Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
FL17022-R7
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments 08/18/2017v. date reapply 08/21/17
Archived
Product Manufacturer Extreme Metal Fabricators, LLC
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
fivalidation@yahoo.com
Authorized Signature Richard McKuhen
fivalidation@yahoo.com
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
rchard@emfab.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the LOCKE BOWDEN
Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R. Priest, P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL17022 R7 COI FL 17022.1 5 V CRIMP ssr pdf
Standard
TAS 125
UL 1897
UL 580
Year
2003
2012
2006
https://www.floridabuilding.org/prlpr_app_dti.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 1/3
2/4/2019
Florida Building Code Online
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
FL # Model, number or Name
17022.1 1 "5V Crimp" (R6)
Method 1 Option D
08/18/2017
08/25/2017
08/28/2017
10/10/2017
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ Table A
Other: Refer to evaluation report for conditions. Install the
assembly in compliance with the installation method listed in
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022.2 12 - "5V Crimp" (R6)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure. +N/A/ Table A
Other: Refer to evaluation report for conditions.Install the
assembly in compliance with the installation method listed in
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022.3 13 - "1.5" Mechanical Seam" (R5)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other. Refer to evaluation report for conditions and limitations
of use. Install the assembly in compliance with the installation
method listed in this report and applicable code sections of
FBC. Refer to manufacturer's installation instructions.
17022.4 4 - "1.5" Mechanical Seam" (R5)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and limitations
of use. Install the assembly in compliance with the installation
method listed in this report and applicable code sections of
FBC. Refer to manufacturer's installation instructions.
17022.5 5 - "1 in. Nail Strip" (R5)
Limits of Use
Approved for use in HVHZ-- No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and limitations
of use. Install the assembly in compliance with the installation
Description
26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel
mechanically attached to 15/32" plywood or Wood Deck with
fasteners
Installation Instructions
FL17022 R7 II FL 17022.1 5 V CRIMP ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.pdf
Created by Independent Third Party: Yes
0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel,
mechanically attached to 15/32" plywood or Wood Deck with
exposed fasteners
Installation Instructions
FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssr pdf
Created by Independent Third Party: Yes
1.5" rib height, 16" wide, 24 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with clips and fasteners.
Installation instructions
FL17022 R7 II FL 17022.3 1.5 MECHANICAL
seam 24ga ssnpdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.3 1.5 MECHANICAL
seam 24ga ssr.pdf
Created by Independent Third Party: Yes
1.5" rib height, 16" wide, 0.032" aluminum, standing seam roof
panel mechanically attached to 15/32" plywood or Wood Deck
with clips and fasteners.
j Installation Instructions
FL17022 R7 II FL 17022.4 MECHANCIAL SEAM
ALUMINUM ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM
ALUMINUM ssr.odf
Created by Independent Third Party: Yes
1" rib height, 16" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with fasteners.
Installation Instructions
FL17022 R7 II FL 17022 5 1.0 NAILSTRIP ssr. pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssr pdf
Created by Independent Third Party: Yes
https:llwww.floridabuilding.orglprlpr app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 2/3
2/4./2019
Florida Building Code Online
method listed in this report and applicable code sections of
FBC. Refer to manufacturer's installation instructions.
17022.6
6 - "1 in. Nail Strip" (R5)
1" rib height, 16" wide, 0.032" aluminum, standing seam roof
panel mechanically attached to attached to 15/32" plywood or
Wood Deck with fasteners,
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.032
ALUM ssr.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and limitations
Evaluation Reports
of use. Install the assembly in compliance with the installation
FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032
ALUM ssr.pdf
Created by Independent Third Party: Yes
method listed in this report and applicable code sections of
FBC. Refer to manufacturer's installation instructions.
17022.7
7 - "1.5 in. Nail Strip" (115)
1.5" rib height, 19" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.7 1.5 Nail Strip 26GA ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and limitations
FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.pdf
Created by Independent Third Party: Yes
of use. Install the assembly in compliance with the installation
method listed in this report and applicable code sections of
FBC. Refer to manufacturer's installation instructions.
M
17022.8 8 - "EMAX Rib" (R5) 29 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R7 II FL 177022.8 EMAX Rib ssr.pdf
Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A Evaluation Reports
Other: Refer to evaluation report for conditions and limitations FL17022 R7 AE FL 177022.8 EMAX Rib ssr.pdf
of use. Install the assembly in compliance with the installation Created by Independent Third Party: Yes
method listed in this report and applicable code sections of
FBC. Refer to manufacturer's installation instructions.
17022.9 19 - " PBR MAX" (R5) 26 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Limits of Use I Installation Instructions
Approved for use in HVHZ: No j FL17022 R7 II FL 17022.9 PBR RIB ssr.pdf
Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A Evaluation Reports
Other: Refer to evaluation report for conditions and limitations FL17022 R7 AE FL 17022.9 PBR RIB ssnpdf
of use. Install the assembly in compliance with the installation Created by Independent Third Party: Yes
method listed in this report and applicable code sections of
FBC. Refer to manufacturer's installation instructions.
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Coo right 2007-2013, State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, ES., please click here .
Product Approval Accepts:
i!sicect Cill
Credit Card
Safe
https:(/www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 3/3
Palm City, FL 34990
Compliant with Florida Building Code 2017 (6th ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2
Yield strength: 50 ksi min., Attached to min.15/32" plywood or Wood
Deck w/ min. 0.42 specific gravity with screws. 24" Coverage
Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec. 1507.4.3
Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate
3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet
requirements)
Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to
penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
See Fastener attachment specifications above
Install Details: Table A Allowable Loads
METHOD 1
METHOD 2
METHOD 3
METHOD 4
DESIGN PRESSURE*
-86 PSF
-93.5 PSF
-101 PSF
-228 PSF
ROW SPACING
16" o.c.
16" ox.
8" ox.
6" ox.
FASTENER SPACING (ALONG Panel width)
12" o.c.
12" o.c.
12" O.C.
12" o.c.
FASTENER SIZE 1
#9
#10
#10
#10
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527
UL 580-06 & 1897-041
TAS 125-03
*EQUIVALENCY--UL 1897-04
Test Report O05893.01-450-18 05/02/14
Test Report F3366.01-450-18 12/18/15
Test Report D05893.02-450-18 07/22/14
is equivalent to test standard UL 1897-1 *Design pressure margin of safety 2,1
.. a rrr►►.._
Locke Bowden, P.E. does not have, not will acquire a financial in -� �a�jcQ�r��rira+facturin or distributing
+3 g g products
under this evaluation. �'
Locke Bowden, P.E. is not owned, operated, or controlled by aev coinpallornbbifar'turer, or distributing products under this
report. •
5 fA •Ce
e ' tie ,
FL17022.1 5V Crimp (26GA Steel), 24" Wide Roof Panel -Details
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed.
2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
Panel
Overlap
15(32" or greater Plywood, or
- Wood plank
-00 4" 000.
12"
OPTIONAL 3TMATIOW. —
Panel Profile
Nominal 12" Nominal 12"
O.G. O.C.
Fasten
9 X 1-1/2" Min. or #10 X 1-1/2" Min. per
Table "A" Hex Washer Head Screw
Spaced 12" o.c. across the Panel Width
Refer to Table "A" for Spacing Along Panel
Length
Deck-15/32" or greater
Plywood, or
-Wood plank