Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Truss
A=LIFE SAFETY WARNING This symbol identifies Life Safety Warnings that should be read given special attention by all persons installing trusses. 5PAGING NOTE I I I The Architect's or Architect's representative's 1- R THE FIRS] MODEL SHOULD BE SHIPPED AND SUCCESSFULLY SET BEFORE E TRUSSES "shop double check" of the cis HOTa TRUSS_S 0 OD ED E ANY MORE ARE BUILT FOR TEAT MODEL_. L Thecontractorshall remain responsible ARRANJE WITH CRANE OPERATOR IN ADVANCE FOR A SPREADER BAR OF 18' - 24' IN LENGTH '- -- for checking field measia. ,ctsand A other construction criteria. Architect's I approval covers general roof shape, a a I review of truss strapping, and loading on Do not .tand on trusses unti they are braced per BCSI & properly nailed to straps & hangers v struo4urefromeirre vitye locaiif�loads and I/ � their rep five loetati ns. I V(,Approved S ZIo 15C G '-3" --- — -- 19'-9" 1g�_ ,_ ,r I L Date:. 15 3 , : Braden &.. Braden A.I.A. 9 A. ALI .TRUSSES ARE TO BE SET AT 2'-O' ON CENTER. — EXCEPT AS NOTED J1 MULTIPLE PLY TRUSSES MUST BE J3 ASTENED TOGETHER PER ENGINEERINGJ3 1" BEFORE SETTING. REFER TO J5 0 0 J5 ENGINEERING DRAWING TO DETERMINE , 11< AL IF MULTIPLE PLY. AlBRA DON'T LIFT TRUSSES At 1 r WITH SPANS LONGER THAN 1 1 30' BY THE PEAK. A2 1 CONSULT BCSI I1 30' Spanlor less A 30' to 60' Span r A3 �50 degrees Spreader Bar J. \or less 44 - y 2 —� ag �_APProx 213 to__� AS T0C3 rle spoon opproX Line-1 /2 of Span a REFER TO BCSI REFER TO BCSI Truss must be. set thisway if crone used,Tress must be set this way if crone used, Truss is an example your tress may not mct.h. This is on example truss may not match.. Insist croneoperatorsets truss this way.- Insist crone operator sets trussthis way. I All load bearing walls, headers, beams & lintels must be in place at indicated height before trusses ® are installed. ,411 FR " 4l " I F= FR " it _T_ IFE UNLESS NOTED ELSEWHERE ON THIS LAYOUT, THESE TRUSSES ARE NOT DESIGNED FOR AIR HANDLERS IN THE ROOF OR FOR ANY OTHER A/C REQUIREMENTS. THIS MAY BE IN CONFLICT WITH BUILDING CODE AND A/C DESIGN REQUIREMENTS. CONSULT WITH BUILDING DEPARTMENT AND A/C CONTRACTOR. Carrying Girder For Truss to Truss Connections see hanger/connector Nails must be as shown. Guide tabs o schedule in engineering Dome angle nails. package. Carried Truss - SEAT PLATES BY CHAMBERS u a cnu" c" loarrep As tsNe NSIa"sD an u.our to ON112"axs uT's'„12 CORNER DETAIL 4.00 — OVERFI NOT SHOWN FOR CLARITY - �o 8 M 1' upset=1/4" heel=315/16" PLUMB CUT END 2 x 4 Top Chord WALL HEIGHT 8' TYPICAL END DETAIL 12 4.00 I i.0 ,?81 � 12 2,00 $-- M A5 i A5 1 � ,\ 1 0 I I 15 14'_9a 13e -2 1 �s I 1 h 1 2. 21 /12 r � � 1 N. k5 1 05 1 k 1 15 t5 1 tT T INVERTED "V" WEBS AT CENTER o W/9' B.C. PANNEL. LOAD W/ (2) r 50# POINT LOADS PER TRUSS FOR A/H/U tT r Ih tT 7' RFTFl Rr)CTOKI HIP O BHA oT x upset=1/4" heel=315/16" INDICATES LOAD BEARING PLUMB CUT END REQUIRED BY TRUSSES SUPPLIED BY BUILDER 2 x 4 Top Chord AT A HEIGHT OF 8'-0" WALL HEIGHT 8' ABOVE FINISHED FLOOR END DETAIL: TYPICAL VAULT • • J I � ' RIGHT J5 J3 it n mSill \�� I II 1►iRi� 11 Ij I 1 it �. II MIMI Im! INS ,`11j' IIII Miss — Iwo, INV ®_ �' INVERTED nr WEBS AT CENTER 50# POINT LOADS LIFERTRUSS FOR All SMINEWIl BHI �,►\\�\\��\I\\\\\\I r `\�i\\\`I\\\`\\I\� i�i�7�\\I��la►\H�11�1 i 1 I I I�\I ®I®ImI®IMI®1�81®I■11�18�1®IL�i®�®� I®I i� CLOU� ED AREAS ARE OF / SPECIAL CONCERN & MUST BE 1 CHECKED CAREFULLY '& MAY i t INDICATE DEVIATION FROM PLANS.„ FABRICATION AGREEMENT —� TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS The legal description of the property where the trusses will be Installed is: giONED 8 RETURNED The underslgnetl acknowledges and agrees: 1: Trussea will be made In strict accordance with this truss placement diagram layout, I which Is the sole authority for determining. successful fabrication of the trusses, 2. All dimensions In this layout have bean verified by the undersigned, 3. en notice Is provid days bf'delheryess dthe undersigned Ogr Ogress met no ackcharges MIto b a INas within ten (10) such wdnen notice is fvmished Chambers Trues shall have three (3) bu rasa da slowed. In the event to begin repalre required, or to aubeUMe other W saes, at Chamars o--i @j ya in which 5. Delivery is undersigned tto job te�lt Is�he buyere�reepCon1 b ry to make the lob alto suitable Ator delhrery. Chambers Truss has the sole authority to determina the sultablltty of the Job site o'r a potion of the Job she for delivery. Chsmbers Trvsa will ba responsible for dump delivery only. (BuyeThe buyer la responsible for addklonel deliver;. expenses U Chambers Trues has to redelher , beeauea Job ette la not prepared for delivery or buyer le not prepared for delivery of trusses, r Is responsible to Chambers Truss for towing costa duo to efts condr dellong. 8, Price es shown Iq paragraph 7 slow le cubJed to change a any changes are, made m this. layout. A $50 per hour fee for reNsl )no may be charged by Chamber; TNsa. 7: This is a PURCHASE ORDER to Chambers, Truss of the aum agreed to, or B ne:. agreement a reasonable price, invoice will be made on delivery and paid within terms of ne ,On dalMery. Invoice may be made at scheduled date bf delivery If buyer cannot accepC L delivery of fabricated trusses. The undersigned agrees to pay Chambera.7Nes reasonable charge 's fee for collectkna In event of payment not timely made, 1-12 °h, per month service ! charge will be added for all sums not paldwithin terms, i S. Signature or Initials anywhere on this sheet constitutes agreement to all terms herein. conaldereNO of Chambers Truss extending trade for this material the undersigned i uncondlgonally guarent lea payment when due of any and all Indebtedness owatl to Chembere Truss to any entity receiving material and the undersigned agrees to pay such " Indebtedness IIn uding ettomay, fees, U default in payment for ineddal agree made by the reciplent. or 10. In the event of any 11119 ion conceming this agreement, Na Xema famished hereunder be Sal t l:uole Counryt Flprido. to parties agree that the We venue for any such action will it. Design rea onslbliNss are per-Nagonel Standard And Rdbbmmended Guidelines On I Rasp onsibjilt ea For On' On Using Metal Plate Connected AWood Trusses NSIRPVWTCA4-2DD2" DATED SIGNED `'Ilk FOR TITLE r+UtP,eroarmayba.'1C per"BCSI 1-08"tppreverltlnjuy$ � Multiple ply trusses must be fastened together per engineering before they are set; failure to do so can result In roof collapse. Temporary and permanent bracing are required and can save life and property and Is the responsibility of the truss erector, Study the contents of the Information packet Included on delivery before setting trusses. Trusseemustbesetandbrawdpe�deslgnto ,tlnfuryL damage Trusses must beset plumb and square Do not set bunks or stack of plywood, roofing material or any _other cdncentrated loads on trusses, this can cause collapse. DON TSET TRUSSES USING THIS L4yoUT USE LAYOUT DELIVERED WITH TRUSSES TO 3ET TRUSSES 3105 Oleander Avenue Fort Piercei Florida 34982-6423 800�51-5932 Fort Plerce 772.465.2012 Fax 771-465.8711 Vero Beach 772-569-2012 Stuart 772-2863302 `All eu.,, ruaueeeet'oftcs 92 0/93.2 MITEK 4.2 DESIGN CRITERIA County SAINT LUCIE Building Department ST LUCIE COUNTY Wind Design Criteria ASCE 7-2010 Wind Design Method MWFRS/C-C hybrid Wind ASCE 7-10 3 . Roclfing Material Shingle or Shake o v s% Loading in PSF Roof R.D.L. `—° = � — Top Chord Live 20 w C Top Chord Dead 7 4.2 " r Bottom Chord Live 10 Non -Concurrent o a Bottom Chord Dead 10 3 TOTAL Load 37 7.2 M o' Duration Factor 1.25 Wind Speed 165mph rn Top Chord C.B. Sheeting by builder. w Bottom Chord C.B. Sheeting by builder. Highest Mean Height 15'-0" Building Type ENCLOSED Building Category II:Non Restrictive Exposure Category C Barrier Island No i Conforms to FBC 2017 M.0I_.=riiestralninq Uead Load C.B.=Continuous Bracin Verify DESIGN CRITERIA shown above with the building department and your engineer. Design Criteria is the responsibility of the Building Designer and/or En ineer of Record. LLChambers Truss Inc. Drawing Name: M11392 Scale: 1 /4 = 1' W 82 total trusses, 15 different trusses. MI 4: RLC ACAD: RLC Reviewed By: Date: 10/07/15 1 3/21 /18 _ FC►REVfEW 3/05/2020 l mil" 6,�" CODE COMPL► --- -- - --- 14'° W Y N N E < sw PORCH LEFT DESCRIPTIOt�OCC WINDSOR PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE 15 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT M 11392;, sf ��e5 MiTek" RE: M 11392 THE WINDSOR Site Information: Customer: Wynne Dev Corp Project Name: M11392 Lot/Block: Model: THE WINDSOR Address: unknown City: St. Lucie County Subdivision: State: FL MiTek USA, Inc. 6904 Parke East Blvd. Tampa, FL 33610-4115 General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): . Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.1 Wind Code: ASCE 7-10 Wind Speed: 165 mph Roof Load: 37.0 psf Floor Load: N/A psf This package includes 15 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# Truss Name Date 1 T19781803 A 4/22/2020 2 T19781804 Al 4/22/2020 t 3 T19781805 A2 4/22/2020 4 T19781806 A3 4/22/2020 5 T19781807 A4 4/22/2020 6 T19781809 A5 4/22/2020 REVIEWED FOR 7 T19781809 ATA 4/22/2020 REVIEWED 6�'1'i 8 T19781810 B 4/22/2020 CODE COMPLIANCE 9 T19781811 BHA 4/22/2020 COMPLIANCE V 10 T19781812 GRA 4/22/2020 ST. LUCIE COUNTY 11 T19781813 J1 4/22/2020 '�! 12 T19781814 J3 4/22/2020 E®CC 13 T19781815 J5 4/22/2020 14 T19781816 J7 4/22/2020 15 T19781817 KJ7 4/22/2020 This item has been electronically signed and sealed by Albani, Thomas using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies The truss drawing(s) referenced above have been prepared by MiTek USA, Inc under my direct supervision ,,01%J1 t t 111111 based on the parameters provided by Chambers Truss. ��O�PS„�•� • q�e �i,� Truss Design Engineer's Name: Alban!, Thomas �� �. •• C, E NS ••,;� �i� My license renewal date for the state of Florida is February 28, 2021. •'•�� F L� Florida COA: 6634 No 39380 IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurlsdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. sk — 0. STATE OF :�44/ Z. O R ` Q P Nam,. ys`4/ONA`''- � Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 April 22, 2020 1 of 1 Albani, Thomas Job Truss Truss Type Qty Ply THE WINDSOR T19781803 M11392 A HIP 1 1 Job Reference (optional) unamoers i cuss, Inc., ron vierce, rL o.L4U s rvlar a Lulu ivu I ex Inciusines, Inc. I ue mar L4 7L:.74:ur Lulu rage i ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-KTRK2jb7uXlhmgejamLw33G2phzq_UFBTsBBV6zXjH_ �1-0-0 6-10-14 9-0-0 14-11-0 20-2-13 26-0-0 28-1-2 35-0-0 36-0-q -0-0 6-10-14 2-1-2 5-11-0 5-3-13 5-9-3 2A 6-10-14 -0-0 �1 d 4.00 12 4x8 = 2x3 II 2x3 4 26 5 3x6 = 4x4 = 4x8 — 2x3 6 7 27 8 9 Scale = 1:60.5 17 16 15 14 13 12 3x4 — 3x4 = 3x6 — 6x8 = 3x4 = 3x6 — 3x4 = 3x5 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udefl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.57 Vert(LL) 0.42 12-23 >572 240 TCDL 7.0 Lumber DOL 1.25 BC 0.47 Vert(CT) 0.37 12-23 >659 180 BCLL 0.0 Rep Stress Incr YES WB 0.94 Horz(CT) 0.03 10 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD BOT CHORD 2x4 SP M 30 BOT CHORD WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 15=0-8-0, 10=0-8-0 Max Horz 2=-97(LC 10) Max Uplift 2=-235(LC 12), 15=-1439(LC 12), 10=-799(LC 12) Max Grav 2=467(LC 17),15=1596(LC 1),10=685(LC 22) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-639/108, 3-4=-396/0, 4-5=-967/776, 5-7=-967/776, 7-8=-454/938, 8-9=-1009/1884, 9-10=-1265/2154 BOT CHORD 2-17=0/652,15-17=0/430,14-15=-704/454,12-14=-1586/938,10-12=-1971/1174 WEBS 3-17=-372/461, 4-17=-272/451, 4-1 5=1 08711002, 5-15=336/386, 7-14=-766/399, 8-14=-580/997, 8-12=-958/447, 9-12=-358/600, 7-15=-1329/2190 PLATES GRIP MT20 244/190 Weight: 161 lb FT = 20% Structural wood sheathing directly applied or 6-0-0 oc purlins. Rigid ceiling directly applied or 4-5-1 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf, BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 9-0-0, Exterior(2) 9-0-0 to 13-11-6, Interior(1) 13-11-6 to 26-0-0, Exterior(2) 26-0-0 to 30-11-6, Interior(1) 30-11-6 to 36-0-0 zone; porch right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 235 lb uplift at joint 2, 1439 lb uplift at joint 15 and 799 lb uplift at joint 10. A c%r 1 � IA 6 This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 AWARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MiTEK REFERENCE PAGE 111II.7473 rev. 10/03/2015 BEFORE USE. -- Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall V building design. Bracing Indicated is to prevent buckling of individual buss web and/or chord members only. Additional temporary and permanent bracing °' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the piTe k• fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP/f Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type city Ply THE WINDSOR T19781804 M11392 Al SPECIAL 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:08 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-of7iF3blfgtYOgDv7Us9cGoCh5CAjz5K!VwkOzzXjGz �1-0-0, 8-0-0 11-0-0 14-9-0 19-8-14 24-0-0 27-0-7 35 0.0 $6.0-q -0-0 8-6-0 2-6-0 3-9-0 4-11-14 4-3-2 3-0-7 7-7-9 -0-0 Scale=1:61.3 5x6 2x3 11 5x8 MT18HS = = 4.00 12 3x4 4 - 21 5 6 22 7 C1 3x6 = 13 12 3x5 = 5x8 MT18HS = 2.00 12 3x12 10-0-0 14-9-0 24-6-8 35-M ' 10-M 4-9-0 9-9-8 10-5-8 Plate Offsets (X,Y)— [2:0-0-2,Edge), [7:0-4-0,0-2-3), [9:0-1-15,Edge) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TOLL 20.0 Plate Grip DOL 1.25 TC 0.63 Vert(LL) 0.75 11-12 >563 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.91 Vert(CT) -1.21 11-12 >348 180 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.77 Horz(CT) 0.35 9 n/a n/a BCDL 10.0 Code FBC2017ITP12014 Matrix -MS Weight: 155 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-7-7 cc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 cc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=-117(LC 10) Max Uplift 2=-825(LC 12), 9=-825(LC 12) Max Grav 2=1349(LC 1). 9=1349(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3209/2102, 3-4=-3006/2024, 4-5=-3022/2080, 5-6=-3022/2080, 6-7=-4643/2994, 7-8=-5324/3364, 8-9=-5751/3700 BOT CHORD 2-13=-1883/3007, 12-13=-1591/2657, 11-12=-2456/3908, 9-11=-3442/5478 WEBS 3-13=425/410, 4-13=354/571, 4-12=-362/617, 5-12=-269/279, 6-12=-1034/712, 6-11=-373/892, 7-11=-897/1523, 8-11=-404/435 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 This item 3) Provide adequate drainage to prevent water ponding. has been 4) All plates are MT20 plates unless otherwise indicated. electronically Signed and 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. sealed by Albani, Thomas, PE 6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide using a Digital Signature. will fit between the bottom chord and any other members. 7) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify Printed copies of this capacity of bearing surface. document are not Considered 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at signed and sealed and the joint 9. signature must be verified on any electronic copies. Thomas A. Alban! PE No.39380 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. ' Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall q building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPH Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type 0ty Ply THE WINDSOR T19781805 M11392 A2 SPECIAL 1 1 Job Reference o tional Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:09 2020 Page 1 ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-HSZ4SPC008?P?zo5hBO08ULMuVYnSPxUx9glY?zXjGy 1-0-0 B-6-0 1311 14-91 22-0-0 271 -7 35-0-0 6-0- -0-0 8-6-0 4-6-0 1-9-0 7-3-0 5-4-7 7-7-9 -0-0 5x6 = 3x4 = 5x8 = 4.00 12 4 21 5 22 6 3x4 = 3x6 = 12 5x8 = 2.00 12 35-0-0 302 Scale=1:61.3 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udefl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.66 Vert(LL) 0.72 10 >585 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.95 Vert(CT) -0.94 10-19 >447 180 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.86 Horz(CT) 0.34 8 n/a We BCDL 10.0 Code FBC20171TP12014 Matrix -MS Weight: 160 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-6-15 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 8=0-8-0 Max Horz 2=136(LC 11) Max Uplift 2=-825(LC 12), 8=-825(LC 12) Max Grav 2=1349(LC 1), 8=1349(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3211/2064, 3-4=-3017/1998, 4-5=-2580/1800, 5-6=-3379/2225, 6-7=-5242/3250, 7-8=-5759/3665 BOT CHORD 2-13=-1847/3008, 12-13=-1403/2418, 11-12=-1552/2629, 10-11=1990/3441, 8-10=-3410/5485 WEBS 3-13=-420/418, 4-13=-427/688, 4-12=-337/551, 5-12=-777/605, 5-11=-465/925, 6-11=-391/277,6-10=-1318/2268,7-10=503/530 - NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at joint 8. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mlr-7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall p p� building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing 1 VI iTek- is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTP/1 quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply THE WINDSOR T19781806 M11392 A3 SPECIAL 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:10 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-127SgidOBS7Gd7NIFvvehhuYXvu2Bsnd9pPr4RzXjGx �1-0-0 8-6-0 15-0-0 20-0-0 246-8 27-4-7 35-0-0 $6-0-0, i-0-0' 8-6-0 6 6-0 5 0-0 4-6 8 2-9-15 7-7-9 -0-0 4.00 12 5x6 = 4x5 = 14 13 "'" 3x5 = 2x3 II LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2017/TPI2014 LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Harz 2=-155(LC 10) Max Uplift 2=-825(LC 12), 9=-825(LC 12) Max Grav 2=1349(LC 1), 9=1349(LC 1) 5x6 = 2.00 12 24-8-8 Scale = 1:62.3 3x12 ZZ CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TC 0.60 Vert(LL) 0.73 11 >572 240 MT20 244/190 BC 0.95 Vert(CT)-0.9711-20 >432 180 MT18HS 244/190 WB 0.83 Horz(CT) 0.36 9 n/a n/a Matrix -MS Weight: 160 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-6-15 oc purlins. BOT CHORD Rigid ceiling direc0y applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 7-12 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-3256/2031, 4-5=-2426/1588, 5-6=-2680/1790, 6-7=-2829/1832, 7-8=-5320/3257, 8-9=-5720/3554 BOT CHORD 2-14=-1817/3048, 13-14=-1817/3048, 12-13=-1258/2274, 11-12=2935/5103, 9-11=-3302/5445 WEBS 4-14=0/329, 4-13=-897/636, 5-12=-316/661, 6-12=-317/616, 7-12=-2727/1643, 7-11 =1 072/1939, 8-11=-390/391 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf, h=15ft; B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at joint 9. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33810 Date: March 24,2020 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall r building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• I always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPl1 Quality Criteria, OSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply THE WINDSOR T19781807 M11392 A4 SPECIAL 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:11 2020 Page 1 ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-DEhgt5eexIF7FHyUpcQtEvaj7l DGwGhnOT90duzxjGw 1-0-0 8-6-0 14-9-0 17-0-0 18-0-q 24 6-8 27-4-7 35-0-0 a6-0-0 i-0-0 8.6-0 6-3-0 23-0 -0-0 6-6-8 2-9-15 7-7-9 -0-0 Scale = 1:62.3 3x5 = 4.00 12 5x6 = 4x6 = 20 11 6 7 16 15 6x10 = 2x3 11 5x8 = LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.59 TCDL 7.0 Lumber DOL 1.25 BC 0.95 BCLL 0.0 Rep Stress Incr YES WS 0.98 BCDL 10.0 Code FBC20171TPI2014 Matrix -MS LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 11=0-8-0 Max Horz 2=-175(LC 10) Max Uplift 2=-825(LC 12), 11=-825(LC 12) Max Grav 2=1349(LC 1), 11=1349(LC 1) 3x12 zz 2.00 12 DEFL. in (loc) Udefl L/d PLATES GRIP Vert(LL) 0.80 13 >528 240 MT20 244/190 Vert(CT) -1.05 13 >400 180 MT18HS 244/190 Horz(CT) 0.39 ' 11 n/a n/a Weight: 172 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-6-14 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 8-14 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3253/1989, 3-5=-2435/1560, 5-6=-2399/1639, 6-7=2217/1501, 7-8=-2380/1519, 8-10=-5361/3228, 10-11=-5716/3480 BOT CHORD 2-16=-1776/3045, 15-16=-1776/3045, 14-15=-1117/2168, 13-14=-2920/5154, 11-13=-3232/5441 WEBS 3-16=0/334, 3-15=-882/614, 5-15=-238/254, 7-14=-1631427, 6-14=-309/604, 6-15=-315/409, 8-14=-3146/1901,8-13=-1034/1946,10-13=-343/333 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf, BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(?) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide Will fit between the bottom chord and any other members. 7) Bearing at joint(s) 11 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at joint 11. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Alban! PE No.39380 MiTek USA, Inc. FL Cart 6834 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. f0103/2015 BEFORE USE, Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall MiTek' building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing iVliTek' I always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS!/TP/f Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria„VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply THEWINDSOR T19781808 M11392 A5 SPECIAL 16 1 Job Reference o tional Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:13 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-9dpbinfuTNVrUb6tw1 SLJKWOV6vFOEp3meVhmzXjGu �1-0-0, 8-6-0 14-9-0 17-6-0 24-6-8 27-0-7 35-M -0-0 8-6-0 6-3-0 2-9-0 7-0-8 2-9-15 7-7-9 -0-0 3x5 = 5x8 MT18HS 11 4.00 12 14 13 2x3 11 5x10 = 2.00 12 LOADING (psi) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.81 TCDL 7.0 Lumber DOL 1.25 BC 0.92 BCLL 0.0 Rep Stress Incr YES WB 0.74 BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS LUMBER - TOP CHORD 2x4 SP M 31 'Except 1-4,8-11: 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 *Except* 6-12: 2x4 SP M 30 OTHERS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 10=0-8-0 Max Horz 2=-179(LC 10) Max Uplift 2=-825(LC 12), 10=-825(LC 12) Max Grav 2=1349(LC 1), 10=1349(LC 1) DEFL. in (loc) Vdefl L/d Vert(LL) 0.80 12-13 >526 240 Vert(CT)-1.2812-13 >329 180 Horz(CT) 0.36 10 n/a n/a Scale = 1:60.3 I� 1�^ IT 0 3x12 zz PLATES GRIP MT20 244/190 MT18HS 244/190 Weight: 160 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt . 6-12 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3247/2112, 3-5=2449/1679, 5-6=-2397/1763, 6-7=5452/3624, 7-9=-5398/3482, 9-10=-5732/3689 BOT CHORD 2-14=-1865/3040, 13-14=-1865/3040, 12-13=-1223/2137, 10-12=3431/5459 WEBS 3-14=01303, 3-13=-861/619, 5-13=-216/264, 6-13=-300/527, 6-12=-2247/3526, 7-12=-323/388, 9-12=-321/306 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to 21-0-0, Interior(1) 21-0-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Bearing atjoint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at joint 10. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ® WARNING - Verity design paremeters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 rev, f0/03/2015 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall pp p�� at building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing IY1ITe k• Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSHTPII Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type city Ply THE WINDSOR T79781809 M11392 ATA COMMON 5 1 Job Reference o tional Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:14 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-dpMzW7gWEgdi6ig3UkzarX2EkWJA7jTD4RN3DCzXjGt �1-0-0 8-4-0 12-11-0 17 6 0 22-1-0 26-8-0 35-0-0 1-D-0' 8-4-0 4-7-0 4-7-0 4-7-0 4-7-0 8-4-0 -0-0 �1 0 3x6 = 4.00 12 4x5 = 17 .- 15 "" "' 14 '" 12 2x3 11 4x6 = 3x8 = 3x8 = 2x3 II 46 = Scale = 1:59.5 3x6 = 8-4-0 12-11-0 22-1-0 26.8-0 35-0-0 8-4-0 4-71 9-2-0 4-7-0 8-4-0 LOADING (psi) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2017/TPI2014 CSI. DEFL. in (loc) I/defl Ud TC 0.59 Vert(LL) 0.33 14-15 >999 240 BC 0.68 Vert(CT) -0.64 14-15 >652 180 WB 0.59 Horz(CT) 0.13 10 n/a n/a Matrix -MS LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD BOT CHORD 2x4 SP M 30 BOT CHORD WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 10=0-8-0 Max Horz 2=-179(LC 10) Max Uplift 2=-775(LC 12), 10=-775(LC 12) Max Gram 2=1399(LC 1), 10=1399(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3404/1963, 3-5=-2807/1637, 5-6=-2801/1739, 6-7=-2801/1739, 7-9=-2807/1637, 9-10=-3404/1963 BOT CHORD 2-17=-1724/3188, 15-17=-1724/3188, 14-15=-966/2053, 12-14=-1739/3188, 10-1 2=-1 739/3188 WEBS 6-14=-560/968,9-14=-681/524, 6-15=-560/968,3-15=-681/524 PLATES GRIP MT20 244/190 Weight: 166 lb FT = 0% Structural wood sheathing directly applied or 3-1-15 oc purlins. Rigid ceiling directly applied or 5-2-15 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to 21-0-0, Interior(1) 21-0-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) 100.0Ib AC unit load placed on the top chord, 17-6-0 from left end, supported at two points, 5-0-0 apart. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 775 lb uplift at joint 2 and 775 Ib uplift at joint 10. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Alban! PE No.39380 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33810 Date: March 24,2020 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not ��AA a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall p-•Y�- building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 1 rn Icy 0 Job Truss Truss Type oty, Ply THE WINDSOR T79781810 M11392 B COMMON 2 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:15 2020 Page 1 I D:_kfiGCA6bx7j2Syl HDXFw7ye3KX-5OwL)Sh87_IZuFF2SVpOlbSRwk4sA4MJ57cm"Gs i1-0-0, 8-3-5 14-0-0 17-6-0 21-0-0 26-8-11 35-0-0 $6-0-q Y-O-0' 8-3 5 5-8-11 3-6-0 3 6-0 5-8-11 8-3-5 0-0 �1 6 4.00 12 3x6 = Scale = 1:59.3 17 15 14 — 12 3x4 — 2x3 II 3x6 = 3x4 = 3x4 = 3x6 = 2x3 II 3x4 = 14-0-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defi Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.34 Vert(LL) -0.11 14-15 >766 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.38 Vert(CT) -0.24 17-20 >715 180 BCLL 0.0 Rep Stress Incr YES WB 0.63 Horz(CT) 0.03 10 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 149 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. All bearings 0-8-0. (Ib) - Max Horz 2=-179(LC 10) Max Uplift All uplift 100 lb or less aljoint(s) except 2=-371(LC 12), 15=-453(LC 12), 14=-453(LC 12), 10=-371(LC 12) Max Grav All reactions 250 lb or less at joints) except 2=602(LC 1), 15=B44(LC 17), 14=840(LC 18), 10=602(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-945/572, 5-6=-1811256, 6-7=-181/258, 9-10=-945/574 BOT CHORD 2-17=-407/878, 15-17=-407/878, 12-14=-393/858, 10-12=-393/858 WEBS 3-17=-5/301, 3-15=-8191591, 5-15=-277/325, 7-14=-277/326, 9-14=-819/592, 9-12=-5/301 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf, BCDL=3.Opsf,, h=15ft; B=70ft; L=35ft; eave=5ft; Cat. II: Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to 21-0-0, Interior(1) 21-0-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip This item has been DOL=1.60 electronically signed and 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. sealed by Albani, Thomas, PE 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide using a Digital Signature. will fit between the bottom chord and any other members, with BCDL = 10.Opsf. Printed this 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 371 lb uplift at joint 2, 453 lb uplift at copies of joint 15, 453 lb uplift at joint 14 and 371 lb uplift at joint 10. document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Alban! PE No.39380 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ® WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 111II-7473 rev. 10/03/2015 BEFORE USE. ' Design valid for use only with MTekO connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing !MiTek' is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPH Quality Criteria, DSB.89 and BCSI Building Component 6904 Parke East Blvd. Safetyinformadon available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type 0ty Ply T19781B11 M11392 BHA BOSTON HIP 1 1 �THEWINDSOR Job Reference (optional) "namuers r rues, Inc., MR tierce, M o.44U s mar a zuzu mt I etc mous.as, Inc. I ue mar Z4 l.:oq:, r ..,u rage i ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-202688iPXb7HzCPe9tXHTAgmFjM 1 K3EfmPcjgxzxjGq 15E-0 21-6-0 1-0-0 7-04- 16-0 11-6-0 13-6-01 -0 17-6-0 19-6-0 21-0-0 23-6.0 25-6.0 28.0.0 35.0.0 6-0-0 -0-0 7-0-0 2-6-0 2-0-0 2-0-0 01 1-6-0 2-0-0 2-0-0 1-6-0 2-0-0 2-0-0 2.6-0 7-0-0 -0-0 Scale = 1:62.4 TOP CHORD MUST BE BRACED BY END JACKS, ROOF DIAPHRAGM, OR PROPERLY CONNECT 4.00 12 4x4 = PURLINS AS SPECIFIED. 57 15 58 17 56 12 59 3x6 55 9 20 54 8 60 22 3x6 5x12 =53 4 6 x6 = 3x4 2,61 26 5x12 C 3 11 16 19 1 23 mac! 63 14 52 11 r; ,01 2 28 29 N N I� 35 42 43 34 44 33 45 46 47 48 32 49 31 50 51 30 34 = 6x8 = 6x8 = 3x6 = 3x4 = 3x4 = 7-0-0 14-" 21-0-0 28-0-0 35-0-0 7-0-0 7-0-0 7-0-0 7-0-0 7-0-0 Plate Offsets_(X,Y)-[3:0-6-4,0-1-121,[32:0-3-8,0-3-01 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (IDc) Well L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.51 Vert(LL) 0.13 35-38 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.54 Vert(CT) -0.16 35-38 >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.65 Horz(CT) 0.04 28 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 208 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural woad sheathing directly applied or 5-3-13 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 3-33, 27-32 JOINTS 1 Brace at Jt(s): 11, 19, 16, 7, 23 REACTIONS. All bearings 0-8-0. (lb) - Max Horz 2=179(LC 7) Max Uplift All uplift 100 lb or less at joints) except 2=-565(LC 8), 33=-1269(LC 8), 32=1017(1_13 8), 28=-434(LC 8) Max Grav All reactions 250 lb or less at joint(s) except 2=812(LC 17), 33=1825(LC 1), 32=1529(LC 1), 28=626(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1692/1103, 3-4=-106/259, 27-28=1129/710, 3-5=-441/520, 5-7=-436/514, 7-10=-436/514, 10-11=-436/514, 11-13=-436/514, 13-16=-436/514, 16-18=-436/514, 18-19=-436/514, 19-21=-382/412, 21-23=-382/412, 23-25=-382/412, 25-27=-387/418 BOT CHORD 2-35=-939/1572, 33-35=-909/1484, 32-33=-382/400, 30-32=-575/1004, 28-30=-568/1039 WEBS 3-35=-191/649, 27-30=0/451, 3-33=2090/1523, 11-33=-8101782, 19-32=-772/745, 27-32=-1484/1044, 9-10=-463/453, 20-21=-462/454 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are 2x3 MT20 unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 565 lb uplift at joint 2, 1269 lb uplift at joint 33, 1017 lb uplift at joint 32 and 434 lb uplift at joint 28. 8) Graphical pudin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 265 lb down and 381 lb up at 7-0-0, 158 lb down and 206 lb up at 9-0-12, 158 lb down and 206 lb up at 11-0-12, 158 lb down and 206 lb up at 13-0-12, 158 lb down and 206 lb up at 15-0-12, 158 lb down and 206 lb up at 17-0-12, 158 lb down and 206 lb up at 17-11-4, 158 lb down and 206 lb up at 19-11-4, 158 lb down and 206 lb up at 21-11-4, 158 lb down and 206 lb up at 23-11-4, and 158 lb down and 206 lb up at 25-11-4, and 158 lb down and 206 lb up at 27-114 on top chord, and 373 lb down and 236 lb up at 7-0-0, 69 lb down at 9-0-12, 69 lb down at 11-0-12, 69 lb down at 13-0-12, 69 lb down at 15-0-12, 69 lb down at 17-0-12, 69 lb down at 17-11-4, 69 lb down at This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Alban! PE No.39380 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24.2020 19-11-4 69 lb down at 21-11-4 69 Ib down at 23-11 4 and 69 Ib down at 25-11-4 and 69 lb down at 27-11-4 on bottom chord. eslgrifsele tmech ewce sportsib0' othe ®1fiiillFttie1 (3e�i '�)tSe0f10nJ�Da+�67Aj7{Ijlad t®'Ig10cfB0emwtmtmmwa7B Hobz&avAxny ETbad0.(wis BEFOREUSE. DoigfltiAli ev'r21 MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a trpyq pyyt�seyAlyiCjng designer must verify the applicability of design parameters and property Incorporate this design Into the overall bw i esi n. g I , to prevent buckling of individual truss web andtor chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?Plf Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. �� r MiTek' 6904 Parke East Blvd. Tampa, FL 36610 Job Truss Truss Type Qty, Ply �TFIEWINDSOR T19781811 M11392 BHA BOSTON HIP 1 1 Job Reference' o tional Chambers 1 Russ, Inc., FOR Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:17 2020 Page 2 ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-202688iPXb?HzCPe9tXHTAgmFjM1 K3EfmPcjgXzXjGq LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 36-39=-20, 1-3=-54, 3-15=-54, 15-27=-54, 27-29=-54 Concentrated Loads (lb) Vert: 35=-373(F) 30=-23(F) 42=-23(F) 43=-23(F) 44=-23(F) 45=-23(F) 46=-23(F) 47=-23(F) 48=23(F) 49=-23(F) 50=-23(F) 51=-23(F) 52=-169(F) 53=-118(F) 54=-118(F) 55=-118(F) 56=-118(F) 57=-118(F) 58=-118(F) 59=-118(F)60=-118(F) 61=-118(F) 62=-118(F) 63=118(F) ® WARNING • Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web andfor chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke Fast Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply T19781812 M11392 GRA HIP 1 1 �THEWINDSOR Job Reference o tional L,namDers I russ, Inc., don vierce, rL 6.24u s mar 9 2uzu Mt i ex Inoustnes, Inc. t ue Mar 24 12:54:19 ZUZU . Page 1 ID: _kfiGCA6bx7j2Syl HDXFw7ye3KX-_nAsZgkf3CG_CWZOHIZIYbl?yXOVouLyEj5gvQzXjGo 111 7-0-0 14-11-0 21-5-2 28-0-0 35-0-0 6-0 -0-0 716 7-11-0 6-6-2 6.6-14 7-0-0 -0-0 Scale = 1:60.3 5x12 MT18HS = 4.00 12 3x5 II 3x6 = 48 = 3 22 23 24 25 4 26 27 5 28 629 30 31 32 4x8 = 15 33 34 14 35 13 36 37 38 1239 11 40 41 10 3x4 = 2x3 II 3x6 = 5x14 = 3x4 = 46 = 24 II 3x5 = 28-0-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udefi L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.94 Vert(LL) 0.30 10-21 >792 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.67 Vert(CT) -0.30 10-12 >812 180 MT18HS 244/190 BCLL 0.0 ' Rep Stress Incr NO WB 1.00 Horz(CT) 0.09 8 rile n/a BCDL 10.0 Code FBC2017rrP12014 Matrix -MS Weight: 153 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 3-9-5 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 4-6-8 oc bracing. WEBS 2x4 SP No.3 *Except* WEBS 1 Row at midpt 6-13 4-13: 2x6 SP No.2 2 Rows at 1/3 pts 3-13 REACTIONS. (size) 2=0-B-0, 13=0-8-0, 8=0-8-0 Max Horz 2=-78(LC 6) Max Uplift 2=-448(LC 8), 13=-2442(LC 8). 8=-1159(LC 8) Max Grav 2=755(LC 17), 13=3223(LC 1), 8=1225(LC 18) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1534/729, 3-4=-1052/1347, 4-6=-1052/1347, 6-7=-1946/1834, 7-8=-2978/2565 BOT CHORD 2-15=-586/1423, 13-15=-596/1464, 12-13=-1710/1946, 10-12=-2359/2830, 8-10=-2329/2789 WEBS 3-15=-159/733, 3-13=-2917/1869, 4-13=-848/801, 6-13=3504/3050, 6-12=-430/666, 7-12=-940/731, 7-10=489/690 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); porch right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. This Item has been 4) All plates are MT20 plates unless otherwise indicated. electronically Signed and 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. • Sealed by Albanl, Thomas, PE 6) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide using a Digital Signature. will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 448 lb uplift at joint 2, 2442 lb uplift at Printed copies of this joint 13 and 1159 lb uplift atjoint 8. document are not considered 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 203 lb down and 329 lb up at' Signed and Sealed and the 7-0-0, 90 lb down and 155 lb up at 9-0-12, 90 lb down and 155 lb up at 11-0-12, 90 lb down and 155 lb up at 13-0-12, 90 lb down signature must be verified and 155 lb up at 15-0-12, 90 lb down and 155 lb up at 17-0-12, 90 lb down and 155 lb up at 17-114, 90 Ib down and 155 lb up at 19-114, 90 lb down and 155 lb up at 21-114, 90 lb down and 155 lb up at 23-114, and 90 lb down and 155 lb up at 25-114, and On any electronic copies. 203 lb down and 329 lb up at 28-0-0 on top chord, and 452 lb down and 263 lb up at 7-0-0, 63 lb down and 3 lb up at 9-0-12, 63 lb Thomas A. Albani PE No.39380 down and 3 lb up at 11-0-12, 63 lb down and 3 lb up at 13-0-12, 63 lb down and 3 lb up at 15-0-12, 63 lb down and 3 lb up at MiTek USA, Inc. FL Cart 6634 17-0-12, 63 lb down and 3 lb up at 17-114, 63 lb down and 3 lb up at 19-11-4, 63 lb down and 3 lb up at 21-114, 63 lb down and 6904 Parke East Blvd. Tampa FL 33610 3 lb up at 23-114, and 63 lb down and 3 lb up at 25-11-4, and 452 lb down and 263 lb up at 27-114 on bottom chord. The Date: design/selection of such connection device(s) is the responsibility of others. March 24.2020 9 In the LOAD CASES section loads applied to the face of the truss are noted as front F or back B . ALL A'EAf,'ASEP.s*apdau4ters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. DGMtf 1W drgfpd Wave MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Bef re se, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall p�• building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing IYIiTe k• Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 Quality Criteria, DSB-89 and BCS/Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply T19781812 M11392 GRA HIP 1 1 �THEWINDSOR Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:19 2020 Page 2 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-_nAsZgkf3CG_CWZOHIZIYb17yXOVouLyEj5gvQzXjGo LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-7=-54, 7-9=-54, 16-19=-20 Concentrated Loads (lb) Vert:3=-147(B) 7=-147(B) 15=-452(B) 13=40(B) 4=-90(B) 10=452(B) 22=-90(B) 23=-90(B) 24=-90(B) 26=-90(B) 27=-90(B) 28=-90(B) 30=-90(B) 31=-90(B) 32=-90(B)33=-40(B)34=-40(B)35=40(B)36=-40(B)37=-40(B)38=-40(B)39=-40(B)40=-40(B)41=40(B) ®WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MlTEK REFERENCE PAGE MN•7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall r building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M1Te k' is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPIf Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type city Ply THE WINDSOR T19781813 M11392 AMONO TRUSS 8 1 Job Reference o tional Chambers Truss, Inc., Fort Pierce, FL -1-0-0 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:19 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KK-_nAsZgkf3CG_CWZOHIZIYbIBwXAho7vyEj5gvQzxjGo 3x4 = Scale = 1:6.1 1-0-0 1-0-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) -0.00 5 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.02 Vert(CT) -0.00 5 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 4 n/a n/a BCDL 10.0 Code FBC20171TP12014 Matrix -MP Weight: 5 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins. BOT CHORD 2x4 SP NG.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=48(LC 12) Max Uplift 3=-4(LC 9), 2=140(LC 12) Max Grav 3=11(LC 17), 2=118(LC 1), 4=17(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 lb uplift at joint 3 and 140 lb uplift at joint 2. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Alban! PE No.39380 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11,1II.7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not ��®® a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall fr•�iY�- building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke Fast Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply THE WINDSOR T19781814 M11392 J3 MONO TRUSS 8 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:20 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-SzkEmAIHgWOrgg8Dq74_5oIMZxUHXa95SNgNRszXjGn -1-0-0 3-0-0 1-0-0 3-0-0 Scale = 1:9.4 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) 0.01 4-7 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.19 Vert(CT) -0.01 4-7 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 We n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 11 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Harz 2=85(LC 12) Max Uplift 3=-54(LC 12), 2=-147(LC 12), 4=-4(LC 12) Max Grav 3=64(LC 1), 2=173(LC 1), 4=50(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft: Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 2-11-8 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 54 Ib uplift at joint 3, 147 lb uplift at joint 2 and 4 lb uplift at joint 4. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED M17EK REFERENCE PAGE M11•7473 rev. 1010312015 BEFORE USE. -- Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall p r building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing iV9iTe k• Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 11 fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke Fast Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type city Ply THE WINDSOR T19781815 M11392 J5 MONO TRUSS 8 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:21 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-wAHc_WlvbgWiRpjPOibDeOrOoKiYG1 PFhl awzlzXjGm -1-0-0 i 5-0-0 i 1-0-0 5-0-0 Scale = 1:12.7 3x4 = 5-0-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.73 Vert(LL) 0.07 4-7 >863 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.70 Vert(CT) -0.06 4-7 >964 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017[TP12014 Matrix -MP Weight: 17 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=123(LC 12) Max Uplift 3=-104(LC 12), 2=-177(LC 12), 4=-9(LC 12) Max Grav 3=115(LC 1), 2=243(LC 1), 4=87(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf: BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 4-11-8 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 104 lb uplift at joint 3, 177 lb uplift at joint 2 and 9 lb uplift at joint 4. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111.7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall r building design. Bracing indicated isto prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPH Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type city Ply THE WINDSOR T19781816 M11392 J7 MONO TRUSS 24 1 Job Reference o tional Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:212020 Page 1 ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-wAHc_WlvbgWiRpjPOibDeOrSnKmPG 1 PFh1 awzlzXjGm -1-0-0 7-0-0 1-0-0 7-0-0 3x4 = 7-0-0 Scale: 314"=l' LOADING (psi) SPACING- 2-0-0 CSI. DEFL. in (loc) Vdefi Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.47 Vert(LL) 0.17 4-7 >494 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.39 Vert(CT) -0.19 4-7 >447 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017rrP12014 Matrix -MP Weight: 23 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=161(LC 12) Max Uplift 3=-153(LC 12), 2=-211(LC 12), 4=-12(LC 12) Max Grav 3=165(LC 1), 2=315(LC 1), 4=125(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 6-11-8 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 153 lb uplift at joint 3, 211 lb uplift at joint 2 and 12 lb uplift at joint 4. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ® WARNING • Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MN•7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall r building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safetylnformatlon available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 Job Truss Truss Type Qty Ply THE WINDSOR T19781817 M11392 KJ7 MONO TRUSS 4 1 • Job Reference o 8onal Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:22 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-OMr_BsmXM7eZ3zlbyQ7SADNhnk9g?RvOwhJU WlzXjGI 1-5 0 6-8-12 9-10-1 1-5-0 6-8-12 3-1-5 3x4 = 5 3x4 = Scale = 1:20.6 6-8-12 9-10-1 6-8-12 3-1-5 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Vdefl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.20 Vert(LL) -0.04 7-10 >999 240 MT20 244/190 TCDL . 7.0 Lumber DOL 1.25 BC 0.26 Vert(CT) -0.08 7-10 >999 180 BCLL 0.0 ' Rep Stress Incr NO WS 0.24 Horz(CT) 0.01 5 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 38 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 4=Mechanical, 2=0-11-5, 5=Mechanical Max Horz 2=192(LC 8) Max Uplift 4=-131(LC 8), 2=-262(LC 8), 5=-238(LC 8) Max Grav 4=156(LC 13), 2=379(LC 1), 5=461(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-838/366 BOT CHORD 2-7=-487/798, 6-7=-487/798 WEBS 3-7=0/307, 3-6=-920/561 NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 131 lb uplift at joint 4, 262 lb uplift at joint 2 and 238 lb uplift at joint 5. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-54 Trapezoidal Loads (plf) Vert: 2=0(F=27, B=27)-to-4=-133(F=-39, B=-39), 8=0(F=10, B=10)-to-5=-49(F=-15, B=-15) This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cart 6634 e904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. f010312015 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall�- building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Mi lek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandda, VA 22314. Tampa, FL 36610 Symbols Numbering System ® General Safety Notes PLATE LOCATION AND ORIENTATION rf-3j4' Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. Ole For 4 x 2 orientation, locate plates 0- "id' from outside edge of truss. This symbol indicates the required direction of slots in connector plates. Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. 11 U 1114:I.1111111 3:7_ lliI► 110107%111MZI Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 6-4-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) 2 3 TOP CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. PRODUCT CODE APPROVALS ICC-ES Reports: ESR-1311, ESR-1352, ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. © 2012 MITekO All Rights Reserved MiTek MiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015 Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSUTPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.