Loading...
HomeMy WebLinkAboutAPPROVED Design Pressure Report (Falcetta) - Master Craft Aluminum Products Property Information Building Information Owner: Falcetta Wind Zone: 160 MPH. Address: 37 Ecuador Way Exposure Category: B Ft Pierce,Fl 34951 Minimum Building Dimension: 24 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 52 62 7 30.8 -33.5 2 Int 26 38 7 32.5 -35.2 3 Int 26 38 7 32.5 -35.2 4 End 74 62 7 30.0 -38.6 5 Int 52 55 7 31.0 -33.8 6 Int 52 55 7 31.0 -33.8 7 Int 27 62 7 32.2 -34.9 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1