Loading...
HomeMy WebLinkAboutApproved Site Planm 0 C6 TYP. .. ---.--------_-ICI--.-_-_-_-._-_-- - BMS BM3 _I COVERED PATIO 20'0" X 10'0" BM5 I m N 5'-0" 91-0" 81,8. 6,-0" 26'-4. 25 SH ® i EGRESS DSL 25 SH DBL 25 SH - 2868 © © © 3X3 (� F.G. O GAR EN TU 4.�� HOSE SHWR (N BIBS 3'-4" in 4 BEDROOM #2 w LIVING ROOM n S- 8' CEILING „ 6) _ VAULT CLG. r 36" FLAT BAR i� TOP ON341%" WALL ATH _ -0" CLG. 12'-4' 2'-4" 3'.4" 4'-10" 2'-6" 16'-10" 3.6" 5'-0" 2,,7" 1,-9" m M 68" SS" - -- 11 ----- -,----- : O = co CN Cl) �f INTERIOR RIDGE LINE N ' ACCESS OBC•2068 _ ;I 22°x36" . " - - REF. I arnc y` - - -- -N KITCHEN 1 4 1'-6" COL. TO BE �; N \ IWIC IC I VAULT CLG.. FRAMED TO CLG. 2668 = I m 8' CLG. I I 8'CLG.cc F8' CL DOOR, PER I RANGE/HOOD m ACCESSIBILIT l I w CODEiff M _ _ w-10" 3,-6', i i 3068 l N 1 7 5'-8" 3'-0" 2',7" 17'-0" 4'-2" 4'-0" 4'-8" 19 BRK-'dim 2" SQ• M -IN -_ 8' CEILING DBL-2068 s6d R/A "'- - -- CLG. LINE COL. IYP. m 4 GRILL OF2.: i -=-------------s2NV S01171 WNE S BEDRO M8,-4. 8'-0" CLG.PROVIDE 4'-5" ®t0a1 PLATFORM _ ' FOR HVAC UNIT ,.N 0� vERIFYSIZEwITH DINING ROOM STUDY 05 ( MFGR 2'-8"WCEILING , , I I 8'CEILING m' i I I BEDROOM #3 i�VERIFY Iz I 12868 Elv CLG. - �I x 14 "4 LOCATION u0 W/ BUILD R THRU ROOF D N DRYER VENTJ(W) 12`0" 16' 4" 11' 6°L 9' 4" 12'-10„ HANSON BOXW 0 36"AFF FL EGRESS ( ' BW2 C2 wH MS03 2 BOW TOP LI 35 SH - ♦ 1 � DBL 25 SH S1 O. 20,-0" 6'-2" 6-011 , 7,-6„ , ♦ 11'-8" 3'-8" __ NOTE: BUILDER TO PROVIDE ; PULL ON. STAIRS �ENTRY „ _ � . - ' • . CRUCIAL D/M£NS/ `n 'coo APPLIANCE PROTECTION IF - 221/2"x 54"MINA ISEESHE-14FORDETAILS `- ♦ i fRAM£R START L4 YOUr REQUIRED BY MUNICIPALITY. , , ♦ HERE! •------------• HANDRAIL O HANDRAIL - M -- ---_-- CD11.ONLY ALT. BASE CONNECTION TO HTT4 (1) SIMPSON DSP EA. SIDE a ENTRY rj=C5 C5 CS CD1 S-3 S3 2'b" , 2 5" 4'-10" 2 GARAGE 6" " & CEILING 22'-7" 12%5" SLAB DIM. ___ --------- ____________ G.T. ELEVATION_ "A" _ _ _ _ _ _ _ _ _ _ -419 ti I , HOS S,2 BIBB ; O 16 X 7 OVERHEAD DOOR FLOOR PLAN "All - SCALE: 1/4" = 1'-0" C 160 MPH OPENING PRESSURES ENCLOSED -EXPOSURE B A +27.6 /-29.9 O +27.6 /-37.0 O+26.5 / -28.8 O +26.5 / -34.4 O+24.8 / -27.1 ) +24.8 / -31.1 O+24.3 /.-27.5 O +23.3 / -26.0 NOTE: 1. WIND SPEED LISTED ABOVE IS AN "ULTIMATE" WIND SPEED. THE WIND PRESSURES LISTED ABOVE ARE 'ALLOWABLE" PRESSURES WALL LEGEND FRAMED WALL g m �7 MUM ' BEARING FRAME WALL Y ALL 2X EXTERIOR WALLS W/EXTERIOR SHEATHING o ATTACHED PER NAILING SCHEDULE ACT AS SHEARWALLS. SEE PLAN AND WALL SECTIONS FOR € STUD SPACING AND GRADE. MASONRY WALL $ N 5t "*§!B fittB O GENERAL NOTES E ti a 1. R302.5.1 Door from garage Into house must be a r `' ft7864 SP a N minimum 1 3/8" solid wood door, solid or o o 7 64 honeycomb steel door, or 20 Minute fire rated door. 'h 2. Bathroom exhaust fans must vent to the exterior of r rr ; m the building, exhaust to attic space and soffits is not r .f 4U =b acceptable. Ventilation shall be permitted to exit through E •:vim° the soffit If solid soffit is Installed W-0" on each side of IS the venting- w aR°a o s ; >,J A 3. R302.6 The garage shall be separated from the'�a,+=: residence and it's attic by not less then 1/24neh (12.7mm) gypsum board applied to the garage side. Garage beneath rooms shall be separated from all habitable rooms above by not less than 5/8 inch -9 (15.9mm) type X gypsum board or equivalent. Where c the separation is a floor -ceiling assembly, the _ structure supporting the separation shall also E protected by not less than 1/2 inch (12.7mm) g N N. N gypsum board or equivalent.s w W go IMF Iu a �8 1,*Q1 W 4. R312.2.1 Window sills In dwelling units, where the opening of an operable window Is located more than 72 Inches (1829 mm) above the finished grade or 01 " surface below, the lowest part of the clear opening g c 0 a of the window shall be a minimum of 24Inches `� s 4 � ,- wui vi (610 mm) above the finished floor of the room In a pbw s a m 8 ® ®o: which the window is located. Glazing between the „ 5 = 2 a a z floor and 24 inches (610 mm) shall be fixed or have uv, 8 "-e s o ¢ r openings through which a 44nch-diameter (102 mm) w RE- n � s, W � E � & m m sphere cannot pass; a'§.it. m-.. g S n r 5. R308.4.2 All windows within 2'-0" of doors and in �s `A shower or tub areas will be safety tempered glass. o " a l is > - W a' -_+ F� N µ FDSfN6.COM ❑ ❑ ❑ 6. Calling for exterior entries and covered porches to have 7/16". span rated OSB nailed. per zone on 8 VI mg '^ roof diagram nailing schedule or 5/8" COX. 10 t+. ]X T&G acceptable for substitution. Z g We 7.. EC: R4022.4 Access doors from conditioned spaces to Q a unconditioned spaces (e.g., attics and crawl spaces) shall be weatherstripped and insulated to a level ; o_ equivalent to the insulation on the surrounding surfaces. �, z ' tIl 0 Q 8. Laundry Note: (Unless noted otherwise) Provide dryer / j - vent thru roof max. Igt. 35'-0", washer & dryer units (washer unit to be always on left side when facing E f units) hanson box 0 36" off E 9. Cellings for exterior entries and covered porches to be 7/16" OSB on underside of roof trusses Shall be attached to all framing members with 2x blocking a �-�w�� V W F l o provided at perimeter. The OSS shall be attached w/ Sd w o p I nails at 6" O.C. field and 4" O.C. at edges or 7d screw c shank 3". O.C. field and 4" edges. Vinyl ceiling to be attaches to OSB per manufacturer specifications x sir' :,T• = U r y d L. 0 0 � w U O 7 � 0 Co !n 0 a)Oj N 0 � of$ 0 (A E O O_ I cS_CL< ` _ > Q rd QLU 'a) V� L �i w CL ai m p U)co ; 0�� SEE SHEET 3.1 FOR DETAILS AND SCHEDULES AREA CALCULATIONS 1st FLOOR 2010 S.F. TOTAL LIVING (AC) 2010 S.F. GARAGE 425 S.F. COVERED ENTRY "A" 135 S.F. COVERED PATIO/LANAI 200 S.F. TOTAL AREA UNDER ROOF 2770 S.F. m ono., A DADS HOMES . FLORIDA CONTRACTORS LICENSE NO. CRC133014C 3000 GULFBREEZE PARKWAY GULFBREEZE, FLORIDA 32563 DIVISION LOCATION: r z PORT ST. LUCIE v ♦ Job Information: L m Y < T N W d m � '4 � N s C m N Uj a o 0) E s co LO Z •• m m m m b_ 0 _5 LLI n N o JmU)V) Model Name / Number: a 2010 YJ Plan Issue Date: a" Monday, January 20,2020VI ' a KA PROJECT NUMBER: v 20-0025 Sheet: Of: Lm q FLOOR PLAN