Loading...
HomeMy WebLinkAboutFlintlastic Self Adheredk_9 COUNTY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) CertainTeed LLC 18 Moores Road Malvern, PA 19355 SCOPE: MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.eov/economy This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Flintlastic Self -Adhered Roofing Systems Over Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA #15-0622.21 and consists of pages 1 through 18. The submitted documentation was reviewed by Alex Tigera. .i iTZ NOA No.: 20-0131.01 tau►ra annE counrrr Expiration Date: 04/13/25 Approval Date: 03/19/20 Pagel of 18 ROOFING ASSEMBLY APPROVAL Cateaorv• Roofing Sub-Cate¢orv: Modified Bitumen Material: SBS Deck Type: Wood Maximum Design Pressure -127.5 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product Dimensions Spec Description Flintlastic SA NailBase 39 3/8" x 66'6"; Roll ASTM D 4601, Type Fiberglass reinforced, SBS modified weight: 82 lbs. II bitumen base sheet. (2 squares) Flintlastic SA PlyBase 39 3/8" x 66'6"; Roll ASTM D4601, Self -adhering, fiberglass reinforced, SBS weight: 86 lbs. Type ll modified bitumen base/ply sheet. (2 squares) All Weather/Empire Base 39 3/8" x 65' 10' ; ASTM D 4601 Type Asphalt coated, fiberglass reinforced base Sheet Roll weight: 701bs. II sheet. (2 squares) UL Type G2 Yosemite Venting Base 39 3/a" x 32' 10"; Roll ASTM D 3909 Mineral Surfaced fiberglass reinforced Sheet weight: 85 lbs. ASTM D 4897, Type buffer sheet. (1 square) II UL Type G3 Flexiglas Base Sheet 39 3/8" x 98'9'; Roll ASTM D 4601, Type Modified Bitumen coated fiberglass base weight: 90 lbs. II sheet. (3 squares) UL Type G2 Flintlastic Poly SMS Base 39 3/a" x 64' 3"; Roll ASTM D 4601, Modified Bitumen coated polyester base Sheet weight: 901bs. Grade S, Type II sheet. (2 squares) UL Type G2 Glasbase Base Sheet 39 3/8" x 98'9' ; Roll ASTM D 4601 Type Asphalt coated, fiberglass base sheet. weight: 75 lbs. II (3 squares) UL Type G2 Flintlastic Ultra Poly 39 3/8" x 32' 10'; Roll ASTM D 6164, Smooth surfaced SBS Modified Bitumen SMS Base Sheet weight: 90 lbs. Grade S, Type I Membrane with non -woven polyester mat (1 square) reinforcement for mop applications. Flintlastic SA Mid Ply 39 3/g" x 32' 1 "; ASTM D 6163, Self -adhering, polyester reinforced, SBS Roll weight: 62 lbs. Grade S, Type I modified bitumen ply sheet. (1 square) Flintlastic SA Cap FR 39 3/g" x 32' 11' ; Roll ASTM D 6163, Self -adhering, fiberglass reinforced, SBS weight: 88 lbs. Grade G, Type I modified bitumen cap sheet. (I square) Flintlastic SA Cap 39 3/8" x 32'11"; Roll ASTM D 6164, Self -adhering, polyester reinforced, SBS Ix weight: 95 lbs. Grade G, Type I modified bitumen cap sheet. (1 square) NOA No.: 20-0131.01 Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 2 of 18 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product Dimensions Spec F1intPrime Asphalt 1, 3 or 5 gal pail ASTM D 41 F1intPrime SA 1, 3 or 5 gal pail Proprietary APPROVED INSULATIONS: TABLE 2 Product Product Description F1intBoard ISO F1intBoard ISOH ACFoam-II ENRGY 3 H-Shield Polyisocyanurate insulation Polyisocyanurate insulation Polyisocyanurate insulation Polyisocyanurate insulation Polyisocyanurate insulation Multi -Max FA-3 Polyisocyanurate insulation DensDeck Roof Board Gypsum coverboard DensDeck Prime Roof Board Gypsum coverboard SECUROCK Gypsum -Fiber Roof homogenous fiber reinforced Board APPROVED Description Asphalt primer Water -based, polymer modified primer. Manufacturer (with current NOA) CertainTeed LLC CertainTeed LLC Atlas Roofing Corp. Johns Manville Corp. Hunter Panels, a div. of Carlisle Const. Materials Rmax Operating, LLC. Georgia Pacific Gypsum LLC. Georgia Pacific Gypsum LLC. USG Corp. NOA No.: 20-0131.01 Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 3 of 18 APPROVED FASTENERS: Fastener Number 1. 2. 3. 4. 5. 6. 7. 8. 9. 10 11 12 13 14. 15. 16. 17. 18. 19. 20. Product Name Dekfast DF-#14-PH3 Trufast #14 HD Fastener #14 Roogrip OMG Heavy Duty F1intFast # 14 Fastener Dekfast DF-#12-PH3 #12 Standard Roofgrip 3 in. Round Metal Plate Trufast #12 DP Fastener F1intFast #12 Fastener Dekfast PLT-H-2-7/8 Flat Bottom Metal Plate Trufast 3" Metal Insulation Plate F1intFast 3" Metal Insulation Plate ICP Adhesive CR-20 Millennium One Step Foamable Adhesive OMG OlyBond 500 Adhesive OMG OlyBond 500 Green Adhesive Pliodeck Insulation Adhesive Insta Stik Quik Set Insulation Adhesive TABLE 3 Product Description Roofing screw Roofing screw Roofing screw Roofing screw Roofing screw Roofing screw Insulation fastener 3" round galvalume AZ50 steel plate Roofing screw Roofing screw hexagonal steel plate 3" square steel plate 3" round steel plate 3" round steel plate Polyurethane two component low rise insulation adhesive Polyurethane two component high rise insulation adhesive Spray polyurethane foam insulation adhesive Spray polyurethane foam insulation adhesive Polyurethane one component low VOC adhesive system Polyurethane one component moisture curing adhesive Manufacturer (with current NOA) SFS Group USA, Inc. Altenloh, Brinck & Co. U.S., Inc. OMG, Inc. OMG, Inc. CertainTeed LLC. SFS Group USA, Inc. OMG, Inc. OMG, Inc. Altenloh, Brinck & Co. U.S., Inc. CertainTeed LLC. SFS Group USA, Inc. OMG, Inc. Altenloh, Brinck & Co. U.S., Inc. CertainTeed LLC. ICP Adhesives and Sealants, Inc. H.B. Fuller Company OMG, Inc. OMG, Inc. Ashland, Inc. The Dow Chemical Company NOA No.: 20-0131.01 Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 4 of 18 APPROVED SURFACING/COATING OPTIONS: TABLE 4 Chosen components must be applied according to manufacturer's application instructions. Any coating, listed below, used as a surfacing, must be listed within a current NOA. System Manufacturer Application Number 1. Generic Gravel applied at 400 lbs/sq., adhered with flood coat of asphalt at 60 lbs/sq. 2. Generic Slag applied at 3001bs/sq., adhered with flood coat of asphalt at 60 lbs/sq. 3. Karnak Corp. Karnak (#97 AF) Fibrated Aluminum Roof Coating applied at an application rate of 1.5 gal/sq. 4. Gardner Asphalt Corp. APOC #212 Fibered Aluminum Roof Coating applied at an application rate of 1.5 gal/sq. 5. Gardner Asphalt Corp. APOC #400 Sunbrite applied at an application rate of 3 gal./sq. NOA No.: 20-0131.01 QADE4M=NT Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 5 of 18 EVIDENCE SUBMITTED: Test Aeency Test Identifier Description Date Underwriters Laboratories R11656 UL790 Annually Factory Mutual Research 2D5A9.AM FM 4450 06/22/99 3008869 FM 4470 03/19/01 3009610 FM 4450 10/15/01 3012321 FM 4450 07/29/02 3014692 FM 4450 08/05/03 3014751 FM 4450 08/12/03 3025766 FM 4470 11/13/06 3037127 FM 4470 01/11/10 3039046 FM 4470 06/15/10 3048520 FM 4470 09/19/13 Trinity ERD 3518.12.03 TAS II4-F/G/I 12/01/03 3521.07.04 TAS 1144 & TAS 117(13) 07/28/04 3522.07.04 TAS 114-D 07/28/04 C8500SC.11.07-R1 ASTM D 6862/TAS 117(13) 08/07/09 C8370.08.08-RI TAS 114-H/J & TAS 117(13) 10/05/09 C30310.12.09 TAS 114/TAS 117 12/17/09 C30560.06.10 TAS 114/TAS 117 06/10/10 C32830.07.10 FM 4470 / TAS 114 07/20/10 C35500.02.11 TAS 117(13) 02/09/11 3513.08.02-RI TAS 114/TAS 117 03/17/11 C3519.12.03-RI TAS 114-D/J & TAS 117(B) 04/15/11 C35460.05.11 ASTM D1876 06/16/11 03515.07.03-1-R1 TAS l 144 & TAS 117(13) 06/27/12 C42110.08.12 TAS 114 & TAS 117 08/13/12 C44580.07.13 ASTM D 1876, 07/25/13 TAS 114, FM 4474 C45620.03.14 ASTM D1876, TAS 114 (H), 03/27/14 FM 4474 C47350.50.14 FM 4470 05/22/14 NOA No.: 20-0131.01 Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 6 of 18 Membrane Type: SBS MODIFIED, SELF -ADHERING Deck Type 1: Wood, Non -Insulated Deck Description: Min 19/32" thick plywood at max 24" spans attached 6" o.c. using #8 wood screws. System Type E(3): Base sheet mechanically fastened All General and System Limitations apply. Anchor/Base Sheet: One or more layers of Flintlastic SA NailBase, mechanically attached as described below. Fastening: Anchor sheet shall be fastened with FBC HVHZ nails and tin caps spaced 6" o.c. at the 3" lap and 6" o.c. in three, equally spaced center rows. Ply Sheet: One or more layers of Flintlastic SA PlyBase or Flintlastic SA Mid Ply, self -adhered. Membrane: One layer of Flintlastic SA Cap or Flintlastic SA Cap FR, self -adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design Pressure: - 75 psf (See General Limitation #7.) NOA No.: 20-0131.01 Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 13 of 18 Membrane Type: SBS MODIFIED, SELF -ADHERING Deck Type 1: Wood, Non -Insulated Deck Description: Min 19/32" thick plywood at max 24" spans attached 6" o.c. using #8 wood screws. System Type E(4): Base sheet mechanically fastened All General and System Limitations apply. Anchor/Base Sheet: One or more layers of Flintlastic SA NailBase, mechanically attached as described below. Fastening: Anchor sheet shall be fastened with OMG #12 Standard Roofgrip with OMG 3 in. Round Metal Plates spaced 8" o.c. at the 3" lap and 8 o.c. in two, equally spaced center rows. Primer: Apply ASTM D41 primer to stress plates. Ply Sheet: One or more layers of Flintlastic SA P1yBase or Flintlastic SA Mid Ply, self -adhered. (Optional) Membrane: One layer of Flintlastic SA Cap or Flintlastic SA Cap FR, self -adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design Pressure: - 82.5 psf (See General Limitation 47.) NOA No.: 20-0131.01 Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 14 of 18 WOOD DECK SYSTEM LIMITATIONS: 1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 3. 4. VA 8. 0 10. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. Fastener spacing for mechanical attachment of anchoribase sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS I I I and applicable wind load requirements. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and comers). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 20-0131.01 MIAM1 APPRO EDL Expiration Date: 04/13/25 Approval Date: 03/19/20 Page 18 of 18