HomeMy WebLinkAboutEnergy CodeDepartment of Community Affairs SN: 5077
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
FORM 60OA-93 Residential Component Prescriptive Method A CENTRAL
PROJECT NAME: EILEEN ISLE-4 BDRM ;BUILDER: MERCEDES HOMES
AND ADDRESS: ;PERMITTING ;CLIMATE
;OFFICE: ;ZONE: 41_; 51_1 6;_;
OWNER: ;PERMIT NO. ;JURISDICTION NO.
CK
1. New construction.or addition 1. New Construction
2. Single family detached or Multifamily attached 2. Single -Family
3"." If Multifamily -No. of units
3. 0
4. If Multifamily, is this a worst case (yes/no)
4.
5. Conditioned floor area (sq.ft.)
'5. 2092.00
6.'Predominant save overhang (ft.)
6. 1.50
7. Porch overhang length (ft.)
7. 15.00
S. Glass area and type:
Single Pane Double Pane
a. Clear Glass
8a.293.Osgft O.00sgft
b. Tint, film or solar screen
8b. O.Osgft O.00sgft
9. Floor type and insulation:
a. Slab on grade (R-value, perimeter)
9a.R= 0.00 , 201.25 ft
1O.Net Wall type area and insulation:
a. Exterior: 1. Concrete (Insulation R-value)
10a-1 R= 3.85, 1173.00sgft
a. Exterior: 2. Wood frame (Insulation R-value)-10a-2
R=11.00, 59.00sgft
a. Adjacent: 2. Wood frame (Insulation R-value)
10a-2 R=11.00, 255.00sgft
11.Ceiling type area and insulation:
a. Under attic (Insulation R-value)
11a.R=19.00 , 2401.00sgft .
12.Air distribution systems
a. Ducts (Insulation + Location)
1`2a. R= 6.00 uncond
13.Cooling system
13. Type: Central A/C
SEER: 10.00
14.Heating System:
14. Type: Heat Pump
HSPF: 6.80
15.Hot water system:
15. Type: Electric
EF: 0.94
16.Hot Water Credits: (HR-Heat Recovery,
16.
DHP-Dedicated Heat Pump)
17.Infiltration practice: 1, 2 or 3
17. .2
18.HVAC Credits (CF-Ceiling Fan, CV -Cross vent,
18.
HF-Whole house fan, RB-Attic radiant.
barrier, MZ-Multizone)
19..EPI (must not exceed 100 points)
19. 88.32
a. Total As_Built points
19a. 37428.36,
b. Total Base points
19b. 42378.44
-------------------------------------------------------------------------------
I' Hereby certify that the plans and ; Review of.the plans and specifications
specifications covered by this calcu-
14tion are in compliance with the
Florida Ener ode.
PREPARED RY"K kra 9-
DATE:
I hereby certify that this building is
in compliance with the Florida Energy
Code.
OWNER/AGENT:
DATE:
covered by this calculation indicates
compliance with the Florida Energy
Code. Before construction is completed
this building will be inspected for
compliance in accordance with Section
553.908 F.S.
BUILDING OFFICIAL:
DATE:
SUMMER CALCULATIONS
BASE ___
; __= AS -BUILT
GLASS----------------
ORIEN AREA x BSPM = POINTS
-------------------------------------------------------------------------------
; TYPE SC ORIEN
AREA
x SPM
x SOF
= POINTS
N 16.00 82.2 1315.2.;
SGL CLR N
16.0
51.0
.B6
699.0
E 87.50 62.2 7192.5
; SGL CLR E
15.0
109.2
.87
1417.8
SGL CLR E
30.0
109.2
.87
2835.6
SGL CLR E
12.5
109.2
.52
709.8
SGL CLR E
30.0
109.2
.87
2835.6
S. 70.50 82.2 5795.1
; SGL CLR' S
40.5
100.2
.40
1605.9
SGL CLR S
15.0
100.2
.79
1190.7
SGL CLR S
15.0
100.2
.79
1190.7
W 119.00 .82.2 9781.8
; SGL CLR W
15.0
109.2
.87
1417.8
SGL CLR W
15.0
109.2
.87
1417.8
SGL CLR W
15.0
109.2
.35
580.6
SGL CLR W
10.0
109.2
.32
346.2
SGL CLR W
10.0
. 109.2
.29
314.7
------------------------------------
SGL CLR W
54.0
109.2
.31
1807.4
--------------------------------------
.15 x COND. FLOOR / TOTAL GLASS = ADJ. x GLASS
= ADJ GLASS ;
GLASS
AREA AREA
-------------------------------------------------------------------------------
FACTOR POINTS
POINTS
;
POINTS
.15 2,092.00 293.00
1.071 24,084.60
25,794.36 ; 18,369.55
NON GLASS------------
'
AREA x BSPM = POINTS
-------------------------------------------------------------------------------
; TYPE R-VALUE
AREA
x SPM
= POINTS
WALLS----------------
Ext 1232.0 1.0 1232.0
; Ext NormWtBlock In
3.8
1173.0
1.23
1442.8
Ext.Wood Frame
11.0
59.0
1.90
112.1
Adj 255.0 .7 178.5
; Adj Wood Frame-
11.0
255.0
.70
178.5
DOORS ----------------
Ext 59.5 4.8 285.6
; Ext Insulated
40.5
4.80
194.4
Ext Insulated
19.0
4.80
91.2
Adj 19.0 1.6 30.4
; Adj Insulated
19.0
1.60
30.4
CEILINGS-------.----
i
UA 2001.0 .6 1200.6
; Under Attic .19.0
917.0
1.10
1008.7
Under Attic
19.0
'1484.0
1.10
1632.4
FLOORS---------------
'
S1b 201.3 -31.8-6399.8
;'Slab -on -Grade
.0
201.3
-31.90
-6419.9
INFILTRATION---------
;
2092.0 10.9 22802.8
; Practice #2
�,
2092.0
10.90
22802.8
---------------------------------------------------
TOTAL SUMMER POINTS
'
'45,124.51
;
39,442.97
TOTAL x SYSTEM = COOLING
; TOTAL x CAP x DUCT
x SYSTEM
x CREDIT =
COOLING
SUM PTS MULT,:-,POINTS
--------------------
; COMPON RATIO MULT
MULT
MULT
POINTS
-----------------------------------------------------------
45,124.51 .37 16,696.07
;• 39,442.97 1.00 1.100
.340 1.-000' 14,751.67
WATER HEATING
BASE ___ ; __= AS -BUILT
NUM OF x MULT = TOTAL !-TANK VOLUME EF TANK 'x MULT x CREDIT = TOTAL
BEDRMS ; RATIO MULT
-------------------------------------------------------------------------------
14 3527.0 14,108.00 ; 40 .94 1.000 3302.0 1.00 13,208.00
-
------------------------------------------------------------------=-----------
-------------------------------------------------------------------------------
SUMMARY
BASE ___ ; __= AS -BUILT
COOLING HEATING HOT WATER TOTAL. ; COOLING HEATING,* HOT WATER TOTAL
POINTS + POINTS + POINTS = POINTS ; POINTS + POINTS + POINTS = POINTS
----------- ----------------------------------------------------------- ---------
16696.1 11574.4 14108.0 42,378.44 ; 14751.7 9468.7 13208.0 37,428.36
-------------------------------------------------------------------------------
* EPI = 88.32
WINTER CALCULATIONS
BASE __= i =_= AS -BUILT
GLASS ----------------
ORIEN AREA x BWPM = POINTS ; TYPE SC ORIEN AREA x WPM x WOF = POINTS
-------------------------------------------------------------------------------
N 16.00 -,3.4
-54.4
;
SGL CLR
N'
16.0
9.6
1.09
166.9
E 87.50 -3.4
-297.5
;
SGL CLR
E
15.0
-2.2
.27
-9.1
SGL CLR
E
30.0
-2.2
.27
-18.1
SGL CLR
E
12.5
-2.2
-2.03
55.8
SGL CLR
E
30.0
-2.2
.27
-18.1
S. 70.50 -3.4
-239.7
;
SGL CLR
S
40.5
-10.9
-.11
46.4
SGL CLR
S
15.0
-10.9
.85
-139.0
SGL CLR
S
15.0
-10.9
.85
-139.0
W 119.00 -3.4
-404.6
;
SGL CLR
W
15.0
-2.2
.27
-9.1
SGL CLR
W
15.0
-2.2
.27
-9.1
SGL CLR
W
15.0
-2.2
-3.77
124.6
SGL CLR
W
10.0
-2.2
-4.24
93.3
SGL CLR
W
10.0
-2.2
-4.65
102.2
SGL CLR
W
54.0
-2.2
-4.39
521.4
-------------------------------------------------------------------------------
.15 x COND. FLOOR / TOTAL
GLASS
= ADJ. x GLASS
=
ADJ GLASS.
;
GLASS
AREA
AREA
FACTOR POINTS
POINTS
----------------------
;
POINTS
-----------------------------------------------------------
.15 2,092.00
293.00
1.071
-996.20
-1,066.92
;
769.29
NON GLASS------------
'
AREA x BWPM =
POINTS
;
TYPE
R-VALUE
AREA
x WPM
= POINTS
-------------------------------------------------------------------------------
WALLS----------------
;
Ext 1232.0 1.1
1355.2
;
Ext NormWtBlock
In
3.8
1173.0
3.42
4008.7
Ext Wood Frame
11.0
59.0
2.00
118.0
Adj 255.0 1.8
459.0
;
Adj Wood Frame
11.0
255.0
1.80
459.0
DOORS----------------
'
Ext 59.5 5.1
303.4
;
Ext Insulated
40.5
'5.10
206.6
Ext Insulated
19.0
5.10
96.9
Adj 19.0 4.0
76.0
;
Adj Insulated
19.0
4.00
76.0
CEILINGS-------------
'
UA 2001.0 .6
1200.6
;
Under Attic
19.0
917.0
1.00
917.0
Under Attic
19.0
1484.0
1.00
1484.0
FLOORS ---------------
S-1b 201.3 -1.9
-382.4
;
Slab -on -Grade.
.0
201.3
2.50
503.1
INFILTRATION---------
2092.0 4.1
8577.2
;
Practice #2
2092.0
4.10
8577.2
TOTAL WINTER POINTS
10,522.16
;
17,215.79
TOTAL x SYSTEM =�
HEATING
;
TOTAL x CAP
x DUCT
x SYSTEM
x CREDIT
= HEATING
WIN PTS MULT
POINTS
;
COMPON RATIO
MULT
MULT
MULT
POINTS
-------------------------------------------------------------------------------
10,522.16 1.10 11,574.37
1
17,215.79 1.00
1.106
.500 1.000
9,468.69
. ENERGY GUIDE
For detailed information
of the EPI rating number
or for any ITEM listed,
ask your Builder for EPI= 88.3
DCA Form 60OA-93
or Form 600E-93
0 10 20 30 40 50 60 70 80 90 100
'-----------------------------------X-----
The maximum allowable EPI is 100. The lower the'EPI the more efficient the home
RESIDENTIAL ENERGY PERFORMANCE RATING SHEET
ITEM HOME VALUE Low Efficiency High Efficiency
SINGL CLR DBL TINT
WINDOWS ....................:Single Clear ;X--------------------
INSULATION ..................
Ceiling R-Value......... 19.0
Wall R-Value......... 5.4
'Floor R-Value......... 0.0
AIR CONDITIONER .............
SEER/EER...................10.0
HEATING SYSTEM ..............
Electric COP/HSPF........ 6.8
Gas AFUE............ 0.00
WATER HEATER ................
Electric EF..............
Gas EF..............
Solar EF..............
OTHER FEATURES ..............
R-10 R-30
---------X-----------
R-0 R-7
--------------- X ----- ;
R-0 R-19
X--------------------�
10.0 SEER 17.0
X--------------------;
9.7 EER 16.0
6.8 HSPF 12.0
1X--------------------
0.78 AFUE 0.90
'------------------- '
0.88 0.96
0.94 ;---------------X-----
0.54 .0.90
0.00 ;------ =--------------
0.40 0.80
---------------------;
I certify that these energy saving features required for the Florida
Energy Code have been installed in this house.
Builder
Address: Signature: Date:
City/Zip
Florida Energy Code for Building Construction'- 1993
Florida Department of Community Affairs FL-EPL CARD93