HomeMy WebLinkAboutStefanakis Energy REV 10.15.20f a_ ZE.:� 3 -if) ( q2_
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: STEFANAKIS RESIDENCE
Builder Name:
Street: S. INDIAN RIVER DRIVE
Permit Office: ST LUCIE COUNTY
City, State, Zip. FORT PIERCE , FL,
Permit Number:
Owner. GEORGE AND HELEN STEFANAAKIS
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 j
1. New construction or e)dsting New (From Plans)
9. Wall Types (2005.7 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Polystyrene Bead AggrER=4.1 1567,00 W
b. Frame - Wood, Adjacent
R=11.0 438.67 ft'
3. Number of units; if multiple family 1
c. N/A
R= ft'
4. Number of Bedrooms 3
d. N/A
R= ft2
5. is this a worst case? No
10. Ceiling Types (2032.0 sgft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 2032.00 ft'
6. Conditioned floor area above grade (ft') 2032
b. N/A
R= ft'
Conditioned floor area below grade (W) 0
c. N/A
R= ft'
11. Ducts
R ft'
7. Windows(249.0 sgft.) Description Area
a Sup: Attic, Ret: Attic, AH: AHU CLST
6 140
a U-Factor: SgI, U=0.33 120.33 ft'
SHGC: SHGC=0.21
b. U-Factor: SgI, U=0.35 80.00 ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.20
a. Central Unit
29.4 SEER:16.00
c. U-Factor: SgI, U=0.31 18.00 ft'
SHGC: SHGC=0.18
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. other (see details) 30.67 ft'
a. Electric Strip Heat
27.0 COP:1.00
SHGC: other (see details)
Area Weighted Average Overhang Depth: 7.084 ft.
Area Weighted Average SHGC: 0.206
14. Hot water systems
8. Floor Types (2032.0 sgft.) Insulation Area
a. Electric Tankless
Cap: 1 gallons
a. Slab -On -Grade Edge Insulation R=0.0 2032.00 ft'
b. Conservation features
EF: 0.900
b. N/A R= ft'
None
c. NiA R= ft'
15. Credits
None
Total Proposed Modified Loads: 61.33
Glass/Floor Area: 0.123
PASS
Total Baseline Loads: 66.64
I hereby certify that the plans and specifications covered by
Review of the plans and
SHE ST j
this calculation are in compliance with the Florida Energy
Code.
Code.
specifications covered by this
calculation indicates compliance
O�
AV
of
Florida Energy
r,
with the Code.
z, 0
PREPA BY'
��'D
Before construction is completed
DATE: � 4"?2
this building will be inspected for
'
.._
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy C
_�
WE'Y
OWNER/AGEN
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
10/14/2020 1:16 PM EnergyGai;ge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST RFPnRT
PROJECT
Title:
STEFANAKIS RESIDENCE
Bedrooms:
3
Address Type:
Street Address
Building Type:
User
Conditioned Area:
2032
Lot #
Owner Name:
GEORGE AND HELEN STEF
Total Stories:
1
Block/Subdivision:
# of Units:
1
W orst Case:
No
PlatBook.
Builder Name:
Rotate Angle:
0
Street
S. INDIAN RIVER DRIV
Hermit Office:
ST LUCIE COUNTY
Cross Ven"on:
No
County.
St Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House fan:
NO
City, State, Zip:
FORT PIERCE.
Family Type:
Single-family
FL,
New/Ebsting:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating-
Design Daity Temp
1/ Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days- Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2032
19778.6
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
Infit ID Finished Cooled
Heated
1
BEDROOM 2
159
1478.7 No
0
1
1
Yes
Yes
Yes
2
CLST 2
20
186 No
0
1
Yes
Yes
Yes
3
BATH
25
233 No
0
1
Yes
Yes
Yes
4
SINKS
25
232.5 No
0
1
No
Yes
Yes
5
PANTRY
78
725.4 No
0
1
Yes
Yes
Yes
6
BEDROOM 3
151
1404.3 No
0
1
1
Yes
Yes
Yes
7
CLST 3
15
139.5 No
0
1
No
Yes
Yes
8
AHU CLST
8
74.4 No
0
1
No
Yes
Yes
9
LINEN
20
186 No
0
1
No
Yes
Yes
10
LAUNDRY
118
1097.4 No
0
1
No
Yes
Yes
11
KITCHEN
170
1581 Yes
0
1
Yes
Yes
Yes
12
GREAT ROOM
549
5654.7 No
0
1
Yes
Yes
Yes
13
M HALL
68
632.4 No
0
1
No
Yes
Yes
14
HALL
64
595.2 No
0
1
No
Yes
Yes
15
M BATH
155
1441.5 No
0
1
Yes
Yes
Yes
16
M TOILET
15
139,5 No
0
1
No
Yes
Yes
17
MWIC2
30
279 No
0
1
No
Yes
Yes
18
M WIC 1
30
279 No
0
1
Yes
Yes
Yes
19
MASTER BEDROO
332
3419.6 No
0
1
1
Yes
Yes
Yes
10/14/2020 1:16 PM EnergyGaugeS USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPCIRT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
1 Slab -On -Grade Edge Insulation
BEDROOM 2
25 ft
0
159 112
1
0
0
2 Slab -On -Grade Edge Insulation
CLST 2
2 ft
0
20 ft2
ee
1
0
0
3Slab-On-Grade Edge Insulation
BATH
5 ft
0
25 ft'
r
1
0
0
4 Slab -On -Grade Edge Insulation
SINKS
1 ft
0
25 ft2
1
0
0
5 Slab -On -Grade Edge Insulation
PANTRY
E ft
0
78 ft'
1
0
0
6 Slab -On -Grade Edge Insulation
BEDROOM 3
10.9 ft
0
151 ft2
e
1
0
0
7 Slab -On -Grade Edge Insulation
CLST 3
1 ft
0
15 ft2
__
1
0
0
8 Slab -On -Grade Edge Insulation
AHU CLST
1 ft
0
8 ft2
1
0
0
9 Slab -On -Grade Edge Insulation
LINEN
1 ft
0
20 ft2
e_
1
0
0
10SSlab-On-Grade Edge Insulation
LAUNDRY
1 ft
0
118 ft2
_
1
0
0
11S1ab-On-Grade Edge lnsulaton
KITCHEN
loft
0
170 ft'
_
1
0
0
12SIab-On-Grade Edge Insulation
GREAT ROOM
47 ft
0
549 ft2
1
0
0
13SIab-On-Grade Edge Insulation
M HALL
1 ft
0
68 ft2
1
0
0
14SIab-On-Grade Edge Insulation
HALL
1 ft
0
64 ft2
1
0
0
15SIab-On-Grade Edge Insulation
M BATH
lift
0
155 ft'
1
0
0
16SIab-On-Grade Edge Insulation
M TOILET
1 ft
0
15 ft2
--
1
0
0
17SIab-On-Grade Edge Insulation
M W IC 2
1 ft
0
30 ft2
—
1
0
0
18SIabon-Grade Edge Insulation
M W IC 1
6 ft
0
30 ft'
_
1
0
0
19SIab-On-Grade Edge Insulation
MASTER BEDRO 36 ft
0
332 ft2
1
0
0
ROOF
v
Roof
Gable
Roof
Rad
Solar SA Emitt
Emitt
Deck
Pitch
# Type Materials
Area
Area
Color
Barr
Absor. Tested
Tested
Insul.
(deg)
1 Hip
Metal 2273 ft2
0 ft2
Light
N
0.2 No 0.9
No
20
26.6
ATTIC
/
V # Type
Ventilation
Vent Ratio (1 in)
Area
RBS iRCC
1 Full attic
Unvented
0
2032ft'
N N
10/14/2020 1:16 PM EnergyGauge®'USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) BEDROOM 2
0
Blown
159 ft'
0.1
Woad
2
Under Attic (Unvented) CLST 2
0
Blown
20 ft2
0.1
Wood
3
Under Attic (Unvented) BATH
0
Blown
25 ft2
0.1
Wood
4
under Attic (Unvented) SINKS
0
-Blown
25 ft2
0.1
Wood
5
Under Attic (Unvented) PANTRY
0
Blown
78 ft2
0.1
Wood
6
Under Attic (Unvented) BEDROOM 3
0
Blown
151 ft2
0.1
Wood
7
Under Attic (Unvented) CLST 3
0
Blown
15 ft2
0.1
Wood
8
Under Attic (Unvented) AHU CLST
0
Blown
8 ft2
0.1
Wood
9
Under Attic (Unvented) LINEN
0
Blown
20 ft'
0.1
Wood
10
Under Attic (Unvented) LAUNDRY
0
Blown
118 ft2
0.1
Wood
11
Under Attic (Unvented) KITCHEN
0
Blown
170 ft2
0.1
Wood
12
Under Attic (Unvented) GREAT ROOM
0
Blom
549 ft2
0.1
Wood
13
Under Attic (Unvented) M HALL
0
Blown
68 ft2
0.1
Wood
14
Under Attic {Unvented) HALL
0
Blown
64 ft'
0.1
Wood
15
Under Attic (Unvented) M BATH
0
Blown
155ft2
0.1
Wood
16
Under Attic (Unvented) M TOILET
0
Blown
15 ft2
0.1
Wood
17
Under Attic (Unvented) M W IC 2
0
Blown
30 ft2
0.1
Wood
18
Under Attic (Unvented) M W IC 1
0
Blown
30 ft2
0.1
Wood
19
Under Attic (Unvented) MASTER BEDRO
0
Blown
332 ft2
0.1
Wood
WALLS
Adjacent Space
Cavity
_Area
Width
Height
Sheathing Framing Solar
Below
a
1
S
Exterior Concrete Block - PolystyMSROOM 2
4.1
12
0 9
4
112.0 W
0
0
0.2
0
2
W
Exterior Concrete Block - PolystyMBROOM 2
4.1
13
0 9
4
121.3 ft2
0
0
0.2
0
3
S
Exterior Concrete Block - PolystyrenELST 2
4.1
2
0 9
4
1B.7 ft2
0
0
02
0
_ 4
S
Exterior Concrete Block - Poiystyrend3ATH
4.1
5
0 9
4
46.7 ft'
0
0
02
0
5
S
Exterior Concrete Block - PdystyreMANTRY
4A
6
0 9
4
56.0 ft2
0
0
02
0
6
W
Exterior Concrete Block - PolWtyREBROOM 3
4.1
11
0 9
4
102.7 ft2
0
0
0.2
0
_ 7
N
Garage Frame- Wood BEDROOM 3
11
14
0 9
4
130.7 ft2
0
0.1
02
0
8
E
Garage Frame - Wood CLST 3
11
3
0 9
4
28.0 ft2
0
0.1
0.2
0
9
N
Garage Frame -Wood CLST 3
11
2
0 9
4
18.7 ft'
0
0.1
0.2
0
10
N
Garage Frame - Wood AHU CLST
11
2
0 9
4
18.7 ft'
0
0.1
0.2
0
11
W
Garage Frame - Wood LAUNDRY
11
11
0 9
4
102.7 ft'
0
0.1
0.2
0
12
N
Garage Frame - Wood LAUNDRY
11
2
0 9
4
18.7 ft2
0
0.1
0.2
0
13
S
Exterior Concrete Black - PdystyreKkTGHEN
4.1
10
0 9
4
93.3 ft2
0
0
0.2
0
14
E
Exterior Concrete Block - PolystytiWEAT ROO
4.1
27
0 10
4
279.0 ft'
0
0
0.2
0
15
S
Exterior Concrete Bkxck- P*styQEAT ROO
4.1
20
0 10
4
206.7 ft'
0
0
02
0
_16
N
Exterior Concrete Block - PolystyrerMBATH
4.1
11
0 9
4
102.7 ft'
0
0
0.2
0
17
W
Garage Frame - Wood M BATH
11
13
0 9
4
121.3 ft2
0
0.1
0.2
0
18
N
Exterior Concrete Block - PdWtyreiM W IC 1
4.1
6
0 9
4
56.0 ft2
0
0
0.2
0
_ 19
N
Exterior Concrete Block - PolystyhWTER BE
4.1
18
0 10
4
186.0 ft'
0
0
0.2
0
20
E
Exterior Concrete Block - PdWty#AA6TER BE
4.1
18
0 10
4
186.0-ft2
0
0
0.2
0
10114/2020 1:16 PM EnergyGaugeO USA 6.0.02 (Rev. 1)- FtaRes2017 FBC BtftEdition (2017) Compliant Software Page 4 of 6
FORM R405-2017 FNPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
V #
Wall
Ornt ID Frame
Panes
NFRC
U-Factor SHGC Imp Area
Overhang
Depth Separation
Int Shade
Screening
1
2
3
4
5
6
7
B
9
10
S 1 Vinyl
W 2 Vinyl
S 4 Vinyl
W 6 Vinyl
E 14 Vinyl
E 14 Vinyl
S 15 Vinyl
N 16 Vinyl
N 19 Vinyl
E 20 Vinyl
Low-E Single
Low-E Single
Law-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
0.29 0.23 Y 17.3 W
0.33 0.21 Y 8.0 ft'
0.31 0.18 Y 6.0 ft'
0.33 D21 Y 17.3ft'
0.35 0.21 Y 13.3 ft'
0.35 0.2 Y 80.0 ft'
0.33 0.21 Y 30.0 ft'
0.31 0.18 Y 12.0 ft'
0.33 0.21 Y 20.0 ft'
0.33 0.21 Y 45.0 W
1 ft 0 in
1 ft 0 in
1 ft 0 in
1 ft0 in
10 ft 0 in
10 ft 0 in
10 ft 0 in
1 ft 0 in
1 ft 0 in
10 ft 0 in
1 It 4 in
1 ft 4 in
1 ft 4 in
1 ft4 in
1 ft 4 in
1 It 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
None
None
None
None
None
Drapes/blinds
Drapes/blinds
None
None
None
None
None
None
None
None
Exterior 5
Exterior 5
None
None
None
GARAGE
#
Floor Area
Ceding Area
Exposed Wall Perimeter Avg_ Wall Height
Exposed Wad Insulation
1
480 ft'
480 ft'
44 ft 9 ft
11
W&TRATaON
# Scope
Method
SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50)
.000433
2307.6 126.68 238.24
.1623
7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/
None
COPA 27 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity
Air Flow
SHR Block
Ducts
1
Central Unit/
Spot
Single SEER: 16 29.4 kBtu/hr 882 cfm
0.8 1
sys#1
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1
Electric
Tankless
Exterior
0.9 1 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
C Nt # Company (Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft'
10/14/2020 1:16 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPC3RT
DUCTS
v
— Supply--
—
Return --
Air
CFM 25
CFM25
HVAC #
# Location R-Value
Area
Location
Area
Leakage Type
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic
6
140 ft2
Attic
14 ft2
Default Leakage
AHU CLST
(Default) c(Default) c
1 1
TEMPERATURES
Programable Thermostat
N
Ceiffng Fans:
Codin an Feb
HeatinH Jan Feb
(]
{X)
Mar
Mar
A r
E j Apr
f
Ma
May
Jun
f Jun
Jul
Jul
(Xj A
[ j AugSep
S
Oct
f Oct
Nov
Nov
Dec
Dec
VentingJan
Feb
[XJ
Mar
[X) Apr
[
may
[ Jun
Jul
[) Augu
[ Se
[X] Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9 10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
8080
80
80
M
80
80
80
80
78
78
78
78
7788 78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
80
80
78
78
78
78
78 78
78
78
Heating (WD)
AM
65
65
65
65
65
65
65
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
68
68
Heating (WEH)
AM
65
65
65
65
65
65
65
68
68 68
68
68
M
68
68
68
68
66
68
68
68
68 68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Defauft(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
MASTER BEDROO
Default(8 lbs/sq.ft.
ft2
ft
0.3
HALL
Defauft(8 Ibs/sq.ft.
ft2
ft
0.3
M BATH 1
Defauk(8 Ibs/sq_ft.
ft2
ft
0.3
LAUNDRY
Defauft(8 Ibs/sq.ft.
ft2
ft
0.3
M W IC 1
Defauft(8 lbs/sq.ft.
ft2
ft
0.3
PANTRY
Defauit(S lbs)sgJt.
1`12
ft
1).3
FOYER
Default(S Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Defauft(8 tbs/sq.ft
ft2
ft
0-3
MASTER BEDROO
Defauft(8 lbs/sq.ft.
ft2
ft
0.3
M BATH 2
Defauft(8 Ibs/sq.ft.
ft2
ft
0.3
M WIC 2
Defauft(8lbs/sq#t.
ft2
it
0.3
BEDROOM 2
Defauft(8 lbs/sq.ft.
ft2
ft
0.3
CLST 2
Defauft(8 Ibs/sq.ft.
ft2
ft
0.3
DEN CLST
Default(8 lbsfsq.ft.
ft2
ft
0.3
DEN
Defauft(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 3
Defauft(8 Ibs/sq.ft.
ft2
ft
0.3
FOYER HALL
DefaukIS kW—ft—
ft2
ft
0.3
GREAT RM
10/14/2020 1:16'PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
pe'r µ�� Z,603 - ob 142-
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 92
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0
c) AHU location AHU CLST
3. No. of units (if multiple -family) 3. 1
4. Number of bedrooms 4. 3 13. Cooling system: Capacity 29.4
a) Split system SEER 16.0
5. Is this a worst case? (yes/no) 5. No b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.) 6. 2032 d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average) 7a. 0.333
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.206
c) Area 7c. 249.0
8. Skylights
a) U-factor: (weighted average) 8a. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (insulation -R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b.
9c.
10A1.
10A2. 4.1
10131. 11.0
10132.
I la. 0.0
11b.
11 c.
11d. No
14. Heating system: Capacity 27.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
c) Electric resistance COP 1.0
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
f) Other
15. Water heating system
a) Electric resistance EF 0.90
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF
f) Heat recovery unit HeatRec%
g) Other
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
b) Cross ventilation No
c) Whole house fan No
d) Multizone cooling credit
e) Multizone heating credit
f) Programmable thermostat No
'Label required by Section R303.1.3-of the Florida Building Code, Energy Conservation, if not DEFAULT.
certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Hgne: S. INDIAN RIVER DRIVE City/FL Zip: FORT PIERCE, FL
10/14/2020 1:17:25 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
0(oZ
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: STEFANAKIS RESIDENCE Builder Name:
Street, S. INDIAN RIVER DRiVE Permit Office; ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
x
Owner: GEORGE AND HELEN STEFANIAKIS Jurisdiction: ST LUCIE COUNTY
w
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA,
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in an dro ed ceiling/soffit
Y pp 9 /soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
kn•-S-
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior ,malls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the boft
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring ar
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and Wring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior wails
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
a. In addMon, inspect,on of log walls shall be in accordance with the provisions of ICC-400.
10/14/2020 1:17 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1