Loading...
HomeMy WebLinkAboutForm Board SurveyPHOTOCOPYING PROHIBITED @ 2020 GRAPHIC SCALE / 17..5/8"I.R. 20 0 15 30 LB.4942 `UNITED STATES SURVEY FEET I inch = 30 ft. ramig NO WELL, POND, OR LO D.F. WITH IN 100' OF PROPERTY LINE co O 0 NO WELL, POND OR D.F. (n WITHIN 100' FROM PROPERTY LINE FOUND 5/8" I.R. NO CAP 3S � '�- FOUND 5/8" LR. NO CAP 3g 6 NORTH LINE OF THE SOUTH 11.75 ACRES OF THE NORTH 24.75 ACRES OF FRACTIONAL SECTION 7/36/41 NO POND OR D.F. WITHIN 100' FROM PROPERTY LINE (OCCUPIED) N 89047'14" W 833.821 334 16 3 34 0 — - r SHED r0�?! 510.72' FOR'�s - z5.z5' w FORMS AI J a 13.3 547.42' o 19 W 2e y O 0 r 6e ?>q F.5/8"I. R. LB 4942 G N EXISTING 1 y WELL O "fGG 7 .4 I FOUND 5/8" ® 64 DRIVE \ BM IS SET P.K. 93• PAVER X = 18.27 (NAVD88) - SHED CONC. DRIVE EXISTING DRIVE Ci WELL A �ROPANE \ O NCO TANK \ (P EXISTING UNO �, I���E WATER LI� PAVER I \ PROP. DRIVE .CARPORT ?y `�`.\�N \ o w , PAVER I ' ' o WALK Wo J �cOta� v 3"' ONE STORY o � � � CP y CONC` C.B.S. DWELLING36.0 � G _ 160 EXISTING L Cn CONC. D.F. o AREA 006,O PROP. \ / COv. 6p G SET PATIO PAVER P.K. DRIVE \ w 7s — — — - 310 47'14" W 879.43' FOUND 5/8" I.R. K \ (OCCUPIED) NO WELL, POND, OR D.F. WITHIN 100' OF PROPERTY LINE AS BUILT SURVEY PHOTOCOPYING PROHIBITED©2020 FOR REFERENCE ONLY NOT A VALID SURVEY UNLESS SEALED WITH MY EMBOSSED SEAL AND SIGNED BY ME. NOTES: 1,PROPERTY FALLS IN A FEMA FLOOD ZONE X PER FEMA FLOOD MAP 12111CO281K EFFECTIVE 02/19/2020. 2. WRITTEN DIMENSION TAKE PRECEDENT OVER SCALED DIMENSIONS. DISTANCES ARE NOT TO BE SCALED FOR CONSTRUCTION AND/OR DESIGN PURPOSES. THE SOUTH 150 FEET OF THE SOUTH 300 FEET OF THE SOUTH 11.75 ACRES OF THE NORTH 24.75 ACRES OF 3. FIELD MEASUREMENTS, PLAT MEASUREMENTS AND DEED MEASUREMENTS ARE CONCURRENT UNLESS OTHERWISE SPECIFICALLY FRACTIONAL SECTION 7, TOWNSHIP 36 SOUTH, RANGE 41 EAST, ST. LUCIE COUNTY, FLORIDA. EXCEPTING, STATED ON THIS SURVEY. HOWEVER, FROM THE ABOVE DESCRIPTION ALL RIGHTS OF WAY OF THE FLORIDA EAST COAST RAILWAY AND 4. NO UNDERGROUND INSTALLATIONS OR IMPROVEMENTS HAVE BEEN LOCATED AS PART OF THIS SURVEY, UNLESS SHOWN OR MADE PUBLIC ROADS NOTE OF HEREON. TRACT CONTAINS 128615.21 SQUARE FEET. 5. NO INSTRUMENTS OF RECORD REFLECTING EASEMENTS, RIGHTS -OF -WAY AND/OR OWNERSHIP HAVE BEEN FURNISHED THIS SURVEYOR, EXCEPT AS SHOWN. 6. ENCROACHMENTS, IF ANY ARE SHOWN HEREON. 7, BEARING SHOWN HEREON REFER TO THE RECORDED PLAT AS STATED IN DESCRIPTION ABOVE. 8, ELEVATIONS, IF ANY, SHOWN HEREON REFER TO NORTH AMERICAN VERTICAL DATUM (1988) WHERE MEAN HIGH SEA LEVEL IS 0-00, UNLESS OTHERWISE NOTED. 9. THIS SURVEY IS NOT TRANSFERABLE BY OWNERS AFFIDAVIT OF SURVEY OR SIMILAR INSTRUMENT. 10. THIS SURVEY IS VALID IN ACCORDANCE WITH F.S. 627.7842, FOR A PERIOD OF 90 DAYS FROM THE DATE OF CERTIFICATION. 11. THIS SURVEY MEETS PRECISION REQUIREMENTS FOR RURAL SURVEYS. RELATIVE PRECISION IS GREATER THAN 1 FOOT IN 5000 FEET. (� 12. ADDITIONS OR DELETIONS TO THIS SURVEY MAP AND/OR REPORT BY OTHER THAN THE SIGNING PARTY OR PARTIES IS PROHIBITED KBER1_ 1I51 �,M, NDE VRE SICNRIDRE I ` WITHOUT WRITTEN CONSENT OF THE SIGNING PARTY OR PARTIES. MV ORIGINAL BRIBED SEA NO CAP SOUTH LINE OF THE SOUTH 11.75 ACRES OF THE NORTH 24.75 ACRES x \ OF FRACTIONAL SECTION 7/36/41 0 \ A/C =AIR CONDITIONING PAD =CENTRAL ANGLE/DELTA =SOIL TEST SITE O� = BENCHMARK SYMBOL ASPH =ASPHALT BM =BENCHMARK R = CABLE TELEVISION BOX (C) = CALCULATED C.B.S. = CONCRETE BLOCK STRUCTURE C.L.F. =CHAIN LINK FENCE C.M.P. = CORRUGATED METAL PIPE C/L =CENTERLINE CONC. =CONCRETE COV, =COVERED (D) = DESCRIPTION D.B. = DEED BOOK D.E. = DRAINAGE EASEMENT D.U.E = DRAINAGE AND UTILITY EASEMENT D.F. = DRAIN FIELD ENC. =ENCROACHMENT ENCL. =ENCLOSURE ESM'T. = EASEMENT EXIST. = EXISTING X = ELEVATION ® = ELECTRICAL PANEL LEGEND: \poo = EXISTING ELEVATION = PROPOSED ELEVATION o = FIRE HYDRANT C.M. = CONCRETE MONUMENT F = FOUND FF = FINISH FLOOR I.R =IRON ROD N & TT = NAIL & TIN TAG P.K. = P,K. NAIL I.P. = IRON PIPE H.W.F. = HOG WIRE / FIELD FENCING G = LIGHT POLE LB = LISCENSE BUREAU (M) = FIELD MEASUREMENT M.H. =MANHOLE MAX. = MAXIMUM MONT =MONUMENT MIN. = MINIMUM N&D = NAIL AND DISK O.D. = OUTSIDE DIAMETER O, R.B. = OFFICIAL RECORD BOOK O/H = OVERHEAD UTILITY LINE P.C.P. = PERMANENT CONTROL POINT (P) = PLAT DIMENSION RECEIVED 3 OCT 12 zozo �-o G Permitting WPSrtment St. Lucie county FOR REFERENCE ONLY NOTA VALID SURVEY UNLESS SEALED WITH MY EMBOSSED SEAL AND SIGNED BY ME, I P P. P.O.C. PC P.R.M. PG. PLTR. POR. PROP. =PLAT BOOK = POINT OF BEGINNING = POINT OF COMMENCEMENT = POINT OF CURVATURE = PERMANANT REFERENCE MONUMENT = PAGE = PLANTER =PORCH =PROPOSED TRIANGLE 4750 Royal Palm BeacO.B. D Beach Boulevard W. Palm Beach, FL 33412 Land Surveying Inc. 561.798-3966 (phone) SUfVe In t0 Specification Surveying P 561.791-8777 (fax) LB # 2992 triangle2992@gmail.com — — -- — R = RADIUS CERTIFIED TO: R.C.P. = REINFORCED CONCRETE PIPE GINGER KING RNV = RIGHT OF WAY 5/8" I.R. = 5/8" IRON ROD AND CAP #2992 JOHN T. LANZA S.F. = SQUARE FEET DERRICK GALE CONSTRUCTION P.K. = PARKER-KALON NAIL AND DISK S = SET MONUMENT S.T. =SEPTIC TANK SCRN. =SCREENED 0 =TELEPHONE RISER BOX =TYPICAL �� re" SCALE: ADDRESS: 'TVP. U.E. = UTILITY EASEMENT , 2020 1 "= 30'coy SOUTH INDIAN RIVER DR. = UTILITY POLE (POWER OR TELEPHONE) =WASHER _'7273 E CRG 031920W DRAWN BY: FORT PIERCE, FL. 34982 W.C. = WITNESS CORNER SITE070620DJH U�,��C3LL)' RMS100720DJH C CW.F. = WOOD FENCE= WATER METER NO.: F.B. PG.260 CRG-RDW