HomeMy WebLinkAboutBuilding PlanGENERAL NOTES`: CONTRACTORS TO VERIFY ALL SQUARE FOOTAGES REPORT ANY DISCREPANCIES TO DESIGNER BEFORE PROCEEDING W/ WORK TEMPERED CLASS TO BE USED AT ALL HAZARDOUS AREAS (F.B.G. 2011) EXTERIOR DOORS $ WINDOWS SHALL BE CERTIFIED FOR RESISTANCE TO LOCAL WIND PRE55URE AS REQUIRED BY F,B.C.2011 110 MPH WIND LOAD ALL LUMBER IN CONTACT W/ CONCRETE OR MASONRY SHALL BE PRE55URE TREATED ALL STRUCTURAL FRAMING TO BE HEM FIR 02, SPF 01, SOUTHERN PINE 02 OR APPROVED ALTERNATE W/ Fb=1000 PZJ, MIN. - NON - STRUCTURAL FRAMING MAY BE SELECTED SPECIES "STUD" GRADE 'I LEVEL 2 AJ—TERATION 2011 FLORIDA EXI TING BUILDING CODE W/ 5UPPLEMENT5 SECTION 6 0 STRUCTURAL SECTION 6 O i5 ELECTRICAL THE LEVEL OF WORK SHALL INCLUDE THE FOLLOWING FRAME NEW O WALLS W/ STUDS a0 16" O/C U)� �_ " INSTALL NE SHINGLE ROOF t - I �'�k�4 INSTALLING NEW IMPACT DOOR INSTALL NEW ELECTRICAL CIRCUITS INSTALL INSULATION, DRYWALL 4 TRIM INSTALL NEW FLOORING PAINT, T LE S TRIM WORK NAILING SCHEDULE ITEM NAIL SIZE EDGE SPACING FIELD SPACING NOTES 5/8" CDX ROOF SHEATHING B d 6" O.C. 6" O.C. GLUE ALL PLYWOOD WITHIN 4' OF ROOF EDGE 5/8" CDX ROOF SHEATHING 8 d 4" O.C. 6" O.C. 8' - O" FROM GABLE END ROOF EDGE 1/2" CDX WALL SHEATHING 8 d 6" O.C. 6" O.C. 3/4" TtG FLOOR SHEATHING 10 d 6" O.C. 6" O.C. GLUE ALL PLYWOOD (PL400 OR EQUAL) STUD TO 2 X 12 HEADER I6 d 3 PER HEADER PLY BASE SHEET NAILING 6" O/C B" t 111' ROOF SHEATHING USE 8d RING SHANK NAILS ALL SCREWS 4 NAILS SHALL BE GALV. UJIND LOAD INFc'.), R M AT10N CODE EDITIONS: 2011 FLORIDA BUILDING CODE CHAPTER b OF ASCEl-10 BUILDING DESIGN: ENCLOSED ULTIMATE DESIGN WIND SPEED, 110 MPH NOMINAL DESIGN WIND SPEED- 132 MPH RISK CATEGORY: II INTERNAL PRESSURE COEFFICIENT: + •IS/ •15 EXPOSURE CATEGORY: " B WALLS (ENCLOSEDr 33 Pa> F. IMPACT PROTECTION: IMPACT RES15TANT DOORS 4 WINDOWS COMPONENTS 4 WALL CLADDING: ZONE 4 ZONE 5 10 SQ. FT. "+ 40.0 / - 41b PSF. 10 60. FT. _ , 44,0 / - 58.8 P.S.F. 20 $0, FT. _, 47.0 / - 45A PSF. 20 60, FT. ", 420 I - 54.3 PSF, 50 SQ. FT. •, 393 / - 43.1 PSF, 50 60. FT.", 393 / - 4S.6 PSF. 100 50, FT. q, 31A / - 410 PSF, 100 SQ. FT. ", 37A / . 45b PSF, O W y i r a35��m u� W. IIp aWu nn� �U � a o a� !� Its rip, 1/2" DRYWALL Q HARDI PLANK SIDING ON 30# FELT ON 1/2" C,D.X, PLYWOOD 2" X 6" STUDS a ANCHOR JAMB W/ FOUR 311 X 3/8" (#S) WOOD SCREWS PER SIDE DOOR CASING I" X 3" TRIM D= 0 0 5EALANT —FIR JAMB --_'`—ALUM. CONCRETE SILL ------/ THRESHOLD �4 � 1 3/4" FRENCHWOOD HINGED PATIO DOOR OUTSWING Q EXTE « COR DAME) DETAIL 1 1/2'� EXISTING 48" OVER -HANG ti SIMPSON A23 —9 16" OlC EXISTING FASCIA EXISTING SOFFIT ICYNENE FOA' 1 INSULATION R,•20 DOUBLE TOP PLATE b/811 GYP. BD. CEILING 1/2" GYP. BD, INTERIOR FINISH EXISTING PROPOSED COVERED PORCH FOYER SIMPSON $P4 6 HARDIE-PLANK SIDING ON TYVEK HOUSE WRAP ON TOP t BOTTOM 1/2" CDX. PLYWOOD ON OF EACH STUD 2" x 4" WOOD FRAMING 9 16" O/C W/ R-I3 FIBER -GLASS 5/8" X 8" WEDGE GATT INSULATION ANCHORS oa 32" O/C 2" X 4 " PRESSURE TREATED SILL PLATE EXISTING SLAB WOOD BASE TRIM EXISTING ROOFING - EXISTING 2" X 6 " JOIST 9 24" O/C EXISTING CEILING EXISTING LAUNDRY EXISTING STUD WALL o , EXISTING THICKENED SLAB EDGE A FEI: LUA EXISTING THICKENED SLAB EDGE SECTION LU Q/ O U_ LY 11.1 O a LLt LU � � Z w O (L LU [Z - z <) 0 m >n 9EB166®0$ j�2✓�I l ,� l9/d- oy� 20104= RECEIVED 14 JAN 20 O/�' 1 FLAN_ I L E COPY, LAN1PLO1 /F1___1I \Inty, P@rmittMg I/4" -I,-Oil til 77��� Y QUO/G Iq(�iM f / OF ONE REVIEWED FOR IUALL LEGEND CODE COMPLIANCE 1%` " T EXISTING 2" X 4" FRAME WALL ST" L CIE COUN Y 1 �Ze� O EXISTING 2" X 6" FRAME WALL BOCC EXISTING 6" C.M.U. WALL ��— PROPOSED 2" X 4" FRAME WALL