Loading...
HomeMy WebLinkAboutBUCHMEYER RESIDENCE_REVISION 02, 10.15.20???????SHENAM#DWG NAMEDWG NOSHEET NONORTH ARROWDETAIL TAGELEVATION SECTION TAGELEVATION MARKERLINETYPES:WORK ABOVE, BELOW, OR TO BE REMOVEDCENTERBREAK LINEDOOR TAGWINDOW TAG?DOOR NUMBERWINDOW TYPEPROPERTY LINEDIMENSIONS:5' ‐ 0"FACE OF SURFACE INDICATORNOTE: DIMENSIONS ARE TAKEN FROM/TO FACE OF STRUCTURE UNLESS NOTED OTHERWISENOTE: EXISTING DIMENSIONS INDICATED WITH (VIF) ARE SUPPLIED TO THE ARCHITECT BY OTHERS AND/OR ARE CRITICAL DIMENSIONS THAT SHALL BE FIELD VERIFIED BY THE CONTRACTORVIF5' ‐ 0"NOTE: (CLEAR) INDICATES THE DIMENSION MAY NEVER BE LESS THAN THE CLEAR DIMENSION, BUT MAY BE GREATER.  COORDINATE WITH ARCHITECT IF THE ACTUAL DIMENSION IS GREATER THAN 1"CLEAR5' ‐ 0"NOTE: (HOLD) INDICATES THE DIMENSION SHOWN MUST BE MAINTAINED.HOLD5' ‐ 0"NOTE: (+/‐) INDICATES A DIMENSION THAT CAN VARY.  COORDINATE WITH ARCHITECT IF ACTUAL DIMENSION VARIES FROM THE DIMENSION SHOWN BY MORE THAN 1".5' ‐ 0" +/‐#Pound OR Number&And@AtACT Acoustic Ceiling TileAD Area DrainAFF Above Finished FloorALUM AluminumANOD AnodizedBSMT BasementBYND BeyondBOT BottomCIP Cast In PlaceCHNL ChannelCJ Control JointCL Center LineCLG CeilingCLR ClearCMU Concrete Masonry UnitCOL ColumnCOMPR CompressibleCONC ConcreteCONT ContinuousCPT CarpetCT Ceramic TileCTYD CourtyardDBL DoubleDEMO Demolish or DemolitionDIA DiameterDIM DimensionDIMS DimensionsDN DownDR DoorDWG DrawingAd ‐Article Continues Below EA EachEJ Expansion JointEL ElevationELEC ElectricalELEV Elevator or ElevationEPDM Ethylene Propylene Diene M‐Class (Roofing)EQ EqualEXIST ExistingEXP JT Expansion JointEXT ExteriorFD Floor Drain or Fire DepartmentFEC Fire Extinguisher CabinetFIXT FixtureFLR FloorFM Filled MetalFO Face OfFND FoundationGA GaugeGALV GalvanizedGWB Gypsum Wall BoardHC Hollow CoreHI HighHM Hollow MetalHP High PointHR HourHVAC Heating, Ventilating, And Air ConditioningIRGWB Impact Resistant Gypsum Wall BoardILO In Lieu OfINSUL Insulated or InsulationINT InteriorLO LowMAX MaximumMO Masonry OpeningMECH MechanicalMEMBR MembraneMIN MinimumMRGWB Moisture‐Resistant Gypsum Wall BoardMTL MetalNIC Not In ContractNO NumberNOM NominalOC On CenterOH Overhang or Opposite HandOPP Opposite or Opposite HandOZ OuncePCC Pre‐Cast ConcretePLUMB PlumbingPLYD PlywoodPPT Pressure Preservative TreatedPNT Paint or PaintedPVC Polyvinyl ChlorideAd ‐Article Continues Below RBR RubberRCP Reflected Ceiling PlanRD Roof DrainREQD RequiredRM RoomSIM SimilarSPEC Specified OR SpecificationSPK Sprinkler or SpeakerSSTL Stainless SteelSTC Sound Transmission CoefficientSTL SteelSTRUCT Structure or StructuralT&G Tongue And GrooveTELE TelephoneTLT ToiletTME To Match ExistingTO Top OfTOC Top Of ConcreteTOS Top Of SteelTPD Toilet Paper DispenserT/D Telephone/DataTYP TypicalUNO Unless Noted OtherwiseU/S UndersideVIF Verify In FieldVP Vision PanelW/ WithWD WoodFLORIDA RESIDENTIAL BUILDING CODE 2017FLORIDA PLUMBING CODE 2017FLORIDA MECHANICAL CODE 2017FLORIDA FUEL AND GAS CODE 2017FLORIDA ACCESSIBILITY CODE 2017FLORIDA ENERGY CONSERVATION CODE 2017ST. LUCIE COUNTY CODE OF ORDINANCESNFPA 101 LIFE SAFETY CODECATEGORYEXTERIOR DOORSSINGLE HUNGMANUFACTURERPRODUCT/SYSTEM PRODUCT APPROVALSFLORIDA PRODUCT APPROVALTHERMATRUFL20468.7 R3FL16177.1FIBERGLASS OUTSWING WITH IMPACT GLASSBUILDING DESIGN PRESSURES PRODUCT DESIGN PRESSURES +50.0 PSF/‐50.0 PSFPANEL WALLHARDIESOFFITROOFING PRODUCTS5V CRIMP METAL ROOFUNDERLAYMENT5V CRIMP 180 MPH ULTSWINGINGWINDOWSSOFFITSSIDING (AT GABLE ENDS)POLYSTICK TU MAXPOLYGLASSFL5259.1 R29N/ACUSTOM WINDOWS+70.0 PSF/‐70.0 PSF< +40.0 PSF/‐51.0 PSF+41.0 PSF/‐55.0 PSFHARDIEPLANK LAP SIDINGMODEL 8100 SINGLE HUNG160 MPH ULTJAMES HARDIEFL13192.2 R5‐77.2 PSF‐49.6 PSFCUSTOM WINDOWSFL20838.1 R3SERIES 8800 XX PVC SLIDING GLASS DOOR+50 PSF/‐50 PSFSLIDING+38.0 PSF/‐48.0 PSFFABRALFIBERGLASS OUTSWING W/ IMPACT SIDELIGHTSFL13265.1 R4 JAMES HARDIE‐76 PSF‐45 PSFFL15722.2 R4FL20468.2 R3SYMBOL LEGENDAPPLICABLE CODESABBREVIATIONSSQUARE FOOTAGELOCATION MAP PROJECT DESCRIPTIONGENERAL NOTESCONTACTSOWNER: ARCHITECT: STRUCTURALENGINEER: TOMMY BUCHMEYER & BRANDY GUETTLERPHONE NUMBER: 772 . 267 . 0223MECHANICALENGINEER: NAME: TE SCHLITT ENGINEERINGADDRESS: 1575 INDIAN RIVER BLVDSUITE C-210VERO BEACH, FL 32960PHONE NUMBER: (772) - 360-4998 NAME: PRO-CALCSADDRESS: P.O.Box 882032Port St. Lucie, FL 34988PHONE NUMBER: 772-882-5700CONTRACTOR:NAMEADDRESSPHONE NUMBERSHEET LISTBUCHMEYER RESIDENCEPERMIT SET FOR CONSTRUCTIONPARCEL # : 4221-212-0040-000-420806 GLADES CUT OFF RD PORT ST LUCIE, FL 34987stacey@sw‐arc.com772 . 226 . 0148Sheet ListSheet Number Sheet Name DateCurrentRevisionCurrentRevision DateA0.0 COVER 04/20/20 2 10/08/2020A1.1 CONSTRUCTION PLAN 04/20/20A1.2 REFLECTED CEILING PLAN 04/20/20A1.3 ROOF PLAN 04/20/20A2.1 EXTERIOR ELEVATIONS 04/20/20A2.2 EXTERIOR ELEVATIONS 04/20/20A3.1 BUILDING SECTIONS 04/20/20A3.2 WALL SECTIONS 04/20/20A3.3 DETAILS 04/22/20 2 10/08/2020A4.1 WINDOWS & DOORS 04/20/20 2 10/08/2020A4.2 WINDOW AND DOORDETAILS04/20/20E1.1 ELECTRICAL PLAN 04/20/20M‐1 GENERAL NOTES 04/20/20M‐2MECHANICAL PLAN 04/20/20 2 10/08/2020M‐3MECHANICAL DETAILS 04/20/20S0.1 GENERAL NOTES 04/14/20S1.2 FOUNDATION ANDELECTRICAL CALCS04/14/20 1 07/07/2020S2.1 FRAMING PLANS AND ROOFZONE PLAN04/14/20 1 07/07/2020S3.1 STRUCTURAL WALLSECTIONS04/14/20S3.2 STRUCTURAL DETAILS 04/14/20* ALL MODIFICATIONS REQUIRE A PERMIT FROM ST. LUCIE COUNTY. ALL WORK TO BE DONE IN ACCORDANCE WITH FLORIDA BUILDING CODE AND LOCAL ORDINANCES. ANY DISCREPANCIES BETWEEN THESE DRAWINGS AND CODE REQUIREMENTS SHOULD IMMEDIATELY BE BROUGHT TO THE ARCHITECTS ATTENTION.PLUMBING CONTRACTOR TO DESIGN AND INSTALL SANITARY AND DOMESTIC WATER PER FBCCOORDINATE WITH SITE PLAN.PROVIDE STAINLESS STEEL FASTENERS AT EXTERIOR CONDITIONS.AVOID CONTACT OF DISSIMILAR METALS AT ALL CONNECTIONS.SPRAY FOAM INSULATION TO BE TESTED IN ACCORDANCE WITH FBC R316.3 OR PROVIDE AN IGNITION BARRIER PER FBC R316.6NAME: WESTERBERG ARCHITECTUREADDRESS: 7600 HIDDEN HAMMOCK LN VERO BEACH, FL 32966PHONE NUMBER: 772 . 226 . 0148AIR CONDITIONED: 2720 GROSS SFCOVERED PORCHES: 1360 SFTOTAL: 4080 SF UNDER ROOFAIR CONDITIONEDCUBIC VOLUME: 27,872 CU FTTHE PROJECT IS A NEW SINGLE FAMILY RESIDENCE. CMU STRUCTURE ON SLAB ON GRADE FOUNDATION.REV 022 NEW DRAIN PIPENEW CONCRETE SLABSHOWER LINER PER FBC P2709.2MORTAR BEDWIRE MESH REINFORCEMENTTILE BACKERBOARDRECOMMENDED:SCHLUTER KERDI‐BOARD(OR) PAPERLESS DRYWALLATTACH BOARD AND SEAL JOINTS PER MANUFACTURER'S SPECIFICATIONSTEMPERED GLASSSHOWER ENCLOSURE,OPTION PER OWNERNEW EXTERIOR WALLMEMBRANE FASTENERSMUST BE LOCATED 1" ABOVE TOP OF CURB, TYPPEA GRAVELAROUND WEEP HOLESDRAIN WITH CLAMPAND WEEP HOLESTILE WALLS AND FLOORSLOPE FLOOR1/2" PER FT*PROVIDE COATEDFASTENERS AT ALL WET LOCATIONSCURBLESS ENTRY2X4 PT SOLE PLATE,ANCHORED TO EXISTING CONCRETE SLAB,PER FBC.SOUND ATTENUATION BLANKET, FRICTION FIT2X4 STUDS, 16" O.C.1/2" GYPSUM WALL BOARD, BOTH SIDES* PROVIDE ADEQUATE BLOCKING FOR SHELVING,CLOSET RODS, CABINETS, TELEVISIONS, TOWEL BARSAND BATH ACCESSORIES, ETC.  COORDINATE LOCATIONS WITH OWNER, TYPPT 2X4 WOOD FURRING STRIPSAT 16" O.C. WITH 1/4" DIA X 3" CORROSION RESISTANT TAPCONS WITH MIN 1" EMBEDMENT6" FROM EACH END AND 24" O.C.WATER RESISTIVE BARRIER8" CMU1/2" GWB1X PT FURRING5/16" THICK HARDIPLANK SIDING BLIND NAILED  TO FURRING STRIPS IN STRICT ACCORDANCE WITH FLORIDA PRODUCT APPROVAL.3/4" R‐5 INSULATION BOARDSCALE:DATE:stacey@sw‐arc.com772 . 226 . 0148AR98136PARCEL # :3" = 1'‐0"A3.3PERMIT SET04/22/20DETAILSBUCHMEYER RESIDENCE20806 Glades Cut Off RdPort St. Lucie, FL4221‐212‐0040‐000‐43" = 1'‐0"A3.31SHOWER SECTION3" = 1'‐0"A3.32INTERIOR PARTITIONREVISIONRevision DescriptionDATE2Revision 210/08/20203" = 1'‐0"A3.33SIDING ON BLOCK DETAIL2 TYPE AWHITE VINYL FRAMEIMPACT GLASSLOW E, INSULATEDEGRESSTYPE BWHITE VINYL FRAMEIMPACT GLASSLOW E, INSULATEDEGRESSTYPE C(AT ENTRY DORMER)WHITE VINYL FRAMEIMPACT GLASSLOW E, INSULATED3' - 1"5' - 2"1' - 6"3' - 1"5' - 2"1' - 6"2' - 5 1/2"4' - 0"3' - 0"6' - 8"FIBERGLASS ENTRY DOORDOUBLE SLIDING GLASS DOORWHITE VINYL FRAMEIMPACT GLASSLOW E, INSULATEDTRIPLE SLIDING GLASS DOORWHITE VINYL FRAMEIMPACT GLASSLOW E, INSULATED5' - 11 1/2"6' - 7 1/2"8' - 11 1/2"6' - 7 1/2"MIN HEIGHT1' - 8"MIN WIDTH2' - 0"5.7 SF TOTALAT WINDOW TYPES MARKEDAS EGRESS, ENSURE MINIMUM DIMENSIONS AND CLEAR AREA ARE PROVIDED,PER FBC R310.2.1SEE A4.2 FOR WINDOW AND DOOR DETAILSMAX SILL HEIGHT3' - 8"EDFEDFBACH   SIMG   SIMJ     SIMHGJHGJ6' - 8"SCALE:DATE:stacey@sw‐arc.com772 . 226 . 0148AR98136PARCEL # :1/2" = 1'‐0"A4.1PERMIT SET04/20/20WINDOWS & DOORSBUCHMEYER RESIDENCE20806 Glades Cut Off RdPort St. Lucie, FL4221‐212‐0040‐000‐41/2" = 1'‐0"A4.11WINDOW AND DOOR ELEVATIONSDoor ScheduleMark Width Height Finish Function Notes01 3' ‐ 0" 6' ‐ 8" PAINT ON FIBERGLASS Exterior02 8' ‐ 11 1/2" 6' ‐ 7 1/2" VINYL Exterior03 5' ‐ 11 1/2" 6' ‐ 7 1/2" VINYL Exterior04 3' ‐ 0" 6' ‐ 8" PAINT ON FIBERGLASS Exterior05 2' ‐ 6" 6' ‐ 8" PAINT Interior06 2' ‐ 6" 6' ‐ 8" PAINT Interior07 2' ‐ 8" 6' ‐ 8" PAINT Interior08 6' ‐ 0" 6' ‐ 8" PAINT Interior09 2' ‐ 6" 6' ‐ 8" PAINT Interior10 2' ‐ 8" 6' ‐ 8" PAINT Interior ENSURE 29" CLEAR OPENING PER FBC R320.1.111 2' ‐ 0" 6' ‐ 8" PAINT Interior12 6' ‐ 0" 6' ‐ 8" PAINT Interior13 2' ‐ 8" 6' ‐ 8" PAINT Interior14 2' ‐ 8" 6' ‐ 8" PAINT Interior15 2' ‐ 0" 6' ‐ 8" PAINT Interior16 2' ‐ 8" 6' ‐ 8" PAINT Interior17 6' ‐ 0" 6' ‐ 8" PAINT Interior Barn Door Hardware18 3' ‐ 0" 6' ‐ 8" PAINT Interior Barn Door Hardware19 3' ‐ 0" 6' ‐ 8" PAINT Interior20 2' ‐ 8" 6' ‐ 8" PAINT Interior21 2' ‐ 8" 6' ‐ 8" PAINT Interior22 5' ‐ 0" 6' ‐ 8" PAINT Interior23 2' ‐ 6" 6' ‐ 8" PAINT Exterior24 2' ‐ 6" 6' ‐ 8" PAINT Exterior25 2' ‐ 0" 6' ‐ 8" PAINT Interior26 2' ‐ 6" 6' ‐ 8" PAINT InteriorREVISIONRevision DescriptionDATE2Revision 210/08/20202 LIQUID APPLIEDWATERPROOF COATINGAROUND WINDOW OPENINGHEADERPER STRUCTURAL DRAWINGSWEATHER RESISTIVE BARRIEROVER SHEATHING, FOLD BARRIEROVER FLASHING, SEAM & TAPEPER MANUFACTURER'S INSTALLATION INSTRUCTIONSPT WINDOW BUCKLAP SIDING TO MATCH EXISTING, INSTALL PER MANUFACTURER'S SPECIFICATIONSFLASHING,DO NOT CAULK BETWEEN FLASHING AND TRIM1/4" MAX SHIMWINDOW TRIM PER OWNERCONTINUOUS SEALANTCONTINUOUS SEALANTSILL AND TRIM PER OWNERFIBER CEMENTOR COMPOSITE TRIMCONTINUOUS POLYURETHANE SEALANT WHERE TRIM MEETS FRAMESILL DETAIL AT NEW WINDOWSHEAD DETAIL AT NEW WINDOWSGABLE END WALLAT ENTRYA ‐B ‐SELF ADHERED MEMBRANE FLASHINGSILL PAN, LAP OVERWEATHER RESISTIVE BARRIER AND WRAP UP JAMBS 4"SELF ADHERED MEMBRANE FLASHINGSKIP‐TAPE BARRIER TO FLASHINGTO ALLOW DRAINAGE0' - 0 1/4"LIQUID APPLIEDWATERPROOF COATINGAROUND WINDOW OPENINGWEATHER RESISTIVE BARRIEROVER SHEATHING, FOLD BARRIERINTO JAMB, SEAM & TAPEPER MANUFACTURER'S INSTALLATION INSTRUCTIONS2X6 WINDOW BUCKLAP SIDING TO MATCH EXISTING, INSTALL PER MANUFACTURER'S INSTALLATION INSTRUCTIONS1/4" MAX SHIMWINDOW TRIM TO MATCH EXISTINGCONTINUOUS SEALANTJAMB DETAIL AT NEW WINDOWSC ‐SELF ADHERED MEMBRANE FLASHING1/2" GYPSUM WALL BOARDCONTINUOUS  BEAD OF POLYURETHANE SEALANT OVER BACKER RODALIGN WITH DOOR TRIMFLUID APPLIED FLASHING, CONTINUOUS AROUND MASONRY OPENINGWEATHER RESISTIVE BARRIER OVER CMU, FOLD BARRIER OVER FLASHING, SEAM & TAPEPER MANUFACTURER'S INSTALLATION INSTRUCTIONSLAP SIDING AS SPECIFIED,INSTALL PER MANUFACTURER'S SPECIFICATIONS, IN STRICT ACCORDANCE WITHFLORIDA PRODUCT APPROVALFLASHING, DO NOT CAULK BETWEEN FLASHING AND TRIMWINDOW TRIM CONTINUOUS SEALANTCONTINUOUS SEALANTSILL AND TRIM,PER OWNERFIBER CEMENT OR COMPOSITE SILL AND TRIM CONTINUOUS POLYURETHANE SEALANT WHERE TRIM MEETS FRAMEF  SILL DETAIL AT CASEMENT WINDOWSD  HEAD DETAIL AT WINDOWSSKIP‐TAPE BARRIER TO FLASHINGTO ALLOW DRAINAGEE  JAMB DETAIL AT CASEMENT WINDOWSALIGN HEIGHTWITH DOOR TRIM2X6 PT BUCK, SET IN FULL BED OF POLYURETHANE SEALANT,FULLY COVER TOP AND SIDESWITH FLUID APPLIED FLASHINGANCHOR PER STRUCTURALS1/4" MAX SHIMFIBER CEMENT OR COMPOSITE TRIMCMU WALLFLUID APPLIED FLASHING, CONTINUOUS AROUNDMASONRY OPENINGPT BUCK,SET IN FULL BED OF POLYURETHANE SEALANT,FULLY COVER TOP AND SIDESWITH FLUID APPLIED FLASHINGANCHOR PER STRUCTURALSCONTINUOUS POLYURETHANE SEALANTFLUID  APPLIED FLASHINGCONTINUOUS AROUND MASONRY OPENING2X6 PT BUCK, SET IN FULL BED OF POLYURETHANE SEALANT,FULLY COVER TOP AND SIDESWITH FLUID APPLIED FLASHING,ANCHOR PER STRUCTURALSJ  SILL DETAIL AT SLIDING GLASS DOORSH  JAMB DETAIL AT SLIDING GLASS DOORSWEATHER RESISTIVE BARRIEROVER FURRING, FOLD BARRIEROVER FLASHING, SEAM & TAPEPER MANUFACTURER'S INSTALLATION INSTRUCTIONSLAP SIDING , INSTALL PER MANUFACTURER'S SPECIFICATIONS,IN STRICT ACCORDANCE WITH FLORIDA PRODUCT APPROFALFLASHING, DO NOT CAULKWINDOW TRIM PER A5.1CONTINUOUS SEALANTAND BACKER RODSKIP‐TAPE BARRIER TO FLASHINGTO ALLOW DRAINAGEPRECAST LINTEL FIBER CEMENT OR COMPOSITE TRIMG  HEAD DETAIL AT SLIDING GLASS DOORSSLOPE SILL TO DRAIN WINDOW TRIM PER OWNERPRECAST LINTEL FILLER COURSE ABOVE LINTEL,SIZED TO ACCOMODATE DOORSCHEDULED WINDOW,ANCHOR FRAME IN STRICT ACCORDANCE WITH FLORIDA PRODUCT APPROVALSCHEDULED WINDOW,ANCHOR FRAME IN STRICT ACCORDANCE WITH FLORIDA PRODUCT APPROVAL1/4" MAX SHIMFIBER CEMENTOR COMPOSITE TRIMWOOD EXTENDSION JAMBSCHEDULED WINDOW,ANCHOR IN STRICT ACCORDANCE WITH FLORIDA PRODUCT APPROVALFLUID APPLIED OR SELF ADHERED MEMBRANE OVER FLANGE AT HEAD AND JAMBS ONLYFLASHING, DO NOT CAULKSKIP ‐TAPE BARRIER TO FLASHINGCONTINUOUS SEALANT AND BACKER RODWATER RESISTIVE BARRIER,FOLD OVER  BUCKFLUID APPLIED FLASHING, CONTINUOUS AROUND MASONRY OPENINGFLASHING, DO NOT CAULK BETWEEN FLASHING AND TRIM2X6 PT BUCK, SET IN FULL BED OF POLYURETHANE SEALANT,FULLY COVER TOP AND SIDESWITH FLUID APPLIED FLASHINGANCHOR PER STRUCTURALS1/4" MAX SHIMSCHEDULED WINDOW,ANCHOR FRAME IN STRICT ACCORDANCE WITH FLORIDA PRODUCT APPROVALWEATHER RESISTIVE BARRIER OVER CMU, FOLD BARRIER OVER FLASHING, SEAM & TAPEPER MANUFACTURER'S INSTALLATION INSTRUCTIONSSKIP‐TAPE BARRIER TO FLASHINGTO ALLOW DRAINAGEPORCH FLOORTHRESHOLD SET IN BED OF POLYURETHANE SEALANT AND ANCHORED PER FLORIDA PRODUCT APPROVALNEW FOUNDATIONPER STRUCTURAL DRAWINGSFINISH FLOORINGPER OWNERDOOR TRIM CONTINUOUS SEALANTCONTINUOUS POLYURETHANE SEALANTFLUID  APPLIED FLASHINGCONTINUOUS AROUND MASONRY OPENING2X6 PT BUCK, SET IN FULL BED OF POLYURETHANE SEALANT,FULLY COVER TOP AND SIDESWITH FLUID APPLIED FLASHING,ANCHOR PER STRUCTURALSSCHEDULED DOOR,ANCHOR FRAME IN STRICT ACCORDANCE WITH FLORIDA PRODUCT APPROVAL1/4" MAX SHIMFIBER CEMENTOR COMPOSITE TRIMWOOD EXTENSION JAMBWATER RESISTIVE BARRIER,FOLD OVER  BUCKWATER RESISTIVE BARRIER,FOLD OVER BUCKSCALE:DATE:stacey@sw‐arc.com772 . 226 . 0148AR98136PARCEL # :3" = 1'‐0"A4.2PERMIT SET04/20/20WINDOW AND DOORDETAILSBUCHMEYER RESIDENCE20806 Glades Cut Off RdPort St. Lucie, FL4221‐212‐0040‐000‐43" = 1'‐0"A4.21WINDOW AND DOOR DETAILSREVISIONRevision DescriptionDATE2Revision 210/08/20202 SCALE:DATE:stacey@sw‐arc.com772 . 226 . 0148AR98136PARCEL # :M-2PERMIT SET04/20/20MECHANICAL PLANBUCHMEYER RESIDENCE20806 Glades Cut Off RdPort St. Lucie, FL4221‐212‐0040‐000‐4REVISIONRevision DescriptionDATE2Revision 210/08/20202