Loading...
HomeMy WebLinkAboutEnergy CodeIL FORM R405-2017 FLOR1DA.ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department.of Business and Professional Regulation - Residential Performance Method ProjectName: WYNNE THE WIND OR IMPACT BuilderName: WYNNE DEVELOPMENT \ Street: O V J�� V Permit Office: ST. LUCIE.COUNTY City, State, Zip: FT. PIERCE, FL, l PermitNumber: Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1432.0 sgft.) Insulation Area 2. Single familyor multiple family Single-family & Concrete Block - Int Insul, Exterior R=4.1' 1224.00 ft2 . b. Frame - Wood, Adjacent .R=11.0 208:00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms. 3 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1783.0 sgft.) Insulation Area a. UnderAttic (Vented) R=30.0 . 1753.00 ft2 6. Conditioned floorarea above grade (ft2) 1753 b. Knee Wall (Vented) R=19.0 30.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows (151.4 sqft.) Description Area a: Sup: Attic, Ret:.Attc, AH: Attic 6 175 a. U-Factor: Sgl, U=1.04 111.36 ft2 SHGC: SHGC=0.29 b. U=Factor: Sgl, U=1.11 40.00 ft2 12. Cooling systems k.Btu/hr Efficiency SHGC: SHGC=0:27 a. Central Unit 34.8 SEER:15.00 c. U-Factor.. N/A ft2 SHGC; 13. Heating.systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.850 ft. Area Weighted Average SHGC: 0.285 14. Hot water systems 8. Floor Types (1753.0 sgft.) Insulation Area a. Electric Cap:50 gallons a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features EF: 0.970 b. N/A R= ft2 None ' c. N/A R= ft2 15. Credits. Pstat Glass/Floor Area: Q.086 Total Proposed Modified Loads: 52.17 PASS Total Baseline Loads: 53.92 hereby certify that the plans and specifications covered by Review of the plans and .5 this calculation are in compliance with the Florida Energy Code. specifications covered_ by this indicates e � calculation compliance��� PREPARED By -. _. - _ with the Florida Energy Code: Before construction is completed DATE: -.. this'building will be inspected for - compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. OWNER/ T BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. NEW s - Compliance requires an Air Barrier and Insulation Inspection. Checklist in accordance rt an hEQdrRct requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 . 0 . � �-COMPLIAN , ST. L CIE COUNTY L Ur DCC 4/21/2020 10:04 AM EnergyGauge®USA 6.0.02.(Rev:1) - FlaRes2017 FBC 6th Edition (2017). CompliantSoftware Page 1 of 6 FORM R405-2017 INPUT 5UMMAKY. UHEUKLIST KEPOKT PROJECT Title: WYNNE THE WINDSOR IMP Bedrooms: 3 Address Type: StreetAddress Building Type: User ConditionedArea: 1753 Lot# OwnerName: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: BuilderName: WYNNE DEVELOPMENT RotateAngle: 0. Street: Permit Office:. ST. LUCIE COUNTY CrossVentilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE., FamilyType: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE ; / Design Temp Int Design Temp Heating Design DailyTemp V Design Location TMY Site 97.5 % 2.5 % Winter Summer DegreeDays Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI. 39 90 70 75 299 62 tow BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES Number Name' Area Volume Kitchen Occupants :Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDR00 224 1792 No .0 1 1 Yes Yes Yes 2 WIC 63 504 ,. -No 0 1 No Yes Yes. 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M.BATH 61 488 No 0 1 Yes Yes Yes . 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0, 1 1 Yes Yes Yes 7 DINING/GREAT RO 588 4704 No .2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes . 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # FloorType Space Perimeter PerimeterR-Value Area- Joist R-Value Tile . Wood Carpet 1 Slab -On -Grade Edge lnsulation MASTER BEDRO 37 ft 0 224 ft2 _--_ 0 1 0 2Slab-On-Grade Edge Insulation WIC 1-ft 0 63ft2 --__ 0 1 0 3 Slab -On -Grade Edge Insulation I MASTER BATH 8 ft 0 56 ft2 _--- 0 1 0 4Slab-On-Grade Edge lnsulation M. BATH 7 ft 0 61 ft2 _ __ 0 1 0 5Slab-On-Grade Edge Insulation LAUDRY 1 ft 0 36ft2 0 1 0 4/21 /2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th.-Edition:(2017) Compliant Software ' I Page 2 of 6. FORM R405-2017 . INPUT. SUMMARY CHECKLIST REPf)RT FLOORS # FloorType Space Perimeter PerimeterR-Value (Area JoistR-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulation BEDROOM 2 12 ft 0 180 ft2 ____ 0 1 0 7Slab-On-Grade Edge Insulation DINING/GREAT 50ft 0 588 ft2 ____ 0 1 0 8Slab-On-Grade Edge insulation KITCHEN lift 0 209ft2 ____ 0 1 0 9Slab-On-Grade Edge Insulation BATH 5ft 0 ;50ft? ____ 0 1 0 10SIab-On-Grade Edge Insulation HALL 11ft 0 25ft2 0 1 0 11Slab-On-Grade Edge Insulation FOYER 9 ft 0 92 ft2 0 1 0 12SIab-On-Grade Edgelnsulation BEDROOM 3 14 ft 0 169 ft2 ____ 0 1 0 ROOF / Roof Gable. Roof I Red* Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color ;Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1847 ft2 0 ft2 Light N 0.4 No 0.9 . No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 175.3 ft2 I N N CEILING # Ceiling Type Space R-Value Ins Type,! Area Framing Frac Truss Type, 1 UnderAttic(Vented) MASTER BEDRO 30 Blown 224 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 6312 0.1 Wood 3 UnderAttic (Vented) MASTER BATH 30 Blown 5612 0.1 Wood 4 Under Attic (Vented) M. BATH • 30 Blown 61 W 0.1 Wood 5 UnderAttic(Vented) LAUDRY 30 Blown 36ft2 0.1 Wood 6 UnderAttic(Vented) BEDROOM 30 Blown 180ft2 0.1 Wood 7 Under Attic (Vented) DINING/GREAT 30 Blown i 588 ft2 0.1 Wood 81 UnderAttic(Vented) KITCHEN 30 Blown 209ft2 0.1 Wood 9 Under Attic (Vented) BATH 30 Blown 50ft2 0.1 Wood 10 UnderAttic(Vented) HALL 30 Blown 25ft2 0.1 Wood 11 UnderAttic(Vented)' FOYER 30 Blown 92ft2 0.1 Wood 12 UnderAttic (Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood 13 Knee wall (Vented) DINING/GREAT 19 Blown i 30 ft2 0.11 Wood WALLS Adjacent Space Cavity .Width Height Sheathing' Framing Solar Below 0 1 E Exterior Concrete Block- Int InsuMASTER BE 4.1 16 0 8 10 128.0 ft2 0 0 6.3 0 2 W Exterior Concrete Block- Int InsuMASTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 _ 3 S Exterior Concrete Block - Int InsuMASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.3 0 4/21/2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1.) - FlaRes2017FBC 6th Edition:(2017). Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY r..I-IFE'_KI IST RFPIIRT WALLS Adjacent Space.R-1/alue Cavity Width Et In ' Height Ft In Area Sheathing Framing R-4Lghle Fraction Solar Below Absor 0 4 E Exterior Concrete Block - Int InsuMASTER BA 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 5 E Exterior Concrete Block- Int Insul M. BATH 4.1 7 0 8 0 56.0 ft2 0 0 0.3. 0 6 E Exterior Concrete Block- Int InsuBEDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.3 0 _ 7 S Exterior Concrete.Block- IntlnsuDINING/GRE 4:1 30 0 8 0 240.0ft2 0 0 0.3 0 8 W Exterior Concrete'Block- Int InsuDINING/GRE 4.1 20 0. 8 0 160.0 ft2 0 0 0.3 0 9 W Exterior Concrete Block- Int Insul KITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.3 0 10 E Exterior Concrete Block- Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.3 0 11 N Exterior Concrete Block- Int Insul FOYER 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 12 N Exterior Concrete Block- Int Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 _ 13 W Exterior Concrete Block- Int InsuBEDROOM 3 4.1 . 13 0 8 0 104.0 ft2 0 0 0.3 0 14 N Exterior Concrete Block- Int InsuBEDROOM 3 461 1 0 8 0 8.0 ft2 0 0 0.3 0 _15 N Garage Frame -Wood. BEDROOM 11 26 8 208.0ft2 0.23 0.3 0 DOORS # Ornt DoorType Space Storms Y U-Value Width Height Area Ft In Ft In 1 N Insulated FOYER None .32 3 3 6 8 21.7 ft2 WINDOWS Orientation shown is the entered orientation => chancedi to Worst Case. / Wall Overhang V # Ornt. ID Frame Panes NFRC U-Factor SHGC Imp ;Area Depth Separation IntShade Screening 1 S 3 Metal Low-ESingle Yes 1.04 0.29 N 32.4ft' 1 ft 0 in 1 ft 5 in Drapes/blinds Exteriors 2 E 5 Metal Low-ESingle Yes 1.04 0.29 N 6.9 ft2 1 ft 0 in 1 ft 5 in None None 3 E 6 Metal Low-ESingle Yes 1.04 0.29 N 1 16.2 ft2 1 ft 0 in 1 ft 5 in None None 4 S 7 Metal Low-ESingle. Yes 1.04 0.29 N 3'9.8 ft2 1 ft 0 in 1 ft 5 in None None 5 W 8 Metal Low-ESingle Yes 1.11 0.27 N 4.0.0 ft2 8 ft 0 in 1 ft 5 in None None 6 W 13 Metal Low-ESingle Yes 1.04 0.29 N 16.2 ft2 1 ft 0 in 1 ft 5 in Drapes/blinds Exterior5 GARAGE # FloorArea CeilingArea Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 806 ft2 806 ft2 26 ft 8 ft 11 INFILTRATION ' # Scope Method SLA CFM 50 ELA Egl-A� ACH ACH 50 1 Wholehouse ProposedACH(50) .000254 1168.7 64.16 120.66 .0881 5 4/21/2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Ediuon:(2017). Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY. CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency ' Capacity Block Ducts 1 ElectricHeatPump/ Split Single HSPF:8.5 34.8 kBtu/hr 1 sys#1. COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 CentralUnitt Split Single SEER:15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # . System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 50 gal 60.6 gal 120 deg None SOLAR HOT WATER SYSTEM i FSEC • Collector Storage Cert # CompanyName. System Model# Colle6torModel# Area Volume FEF None None ft2 DUCTS / -- Supply— ---- Return ----Air, CFM 25 CFM25 HVAC # # Location R-Value Area Location Area LeakageType Handler TOT OUT, QN RLF Heat Cool 1 Attic 6 175 ft2 Attic .55 ft2 DefaultLeakage ; Attic. (Default) c(Default) c "TEMPERATURES ProgramableThermostat: Y Ceiling Fans: Cooling Jan Feb Mar Jan Feb Mar Apr f Apr f Ma Jun Jul Au May Jun Jul Aug Se Sep Oct .Nov f Oct f X)j Nov Dec Dec Venting Ventin Jan Feb Mar [X] Apr [ May Jun Jul Au f Se [X] Oct [X] Nov Dec ThermostatSchedule: HERS 2006 Reference Hours. Schedule Type .1 2 3 4 5 6 : 7 8 9' 10 11 12 Cooling (WD) AM 78 PM 80 78 78 80 78 78 78 78 .78 78 78 i78 78 80 80 80 80 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 18 78 78 78 78 78 PM 78 78 78 78 .78 78 178 78 78 78_ 78 78 Heating (WD) AM 66 PM 68 66 66 68 68 66 66 68 168 68 68 68 68 68 68 68 68, 168. 68 68 68 66 66 Heating(WEH) AM .66 PM 68 66 66 66 66 68 '68 68 68 .68 68 68 68 68 68 68 68 B 68 68 68 66 66 . MASS' G. Mass Type Area Thickness FumitureFraction Space Default(8lbs/sq.ft. 0 ft2 Oft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft2 ft 0.3 'WIC Default(8lbs/sq.ft. ft2 ft 0.3 MASTER BATH Default(8lbs/sq.ft. ft2 ft 0.3 M. BATH Default(81bs/sq.ft• ft2 ft 0.3 LAUDRY Default(81bs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(81bs/sq.ft. ft2 ft 0:3 DINING/GREAT RO Default(8lbs/sq.ft. ft2 ft 0.3 KITCHEN 4/21/2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes= 7 FBC 6th Edition (2017), Compliant Software Page 5. of 6 FORM R405-2017 INPUT. SUMMARY: CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 ibs/sq.ft. Default(8lbs/sq.ft. Default(8 Ibs/sq.ft. Default(8 lbs/s.ft. ftz ft 0.3 ftz ft 0.3 ftz ft 0.3 ftz ft 0.3 BATH HALL FOYER BEDROOM 3 i 4/21/2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 2017 -AIR. BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER.AND INSULATION.INSPECTION.COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR.IMPACT Builder Name: WYNNE DEVELOPMENT Street: Permit Office:, ST..LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, • Permit Number:. X Ownerr. ." Jurisdiction:1 tau Design Location: FL, Fort Pierce j y COMPONENT AIR BARRIER CRITERIA INSULATION.INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope.. 'Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. i not. be used as a sealing material. Breaks or joints in the air barrier shall. be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit. shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to' .' unconditioned attic spaces shall be sealed: Wails The junction of the foundation and sill plate shall be sealed. i Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity . sealed. i with a material having a thermal resistance of R-3 Knee walls shall be sealed. ! per inch minimum. Exterior thermal envelopeinsulation for framed I walls. shall be installed in substantial contact and I continuous alignment with. the air barrier: ,Windows.; skylights The space. between window/doorjambs and framing, and j and doors skylights andframing'shall be sealed. Rim joists Rim joists shall include the air barrier. Rim`joists shall be insulated., Floors The air barrier shall -be installed at any exposed edge of Floor framing cavity insulation shall be"installed to (including insulation. • maintain permanent contact with the underside of above -garage subfloor decking,or floor framing cavity g insulation and cantilevered shall be permitted to be in- contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from.the bottom to the:top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. ' shall be permanently attached to the crawispace Shafts,: penetrations Duct shafts, utility penetrations, and flue shafts opening tq exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation'readily conforms to the available cavity spaces. Garage separation Airsealingshall be provided between the garage -and conditioned spac 3s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall, thermal envelope shall be air tight'and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation4hat on installation readily conforms to available space shall i�ytPnri-hPbiagLp9pino and wiring Shower/tub The air barrier installed at exterior walls adjacent to, showers and Exterior walls_ adjacenfto showers and tubs shall. on. exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical'or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall i .be sealed to the sub -floor or drywall. Concealed When required -to be sealed, concealed fire sprinklers shall only be j sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire spr nkler cover pIRte_Q and walls or ceilings - a. in audition, inspecuon.vi iog walls snap ve in accordancewitn Ine.provisions of ICU-4U0: j - 4/21/2020 10:05 AM Ene'rgyGaugeO USA 6.0.02 (Rev. 1) - Fla'Res2017 FBC 6th Edition (2017) Compliant. Software Page 1. of 1 2017 EPL DISPLAY CARD ENE'RGY..PERFORMANCE LE.VEL(EPL).DISPLAY:CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The .lower the Energy Performance Index, the.more efficient the home. i 1. New home or, addition. 1. New (From Plans) 12. Ducts, location.& insulation level a). Supply ducts R 6.0 . 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3.,No. of units (if multiple -family) 3. 1 l i 4. Number of bedrooms - 5. Is this a worst. case? (yes/no) 6. Conditioned floor area (sq. ft.) 4. 3 13. 5. Yes 6. 1753 7. Windows, type and area a) U-factor:(weighted average). 7a. 1.058 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.285 14. c) Area 7c. 15.1.4 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b.. NA 9. Floor type, insulation level: a) Slab-on=grade*(R-value) b) Wood,. raised (R-value) c) Concrete, raised (R-value) 1.0. Wall type and insulation: A. Exterior. 1. Wood frame (Insulation R-value) 2: Masonry (insulation R-value) B. Adjacent: 1:..Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type.and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 :a). b) c) d) e). a) b) c) d) e) f)1 9b. 15. W 9c. a) b). c) d) 10A1. e) 10A2. 4.1 f) g) 1061. 11.0. 10132. 16. H\ a) 11 a. 30.0. b). 11_b. c)' 11c. 19.0 d) 11 d. No e) f) I *Label required:by Section R303.1-.3 of the Florida Building Code, Energy Cons I certify that this home has complied with the Florida Building Code, Energy Co saving,feature6 which will be installed (or exceeded) -in this home before final it display card will.be completed based on installed code compliant .features. Builder Signature: - Date: Address of New. Home �� �C . City/FL � 'system: Capacity 34.8 system. SEER 15.0 epackage . SEER nd/water source. SEERICOP n unit/PTACEER g system:. Capacity 34.8 t system heat pump HSPF .8.5 Ile ;package heat pump. HSPF ,tric resistance. - COP furnace, natural gas AFUE furnace,, LPG. AFUE - !r heating system tric.resistance ' EF 0.97 :fired, natural gas EF fired, LPG EF r system with tank EF Gated heat pump with.tank EF . recovery unit HeatRec% credits claimed (Performance Method) ng fans ;s ventilation No le.house fan -No izone cooling credit izone heating credit. rammable, thermostat Yes if not DEFAULT. I, through the above energy Otherwise, a new EPL FT. PIERCE. FL%- . `� S 4/21/2020 10:05:25 AM Ener Gau e® USA 6:0.04. Rev. 1 9y g ( ) - FlaRes2017 FBC I6th Edition (2017) Compliant Software Page 1 of 1