Loading...
HomeMy WebLinkAboutHVAC LoadsB CLIENT INFORMATION: NAME: MERCEDES HOMES ADDRESS: CI.TY, STATE: FORT PIERCE TOTAL BUILDING LOADS: PROJECT: CLIENT: DATE: DESIGNER: EILEEN ISLE .4 BEDROOM MERCEDES HOMES MAY 15,1997 FRANK DELAPORTE ------------------------------------------------------------------------------ BLDG. LOAD AREA SEN. LAT. + SEN. = TOTAL DESCRIPTIONS QUAN LOSS GAIN GAIN GAIN ------------------------------------------------------------------------------ 1-B WIND. CLEAR GLASS TIM FRAME 179 5,612 0 7,644 7,644 8-B GLS DOOR SGL CLR GLS TIM FR 54 1,693 0 1,501 1,501 13-B PART NOINS 1/2"ASPHALT BD(R-1.3) 401 1,305 0 1;305 1,305 14-B WALL 8" OR 12" BLOCK + R-5 1,706 7,371 0 4,004 4,004 11-C DOOR METAL POLYSTYRENE CORE 36 508 0 399 399 16-D CEILING R-19 INSULATION 2,134 3,392, 0 4,976 4,976 22-A SLAB ON GRADE NO EDGE INSUL 217 5,273 0 0 0 ------------------------------------------------------------------------------ SUBTOTALS FOR STRUCTURE: 4,727 25,154 0 19,829 19,829 PEOPLE 8 0 1,840 2,400 4,240 APPLIANCES 0 0 1,200 0 1,200 DUCTWORK 0 1,718 0 2,470 2,470 INFILTRATION W.CFM: 279.3 S.CFM: 139.7 0 9,217 5,888 2,458 8,346 VENTILATION W.CFM: 0.0 S.CFM: 0.0 0 0 0 0 0 ------------------------------------------------------------------------------ SENSIBLE GAIN TOTAL 27,157 TEMP. SWING MULTIPLIER X 1.10 BUILDING LOAD TOTALS ------------------------------------------------------------------------------ 36,089 8,928 29,873 38,801 SUPPLY CFM AT 20 DEG DT: SQUARE FT. OF ROOM AREA: 1,358 CFM PER SQUARE FOOT: 0.636 2,134 SQUARE FOOT PER TON: 659.983 TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 36.089 MBH TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 3.233 TONS CALCULATIONS ARE BASED ON 7TH EDITION OF ACCA MANUAL J. ALL COMPUTED RESULTS ARE ESTIMATES AS BUILDING USE AND WEATHER MAY VARY. BE SURE TO SELECT A UNIT THAT MEETS BOTH SENSIBLE AND LATENT LOADS. ******** RESInFNTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITF SOFTWARE ******* * EILEEN ISLE l4 BEDROOM MAY 15,1997 PAGE 2 ************************ TOTAL ZONE LOADS FOR ZONE # 1 *********************** -------------------------------------- BLDG. LOAD ------- AREA -------- SEN. -------- LAT. ---------- + SEN. ------- = TOTAL DESCRIPTIONS QUAN LOSS GAIN GAIN GAIN ------------------------------------------------------------------------------ i-B WIND. CLEAR GLASS TIM FRAME 179 5,612 0 7,644 7,644 8-B GLS DOOR SGL CLR GLS TIM FR 54 1,693 0 1,501 1,501 137B PART NOINS 1/2"ASPHALT BD(R-1.3) 401 1,305 0 1,305 1,305 14-B WALL 8" OR 12" BLOCK + R-5 1,706 7,371 0 4,004 4,004 11-C DOOR METAL POLYSTYRENE CORE 36 508 0 399 399 16-D CEILING R-19 INSULATION 2,134 3,392 0 4,976 4,976 22-A SLAB ON GRADE NO EDGE INSUL 217 5,273 0 0 0 ------------------------------------------------------------------------------ SUBTOTALS FOR STRUCTURE: 4,727 25,154 0 19,829 19,829 PEOPLE 8 0 1,840 2,400 4,240 APPLIANCES 0 0 1,200 0 1,200 DUCTWORK 0 1,718 0 2,470 2,470 INFILTRATION W.CFM: 279.3 S.CFM: 139.7 0 9,217 5,888 2,458' 8,346 VENTILATION W.CFM: 0.0 S.CFM: 0.0 0 0 0 0 0 ------------------------------------_------------------------------------------ SENSIBLE GAIN TOTAL 27,157 TEMP. SWING MULTIPLIER X 1.10 BUILDING LOAD TOTALS ------------------------------------------------------------------------------ 36,089 8,928 29,873 38,801 SUPPLY CFM AT 20 DEG DT: 1,358 CFM PER SQUARE FOOT: 0.636 SQUARE FT. OF ROOM AREA: 2,134 SQUARE FOOT PER TON: 659.988 TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 36.089 MBH TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 3.233 TONS CALCULATIONS ARE BASED ON 7TH EDITION OF ACCA MANUAL J. ALL COMPUTED RESULTS ARE ESTIMATES AS BUILDING USE AND WEATHER MAY VARY. BE SURE TO SELECT A UNIT THAT MEETS BOTH SENSIBLE AND LATENT LOADS. ******** RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE Sn7TWARE ******* EILEEN ISLEt BEDROOM MAY 15,1997 PAGE 3 ********************** TOTAL BUILDING LOADS PIE CHARTS *********************** Total Building Loss = 36089 BTUH Yn 11 Z1.04•r.I-4A Door 1.41i Glass 20.24i Roof 9.10�i Infiltration 25.54U Floor 14.61i Ductwork 4.76v Total Building Gain = 38797 BTUH Wall 15.95i Door 1.13*/ Roof 14.11i Glass 25.93i. People 11.55i � � Infiltration Z2.11•r. Appliances 3.04i Ductwork 7.00'i \ ******** RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* * EILEEN ISLELJ BEDROOM MAY 15,1997 PAGE 4 ************************* MISCELLANEOUS PROJECT DATA ************************* DESIGN CONDITIONS: OUTDOOR DRY BULB TEMPERATURE INDOOR DRY BULB TEMPERATURE - ZONE 1 DESIGN TEMPERATURE DIFFERENCE - ZONE 1 INDOOR -OUTDOOR GRAINS DIFFERENCE OUTDOOR DAILY TEMPERATURE RANGE GENERAL PROJECT DATA: PROJECT DATA FILE NAME: TOTAL GROSS WALL AREA (SF): NON -GLASS DOOR AREA (SF): TOTAL NET GLASS AREA (SF): TOTAL SKYLIGHT AREA (SF): TOTAL NET WALL AREA (SF): TOTAL NET ROOF AREA (SF): TOTAL EXPOSED AREA (SF): PEOPLE LATENT LOAD MULTIPLIER: PEOPLE SENSIBLE LOAD MULTIPLIER: LATITUDE DEGREES: TEMPERATURE SWING MULTIPLIER: EXTERNAL SHADING TYPES: NO. OVERHANG OFFSET 1. 1.0 1.0 2. 8.0 1.0 3. 12.0 1.0 4. 0.0 0.0 5. 0.0 0.0 6. 0.0 0.0 7. 0.0 0.0 OUTSIDE AIR DATA: INFILTRATION AIR CHANGES PER HOUR: CUBIC FEET OF CONDITIONED SPACE: TOTAL BUILDING INFILTRATION CFM: TOTAL BUILDING VENTILATION CFM: INFIL. & VENT. SEN. GAIN MULTIPLIER: INFIL. & VENT. LAT. GAIN MULTIPLIER: INFIL. & VENT. SEN. LOSS MULTIPLIER: WINTER SUMMER 42 DEG.F 90 DEG.F 72 DEG.F 74 DEG.F 30 DEG.F 16 DEG.F 62 GRAINS LOW C:\RHVAC\MERCEDES 2,376.00 36.00 23.3.00 0.00 2,107.00 2,134.00 4,510.00 230.00 300.00 27.00 1.10 WINTER SUMMER 0.800 0.400 X 20,949 X 20,949 16,759 8,380 X 0.0167 X 0.0167 279.3 139.7 0.0 0.0 17.60 = (1.10 X 16 SUMMER TEMP. DIFF.) 42.16 = (0.68 X 62 GRAINS DIFFERENCE) 33.00 = (1.10 X 30 WINTER TEMP. DIFF.) ******** RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* * EILEEN ISLE IJ BEDROOM MAY 15,1997 PAGE 5 **************************** DETAILED ROOM LOADS ***************************** ITEM AREA -U- HTG SEN. CLG LAT. SEN. DESCRIPTION QUAN VAL. HTM LOSS HTM GAIN GAIN --------------------------- ------ ------ ------------ ----- ------------- 1'. WALK IN CLOSET MST S -WALL-14B 8 X 11 W -WALL-14B 8 X 8 CEIL-16D DARK 11 X 8 FLOOR-22A 20 FT INFIL. W: 0.0 S: 0.0 DUCTWORK SENSIBLE LOAD SUBTOTAL: TEMPERATURE SWING MULTIPLIER: ROOM TOTALS 2. MASTER BATH ROOM W -WALL-14B 8 X 16 N -PART-13B 8 X 12 W-GLAS-lB 1-P 0-1 S-1 OAS CEIL-16D DARK 16 X 12 FLOOR-22A 16 FT INFIL. W: 16.6 S: 8.3 DUCTWORK SENSIBLE LOAD SUBTOTAL: TEMPERATURE SWING MULTIPLIER: ROOM TOTALS 8.0 WID X 88 0.144 64 0.144 88 0.053 20 0.810 0 11.0 LEN = 88 SF CEIL.HT = 8.0 4.3 380 2.3 0 207 4.3 276 2.3 0 150 1.6 140 2.3 0 205 24.3 486 0.0 0 0 34.3 0 9.1 0 0 0.050 64 0.100 0- 56 618 X 1.100 1,346 0 680 12.0 WID X 16.0 LEN = 192 SF CEIL.HT = 8.0 112 0.144 4.3 484 2.3 0 263 96 0.217 3.3 312 3.3 0 312 16 1.045 31.4 502 85.8 0 1,373 192 0.053 1.6 305 2.3 0 448 16 0.810 24.3 389 0.0 0 0 16 34.3 548 9.1 350 146 0.050 127 0.100 0 -254 2,796 X 1.100 2,667 350 3,076 ******** RESTDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* * EILEEN ISLE BEDROOM MAY 15,1997 PAGE 6 **************************** DETAILED ROOM LOADS ***************************** ITEM AREA -U- HTG SEN. CLG LAT. SEN. DESCRIPTION QUAN VAL. HTM LOSS HTM GAIN GAIN ---------------,----------- ------ ------ ------------ ----- ------------- 3.' UTILITY ROOMOM W -PART-13B 8 X 8.3 N 2PART-13B 8 X 6.6 CEIL-16D DARK 8.3 X 6.6 FLOOR-22A 8.3 FT INFIL. W: 0.0 S: 0.0 DUCTWORK SENSIBLE LOAD SUBTOTAL: TEMPERATURE SWING MULTIPLIER: ROOM TOTALS 4. MASTER BEDROOM&HALL S -WALL-14B 10 X 16 S-GLAS-lB 1-P 0-1 S-1 10M CEIL-16D DARK 16 X 19 FLOOR-22A 16 FT INFIL. W: 26.0 S: 13.0 DUICT-WORK PEOPLE SENSIBLE LOAD SUBTOTAL: TEMPERATURE SWING MULTIPLIER: ROOM TOTALS 5. NOOK S -WALL-14B 10 X 10 E -WALL-14B 10 X 7 S-GLAS-lB 1-P 0-2 S-1 100%S E-GLAS-lB 1-P 0-2 S-1 100$S CEIL-16D DARK 10 X 7 FLOOR-22A 10.5 FT INFIL. W: 20.8 S: 10.4 DUCTWORK SENSIBLE LOAD SUBTOTAL: TEMPERATURE SWING MULTIPLIER: ROOM TOTALS 6.6 WID X 8.3 LEN = 55 SF CEIL.HT = 8.0 66 0.217 3.3 215 3.3 0 215 53 0.217 3.3 173 3.3 0 173 55 0.053 1.6 87 2.3 0 128 8 0.810 24.3 194 0.0 0 0 0 34.3 0 9.1 0 0 0.050 33 0.100 0 52 19.0 WID X 16.0 LEN = 135 0.144 4.3 25 1.045 31.4 304 0.053 1.6 16 0.810 24.3 25 34.3 0.050 2 702 568 X 1.100 0 625 304 SF CEIL.HT 583 2.3 0 784 27.8 0 483 2.3 0 389 0.0 0 857 9.1 547 155 0.100 0 230 300 460 3,251 1,007 317 695 709 0 228 255 600 2,804 X 1.100 3,084 7.0 WID X 10.0 LEN = 70 SF CEIL.HT = 10.0 85 0.144 4.3 367 2.3 0 200 65 0.144 4.3 281 2.3 0 153 15 1.045 31.4 470 27.8 0 417 5 1.045 31.4 157 27.8 0 139 70 0.053 1.6 111' 2.3 0 163 11 0.810 24.3 267 0.0 0 0 20 34.3 685 9.1 438 183 0.050 117 0.100 0 126 1,381 X 1.100 2,455 438 1,519 < s ******** RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* * EILEEN ISLE q BEDROOM MAY 15,1997 PAGE, 7 **************************** DETAILED ROOM LOADS ***************************** ITEM AREA -U- HTG SEN. CLG LAT. SEN. DESCRIPTION --------------------------- QUAN ------ VAL. ------ HTM ----- LOSS ------- HTM ----- GAIN ------ GAIN ------- 6'. KIT FAM LIV FOYER DN 28.0 WID X 28.0 LEN = 784 SF CEIL.HT = 12.0 W -PART-13B 12 X 15.5 186 0.217 3.3 605 3.3 0 605 N -WALL-14B 12 X 28 246 0.144 4.3 1,063 2.3 0 577 S -WALL-14B 12 X 17 150 0.144 4.3 648 2.3 0 352 N -DOOR-11C 6.8 X 3 20 0.470 14.1 282 11.1 0 222 N-GLAS-lB 1-P 0-1 S-1 OAS 60 1.045 31.4 1,881. 27.8 0 1,668 N-GLAS-lB 1-P 0-1 S-1 OWS 10 1.045 31.4 314 27.8 0 278 S-G.DR-8B 1-P 0-3 S-1 100WS 54 1.045 31.4 1,693 27.8 0 1,501 CEIL-16D DARK 28 X 28 784 0.053 1.6 1,247 2.3 0 1,828 FLOOR-22A 37 FT 37 0.810 24.3 899 0.0 0 0 INFIL. W: 149.5 S: 74.8 144 34.3 4,934 9.1 3,152 1,316 DUCTWORK 0.050 678 0.100 0 835 APPLIANCES 1,200 0 SENSIBLE LOAD SUBTOTAL: 9,182 TEMPERATURE SWING MULTIPLIER: X 1.100 ROOM TOTALS 14,244 4,352 10,100 7. BEDROOMS 3 & 4 BATH 11.6 WID X 33.0 LEN = 383 SF CEIL.HT = 8.0 E -WALL-14B 8 X 33 249 0.144 4.3 1,076 2.3 0 584 N -WALL-14B 8 X 11.6 75 0.144 4.3 324 2.3 0 176 S -WALL-14B 8 X 11.6 93 0.144 4.3 402 2.3 0 218 E-GLAS-lB 1-P 0-1 S-1 0%S 15 1.045 31.4 470 85.8 0 1,287 N-GLAS-lB 1-P 0-1 S-1 OWS 18 1.045 31.4 564 27.8 0 500 CEIL-16D DARK 33 X 11.6 383 0.053 1.6 609 2.3 0 893 FLOOR-22A 56 FT 56 0.810 24.3 1,361 0.0 0 0 INFIL. W: 34.3 S: 17.2 33 34.3 1,131 9.1 722 302 DUCTWORK 0.050 297 0.100 0 516 PEOPLE 4 230 300 920 1,200 SENSIBLE LOAD SUBTOTAL: 5,676 TEMPERATURE SWING MULTIPLIER: X 1.100 ROOM TOTALS 6,234 1,642 6,244 RFETDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* * * EILEEN ISLE q BEDROOM MAY 15,1997 PAGE 8 **************************** DETAILED ROOM LOADS ****************************+ ITEM AREA -U- HTG SEN. CLG LAT. SEN. DESCRIPTION QUAN VAL. HTM LOSS HTM GAIN GAIN ---------------I------------ ------ ------ ----- ------- ----- ------ ------- 8. BEDROOM # 4 14.8 WID X 17.4 LEN = 258 SF CEIL.HT = 8.0 E 7WALL-14B 8 X 17.4 124 0.144 4.3 536 2.3 0 291 S -WALL-14B 8 X 14.8 118 0.144 4.3 510 2.3 0 277 W -WALL-14B 8 X 14.8 102 0.144 4.3 441 2.3 0 239 W. -DOOR-11C 6.7 X 2.4 16 0.470 14.1 226 11.1 0 177 E-GLAS-lB 1-P 0-1 S-1 OAS 15 1.045 31.4 470 85.8 0 1,287 CEIL-16D DARK 17.4 X 14.8 258 0.053 1.6 410 2.3 0 602 FLOOR-22A 53.2 FT 53 0.810 24.3 1,288 0.0 0 0 INFIL. W: 32.2 S: 16.1 31 34.3 1,062 9.1 679 283 DUCTWORK 0.050 247 0.100 0 376 PEOPLE 2 230 300 460 600 SENSIBLE LOAD SUBTOTAL: 4,132 TEMPERATURE SWING MULTIPLIER: X 1.100 ROOM TOTALS 5,190 1,139 4,545 ******** PPRIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* * * EILEEN ISLE I BEDROOM MAY 15,1997 PAGE 10 ************************* ZONE # 1 ROOM LOAD SUMMARY ************************* ------------------------------------------------------------------------------ RM ROOM AREA . ------ HEATING ------ ------ COOLING ------ NO. DESCRIPTION- (SF) BTUH % TOT CFM BTUH % TOT CFM ------------------------------------------------------------------------------ 1. WALK IN CLOSET MST 88 1,346 3.7 17 680 2.3 31 2. MASTER BATH ROOM 192 2,667 7.4 35 3,076 10.3 140 3, UTILITY ROOMOM 55 702 1.9 9 625 2.1 28 4. MASTER BEDROOM&HALL 304 3,251 9.0 42 3,084 10.3 140 5. NOOK 70 2,455 6.8 32 1,519 5.1 69 6. KIT FAM LIV FOYER DN 784 14,244 39.5 185 10,100 33.8 459 7. BEDROOMS 3 & 4 BATH 383 6,234 17.3 81 6,244 20.9 284 8. BEDROOM # 4 258 5,190 14.4 67 4,545 15.2 207 ------------------------------------------------------------------------------ ZONE SUBTOTAL 2,133 36,089 100.0 469 29,873 100.0 1,358 LATENT GAIN 8,928 ZONE ------------------------------- TOTALS - 36,089 ---------------------------------------------- 38,801 3.233 TONS EQUIPMENT DATA BRAND: MODEL: TYPE-: DESCRIPTION: EFFICIENCY: CAPACITY: BLOWER CFM: COMMENT: HEATING SYSTEM DESCRIPTION CARRIER FB4ANF042 HEAT PUMP AIR HANDLER 10.0 42 1370 TO 1710 COOLING SYSTEM DESCRIPTION CARRIER 38YCB042 HEAT PUMP CONDENSING UNIT 10.0 40.5 EILEEN ISLE 4 BEDROOM General lighting 3 watts X 2,092sq.ft.= 6,276 Two small appliance circuits @ 1,500 3,000 One laundry circuit @ 1,500 1,500 TOTAL GENERAL LIGHTING 10,776 First 3,000 @ 100%. 3,000 10,776-3,000= 7,776 @ 35% 2,721 NET GENERAL LIGHTING 5,721 Range 8,000 Dryer 5,000 Water heater 4,500 Disposal 1,200 Dishwasher 1,200 Heater 5,000 Air conditioner 0 TOTAL 30,621 30,621 watts / 240 , volts = 127 Amps 0