HomeMy WebLinkAboutStefanakis Energy REV 10.15.20f a_ ZE.:� 3 -if) ( q2_ FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: STEFANAKIS RESIDENCE Builder Name: Street: S. INDIAN RIVER DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip. FORT PIERCE , FL, Permit Number: Owner. GEORGE AND HELEN STEFANAAKIS Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 j 1. New construction or e)dsting New (From Plans) 9. Wall Types (2005.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Polystyrene Bead AggrER=4.1 1567,00 W b. Frame - Wood, Adjacent R=11.0 438.67 ft' 3. Number of units; if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 3 d. N/A R= ft2 5. is this a worst case? No 10. Ceiling Types (2032.0 sgft.) Insulation Area a. Roof Deck (Unvented) R=20.0 2032.00 ft' 6. Conditioned floor area above grade (ft') 2032 b. N/A R= ft' Conditioned floor area below grade (W) 0 c. N/A R= ft' 11. Ducts R ft' 7. Windows(249.0 sgft.) Description Area a Sup: Attic, Ret: Attic, AH: AHU CLST 6 140 a U-Factor: SgI, U=0.33 120.33 ft' SHGC: SHGC=0.21 b. U-Factor: SgI, U=0.35 80.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.20 a. Central Unit 29.4 SEER:16.00 c. U-Factor: SgI, U=0.31 18.00 ft' SHGC: SHGC=0.18 13. Heating systems kBtu/hr Efficiency d. U-Factor. other (see details) 30.67 ft' a. Electric Strip Heat 27.0 COP:1.00 SHGC: other (see details) Area Weighted Average Overhang Depth: 7.084 ft. Area Weighted Average SHGC: 0.206 14. Hot water systems 8. Floor Types (2032.0 sgft.) Insulation Area a. Electric Tankless Cap: 1 gallons a. Slab -On -Grade Edge Insulation R=0.0 2032.00 ft' b. Conservation features EF: 0.900 b. N/A R= ft' None c. NiA R= ft' 15. Credits None Total Proposed Modified Loads: 61.33 Glass/Floor Area: 0.123 PASS Total Baseline Loads: 66.64 I hereby certify that the plans and specifications covered by Review of the plans and SHE ST j this calculation are in compliance with the Florida Energy Code. Code. specifications covered by this calculation indicates compliance O� AV of Florida Energy r, with the Code. z, 0 PREPA BY' ��'D Before construction is completed DATE: � 4"?2 this building will be inspected for ' .._ compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy C _� WE'Y OWNER/AGEN BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 10/14/2020 1:16 PM EnergyGai;ge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST RFPnRT PROJECT Title: STEFANAKIS RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2032 Lot # Owner Name: GEORGE AND HELEN STEF Total Stories: 1 Block/Subdivision: # of Units: 1 W orst Case: No PlatBook. Builder Name: Rotate Angle: 0 Street S. INDIAN RIVER DRIV Hermit Office: ST LUCIE COUNTY Cross Ven"on: No County. St Lucie Jurisdiction: ST LUCIE COUNTY Whole House fan: NO City, State, Zip: FORT PIERCE. Family Type: Single-family FL, New/Ebsting: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating- Design Daity Temp 1/ Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days- Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2032 19778.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infit ID Finished Cooled Heated 1 BEDROOM 2 159 1478.7 No 0 1 1 Yes Yes Yes 2 CLST 2 20 186 No 0 1 Yes Yes Yes 3 BATH 25 233 No 0 1 Yes Yes Yes 4 SINKS 25 232.5 No 0 1 No Yes Yes 5 PANTRY 78 725.4 No 0 1 Yes Yes Yes 6 BEDROOM 3 151 1404.3 No 0 1 1 Yes Yes Yes 7 CLST 3 15 139.5 No 0 1 No Yes Yes 8 AHU CLST 8 74.4 No 0 1 No Yes Yes 9 LINEN 20 186 No 0 1 No Yes Yes 10 LAUNDRY 118 1097.4 No 0 1 No Yes Yes 11 KITCHEN 170 1581 Yes 0 1 Yes Yes Yes 12 GREAT ROOM 549 5654.7 No 0 1 Yes Yes Yes 13 M HALL 68 632.4 No 0 1 No Yes Yes 14 HALL 64 595.2 No 0 1 No Yes Yes 15 M BATH 155 1441.5 No 0 1 Yes Yes Yes 16 M TOILET 15 139,5 No 0 1 No Yes Yes 17 MWIC2 30 279 No 0 1 No Yes Yes 18 M WIC 1 30 279 No 0 1 Yes Yes Yes 19 MASTER BEDROO 332 3419.6 No 0 1 1 Yes Yes Yes 10/14/2020 1:16 PM EnergyGaugeS USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPCIRT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BEDROOM 2 25 ft 0 159 112 1 0 0 2 Slab -On -Grade Edge Insulation CLST 2 2 ft 0 20 ft2 ee 1 0 0 3Slab-On-Grade Edge Insulation BATH 5 ft 0 25 ft' r 1 0 0 4 Slab -On -Grade Edge Insulation SINKS 1 ft 0 25 ft2 1 0 0 5 Slab -On -Grade Edge Insulation PANTRY E ft 0 78 ft' 1 0 0 6 Slab -On -Grade Edge Insulation BEDROOM 3 10.9 ft 0 151 ft2 e 1 0 0 7 Slab -On -Grade Edge Insulation CLST 3 1 ft 0 15 ft2 __ 1 0 0 8 Slab -On -Grade Edge Insulation AHU CLST 1 ft 0 8 ft2 1 0 0 9 Slab -On -Grade Edge Insulation LINEN 1 ft 0 20 ft2 e_ 1 0 0 10SSlab-On-Grade Edge Insulation LAUNDRY 1 ft 0 118 ft2 _ 1 0 0 11S1ab-On-Grade Edge lnsulaton KITCHEN loft 0 170 ft' _ 1 0 0 12SIab-On-Grade Edge Insulation GREAT ROOM 47 ft 0 549 ft2 1 0 0 13SIab-On-Grade Edge Insulation M HALL 1 ft 0 68 ft2 1 0 0 14SIab-On-Grade Edge Insulation HALL 1 ft 0 64 ft2 1 0 0 15SIab-On-Grade Edge Insulation M BATH lift 0 155 ft' 1 0 0 16SIab-On-Grade Edge Insulation M TOILET 1 ft 0 15 ft2 -- 1 0 0 17SIab-On-Grade Edge Insulation M W IC 2 1 ft 0 30 ft2 — 1 0 0 18SIabon-Grade Edge Insulation M W IC 1 6 ft 0 30 ft' _ 1 0 0 19SIab-On-Grade Edge Insulation MASTER BEDRO 36 ft 0 332 ft2 1 0 0 ROOF v Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 2273 ft2 0 ft2 Light N 0.2 No 0.9 No 20 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS iRCC 1 Full attic Unvented 0 2032ft' N N 10/14/2020 1:16 PM EnergyGauge®'USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) BEDROOM 2 0 Blown 159 ft' 0.1 Woad 2 Under Attic (Unvented) CLST 2 0 Blown 20 ft2 0.1 Wood 3 Under Attic (Unvented) BATH 0 Blown 25 ft2 0.1 Wood 4 under Attic (Unvented) SINKS 0 -Blown 25 ft2 0.1 Wood 5 Under Attic (Unvented) PANTRY 0 Blown 78 ft2 0.1 Wood 6 Under Attic (Unvented) BEDROOM 3 0 Blown 151 ft2 0.1 Wood 7 Under Attic (Unvented) CLST 3 0 Blown 15 ft2 0.1 Wood 8 Under Attic (Unvented) AHU CLST 0 Blown 8 ft2 0.1 Wood 9 Under Attic (Unvented) LINEN 0 Blown 20 ft' 0.1 Wood 10 Under Attic (Unvented) LAUNDRY 0 Blown 118 ft2 0.1 Wood 11 Under Attic (Unvented) KITCHEN 0 Blown 170 ft2 0.1 Wood 12 Under Attic (Unvented) GREAT ROOM 0 Blom 549 ft2 0.1 Wood 13 Under Attic (Unvented) M HALL 0 Blown 68 ft2 0.1 Wood 14 Under Attic {Unvented) HALL 0 Blown 64 ft' 0.1 Wood 15 Under Attic (Unvented) M BATH 0 Blown 155ft2 0.1 Wood 16 Under Attic (Unvented) M TOILET 0 Blown 15 ft2 0.1 Wood 17 Under Attic (Unvented) M W IC 2 0 Blown 30 ft2 0.1 Wood 18 Under Attic (Unvented) M W IC 1 0 Blown 30 ft2 0.1 Wood 19 Under Attic (Unvented) MASTER BEDRO 0 Blown 332 ft2 0.1 Wood WALLS Adjacent Space Cavity _Area Width Height Sheathing Framing Solar Below a 1 S Exterior Concrete Block - PolystyMSROOM 2 4.1 12 0 9 4 112.0 W 0 0 0.2 0 2 W Exterior Concrete Block - PolystyMBROOM 2 4.1 13 0 9 4 121.3 ft2 0 0 0.2 0 3 S Exterior Concrete Block - PolystyrenELST 2 4.1 2 0 9 4 1B.7 ft2 0 0 02 0 _ 4 S Exterior Concrete Block - Poiystyrend3ATH 4.1 5 0 9 4 46.7 ft' 0 0 02 0 5 S Exterior Concrete Block - PdystyreMANTRY 4A 6 0 9 4 56.0 ft2 0 0 02 0 6 W Exterior Concrete Block - PolWtyREBROOM 3 4.1 11 0 9 4 102.7 ft2 0 0 0.2 0 _ 7 N Garage Frame- Wood BEDROOM 3 11 14 0 9 4 130.7 ft2 0 0.1 02 0 8 E Garage Frame - Wood CLST 3 11 3 0 9 4 28.0 ft2 0 0.1 0.2 0 9 N Garage Frame -Wood CLST 3 11 2 0 9 4 18.7 ft' 0 0.1 0.2 0 10 N Garage Frame - Wood AHU CLST 11 2 0 9 4 18.7 ft' 0 0.1 0.2 0 11 W Garage Frame - Wood LAUNDRY 11 11 0 9 4 102.7 ft' 0 0.1 0.2 0 12 N Garage Frame - Wood LAUNDRY 11 2 0 9 4 18.7 ft2 0 0.1 0.2 0 13 S Exterior Concrete Black - PdystyreKkTGHEN 4.1 10 0 9 4 93.3 ft2 0 0 0.2 0 14 E Exterior Concrete Block - PolystytiWEAT ROO 4.1 27 0 10 4 279.0 ft' 0 0 0.2 0 15 S Exterior Concrete Bkxck- P*styQEAT ROO 4.1 20 0 10 4 206.7 ft' 0 0 02 0 _16 N Exterior Concrete Block - PolystyrerMBATH 4.1 11 0 9 4 102.7 ft' 0 0 0.2 0 17 W Garage Frame - Wood M BATH 11 13 0 9 4 121.3 ft2 0 0.1 0.2 0 18 N Exterior Concrete Block - PdWtyreiM W IC 1 4.1 6 0 9 4 56.0 ft2 0 0 0.2 0 _ 19 N Exterior Concrete Block - PolystyhWTER BE 4.1 18 0 10 4 186.0 ft' 0 0 0.2 0 20 E Exterior Concrete Block - PdWty#AA6TER BE 4.1 18 0 10 4 186.0-ft2 0 0 0.2 0 10114/2020 1:16 PM EnergyGaugeO USA 6.0.02 (Rev. 1)- FtaRes2017 FBC BtftEdition (2017) Compliant Software Page 4 of 6 FORM R405-2017 FNPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. V # Wall Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Overhang Depth Separation Int Shade Screening 1 2 3 4 5 6 7 B 9 10 S 1 Vinyl W 2 Vinyl S 4 Vinyl W 6 Vinyl E 14 Vinyl E 14 Vinyl S 15 Vinyl N 16 Vinyl N 19 Vinyl E 20 Vinyl Low-E Single Low-E Single Law-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 0.29 0.23 Y 17.3 W 0.33 0.21 Y 8.0 ft' 0.31 0.18 Y 6.0 ft' 0.33 D21 Y 17.3ft' 0.35 0.21 Y 13.3 ft' 0.35 0.2 Y 80.0 ft' 0.33 0.21 Y 30.0 ft' 0.31 0.18 Y 12.0 ft' 0.33 0.21 Y 20.0 ft' 0.33 0.21 Y 45.0 W 1 ft 0 in 1 ft 0 in 1 ft 0 in 1 ft0 in 10 ft 0 in 10 ft 0 in 10 ft 0 in 1 ft 0 in 1 ft 0 in 10 ft 0 in 1 It 4 in 1 ft 4 in 1 ft 4 in 1 ft4 in 1 ft 4 in 1 It 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in None None None None None Drapes/blinds Drapes/blinds None None None None None None None None Exterior 5 Exterior 5 None None None GARAGE # Floor Area Ceding Area Exposed Wall Perimeter Avg_ Wall Height Exposed Wad Insulation 1 480 ft' 480 ft' 44 ft 9 ft 11 W&TRATaON # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000433 2307.6 126.68 238.24 .1623 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Spot Single SEER: 16 29.4 kBtu/hr 882 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tankless Exterior 0.9 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC C Nt # Company (Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft' 10/14/2020 1:16 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPC3RT DUCTS v — Supply-- — Return -- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 140 ft2 Attic 14 ft2 Default Leakage AHU CLST (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat N Ceiffng Fans: Codin an Feb HeatinH Jan Feb (] {X) Mar Mar A r E j Apr f Ma May Jun f Jun Jul Jul (Xj A [ j AugSep S Oct f Oct Nov Nov Dec Dec VentingJan Feb [XJ Mar [X) Apr [ may [ Jun Jul [) Augu [ Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 8080 80 80 M 80 80 80 80 78 78 78 78 7788 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 M 68 68 68 68 66 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Defauft(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft2 ft 0.3 HALL Defauft(8 Ibs/sq.ft. ft2 ft 0.3 M BATH 1 Defauk(8 Ibs/sq_ft. ft2 ft 0.3 LAUNDRY Defauft(8 Ibs/sq.ft. ft2 ft 0.3 M W IC 1 Defauft(8 lbs/sq.ft. ft2 ft 0.3 PANTRY Defauit(S lbs)sgJt. 1`12 ft 1).3 FOYER Default(S Ibs/sq.ft. ft2 ft 0.3 KITCHEN Defauft(8 tbs/sq.ft ft2 ft 0-3 MASTER BEDROO Defauft(8 lbs/sq.ft. ft2 ft 0.3 M BATH 2 Defauft(8 Ibs/sq.ft. ft2 ft 0.3 M WIC 2 Defauft(8lbs/sq#t. ft2 it 0.3 BEDROOM 2 Defauft(8 lbs/sq.ft. ft2 ft 0.3 CLST 2 Defauft(8 Ibs/sq.ft. ft2 ft 0.3 DEN CLST Default(8 lbsfsq.ft. ft2 ft 0.3 DEN Defauft(8 Ibs/sq.ft. ft2 ft 0.3 BATH 3 Defauft(8 Ibs/sq.ft. ft2 ft 0.3 FOYER HALL DefaukIS kW—ft— ft2 ft 0.3 GREAT RM 10/14/2020 1:16'PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 pe'r µ�� Z,603 - ob 142- 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 92 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location AHU CLST 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 29.4 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2032 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.333 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.206 c) Area 7c. 249.0 8. Skylights a) U-factor: (weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (insulation -R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.1 10131. 11.0 10132. I la. 0.0 11b. 11 c. 11d. No 14. Heating system: Capacity 27.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.90 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF f) Heat recovery unit HeatRec% g) Other 16. HVAC credits claimed (Performance Method) a) Ceiling fans b) Cross ventilation No c) Whole house fan No d) Multizone cooling credit e) Multizone heating credit f) Programmable thermostat No 'Label required by Section R303.1.3-of the Florida Building Code, Energy Conservation, if not DEFAULT. certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Hgne: S. INDIAN RIVER DRIVE City/FL Zip: FORT PIERCE, FL 10/14/2020 1:17:25 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 0(oZ 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: STEFANAKIS RESIDENCE Builder Name: Street, S. INDIAN RIVER DRiVE Permit Office; ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: x Owner: GEORGE AND HELEN STEFANIAKIS Jurisdiction: ST LUCIE COUNTY w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA, General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in an dro ed ceiling/soffit Y pp 9 /soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. kn•-S- The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior ,malls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the boft to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring ar plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and Wring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior wails boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addMon, inspect,on of log walls shall be in accordance with the provisions of ICC-400. 10/14/2020 1:17 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1