONS @ 2' o.c. THRU ANGLE LEG INTO HOST WALL SIDE VIEW BEAM TO HOST WALL CONNECTION SCALE: N.T.S. "MAY USE: (2) 3/8" DIA. #14x3/4"SMS MACHINE BOLTS THRU QUANTITY = SEE TABLE REC. CHANNEL & POST I IN LIEU OF #14 SMS 0 0 CARRIER BEAM 0 1 PER PLAN # 14x3/4"SMS QUANTITY = SEE TABLE (TYP. EACH SIDE) "MAY USE: (2) 3/8" DIA. MACHINE BOLTS THRU REC. CHANNEL & BEAM IN LIEU OF #14 SMS BEAM TO COLUMN w/ RECEIVER TABLE BEAM SIZE LEG QUAA(3) QUANTITY/SIZE TO COL. INTERNAL 2X4 (4) (8) #12-(3) #16 2X5 (5) (10) #12-(3) #16 2X6 (5) (10) #12-(4) #16 2X7 (6) #14-(4) #16 (12) #14-(4) #16 2X8 (7) #14-(4) #16 (12) #14-(6) #16 2X9 (8) #14-.(5) #16 (14) #14-(6) #16 2X10 (9) #14-(6) #16 (14) #14-(7) #16 BEAM TO COLUMN CONNECTION DETAIL SCALE: N.T.S. \\ N O co Q�, ••7C/ N LL =Z:aJ O O O: LLI d POV —� w CD W �: Uco Q O: z- N Pi 0 ' co O < LLI , //111111111\\ co a �