HomeMy WebLinkAbout10-13-20 unico color chart.r L.C.�T 'S1P� �c:��-rJATIo� Ye ` O tt- •0 COLOR CHART MAIN BODY SHERW IN WILLIAMS SEA SALT #SW6204 STUCCO BANDS &TRIM SHERWIN WILLIAMS WHITE ROOF &ROLL UP DOORS GALVALUME MILL FINISH FOUNDATION SCHEDULE S-1 4" (3000 PSI) POURED CONCRETE SLAB WITH FIBERMESH REINFORCING ON .006"VAPOR BARRIER'OVER CLEAN COMPACTED TREATED FILL. F-1 12" X 12" THICKENED EDGE WITH 1 # 5 BAR CONTINUOUS. F-2 16" DEEP X 16" WIDE MONOLITHIC FOOTING WITH 2 # 5 BARS CONTINUOUS. F-2 16" DEEP X 24" WIDE MONOLITHIC FOOTING WITH 3 # 5 BARS CONTINUOUS. CONNECTOR ct NFnf ff F TRUSS ID BEARING TRUSS ACFUAL SIMPSON CONNECTORS) FASTENERS POINTS) UPLIFT (GROUPED, CONNECTORS) UPLIFT DESIGN WORST CASE) A EACH 3024q (1) HETA 20 1810R 9-lOdxi-3/2" B EACH 1920M (2) HETA 20 2SOON 16-lOdxl-i(2" KING JACK 1" BRG 743N (1)HETA 20 3830q 9-10dx1-3/2" 2N0 BRG 593tt (i)MT516 IOOOR 14-SOdxl-1/2" HIPIACKS 1sT BRG 187N (1)HETA 20 1810k 9dOdxi-i/2" 2N° BRG NAILED PER TRUSS COMPANY ZZ'_-�.� S.V��'1 t tea Ca F'f_../�1`� v�„ Coo'-o" 151- o" �O�NPs�I �OtiJ 1�L.<o-�/� )�8 n �: ARCHITECT Architectonic Inc 806 DELAWARE AVENUE FORT PIERCE, FLORIDA 34950 T: 772 460 7751 F: 772 460 4244 WW W.ARCHITECTONICINC.COM STATE REG # AA26003348 COPYRIGHT 2020 PROJECT UNICO AIR CONDITIONING ST. LUCIE COUNTY CLIENT CONSULTANTS REGISTRATION �- :- ,C;RiD� � .. p' ` �' <. v ,�`��� (v��� r" a'. V`��e�l �b�, n'•. c: �r�``��GI SyyT �� �'�l�- MICH%�E:`LZJ:�SEAL, AIA AR96898 REVISIONS NO. DATE REVISION ( f C fSC� A /5E4� EI..EV. rt. aP9 CoT•+�� CLk Pa 'L� KEY PLAN SHEET TITLE /SHEET NUMBER .. _�- of NUMBER C Lo 00 IPROJECT DATE 2�2to�2o �'r. x�t.t � t-