Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ttu Project Name: Lot 45 Block 1 Wa�erstone 2000 AGL Builder Name: ADAMS HOME Street: 5431 Lugo Street Permit Office: L P ®!� City, State, Zip: Fort Pierce , FL , 34951 Permit Number:Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Floriddeo29ty, Permitting 1. New construction or existing New (From Plans) 9. Wall Types (1940.4 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int.lnsul, Exterior R=4.1 1428.20 ft2 b. Frame - Wood, Adjacent R=13.0 288.56 ft2 3. Number of units, if multiple family 1 c. Frame - Wood, Exterior R=13.0 223.66 ft2 4. Number of Bedrooms 4 d. N/A R= ft2 10: Ceiling Types (2004.0 sqft.) Insulation Area 5: Is this a worst case? No a. Under Attic (Vented) R=30.0 2004.00 ft2 6. Conditioned floor area above grade (ft2) 2004 b. N/A R= ft2 c. R= ft2 Conditioned floor area below grade (ft2) 0 11. Ducts R ft2 7. Windows(216.0 sqft.). Description Area a. Sup: Attic, Ret: Main, AH: Main 6 400.8 a. U-Factor: Dbl, U=0.33 136.36 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 38.54 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:16.00 c. U-Factor: Dbl, U=0.33 23.33 ft2 SHGC: SHGC=0.31 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 17.78 ft2 a. Electric Heat Pump 34.6 HSPF:8.50 SHGC: other (see details) Area Weighted Average Overhang Depth: 1.850 ft. Area Weighted Average SHGC: 0.274 14. Hot water systems a. Electric Cap: 40 gallonsEF: 8. Floor Types (2004.0 sqft.) Insulation Area 0.940 a. Slab -On -Grade Edge Insulation R=0.0 2004.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.108 Total Proposed Modified Loads: 61.89 PASS Total Baseline Loads: 66.02 I hereby certify that the plans fications covered Re�w of the plans and 1 Sr this calculation are in corn a ith the Flori rgy specifications covered by this Code. calculation indicates compliance`+ with the Florida Energy Code. .PREPARED BY: DATE: 07-3n-202n Winn I<eomany Before construction is completed this building will be inspected for compliance with Section 553.908 t� ""~�. t a I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida r y C d►'pt� OWNER/AGEN ` BUILDING OFFICIAL: DATE: DATE: - Compliance requires certificationby the air handler unit manufacturer that the air handler enclosure:qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 7/30/2020 11:16 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 - k'A FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 45 Block 1 Waterstone 20 Bedrooms: 4 User Conditioned Area: 2004 Total Stories: 1 1 Worst Case: No ADAJS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Single-family New (From Plans) Address Type: Street Address Lot # 45 Block/Subdivision: Waterstone I PlatBook: Street: 5431 Lugo Street County: St. Lucie City, State, Zip: Fort Pierce , FL, 34951 CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 2004 18837.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2004 18837.6 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 181.9 ft 0 2004 ft2 ---- 0.35 0 0.65 ROOF / V # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2241 ft2 502 ft2 Medium N 0.85 N 0.85 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2004 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 2004 ft2 0.11 Wood 7/30/2020 11:16 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS nrnt Adjacent Space Cavity Width To Wall Type1 Et In Et Height In Area Sheathing Framing Solar BelowR-\/:;Ille RA/alife Fraction Ahqnr (' W Exterior Concrete Block - Int Insul Main 4.1 53 7 9 7 513.5 ft2 0 0 0.6 0 _ 2 I S Exterior Concrete Block - Int Insul Main 4.1 20 9 9 4 186.7 ft2 0 0 0.6 0 3 E Exterior Frame - Wood Main 13 25 1 8 11 223.7 ft2 0 0.23 0.6 0 4 E Exterior Concrete Block - Int Insul Main 4.1 39 0 9 4 364.0 ft2 0 0 0.6 0 5 N Exterior Concrete Block - Int Insul Main 4.1 37 4 9 9 364.0 ft2 0 0.6 0 6 - Garage Frame - Wood Main 13 30 11 9 4 288.6 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 - Wood Main None .25 2 8 6 8 17.8 ft2 2 S Insulated Main None .25 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang v # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W 1 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft2 1 ft 5 in 0 ft 9 in None None 2 W 1 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 5 in 0 ft 9 in None None 3 S 2 Vinyl Low-E Double Yes 0.33 0.31 N 10.0 ft2 6 ft 0 in 3 ft 0 in None None 4 S 2 Vinyl Low-E Double Yes 0.33 0.31 N 6.7 ft2 5 ft 0 in 6 ft 0 in None None 5 S 2 Vinyl Low-E Double Yes 0.33 0.31 N 6.7 ft2 5 ft 0 in 6 ft 0 in None None 6 S 2 Vinyl Low-E Double Yes 0.33 0.21 N 38.5 ft2 1 ft 5 in 4 ft 0 in None None 7 E 3 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 5 in 0 ft 9 in None None 8 N 5 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 1 ft 5 in 0 ft 9 in None None 9 N 5 Vinyl Low-E Double Yes 0.33 0.23 N 80.9 ft2 1 ft 5 in 0 ft 9 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 483 ft2 483 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000418 2197.7 120.65 226.9 .1545 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.6 kBtu/hr 1 sys#1 7/30/2020 11:16 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPf)RT COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 35 kBtu/hr 1167 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ftz DUCTS -- Supply -- V -- Return -- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 400.8 ft Main 100.2 ft Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Feb HeatinHJan HFeb Mar Mar A r f APr I Ma X Jun Jul May Jun jXjJul AuSeP rj Au Se f rl Q Oct Oct [ ] Nov [Nov Dec HDec Ventin Jan Feb X Mar X [X] A r May Jun Jul Aug Se Oct [X] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main 7/30/2020 11:16 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED rNERGY PERFORMANCE INDEX* = 94 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 5. Is this a worst case? (yes/no) 5. No 6. Conditioned floor area (sq. ft.) 6. 2004 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.348 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.274 c) Area 7c. 216.0 8. Skylights a) U-factor: (weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: 13.. Cooling system: Capacity 35.0 a) Split system SEER 16.0 b) Single package SEER c) Ground/water source SEER/COP - d) Room unit/PTAC EER e) Other 14. Heating system: Capacity 34.6 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c, a) Electric resistance EF 0.94 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. 13.0 e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 13.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a). Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder SignaturP�� Date: Address of New Home: 5431 Lugo Street City/FL Zip: Fort Pierce, FL 34951 7/30/2020 11:16:59 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1