Loading...
HomeMy WebLinkAboutBuchmeyer Residence CO2 Load Calcs, revision, 10.15.202020-Oct-06 11:00:01 Right-Suite® Universal 2019 19.0.21 RSU27939 Page 1 ...20\Working Drawings\Buchmeyer Residence CO2.rup Calc = MJ8 Front Door faces: SE Buchmeyer Residence CO2Job:Manual S Compliance Report Oct 06, 2020Date:Entire House John TeagardinBy: ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 Project Information Buchmeyer Residence CO2For: 20806 Glades Cut Off Rd, Port St Lucie, FL 34987 Phone: 772-696-3296 Cooling Equipment Design Conditions °F75.2Entering coil DB:Btuh27875Sensible gain:°F90.4Outdoor design DB: °F63.2Entering coil WB:Btuh7364Latent gain:°F77.4Outdoor design WB: Btuh35238Total gain:°F75.0Indoor design DB: cfm1200Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ACEquipment type: 4TTR6042J1+TEM6A0C42H41++TDRModel:TraneManufacturer: cfm1200Actual airflow: % of load110Btuh30676Sensible capacity: % of load108Btuh7982Latent capacity: %79SHR:% of load110Btuh38658Total capacity: Heating Equipment Design Conditions °F69.7Entering coil DB:Btuh29059Heat loss:°F41.0Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Elec stripEquipment type: BAYHTR1510BRKCModel:TraneManufacturer: cfm1200Actual airflow: °F25Temp. rise:% of load113kW9.6Output capacity: Meets all requirements of ACCA Manual S. 2020-Oct-06 11:00:01 Right-Suite® Universal 2019 19.0.21 RSU27939 Page 1 ...20\Working Drawings\Buchmeyer Residence CO2.rup Calc = MJ8 Front Door faces: SE Buchmeyer Residence CO2Job:Building Analysis Oct 06, 2020Date:Entire House John TeagardinBy: ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 Project Information Buchmeyer Residence CO2For: 20806 Glades Cut Off Rd, Port St Lucie, FL 34987 Phone: 772-696-3296 Design Conditions Location: CoolingHeatingIndoor:7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5050Relative humidity (%)°N28Latitude: Outdoor:56.924.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) Blower doorMethod)L(15-Daily range (°F) 3 (partial) / 1Shielding / stories77-Wet bulb (°F) 50 Pa / 2323 cfmPressure / AVF7.515.0Wind speed (mph) Heating Walls Glazing Doors Ceilings Floors Infiltration Ducts % of loadBtuhBtuh/ft²Component 28.281823.5Walls 8.524839.1Glazing 2.572017.4Doors 15.946101.6Ceilings 12.536461.31.3Floors 19.356092.1Infiltration 13.13809Ducts 00Piping 00Humidification 00Ventilation0Adjustments 100.029059Total Cooling Walls Glazing Doors Ceilings Infiltration Ducts Internal Gains % of loadBtuhBtuh/ft²Component 24.668482.9Walls 25.4707826.0Glazing 2.672817.6Doors 12.835601.3Ceilings 000Floors 6.016700.6Infiltration 9.12541Ducts 00Ventilation 19.65450Internal gains 00Blower 0Adjustments 100.027875Total Latent Cooling Load = 7364 Btuh Overall U-value = 0.202 Btuh/ft²-°F Data entries checked. Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-06 11:00:01 Right-Suite® Universal 2019 19.0.21 RSU27939 Page 1 ...20\Working Drawings\Buchmeyer Residence CO2.rup Calc = MJ8 Front Door faces: SE Buchmeyer Residence CO2Job:Load Short Form Oct 06, 2020Date:Entire House John TeagardinBy: ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 Project Information Buchmeyer Residence CO2For: 20806 Glades Cut Off Rd, Port St Lucie, FL 34987 Phone: 772-696-3296 Design Information InfiltrationClgHtg Blower doorMethod9041Outside db (°F) 3 (partial) / 1Shielding / stories7570Inside db (°F) 50 Pa / 2323 cfmPressure / AVF1529Design TD (°F) L-Daily range 5050Inside humidity (%) 5724Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Trane Make Trane Trade Trane Trade TRANE Model BAYHTR1510BRKC Cond 4TTR6042J1 AHRI ref Coil TEM6A0C42H41++TDR AHRI ref 8628154 Efficiency 100 EFF Efficiency 13.5 EER, 16 SEER Heating input kW9.6 Sensible cooling Btuh31600 Heating output Btuh32757 Latent cooling Btuh8400 Temperature rise °F25 Total cooling Btuh40000 Actual air flow cfm1200 Actual air flow cfm1200 Air flow factor cfm/Btuh0.041 Air flow factor cfm/Btuh0.043 Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 0.79 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Sitting Room 176 2755 2569 114 111 Master Bedroom 269 1931 1742 80 75 WC 28 487 233 20 10 Master Bath 141 1995 1181 82 51 Master Closet 125 1330 875 55 38 Office 117 221 913 9 39 Entry 72 990 763 41 33 Playroom 162 1365 911 56 39 Bedroom 3 181 2625 1484 108 64 Pantry 18 0 0 0 0 Bath 3 65 123 304 5 13 Laundry 129 1532 1473 63 63 Bedroom 2 172 2568 1721 106 74 Bath 2 55 540 271 22 12 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-06 11:00:01 Right-Suite® Universal 2019 19.0.21 RSU27939 Page 2 ...20\Working Drawings\Buchmeyer Residence CO2.rup Calc = MJ8 Front Door faces: SE Great Room 512 6847 8610 283 371 Bedroom 4 159 1402 933 58 40 Kitchen 340 2350 3891 97 167 Entire House 2720 29059 27875 1200 1200 Other equip loads 0 0 Equip. @ 1.00 RSM 27875 Latent cooling 7364 TOTALS 2720 29059 35238 1200 1200 2020-Oct-06 11:00:01 Right-Suite® Universal 2019 19.0.21 RSU27939 Page 1 ...20\Working Drawings\Buchmeyer Residence CO2.rup Calc = MJ8 Front Door faces: SE Buchmeyer Residence CO2Job:Component Constructions Oct 06, 2020Date:Entire House John TeagardinBy: ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 Project Information Buchmeyer Residence CO2For: 20806 Glades Cut Off Rd, Port St Lucie, FL 34987 Phone: 772-696-3296 Design Conditions Location: CoolingHeatingIndoor: 7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5050Relative humidity (%)°N28Latitude: Outdoor:56.924.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) Blower doorMethod)L(15-Daily range (°F) 3 (partial) / 1Shielding / stories77-Wet bulb (°F) 50 Pa / 2323 cfmPressure / AVF7.515.0Wind speed (mph) Construction descriptions GainLoss Clg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls Blk wall, Hardie ext, R-5 int bd ins, 8" thk, 5/8" gyps 5.00.120452ne 13182.9215733.48 21732.9225943.485.00.120745se 12852.9215333.485.00.120441sw 20312.9224243.485.00.120697nw 68082.9281253.485.00.1202335all 2 x 6 R-19 401.37571.9719.00.06829se Partitions (none) Windows Double Pane, Low-E, Vinyl: Double Pane, Low-E, Vinyl; NFRC rated (SHGC=0.19); 50% blinds 45°, medium; foreground = new concrete (0.32); 10 ft overhang (4 ft window ht, 2.5 ft sep.); 25.3 ft head ht 17817.8908.9900.31010se Double Pane, Low-E, Vinyl: Double Pane, Low-E, Vinyl; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; foreground = new concrete (0.32); 12 ft overhang (5.25 ft window ht, 2.5 ft sep.); 6.8 ft head ht 29118.01418.7000.30016se 87026.92828.7000.30032nw 116123.94228.7000.30049all Double Pane, Low-E, Vinyl: Double Pane, Low-E, Vinyl; NFRC rated (SHGC=0.19); 50% blinds 45°, medium; foreground = new concrete (0.32); 12 ft overhang (5.25 ft window ht, 2.5 ft sep.); 6.8 ft head ht 115217.85828.9900.31065se 41925.91468.9900.31016nw 157119.47288.9900.31081all Double Pane, Low-E, Vinyl: Double Pane, Low-E, Vinyl; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; foreground = green grass (0.23); 2 ft overhang (5.25 ft window ht, 2.5 ft sep.); 6.8 ft head ht 57817.92828.7000.30032sw Double Pane, Low-E, Vinyl: Double Pane, Low-E, Vinyl; NFRC rated (SHGC=0.20); 50% blinds 45°, medium; foreground = new concrete (0.32); 12 ft overhang (6.7 ft window ht, 2.5 ft sep.); 6.8 ft head ht 107526.83859.5700.33040nw 161326.85779.5700.33060nw 268926.89629.5700.330101all Doors 2020-Oct-06 11:00:01 Right-Suite® Universal 2019 19.0.21 RSU27939 Page 2 ...20\Working Drawings\Buchmeyer Residence CO2.rup Calc = MJ8 Front Door faces: SE Door, mtl fbrgl type 36917.636517.46.30.60021ne 35917.635517.46.30.60020se 72817.672017.46.30.60041all Ceilings Metal Roof, Encapsulated R-19 35601.2746101.6420.00.4052811 Floors Slab on Grade 00364616.900.582216 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-06 11:00:01 Right-Suite® Universal 2019 19.0.21 RSU27939 Page 1 ...20\Working Drawings\Buchmeyer Residence CO2.rup Calc = MJ8 Front Door faces: SE Buchmeyer Residence CO2Job:Project Summary Oct 06, 2020Date:Entire House John TeagardinBy: ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 Project Information Buchmeyer Residence CO2For:20806 Glades Cut Off Rd, Port St Lucie, FL 34987 Phone: 772-696-3296 Westerberg Architecture 8196 25th St Vero Beach, FL 32866 Notes: Design Information St Lucie Co Intl, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F41 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F29 Design TD °F15Daily range L Relative humidity %50Moisture difference gr/lb57 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh25250 Structure Btuh25334 Ducts Btuh3809 Ducts Btuh2541Central vent (0 cfm) Btuh0 Central vent (0 cfm) Btuh0 (none) (none)Humidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh29059 Use manufacturer's data y Rate/swing multiplier 1.00InfiltrationEquipment sensible load Btuh27875 Method Latent Cooling Equipment Load SizingBlower door Shielding / stories 3 (partial) / 150 Pa / 2323 cfmPressure / AVF Structure Btuh4813 Ducts Btuh2550Central vent (0 cfm) Btuh0 CoolingHeating (none)27202720Area (ft²) Equipment latent load Btuh7364 2787127871Volume (ft³)Air changes/hour 0.210.38 Equipment Total Load (Sen+Lat)Btuh35238 Equiv. AVF (cfm) 99176 Req. total capacity at 0.79 SHR ton2.9 Heating Equipment Summary Cooling Equipment Summary Make Trane Make TraneTrade Trane Trade TRANE Model BAYHTR1510BRKC Cond 4TTR6042J1AHRI ref Coil TEM6A0C42H41++TDR AHRI ref 8628154Efficiency 100 EFF Efficiency 13.5 EER, 16 SEER Heating input kW9.6 Sensible cooling Btuh31600Heating output Btuh32757 Latent cooling Btuh8400 Temperature rise °F25 Total cooling Btuh40000Actual air flow cfm1200 Actual air flow cfm1200 Air flow factor cfm/Btuh0.041 Air flow factor cfm/Btuh0.043Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 0.79 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-06 11:00:01Right-Suite® Universal 2019 19.0.21 RSU27939 Page 1...20\Working Drawings\Buchmeyer Residence CO2.rup Calc = MJ8 Front Door faces: SE Buchmeyer Residence CO2Job:Right-J® Worksheet Oct 06, 2020Date:Entire House John TeagardinBy:ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Entire House Sitting Room 2 Exposed wall 216.0 ft 27.0 ft 3 Room height 10.2 ft 9.3 heat/coolft 4 Room dimensions ft11.0x16.0 5 Room area 2720.0 ft²176.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nene 3.483.48 2.922.92 473 452 1573 1318 0 0 0 0 .DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 nene 17.4017.40 17.5817.58 21 21 365 369 0 0 0 0 .WW 2 x 6 R-192 x 6 R-19 0.0680.068 sese 1.971.97 1.371.37 39 29 57 40 0 0 0 0 .GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 10 10 90 178 0 0 0 0 11 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 sese 3.483.48 2.922.92 847 745 2594 2173 0 0 0 0 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 sese 8.708.70 17.9617.96 16 16 141 291 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 65 65 582 1152 0 0 0 0 DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 sese 17.4017.40 17.5817.58 20 20 355 359 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 swsw 3.483.48 2.922.92 473 441 1533 1285 103 103 357 299 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 swsw 8.708.70 17.8617.86 32 5 282 578 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nwnw 3.483.48 2.922.92 846 697 2424 2031 149 109 380 318 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 nwnw 8.708.70 26.8726.87 32 0 282 870 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 nwnw 8.998.99 25.8625.86 16 0 146 419 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 40 0 385 1075 40 0 385 1075 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 60 0 577 1613 0 0 0 0 CC Metal Roof, Encapsul 0.405Metal Roof, Encapsul 0.405 --1.641.64 1.271.27 2811 2811 4610 3560 176 176 289 223 FF Slab on GradeSlab on Grade 0.5820.582 --16.8816.88 0.000.00 2720 216 3646 0 176 27 456 0 6 c) AED excursion 901 262 Envelope loss/gain 19641 18214 1866 2177 12 a) Infiltration 5609 1670 528 157 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 5 1150 0 0 Appliances/other 4300 0 Subtotal (lines 6 to 13)25250 25334 2394 2335 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 25250 25334 2394 2335 15 Duct loads 15%10%3809 2541 15%10%361 234 Total room load 29059 27875 2755 2569 Air required (cfm)Air required (cfm)1200 1200 114 111 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-06 11:00:01Right-Suite® Universal 2019 19.0.21 RSU27939 Page 2...20\Working Drawings\Buchmeyer Residence CO2.rup Calc = MJ8 Front Door faces: SE Buchmeyer Residence CO2Job:Right-J® Worksheet Oct 06, 2020Date:Entire House John TeagardinBy:ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Master Bedroom WC 2 Exposed wall 15.5 ft 5.5 ft 3 Room height 9.3 heat/coolft 9.3 heat/coolft 4 Room dimensions ft269.0x1.0 ft5.5x5.0 5 Room area 269.0 ft²27.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nene 3.483.48 2.922.92 0 0 0 0 0 0 0 0 .DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 nene 17.4017.40 17.5817.58 0 0 0 0 0 0 0 0 .WW 2 x 6 R-192 x 6 R-19 0.0680.068 sese 1.971.97 1.371.37 0 0 0 0 0 0 0 0 .GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 0 0 0 0 0 0 0 0 11 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 sese 3.483.48 2.922.92 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 sese 8.708.70 17.9617.96 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 0 0 0 0 0 0 0 0 DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 sese 17.4017.40 17.5817.58 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 swsw 3.483.48 2.922.92 145 112 391 327 51 51 178 149 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 swsw 8.708.70 17.8617.86 32 5 282 578 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nwnw 3.483.48 2.922.92 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 nwnw 8.708.70 26.8726.87 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 nwnw 8.998.99 25.8625.86 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 CC Metal Roof, Encapsul 0.405Metal Roof, Encapsul 0.405 --1.641.64 1.271.27 269 269 441 341 28 28 45 35 FF Slab on GradeSlab on Grade 0.5820.582 --16.8816.88 0.000.00 269 16 262 0 28 6 93 0 6 c) AED excursion 247 -5 Envelope loss/gain 1375 1493 316 179 12 a) Infiltration 303 90 107 32 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1678 1583 423 211 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1678 1583 423 211 15 Duct loads 15%10%253 159 15%10%64 21 Total room load 1931 1742 487 233 Air required (cfm)Air required (cfm)80 75 20 10 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-06 11:00:01Right-Suite® Universal 2019 19.0.21 RSU27939 Page 3...20\Working Drawings\Buchmeyer Residence CO2.rup Calc = MJ8 Front Door faces: SE Buchmeyer Residence CO2Job:Right-J® Worksheet Oct 06, 2020Date:Entire House John TeagardinBy:ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Master Bath Master Closet 2 Exposed wall 20.5 ft 12.5 ft 3 Room height 9.3 heat/coolft 9.3 heat/coolft 4 Room dimensions ft141.3x1.0 ft125.3x1.0 5 Room area 141.3 ft²125.3 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nene 3.483.48 2.922.92 0 0 0 0 0 0 0 0 .DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 nene 17.4017.40 17.5817.58 0 0 0 0 0 0 0 0 .WW 2 x 6 R-192 x 6 R-19 0.0680.068 sese 1.971.97 1.371.37 0 0 0 0 0 0 0 0 .GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 0 0 0 0 0 0 0 0 11 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 sese 3.483.48 2.922.92 117 100 350 293 117 100 350 293 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 sese 8.708.70 17.9617.96 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 16 16 146 288 16 16 146 288 DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 sese 17.4017.40 17.5817.58 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 swsw 3.483.48 2.922.92 75 75 260 218 0 0 0 0 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 swsw 8.708.70 17.8617.86 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nwnw 3.483.48 2.922.92 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 nwnw 8.708.70 26.8726.87 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 nwnw 8.998.99 25.8625.86 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 CC Metal Roof, Encapsul 0.405Metal Roof, Encapsul 0.405 --1.641.64 1.271.27 141 141 232 179 125 125 205 159 FF Slab on GradeSlab on Grade 0.5820.582 --16.8816.88 0.000.00 141 21 346 0 125 13 211 0 6 c) AED excursion -23 -17 Envelope loss/gain 1332 954 911 722 12 a) Infiltration 401 119 244 73 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1733 1074 1156 795 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1733 1074 1156 795 15 Duct loads 15%10%261 108 15%10%174 80 Total room load 1995 1181 1330 875 Air required (cfm)Air required (cfm)82 51 55 38 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-06 11:00:01Right-Suite® Universal 2019 19.0.21 RSU27939 Page 4...20\Working Drawings\Buchmeyer Residence CO2.rup Calc = MJ8 Front Door faces: SE Buchmeyer Residence CO2Job:Right-J® Worksheet Oct 06, 2020Date:Entire House John TeagardinBy:ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Office Entry 2 Exposed wall 0 ft 6.5 ft 3 Room height 9.3 heat/coolft 9.3 heat/coolft 4 Room dimensions ft13.0x9.0 ft11.0x6.5 5 Room area 117.0 ft²71.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nene 3.483.48 2.922.92 0 0 0 0 0 0 0 0 .DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 nene 17.4017.40 17.5817.58 0 0 0 0 0 0 0 0 .WW 2 x 6 R-192 x 6 R-19 0.0680.068 sese 1.971.97 1.371.37 0 0 0 0 39 29 57 40 .GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 0 0 0 0 10 10 90 178 11 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 sese 3.483.48 2.922.92 0 0 0 0 22 1 4 4 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 sese 8.708.70 17.9617.96 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 0 0 0 0 0 0 0 0 DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 sese 17.4017.40 17.5817.58 0 0 0 0 20 20 355 359 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 swsw 3.483.48 2.922.92 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 swsw 8.708.70 17.8617.86 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nwnw 3.483.48 2.922.92 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 nwnw 8.708.70 26.8726.87 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 nwnw 8.998.99 25.8625.86 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 CC Metal Roof, Encapsul 0.405Metal Roof, Encapsul 0.405 --1.641.64 1.271.27 117 117 192 148 72 72 117 91 FF Slab on GradeSlab on Grade 0.5820.582 --16.8816.88 0.000.00 117 0 0 0 72 7 110 0 6 c) AED excursion -18 -15 Envelope loss/gain 192 130 733 656 12 a) Infiltration 0 0 127 38 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 700 0 Subtotal (lines 6 to 13)192 830 860 693 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 192 830 860 693 15 Duct loads 15%10%29 83 15%10%130 70 Total room load 221 913 990 763 Air required (cfm)Air required (cfm)9 39 41 33 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-06 11:00:01Right-Suite® Universal 2019 19.0.21 RSU27939 Page 5...20\Working Drawings\Buchmeyer Residence CO2.rup Calc = MJ8 Front Door faces: SE Buchmeyer Residence CO2Job:Right-J® Worksheet Oct 06, 2020Date:Entire House John TeagardinBy:ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Playroom Bedroom 3 2 Exposed wall 12.0 ft 27.5 ft 3 Room height 9.3 heat/coolft 9.3 heat/coolft 4 Room dimensions ft13.5x12.0 ft181.0x1.0 5 Room area 162.0 ft²181.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nene 3.483.48 2.922.92 0 0 0 0 145 145 503 422 .DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 nene 17.4017.40 17.5817.58 0 0 0 0 0 0 0 0 .WW 2 x 6 R-192 x 6 R-19 0.0680.068 sese 1.971.97 1.371.37 0 0 0 0 0 0 0 0 .GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 0 0 0 0 0 0 0 0 11 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 sese 3.483.48 2.922.92 112 96 333 279 112 96 333 279 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 sese 8.708.70 17.9617.96 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 16 16 146 288 16 16 146 288 DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 sese 17.4017.40 17.5817.58 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 swsw 3.483.48 2.922.92 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 swsw 8.708.70 17.8617.86 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nwnw 3.483.48 2.922.92 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 nwnw 8.708.70 26.8726.87 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 nwnw 8.998.99 25.8625.86 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 CC Metal Roof, Encapsul 0.405Metal Roof, Encapsul 0.405 --1.641.64 1.271.27 162 162 266 205 181 181 297 229 FF Slab on GradeSlab on Grade 0.5820.582 --16.8816.88 0.000.00 162 12 203 0 181 28 464 0 6 c) AED excursion -18 -29 Envelope loss/gain 947 755 1743 1189 12 a) Infiltration 235 70 537 160 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1182 825 2281 1349 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 5 3 0 0 14 Subtotal 1186 828 2281 1349 15 Duct loads 15%10%179 83 15%10%344 135 Total room load 1365 911 2625 1484 Air required (cfm)Air required (cfm)56 39 108 64 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-06 11:00:01Right-Suite® Universal 2019 19.0.21 RSU27939 Page 6...20\Working Drawings\Buchmeyer Residence CO2.rup Calc = MJ8 Front Door faces: SE Buchmeyer Residence CO2Job:Right-J® Worksheet Oct 06, 2020Date:Entire House John TeagardinBy:ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Pantry Bath 3 2 Exposed wall 0 ft 0 ft 3 Room height 10.8 heat/coolft 9.3 heat/coolft 4 Room dimensions ft4.5x4.0 ft65.3x1.0 5 Room area 18.0 ft²65.3 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nene 3.483.48 2.922.92 0 0 0 0 0 0 0 0 .DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 nene 17.4017.40 17.5817.58 0 0 0 0 0 0 0 0 .WW 2 x 6 R-192 x 6 R-19 0.0680.068 sese 1.971.97 1.371.37 0 0 0 0 0 0 0 0 .GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 0 0 0 0 0 0 0 0 11 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 sese 3.483.48 2.922.92 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 sese 8.708.70 17.9617.96 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 0 0 0 0 0 0 0 0 DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 sese 17.4017.40 17.5817.58 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 swsw 3.483.48 2.922.92 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 swsw 8.708.70 17.8617.86 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nwnw 3.483.48 2.922.92 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 nwnw 8.708.70 26.8726.87 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 nwnw 8.998.99 25.8625.86 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 CC Metal Roof, Encapsul 0.405Metal Roof, Encapsul 0.405 --1.641.64 1.271.27 19 19 31 24 65 65 107 83 FF Slab on GradeSlab on Grade 0.5820.582 --16.8816.88 0.000.00 18 0 0 0 65 0 0 0 6 c) AED excursion -1 -6 Envelope loss/gain 31 24 107 77 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 200 Subtotal (lines 6 to 13)31 24 107 277 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -31 -24 0 0 14 Subtotal 0 0 107 277 15 Duct loads 15%10%0 0 15%10%16 28 Total room load 0 0 123 304 Air required (cfm)Air required (cfm)0 0 5 13 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-06 11:00:01Right-Suite® Universal 2019 19.0.21 RSU27939 Page 7...20\Working Drawings\Buchmeyer Residence CO2.rup Calc = MJ8 Front Door faces: SE Buchmeyer Residence CO2Job:Right-J® Worksheet Oct 06, 2020Date:Entire House John TeagardinBy:ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Laundry Bedroom 2 2 Exposed wall 12.0 ft 27.0 ft 3 Room height 9.3 heat/coolft 9.3 heat/coolft 4 Room dimensions ft129.3x1.0 ft171.9x1.0 5 Room area 129.3 ft²171.9 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nene 3.483.48 2.922.92 112 91 317 265 117 117 406 340 .DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 nene 17.4017.40 17.5817.58 21 21 365 369 0 0 0 0 .WW 2 x 6 R-192 x 6 R-19 0.0680.068 sese 1.971.97 1.371.37 0 0 0 0 0 0 0 0 .GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 0 0 0 0 0 0 0 0 11 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 sese 3.483.48 2.922.92 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 sese 8.708.70 17.9617.96 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 0 0 0 0 0 0 0 0 DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 sese 17.4017.40 17.5817.58 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 swsw 3.483.48 2.922.92 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 swsw 8.708.70 17.8617.86 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nwnw 3.483.48 2.922.92 0 0 0 0 135 119 414 347 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 nwnw 8.708.70 26.8726.87 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 nwnw 8.998.99 25.8625.86 0 0 0 0 16 0 146 419 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 CC Metal Roof, Encapsul 0.405Metal Roof, Encapsul 0.405 --1.641.64 1.271.27 129 129 212 164 172 172 282 218 FF Slab on GradeSlab on Grade 0.5820.582 --16.8816.88 0.000.00 129 12 203 0 172 27 456 0 6 c) AED excursion -29 83 Envelope loss/gain 1096 769 1703 1407 12 a) Infiltration 235 70 528 157 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 500 0 Subtotal (lines 6 to 13)1331 1339 2231 1564 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1331 1339 2231 1564 15 Duct loads 15%10%201 134 15%10%337 157 Total room load 1532 1473 2568 1721 Air required (cfm)Air required (cfm)63 63 106 74 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-06 11:00:01Right-Suite® Universal 2019 19.0.21 RSU27939 Page 8...20\Working Drawings\Buchmeyer Residence CO2.rup Calc = MJ8 Front Door faces: SE Buchmeyer Residence CO2Job:Right-J® Worksheet Oct 06, 2020Date:Entire House John TeagardinBy:ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Bath 2 Great Room 2 Exposed wall 5.5 ft 32.0 ft 3 Room height 9.3 heat/coolft 12.3 heat/coolft 4 Room dimensions ft10.0x5.5 ft511.6x1.0 5 Room area 55.0 ft²511.6 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nene 3.483.48 2.922.92 0 0 0 0 45 45 155 130 .DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 nene 17.4017.40 17.5817.58 0 0 0 0 0 0 0 0 .WW 2 x 6 R-192 x 6 R-19 0.0680.068 sese 1.971.97 1.371.37 0 0 0 0 0 0 0 0 .GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 0 0 0 0 0 0 0 0 11 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 sese 3.483.48 2.922.92 0 0 0 0 247 247 860 721 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 sese 8.708.70 17.9617.96 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 0 0 0 0 0 0 0 0 DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 sese 17.4017.40 17.5817.58 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 swsw 3.483.48 2.922.92 0 0 0 0 57 57 199 166 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 swsw 8.708.70 17.8617.86 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nwnw 3.483.48 2.922.92 51 51 179 150 359 266 925 775 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 nwnw 8.708.70 26.8726.87 0 0 0 0 32 0 282 870 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 nwnw 8.998.99 25.8625.86 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 60 0 577 1613 CC Metal Roof, Encapsul 0.405Metal Roof, Encapsul 0.405 --1.641.64 1.271.27 55 55 90 70 567 567 930 718 FF Slab on GradeSlab on Grade 0.5820.582 --16.8816.88 0.000.00 55 6 93 0 512 32 540 0 6 c) AED excursion -5 570 Envelope loss/gain 362 214 4468 5564 12 a) Infiltration 107 32 1482 441 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 4 920 Appliances/other 0 900 Subtotal (lines 6 to 13)469 246 5949 7825 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 469 246 5949 7825 15 Duct loads 15%10%71 25 15%10%898 785 Total room load 540 271 6847 8610 Air required (cfm)Air required (cfm)22 12 283 371 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Oct-06 11:00:01Right-Suite® Universal 2019 19.0.21 RSU27939 Page 9...20\Working Drawings\Buchmeyer Residence CO2.rup Calc = MJ8 Front Door faces: SE Buchmeyer Residence CO2Job:Right-J® Worksheet Oct 06, 2020Date:Entire House John TeagardinBy:ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 1 Room name Bedroom 4 Kitchen 2 Exposed wall 12.5 ft 0 ft 3 Room height 9.3 heat/coolft 12.1 heat/coolft 4 Room dimensions ft158.8x1.0 ft339.8x1.0 5 Room area 158.8 ft²339.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nene 3.483.48 2.922.92 0 0 0 0 55 55 193 162 .DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 nene 17.4017.40 17.5817.58 0 0 0 0 0 0 0 0 .WW 2 x 6 R-192 x 6 R-19 0.0680.068 sese 1.971.97 1.371.37 0 0 0 0 0 0 0 0 .GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 0 0 0 0 0 0 0 0 11 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 sese 3.483.48 2.922.92 117 100 350 293 4 4 14 12 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 sese 8.708.70 17.9617.96 16 16 141 291 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 sese 8.998.99 17.8017.80 0 0 0 0 0 0 0 0 DD Door, mtl fbrgl type 0.600Door, mtl fbrgl type 0.600 sese 17.4017.40 17.5817.58 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 swsw 3.483.48 2.922.92 0 0 0 0 43 43 149 125 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 swsw 8.708.70 17.8617.86 0 0 0 0 0 0 0 0 WW Blk wall, Hardie ext 0.120Blk wall, Hardie ext 0.120 nwnw 3.483.48 2.922.92 0 0 0 0 151 151 526 441 GG Double Pane, Low-E, 0.300Double Pane, Low-E, 0.300 nwnw 8.708.70 26.8726.87 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.310Double Pane, Low-E, 0.310 nwnw 8.998.99 25.8625.86 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 GG Double Pane, Low-E, 0.330Double Pane, Low-E, 0.330 nwnw 9.579.57 26.7526.75 0 0 0 0 0 0 0 0 CC Metal Roof, Encapsul 0.405Metal Roof, Encapsul 0.405 --1.641.64 1.271.27 159 159 260 201 374 374 614 474 FF Slab on GradeSlab on Grade 0.5820.582 --16.8816.88 0.000.00 159 13 211 0 340 0 0 0 6 c) AED excursion -18 -77 Envelope loss/gain 962 767 1496 1137 12 a) Infiltration 244 73 531 158 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 1 230 Appliances/other 0 2000 Subtotal (lines 6 to 13)1206 839 2027 3525 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 12 9 15 11 14 Subtotal 1218 848 2042 3536 15 Duct loads 15%10%184 85 15%10%308 355 Total room load 1402 933 2350 3891 Air required (cfm)Air required (cfm)58 40 97 167 2020-Oct-06 11:00:26 Right-Suite® Universal 2019 19.0.21 RSU27939 Page 1 ...20\Working Drawings\Buchmeyer Residence CO2.rup Calc = MJ8 Front Door faces: SE Buchmeyer Residence CO2Job:Static Pressure and Friction Rate Oct 06, 2020Date:Entire House John TeagardinBy: ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 Project Information Buchmeyer Residence CO2For: 20806 Glades Cut Off Rd, Port St Lucie, FL 34987 Phone: 772-696-3296 Available Static Pressure CoolingHeating (in H2O)(in H2O) 0.700.70External static pressure Pressure losses 00Coil 0.040.04Heat exchanger 0.030.03Supply diffusers 0.030.03Return grilles 0.250.25Filter 00Humidifier 0.030.03Balancing damper 00Other device 0.320.32Available static pressure Total Effective Length ReturnSupply (ft)(ft) 1123Measured length of run-out 5048Measured length of trunk 120200Equivalent length of fittings 181271Total length 452Total effective length Friction Rate CoolingHeating (in/100ft)(in/100ft) OK0.071OK0.071Supply Ducts OK0.071OK0.071Return Ducts Fitting Equivalent Length Details 4X=35, 2A0=35, 11G=5, 11G=5, 11G=5, 11I=10, 11A=20, 11G=5, 11G=5, 11A=20, 11G=5, 11G=5, USR1=45: TotalEL=200 Supply 11A=20, 6M=20, 11G=5, 11G=5, 11G=5, 5A=40, 6CB=25: TotalEL=120Return 2020-Oct-06 11:00:26 Right-Suite® Universal 2019 19.0.21 RSU27939 Page 1 ...20\Working Drawings\Buchmeyer Residence CO2.rup Calc = MJ8 Front Door faces: SE Buchmeyer Residence CO2Job:Duct System Summary Oct 06, 2020Date:Entire House John TeagardinBy: ProCalcs, LLC P.O. Box 882032, Port Saint Lucie, FL 34988 Phone: 772-882-5700 Email: tom@procalcs.net Web: www.ProCalcs.Net License: CAC1815254 RTIN #0105474 Project Information Buchmeyer Residence CO2For: 20806 Glades Cut Off Rd, Port St Lucie, FL 34987 Phone: 772-696-3296 CoolingHeating External static pressure in H2O0.70in H2O0.70 Pressure losses in H2O0.38in H2O0.38 Available static pressure in H2O0.32in H2O0.32 Supply / return available pressure 0.192 / 0.128 in H2O in H2O0.192 / 0.128 Lowest friction rate in/100ft0.071in/100ft0.071 Actual air flow cfm1200cfm1200 Total effective length (TEL) ft452 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st3140.020.2VlFx0x04.00.120120271cBath 2 st2105.016.6VlFx0x04.00.158130304cBath 3 75.06.0VlFx0x06.00.2377401721cBedroom 2 st2105.017.4VlFx0x06.00.1576401484cBedroom 3 st5135.035.1VlFx0x05.00.113400933cBedroom 4 st5135.045.0VlFx0x05.00.107330763cEntry st4115.041.9VlFx0x07.00.1229302153cGreat Room st4115.039.9VlFx0x07.00.1249302153cGreat Room-A st3130.026.8VlFx0x07.00.1229302153cGreat Room-B st3120.023.0VlFx0x07.00.1349302153cGreat Room-C st5135.041.3VlFx0x07.00.1098401945cKitchen st5135.029.7VlFx0x07.00.1178401945cKitchen-A st2105.015.1VlFx0x06.00.1606301473cLaundry st7190.063.8VlFx0x06.00.0765101181cMaster Bath st4115.053.2VlFx0x06.00.1147501742cMaster Bedroom st7200.052.1VlFx0x05.00.076380875cMaster Closet st7210.051.3VlFx0x06.00.073390913cOffice-A st2105.021.5VlFx0x05.00.152390911cPlayroom st4125.059.2VlFx0x07.00.10411102569cSitting Room st7200.070.8VlFx0x04.00.071100233cWC 2020-Oct-06 11:00:26 Right-Suite® Universal 2019 19.0.21 RSU27939 Page 2 ...20\Working Drawings\Buchmeyer Residence CO2.rup Calc = MJ8 Front Door faces: SE Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st7 Peak AVF 0 138 0.071 310 7.4 8x8 RectFbg st6 st3 Peak AVF 0 568 0.104 417 11.7 14x14 RectFbg st1 st4 Peak AVF 0 371 0.104 472 12.0 0x0 VinlFlx st3 st1 Peak AVF 0 568 0.104 531 14.0 0x0 VinlFlx st5 Peak AVF 0 378 0.071 482 12.0 0x0 VinlFlx st2 st6 Peak AVF 0 138 0.071 395 8.0 0x0 VinlFlx st5 st2 Peak AVF 0 558 0.071 522 14.0 0x0 VinlFlx Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb5 0x 00 74 125.4 0.102 377 6.0 x0 0 VlFx rt2 rb6 0x 00 396 123.2 0.104 505 12.0 x0 0 VlFx rt2 rb1 0x 00 174 180.8 0.071 393 9.0 x0 0 VlFx rt4 rb8 0x 00 39 180.6 0.071 200 6.0 x0 0 VlFx rt4 rb2 0x 00 111 175.4 0.073 317 8.0 x0 0 VlFx rt4 rb7 0x 00 302 174.8 0.073 384 12.0 x0 0 VlFx rt4 rb3 0x 00 40 170.1 0.075 205 6.0 x0 0 VlFx rt3 rb4 0x 00 64 166.7 0.077 325 6.0 x0 0 VlFx rt3 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt2 Peak AVF 0 575 0.075 538 14.0 0x0 VinlFlx rrs1 rrs1 Peak AVF 0 1200 0.071 576 16.7 15x20 RectFbg rt1 rt4 Peak AVF 0 625 0.071 448 16.0 0x0 VinlFlx rrs1 rt3 Peak AVF 0 104 0.075 298 8.0 0x0 VinlFlx rt2 rt1 Peak AVF 0 1200 0.071 533 16.1 18x18 RectFbg