Loading...
HomeMy WebLinkAboutEnergy CodeDepartment of Community Affairs SN: 5077 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION FORM 60OA-93 Residential Component Prescriptive Method A CENTRAL PROJECT NAME: EILEEN ISLE-4 BDRM ;BUILDER: MERCEDES HOMES AND ADDRESS: ;PERMITTING ;CLIMATE ;OFFICE: ;ZONE: 41_; 51_1 6;_; OWNER: ;PERMIT NO. ;JURISDICTION NO. CK 1. New construction.or addition 1. New Construction 2. Single family detached or Multifamily attached 2. Single -Family 3"." If Multifamily -No. of units 3. 0 4. If Multifamily, is this a worst case (yes/no) 4. 5. Conditioned floor area (sq.ft.) '5. 2092.00 6.'Predominant save overhang (ft.) 6. 1.50 7. Porch overhang length (ft.) 7. 15.00 S. Glass area and type: Single Pane Double Pane a. Clear Glass 8a.293.Osgft O.00sgft b. Tint, film or solar screen 8b. O.Osgft O.00sgft 9. Floor type and insulation: a. Slab on grade (R-value, perimeter) 9a.R= 0.00 , 201.25 ft 1O.Net Wall type area and insulation: a. Exterior: 1. Concrete (Insulation R-value) 10a-1 R= 3.85, 1173.00sgft a. Exterior: 2. Wood frame (Insulation R-value)-10a-2 R=11.00, 59.00sgft a. Adjacent: 2. Wood frame (Insulation R-value) 10a-2 R=11.00, 255.00sgft 11.Ceiling type area and insulation: a. Under attic (Insulation R-value) 11a.R=19.00 , 2401.00sgft . 12.Air distribution systems a. Ducts (Insulation + Location) 1`2a. R= 6.00 uncond 13.Cooling system 13. Type: Central A/C SEER: 10.00 14.Heating System: 14. Type: Heat Pump HSPF: 6.80 15.Hot water system: 15. Type: Electric EF: 0.94 16.Hot Water Credits: (HR-Heat Recovery, 16. DHP-Dedicated Heat Pump) 17.Infiltration practice: 1, 2 or 3 17. .2 18.HVAC Credits (CF-Ceiling Fan, CV -Cross vent, 18. HF-Whole house fan, RB-Attic radiant. barrier, MZ-Multizone) 19..EPI (must not exceed 100 points) 19. 88.32 a. Total As_Built points 19a. 37428.36, b. Total Base points 19b. 42378.44 ------------------------------------------------------------------------------- I' Hereby certify that the plans and ; Review of.the plans and specifications specifications covered by this calcu- 14tion are in compliance with the Florida Ener ode. PREPARED RY"K kra 9- DATE: I hereby certify that this building is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance in accordance with Section 553.908 F.S. BUILDING OFFICIAL: DATE: SUMMER CALCULATIONS BASE ___ ; __= AS -BUILT GLASS---------------- ORIEN AREA x BSPM = POINTS ------------------------------------------------------------------------------- ; TYPE SC ORIEN AREA x SPM x SOF = POINTS N 16.00 82.2 1315.2.; SGL CLR N 16.0 51.0 .B6 699.0 E 87.50 62.2 7192.5 ; SGL CLR E 15.0 109.2 .87 1417.8 SGL CLR E 30.0 109.2 .87 2835.6 SGL CLR E 12.5 109.2 .52 709.8 SGL CLR E 30.0 109.2 .87 2835.6 S. 70.50 82.2 5795.1 ; SGL CLR' S 40.5 100.2 .40 1605.9 SGL CLR S 15.0 100.2 .79 1190.7 SGL CLR S 15.0 100.2 .79 1190.7 W 119.00 .82.2 9781.8 ; SGL CLR W 15.0 109.2 .87 1417.8 SGL CLR W 15.0 109.2 .87 1417.8 SGL CLR W 15.0 109.2 .35 580.6 SGL CLR W 10.0 109.2 .32 346.2 SGL CLR W 10.0 . 109.2 .29 314.7 ------------------------------------ SGL CLR W 54.0 109.2 .31 1807.4 -------------------------------------- .15 x COND. FLOOR / TOTAL GLASS = ADJ. x GLASS = ADJ GLASS ; GLASS AREA AREA ------------------------------------------------------------------------------- FACTOR POINTS POINTS ; POINTS .15 2,092.00 293.00 1.071 24,084.60 25,794.36 ; 18,369.55 NON GLASS------------ ' AREA x BSPM = POINTS ------------------------------------------------------------------------------- ; TYPE R-VALUE AREA x SPM = POINTS WALLS---------------- Ext 1232.0 1.0 1232.0 ; Ext NormWtBlock In 3.8 1173.0 1.23 1442.8 Ext.Wood Frame 11.0 59.0 1.90 112.1 Adj 255.0 .7 178.5 ; Adj Wood Frame- 11.0 255.0 .70 178.5 DOORS ---------------- Ext 59.5 4.8 285.6 ; Ext Insulated 40.5 4.80 194.4 Ext Insulated 19.0 4.80 91.2 Adj 19.0 1.6 30.4 ; Adj Insulated 19.0 1.60 30.4 CEILINGS-------.---- i UA 2001.0 .6 1200.6 ; Under Attic .19.0 917.0 1.10 1008.7 Under Attic 19.0 '1484.0 1.10 1632.4 FLOORS--------------- ' S1b 201.3 -31.8-6399.8 ;'Slab -on -Grade .0 201.3 -31.90 -6419.9 INFILTRATION--------- ; 2092.0 10.9 22802.8 ; Practice #2 �, 2092.0 10.90 22802.8 --------------------------------------------------- TOTAL SUMMER POINTS ' '45,124.51 ; 39,442.97 TOTAL x SYSTEM = COOLING ; TOTAL x CAP x DUCT x SYSTEM x CREDIT = COOLING SUM PTS MULT,:-,POINTS -------------------- ; COMPON RATIO MULT MULT MULT POINTS ----------------------------------------------------------- 45,124.51 .37 16,696.07 ;• 39,442.97 1.00 1.100 .340 1.-000' 14,751.67 WATER HEATING BASE ___ ; __= AS -BUILT NUM OF x MULT = TOTAL !-TANK VOLUME EF TANK 'x MULT x CREDIT = TOTAL BEDRMS ; RATIO MULT ------------------------------------------------------------------------------- 14 3527.0 14,108.00 ; 40 .94 1.000 3302.0 1.00 13,208.00 - ------------------------------------------------------------------=----------- ------------------------------------------------------------------------------- SUMMARY BASE ___ ; __= AS -BUILT COOLING HEATING HOT WATER TOTAL. ; COOLING HEATING,* HOT WATER TOTAL POINTS + POINTS + POINTS = POINTS ; POINTS + POINTS + POINTS = POINTS ----------- ----------------------------------------------------------- --------- 16696.1 11574.4 14108.0 42,378.44 ; 14751.7 9468.7 13208.0 37,428.36 ------------------------------------------------------------------------------- * EPI = 88.32 WINTER CALCULATIONS BASE __= i =_= AS -BUILT GLASS ---------------- ORIEN AREA x BWPM = POINTS ; TYPE SC ORIEN AREA x WPM x WOF = POINTS ------------------------------------------------------------------------------- N 16.00 -,3.4 -54.4 ; SGL CLR N' 16.0 9.6 1.09 166.9 E 87.50 -3.4 -297.5 ; SGL CLR E 15.0 -2.2 .27 -9.1 SGL CLR E 30.0 -2.2 .27 -18.1 SGL CLR E 12.5 -2.2 -2.03 55.8 SGL CLR E 30.0 -2.2 .27 -18.1 S. 70.50 -3.4 -239.7 ; SGL CLR S 40.5 -10.9 -.11 46.4 SGL CLR S 15.0 -10.9 .85 -139.0 SGL CLR S 15.0 -10.9 .85 -139.0 W 119.00 -3.4 -404.6 ; SGL CLR W 15.0 -2.2 .27 -9.1 SGL CLR W 15.0 -2.2 .27 -9.1 SGL CLR W 15.0 -2.2 -3.77 124.6 SGL CLR W 10.0 -2.2 -4.24 93.3 SGL CLR W 10.0 -2.2 -4.65 102.2 SGL CLR W 54.0 -2.2 -4.39 521.4 ------------------------------------------------------------------------------- .15 x COND. FLOOR / TOTAL GLASS = ADJ. x GLASS = ADJ GLASS. ; GLASS AREA AREA FACTOR POINTS POINTS ---------------------- ; POINTS ----------------------------------------------------------- .15 2,092.00 293.00 1.071 -996.20 -1,066.92 ; 769.29 NON GLASS------------ ' AREA x BWPM = POINTS ; TYPE R-VALUE AREA x WPM = POINTS ------------------------------------------------------------------------------- WALLS---------------- ; Ext 1232.0 1.1 1355.2 ; Ext NormWtBlock In 3.8 1173.0 3.42 4008.7 Ext Wood Frame 11.0 59.0 2.00 118.0 Adj 255.0 1.8 459.0 ; Adj Wood Frame 11.0 255.0 1.80 459.0 DOORS---------------- ' Ext 59.5 5.1 303.4 ; Ext Insulated 40.5 '5.10 206.6 Ext Insulated 19.0 5.10 96.9 Adj 19.0 4.0 76.0 ; Adj Insulated 19.0 4.00 76.0 CEILINGS------------- ' UA 2001.0 .6 1200.6 ; Under Attic 19.0 917.0 1.00 917.0 Under Attic 19.0 1484.0 1.00 1484.0 FLOORS --------------- S-1b 201.3 -1.9 -382.4 ; Slab -on -Grade. .0 201.3 2.50 503.1 INFILTRATION--------- 2092.0 4.1 8577.2 ; Practice #2 2092.0 4.10 8577.2 TOTAL WINTER POINTS 10,522.16 ; 17,215.79 TOTAL x SYSTEM =� HEATING ; TOTAL x CAP x DUCT x SYSTEM x CREDIT = HEATING WIN PTS MULT POINTS ; COMPON RATIO MULT MULT MULT POINTS ------------------------------------------------------------------------------- 10,522.16 1.10 11,574.37 1 17,215.79 1.00 1.106 .500 1.000 9,468.69 . ENERGY GUIDE For detailed information of the EPI rating number or for any ITEM listed, ask your Builder for EPI= 88.3 DCA Form 60OA-93 or Form 600E-93 0 10 20 30 40 50 60 70 80 90 100 '-----------------------------------X----- The maximum allowable EPI is 100. The lower the'EPI the more efficient the home RESIDENTIAL ENERGY PERFORMANCE RATING SHEET ITEM HOME VALUE Low Efficiency High Efficiency SINGL CLR DBL TINT WINDOWS ....................:Single Clear ;X-------------------- INSULATION .................. Ceiling R-Value......... 19.0 Wall R-Value......... 5.4 'Floor R-Value......... 0.0 AIR CONDITIONER ............. SEER/EER...................10.0 HEATING SYSTEM .............. Electric COP/HSPF........ 6.8 Gas AFUE............ 0.00 WATER HEATER ................ Electric EF.............. Gas EF.............. Solar EF.............. OTHER FEATURES .............. R-10 R-30 ---------X----------- R-0 R-7 --------------- X ----- ; R-0 R-19 X--------------------� 10.0 SEER 17.0 X--------------------; 9.7 EER 16.0 6.8 HSPF 12.0 1X-------------------- 0.78 AFUE 0.90 '------------------- ' 0.88 0.96 0.94 ;---------------X----- 0.54 .0.90 0.00 ;------ =-------------- 0.40 0.80 ---------------------; I certify that these energy saving features required for the Florida Energy Code have been installed in this house. Builder Address: Signature: Date: City/Zip Florida Energy Code for Building Construction'- 1993 Florida Department of Community Affairs FL-EPL CARD93