Loading...
HomeMy WebLinkAboutConstruction PlansSETUP AND INSTALLATION OF SINGLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION ON SCHEDULE 40 PVC TO ALLOW FOR MOVEMENT TO PLUM OR SQUARE UNIT TO HOUSE, FENCE, PROPERTY LINE, ETC. 2. ONCE UNIT IS SQUARE AND THE HIGH SPOT OF THE GROUND IS ESTABLISHED, THE BUILDING IS BLOCKED ON THE HIGH SPOT AND LEVELED. THE OTHER END OF THE BUILDING IS BROUGHT UP TO LEVEL AND BLOCKED. THEN THE CENTER OF THE BUILDING IS SUPPORTED TO LEVEL, BLOCKED, AND THEN SHIMMED. 3. AFTER THE BUILDING IS LEVEL, MORE BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 4. ANCHOR PLACEMENT IS ESTABLISHED BY THE WIDTH OF THE BUILDING. HOLES ARE DRILLED THRU THE 2"x4" BOTTOM PLATE WITH A 1/2" AUGER BIT. 1/2" EYEBOLT OR OPTIONAL 1/2" THREADED ROD (FOR A "HIGH SET") IS SECURED THRU THE HOLE. 5. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. 6. IF THE UNIT HAS A FLOOR, EITHER A HOLE IS DUG FOR THE 30" AUGER ANCHOR AND BACKFILLED AND SECURED AS PER THE DETAIL OR A 1/2- HOLE IS DRILLED INTO THE CONCRETE 1-1/2" OFF OF RIM JOIST. THE EYEBOLT IS FASTENED THRU THE BOTTOM PLATE AND A SIMPSON A-24 (OR EQUAL) IS SECURED TO THE CONCRETE WITH A 1/2" WEDGE ANCHOR. 7. IF THE UNIT IS A 'NO FLOOR' OPTION, ANCHOR WITH 1/2"x5" WEDGE ANCHOR THRU THE 2"x4" BOTTOM PLATE. TABLE 1 A CHORI G TO CONCRETE SHED WIDTH UPLIFT (PLF) ANCHOR SPACING 20'-0" 400 S-6" 13'-8" 280 3'-0" 240 S-e 10'-0" 200 3'-0" 160 3-0. 6'-0" 120 3-0^ TABLE 2 SKID RUNNER SPACING* SHED WIDTH Xt X2 X3 1'-1q" 2'-8" 6'-4• - 10'-0" V-7" 6'-10" - 8'-0" 0'-9" 6'-6" - 6'-0" 0'-10" 51" - -VALUES ARE FROM END OF JOIST TO CENTERS OF (2) 4'x4" SKIDS ONLY. 13'-8" WIDE SHEDS HAVE (4) SETS OF SKIDS. T 30" AUGER ANCHOR (4,900LB) INSTALLED PER MANUFACTURER'S INSTRUCTIONS. EYELET AT MAXIMUM OF 6" ABOVE GRADE. SETUP AND INSTALLATION OF DOUBLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION. THE FIRST SECTION OF THE DOUBLE WIDE IS PLACED ON THE HIGHEST LOCATION OF GROUND AND IS LEVELED UP. 2. BLOCKS ARE THEN PLACED AT THE END, CENTER, AND OTHER END TO LEVEL ONCE THE BUILDING IS LEVEL, BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 3. THE NEXT SECTION OF THE SHED IS BACKED INTO PLACE AND UNLOADED PARALLEL WITH THE FIRST SECTION. THE TWO SECTIONS ARE CONNECTED AT THE LOWER CORNER WITH (1 �%44" BOLT AND NUT. THE SECOND SECTION IS THEN LEVELED AND THE OTHER BOLT HOLES ARE LINED UP AND BOLTED SECURE. THE REST OF THE BLOCKING IS THEN COMPLETED. THIS PROCEDURE IS REPEATED FOR MULTIPLE SECTION SHEDS UNTIL ALL SECTIONS ARE IN PLACE. 4. GROUND ANCHORS ARE THEN ADDED (SEE TABLE 4B). 5. ONCE THE BUILDING IS PROPERLY BLOCKED AND BOLTED TOGETHER, THE SUPPORT BRACING IS REMOVED. 6. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. TABLE 3A PAD TYPES TYPE PAD DIMENSIONS MAX. LOAD" MATERIAL I 2"x8"x16" 1778LBS CONCRETE BLOCK QUALITY CEMENT AND SAND MIX II 4"x8"x16" 3500LBS CONCRETE BLOCK QUALITY CEMENT AND SAND MIX III 16"06" 3950LBS ABS PLASTIC PADS IV 8"x8"x16" 1900LBS CO CRETE BLOCK QU TY CEMENT AND SAND MIX * BASED ON 2000PSF SOIL BEARING CAPACITY (2000PSF IS TYPICAL) NOTES 1. HOLLOW OR SOLID CONCRETE BLOCKS (8"W06") MAY BE STACKED ON PADS FOR HIGH SETS UP TO 48' WITHOUT REINFORCING. 2. ABS PADS REQUIRED ON 11'-8" AND 13'-8" WIDE SHEDS ONLY. TABLE 3 SUPPORT FOOTING PAD SPACING FOR RUNNER BLOCKING FOR SINGLE & DOUBLE WIDE SHEDS SHED DESCRIPTION PAD MAXIMUM LOAD AND PAD TYPE SHED WIDTH TYPE LW*(PLF) END PAD MAX. SPACING END PAD SIDE RUNNER PAD TYPE INTERIOR PAD SIDE RUNNER PAD TYPE SW/DW 4.15/332 0" TO 6" 6'-0" 1936LB I, II, III, OR IV 1879LB I, II, III, OR IV SW/DW 6.00/480 0" TD 6" 6'-0' 2558LB I, II, III, OR IV 2558LB I, II, III, OR IV 10'-0" SW/DW 5.00/400 0" TO 6" 6'-0" 2400LB I, II, III, OR IV 2400LB I, II, III, OR IV 8'-0" SW 4.00/320 0" TO 6" 6'-0" 2029LB I, II, III, OR IV 2133LB I, II, III, OR IV 6'-0' sW 3.00/240 0" TO 6" 6'-0' 1658LB I, II, III, OR IV 1866LB I, II, III, OR IV * LOAD WIDTH OF UPUFT ON RUNNER NOTES 1. PAD SPACING IS END TO CENTER OF PAD, 2. PADS OTHER THAN END PADS SPACING IS CENTER TO CENTER. 3. USE SAME MAXIMUM SPACING FOR INTERIOR SPACING. GENERAL NOTES & SPECIFICATIONS FOR AUGER ANCHORS 1. BUILDING ANCHORS SHALL BE "MOBILE HOME" TYPE HP-1 SINGLE HELIX EYE AUGER ANCHOR BY HOME PRIDE OF BRISTOL, VA. OR EQUAL. AVERAGE HOLDING STRENGTH IS NOT LESS THAN 4,900 LBS. 2. ANCHORING SYSTEM TO GROUND PER LOCAL BUILDING CODE (BY DEALER). LOCATE ANCHORS PER TABLE 4A OR 4B. 3. THREADED ROD WITH EYEBOLTS SHALL BE PLACED THRU THE BOTTOM PLATE (FLOOR SYSTEM) AND ATTACHED TO ANCHOR. THESE CAN BE EXTENDED WITH THREADED ROD (OR STRAPS WITH EQUAL OR GREATER STRENGTH) FOR ELEVATED PORTIONS OF SHEDS ON LEVELING BLOCKS. TABLE 4A 30" AUGER ANCHOR SPACING - SINGLE WIDE SHED WIDTH LW* UPLIFT (PLF) END ANCHOR** MAX. INTERIOR SPACING*** 13'-8" 7.00 243 6-d' TO S-O" 10'-0" 11'-8" 5.00 208 0'-0" TO S-0" 10'-0" 10.-0., - 5.00 174 Y-w TO S-G" 10'-0..�� 6'-0" 3.00 104 0'-0" TO 3'-W 1O,_O" TABLE B 30" AUGER ANCHOR SPACING - DOUBLE WIDE SHED WIDTH LW* UPLIFT (PLF) END ANCHOR** MAX. INTERIOR SPACING*** 20'-0" 10.00 400 V-0" TO 3'-W 5'-0" :*LOAD WIDTH OF UPLIFT ON RUNNER ***LOCATION FROM END WALL OF AUGER ANCHOR MAXIMUM SPACING BETWEEN ANCHORS i. NOTES SPACING IS DESIGNED AS PER ASCE-7. 2. ALL MEASUREMENTS ARE CENTER -TO -CENTER. 3. THE MINIMUM NUMBER OF ANCHORS PER SHED IS (4). (1) ANCHOR PER EACH CORNER. ADDITIONAL INTERIOR ANCHORS ARE REQUIRED IF SPACING IS MORE THAN 10'-0' BETWEEN ANCHORS.. 4. ANCHORS SHALL BE ON SIDE WALLS EXCEPT WHEN THE SHED IS PLACED NEXT TO AN EXISTING BUILDING; IN WHICH ANCHORS CAN BE PLACED ON THE END WALLS AS CLOSE TO THE SIDE AS POSSIBLE. Y-- w. 2"x2" GALVANIZED WASHER c , 2"xZ" GALVANIZED WASHER WITH 1/2' NUT WITH 1/2" NUT . f _ OPTIONAL DE 'HIGH SEL' - FOR- NOTCH OR COUNTERSINK BOLT 1/2' THREADED ROD OPTIONAL FOR "HIGH SET' 1/2" COUPLER _ EYES BOLTED TOGETHER WITH 1/2"x2" BOLT & NUT WITH (2)2'x2' GALVANIZED .�� •. 1/2 COUPLER,, f - WASHERS (2.000LB SHEAR CAPACffY)` 1: i1� / MIN. THRU 2"x4" BOTTOM PLATE 2"x4" BOTTOM PLATE NAILED TO 2"x6' P.T. BASE 1/Z"x5" (400 LB.) I• MIN. 1/2'z12' FORGED EYEBOLTI'y _ d-..w1�M WEDGE ANCHOR INTO SLAB INTOCONSLAB-----1- THRU 2'x4' P.T. BOTTOM PLATE I EYES BOLTED TOGETHER WITH 1/2"x2' •011g#.y�p�p �f (SEE TABLE 1 FOR SPACING) -----_-' A-----1 TYPE I. II. III. OR IV PAD WITH BOLT & NUT WITH (2)2 x2" GALVANIZED '�` WASHERS (2.000LB SHEAR CAPACITY) BLOCKING AS REQUIRED (SEE TABLE 3). 1/2'x3 40O,tiLB.')i� � SIMPSQN°A-.24 - CONC�REfFI SLAB BY OTHERS THROUGH � �,.v CONCRETE WEDGE�ANCF OR CLIPsOR EQUAL LOCAL CODES AND JURISDICTION (SEE TABLE 1 FOR SPACING) • �� CONCRETE SLAB BY OTHERS THROUGH LOCAL CODES AND JURISDICTION 30" EARTH AUGER ANCHOR TABLE 4 FOR SPACING) � � 'NO (SEE SHED WITH SKID SHED' WITH-SKCD � SHED WITH FLOOR' OPTION TO PAD OR BLOCKING GANCHORED-TO-CONCRETE ANCHORED TO CONCRETE DTI D`0WN DETAILS CODE VERSION I FOC 2017 am EM.. ASCE-7 MANUFACTURER SUPERIOR SHEDS BUILDING TYPE i9C""" u NSEORACE CONSTRUCTION TYPE v-B FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY MIORAGE ALLOWABLE NUMBER of STORIES 1 BASIC WIND SPEED V-1w.ph ENCLOSURE ENCLOSED INTERNAL PRESSURE COEFFICIENT +/- 0.18 IMPORTANCE FACTOR LIS ROOF DEAD LOAD 10PSF ROOF LIVE LOAD 2OPSF OR 300Ihe FLOOR DEAD LOAD 8PSF FLOOR LIVE LOAD STD. 75PSF - 125PSF OPT. "R' RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE LESS THAN 720 SOFT. DESCRI 1 2017 FFHC 11,112/17 M1B 2 GROUND ANCHOR 6' AF.c MAX., ANcuoR Ex1ENsaN s/za/1a M1B V) - MTB Q Date: Ld 4/26/16 Scale: (n odel N A LLJ ALL GENERAL NOTES 1. FOUNDATION PLANS ARE NOT PART OF THIS PLAN SET AND ARE GOVERNED BY LOCAL JURISDICTION. LLJ 2. THIS BUILDING Is EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION J 1015.22. m 3. REFER TO TIE -DOWN DETAILS FOR PROPER :D INSTALLATION REQUIREMENTS TO MEET CODE. Q 0 0 2/5/20 Q _ MQttheW T. B&IdWini"PE! �f ETocid a_Ltcen se-#64608 lal U) z Sheet: AD- 1 Or 1 Side Wall Header Schedule (180C) End Wall Header Schedule (180C) 2018-12-20 TOP LINE ENGINEERING APPROVAL PLAN #SS-B-1-C �.. Sl2e d Max. San N Fasteners w/o strap + Building Width { } P J[b} (each end)(c)" D4 ALUMINUM ROOF SHEATHING Fasteners w/ strap Size Up to 14' Wide 1-2"x4° F- 0 4-3" x 0.131" nails ... ....... ..... .............._............_..__.._.._...._..-. 0'-0" MAX. Max. Span NJ{b) (each end) 2-2'x4"(c) 9 O' o{d} 6 - 3° x 0.131' nails 1" 1-4"x4" 6'-0" 0 3 3° D 131 ° 'I a. Tabulated values are for No. 2 grade Spruce -Pine -Fir lumber. -� ( 1 fO 0 M 0 1x RUNNERS 0 W w END W TRUSS 2"x4' TRUSS 0 24" O.C. MAX. - x nal s , b NJ - Number ofjack studs required to support each end. 4°x4' w2"x4° 8'-0" 1 6 - 3' x 0.131 ° nails a. Tabulated values are for No. 2 grade Spruce�ine Fir lumber. c. Laid flat b. NJ - Number ofjack studs required to support each end. d. No Jack studs, but 2x6 studs laid flat. c. Window header for window openings that hake more than 50% combined stud wall above . 2 and below, otherwise use door header schedule. -NOTES ... � ? Cl. See header details for aftemate layouts, i.e. 2 2 1. SEE FASTENER SQ40UE FOR HARDWARE"x4" or 4"x4" P.T. 2. SEE sa+E VE DRN� �� ABOVEA HAVE aEDOrl e. The header can be attached to the top plate and thus have the combined strength BELOW, OT ERWiSE REFER To DOOR H9DER% CODE INFORMATION equivalent and use the maximum span stated. CODE VERSION FDO 2017 ft Effd M1 Afia-T• 2014 NO MANUFACTURER SUPERIOR SHEDS WALL STUDS 1 i BUILDING TYPE OF RED BLRU) G II RESIOEMW. $FORAGE CONSTRUCTION TYPE v-8 SOIGLE 2'.4' EXTERIIOR HEADER FIRE PROTECTION NONE SHEATHING I I I I I I FIRE SUPPRESSION SYSTEM NONE j 1 i 1 (2) z W WITH 1/2• PLYWOOD I I I - OR OSB FILLER OR (Q'V"• 2W OCCUPANCY STORAGE I I1 12'.1z' OR i6-.4- BETWEEN 4•.4' ALLOWABLE NUMBER OF STORIES 1 , L 11 WALL STUDS VENT IS SECURED ro sHFATHNc AS PER 12' MAX. BASIC WIND SPEED V�iBOmph MANUFACR' NMI CIIONS HYDROVENT DETAIL SIDE WALL WINDOWS END WALLS WINDOWS & EXPOSURE C OPTIC AL & DOORS DOOR 6' WIDE OR LESS 4"x" W/2"x4" ENCLOSURE 94MDSED INFERNAL PRESSURE COEFFICIENT +/- O.ta IMPORTANCE FACTOR 1.15 ROOF DEAD LOAD ,OPW OUTLET NOTES -OPTIONAL ELECTRIC ROOF LIVE LOAD 3ovsF OR 30gb POINT LOAD -ALL WIRING SHALL BE 14 GAGE 3-WIRE MC CABLE.--T';�'.�,..r �ror 1,NF rnr:,uernc�:e. qc FLOOR DEAD LOAD 1OPS N LL -ENCASE IN ALL METAL BOXES. �amE. ��-rr� N'ill,am E. \vary, III FLOOR LIVE LOAD STD. 7EPSF - 126PSF OPT. DESIGN PRESSURES SOURCE L 11 SNIP-51, SMI-79, ICC SIRS040 'R' RATING N/A ROOF +27.8 -94.7 ROOF FRAMING PLAN WIRING DIAGRAM 106S9OakviewPOinteTe;Tace OF WALLS, FLOOR, ROOF MODULES PER BUILDING , WALLS/DOORS/ INDOWS +32.6/-29.2 (OPTIONAL) Gotha, Florida 34734 HURRICANE PROTECTION USAGE NO - HURRICANE SHELTER USAGE NO Wr ALPINE 2W END *ALL •DOOR m WINDOW LOCATIONS VARY SQUARE FOOTAGE 710 SOtT. OR LESS QUAL REVISIONS REVISIONS ss s `F COLLARmaw,�NE z , EffAD DETAIL REV DATE BY OR EC I 4a I SHEATHR0NG OPTIONS ME HEADER iUx 2.4 u• o.C. 1z4 RUNNER ON INSIDE W Z DmWn BY MTB 2a 0 END A1L5 / i ; : j9 > / J Z Date; 12/12/17 END WALL O Scal= �I�.-. N/A .4 2STUDS O T 4 SOLE PLATE (n w vcI 2z4 SOLE PLATE 2,4 SOLE PLATE 24 O.C. MA,L FLOOR FRAMING (n SS-B-180C � 1. DAT1 PLANS ARE NOT PART OF THIS PLAN SET AND Afar FLOOR FRAMNG GOVERNED BY LOCAL JURLSDICr10N- SnIDS SECURED TO SOLE PLATE J LLJCODE 2. THIS BUILDING IS DIEMPT FROM THE FOG ENERGY CONSEINATION PER SECTIO 1016.ZZ LJ . _ AND FLOOR FRAMING WITH 0.030' (1mm).12• STRAP W/a-1m NAILS STANDARD WALL DETAIL NOTE WALL. FRAMING MEMBERS ARE CONTINUOUS FROM Q � 3. REFER roTIE- OETA65 FOR PROPER NsduATI011 REQUIREMENTS TO CODE LJ ARE$ 6•-0• ro t3'�' LJ LJ OR EQUAL FLOOR SHFATHNG: WITH DOOR & WINDOW OPTIONS FOUNDATION SILL TO ROOF AND SEW TQ ENSUIE A CONTINUOUS LOAD PATH. _ IYHy WJLLL�RI4�S ATE ~ O 4. ALL STUDS, RAFTQS, TRUSSES, ELC. ARE 2.4 (f2 SPF, EXCEPT As Norm. —VARIES s'-0' TO 13-E- - 3/4• PLYWOOD Nor CONTINllgqUUS5,, SHEET METAL PS, TIES, OR CLPS (n (� S. STRUCTURES OVER 4W s0. Fi: WILL HAVE AN BO' MINIMUM ELEVATION CROSS-SECTION END ELEVATION P.T. ATTA 04D WITH - 3/4- P.T. PLYWOOD - 3/4' T&G SHALL EE F'ORIMED OF CALVAN® STEil OF Nor LESS THAN O'er' NOWNAL n90I LIJ DOOR 6. GUTTERS TO BE INSTALLED ON -SITE BY OTHERS THRU LaCAL TYPICAL ARCH FRAME WITH DOOR H24 H24 OR EOIfNALZM. AN AEG FOR ouANmY AND - 3/4' P.T. T&G '-D• 7. ALL WINDOWS AND Dom TO MEET THE MINIMUM SPECIFICATTONS u AS pm FLORIDA BUILDING CODE 8. FLAT METAL STRAPS dJ4 BE BEM AWND STRUCTURAL MEMBERS QF WALL $RIDS.. TRUSSES, CHorms, ETC. TO HELP SECURE THESE O T�z.4 um FIAT i ---- D ---- - -- - ---- --- ---- ---- ---- --- n ---- - -SOD LE RU 2 NEN6Fi6: PNDYIUFJ] THAT THE AOD[O) BEND DOES NOT INTERFERE A EXISTING @MtM 'E DS IN THE Snits. `\`� ::' •• • L\TENSE ••••'<�y��/ 'e-0O- v�c 6 er _ t9 I •WI.LES ME FPW DO OF J TO OM6 Co 4%C s.as mx ,d,Aac s� -w (4) SOS a= SI I '1 Ir - % I W • ` N 2.4 BLOCKING i F- � r rj�� WALLS o 18 2,4 BUDMNG q i Q � R g 21.6• LAID FLAT i C �_ 3 'y 1 2.6 P.T. 247 O.C. TYP. g I OPTION& 125PSF o 16' D.C. L / / �• STATE �' \ TYP. WITH 3/4• T&G PLYBOQ,D I / OF \ ''.• 2.4 SOLE RAM I 4•.4• P.T. ATTACHED WRH ODUANIMY I� � • F t 0 R 11) P r: '-•��\\ ' •v\ \` ' ''•••.. FLOOR FRAMING 2 FOR AND ; SPACING. ••••••• .• •�`\ 7TABLE O f io N A.� I -__I /// 11\ 1 LxJ LxJ LxJ LxJ j Q Matthew T. BQIdWin P.E. ARES 6'-0• TO 13'-r• -----VARIES 6'-W TO IS-B• -- x-- --- ---- ---- --- ---- ----___ -_---- ---- --- ---- ---- --- () END ELEVATION END ELEVATION Z Florida License #64608 WITHOUT DOOR WITH GARAGE DOOR FLOOR JOISTS SCHEDULE FOR S . EE SIZE (ONLY ON ENOWAW FLOOR FRAMING PLAN M Sheet_ S S B — 1 OF 1