HomeMy WebLinkAboutAPPROVED Design Pressure Report (Reily) - Master Craft Aluminum Products Property Information Building Information
Owner: Reily Wind Zone: 160 MPH.
Address: 18 Mediterranean Blvd S Exposure Category: B
Port St Luice,F134952 Minimum Building Dimension: 24 ft.
Mean Roof Height: 15 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 52 55 7 31.0 -33.8
2 Int 37 55 7 31.7 -34.5
3 Int 52 55 7 31.0 -33.8
4 Int 52 55 7 31.0 -33.8
5 Int 72 80 7 29.6 -32.3
6 Int 74 55 7 30.3 -33.0
7 Int 26 38 7 32.5 -35.2
8 Int 26 38 7 32.5 -35.2
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.
Page 1 of 1