HomeMy WebLinkAbout205091-1d Compaction - signedHeadquarters
11345 U.S. Highway 1
Sebastian, FL. 32958
Orlando
723 Progress Way
Sanford, FL. 32771
Mailing
PO Box 78-1377
Sebastian, FL. 32978
Phone: 772-589-0712
C.A.# 5693
KSMengineering.net
October 14, 2020 KSM JOB # :205091-1d/CH/jo
CONTRACTOR:South Florida Land Clearing
15701 Orange Avenue
Fort Pierce, Florida
JOB LOCATION:10009 South Indian River Drive
Fort Pierce, Florida
PERMIT #:2009-0270
To Whom it may concern,
Should you have any question, please feel free to contact our office.
Respectfully,
Bryan E. Dahlke, P.E.
V.P. of Engineering
PE # 81439 10/14/20
Email to: St Lucie Building Department; sflcgw@gmail.com
Enclosed, please find the nuclear density test results performed on the barn pad at the above referenced project.
Proudly Serving Florida since 1990
Headquarters
11345 U.S. Highway 1
Sebastian, FL. 32958
Orlando
723 Progress Way
Sanford, FL. 32771
Mailing
PO Box 78-1377
Sebastian, FL. 32978
Phone: 772-589-0712
C.A.# 5693
KSMengineering.net
October 9, 2020 KSM JOB # :205091-1d/CH/jo
2009-0270 NUC #417
South Florida Land Clearing Nuc Model:3500
10009 South Indian River Drive Nuc Serial #:3417
Fort Pierce, Florida
Compacted Foundation Fill
#TEST LOCATION
OF SAMPLE DEPTH PEN
READ
DRY
DENSITY
MAX. DRY
PROCTOR VALUE (P.C.F.)
PERCENT
COMPACTION
Barn Pad
1 S.W.0" - 12"43 106.4 110.1 96.6%
2 Center "45 107.0 "97.2%
3 N.E."43 106.6 "96.8%
4 S.W."106.4 "96.6%
5 Center "106.4 "96.6%
Proctor Optimum Moisture:
@ Test Locations the Density &
10/14/2020
Proudly Serving Florida since 1990
PE # 81439
DATE TESTED:
PERMIT #:
CONTRACTOR:
JOB LOCATION:
ITEM TESTED:
Degree of Compaction Meets
Minimum Requirement
SOIL COMPACTION REPORT
ASTM D 1557 and ASTM D 6938
Soil Description:
Grayish Brown Sand
In Place Moisture:
Proctor Max. Dry Density: P.C.F.
12.0%
13.0%
Disclaimer:Contractor is responsible to
maintain the tested area in the condition that
KSM completed the indicated passed
compaction test.KSM is not responsible if the
tested area has been altered from the approved
inspected condition.
110.1
Penetrometer reading indicate the
for Unstaked Foundation
Bryan E. Dahlke, P.E.
V.P. of Engineering
Headquarters
11345 U.S. Highway 1
Sebastian, FL. 32958
Orlando
723 Progress Way
Sanford, FL. 32771
Mailing
PO Box 78-1377
Sebastian, FL. 32978
Phone: 772-589-0712
C.A.# 5693
KSMengineering.net
DATE TESTED:October 9, 2020 KSM JOB # :205091-1d/CH/jo
PERMIT #:2009-0270
CONTRACTOR:South Florida Land Clearing
JOB LOCATION:10009 South Indian River Drive
Fort Pierce, Florida
Soil Description:
Grayish Brown Sand
Proctor Optimum Moisture:
12.0%
Proctor Max. Dry Density: P.C.F.
110.1
Bryan E. Dahlke, P.E.
V.P. of Engineering
PE # 81439 10/14/2020
SOIL COMPACTION REPORT
ASTM D 1557
Proudly Serving Florida since 1990
107.0
108.0
109.0
110.0
111.0
112.0
9 10 11 12 13 14 15
W
E
I
G
H
T
P
.
C
.
F
.
D
R
Y