Loading...
HomeMy WebLinkAboutSPECS-3KOHLER• Models: 20RCA(L) Multi -Fuel 09001 Standard Features � KOHLER. • RDC2 Controller NA110NALLY R[GI EReg The Kohler® Advantage • High Quality Power Kohler home generators provide advanced voltage and frequency regulation along with ultra -low levels of harmonic distortion for excellent generator power quality to protect your valuable electronics. • Extraordinary Reliability Kohler is known for extraordinary reliability and performance and backs that up with a premium 5-year or 2000 hour limited warranty. • Powerful Performance Exclusive Powerboost" technology provides excellent starting power. § • Aluminum Enclosure o Attractive aluminum enclosure allows installation as close as 18 inches from your home or small business. t o Enclosure panels can be removed without tools to allow easy access for maintenance and service. Generator LPG/Natural Gas o One digital controller manages both the generator set and transfer switch functions (with optional Model RXT). o Electronic speed control responds quickly to varying demand. o OnCue(e Plus Generator Management System for remote monitoring is included with the generator. • Kohler Command PRO Engine Features o Kohler Command PRO® OHV engine with hydraulic valve lifters for reliable performance without routine valve adjustment or lengthy break-in requirements. • Designed for Easy Installation o Sturdy aluminum base can be mounted on gravel or a concrete mounting pad. o Fuel and electrical connections through the enclosure wall eliminate the need for stub -ups through the base. o Customer connection terminal block located near the controller allows easy access for field wiring. o Designed for outdoor installation only. • Certifications o Meets emission regulations for U.S. Environmental Protection Agency (EPA) with both natural gas and LPG. o UL 2200/cUL listed (60 Hz model). o CSA certification available (60 Hz model). o Accepted by the Massachusetts Board of Registration of Plumbers and Gas Fitters. o Meets 181 mph wind rating. • Approved for stationary standby applications in locations served by a reliable utility source. • 2oRCAL models packaged with a Model RXT automatic transfer switch are available. See page 4 and the Model RXT ATS specification sheet. • Warranty 0 5-year /2000 hour limited warranty for on -grid (standby) applications in locations served by a reliable utility source. Natural Gas Line Circuit LPG Breaker Alternator Voltage Phase Hz kW/kVA Amps kW/kVA Amps Amps Poles 2F7 120/240 1 60 18/18 75 20/20 83 100 2 120/208 3 60 17/21 58 17/21 58 70 3 2127 120/240 3 60 17/21 51 17/21 51 60 3 277/480 3 60 17/21 26 17/21 26 30 3 Note: The line circuit breaker is automatically selected based on the generator set model and voltage configuration. RATINGS: Stantlbv ratings agplvto installations served bvareliableutilitvsource. All sinole-phase units are rated at l.0 powerfaclor. The slandbv retina is seat A52]69, and DIN 62]1. GENERAL eralure increaseabovet6°C (60°�. any obligation or liability whatsoever. Contact your § Ghecktheappliancemanufacturer's specificationsfor actual power requirements. Consults Kohler% Power Systems professionalfo calculafeyour exact residential powersystem requirements. i Meets NPPA guitlelines for l8 inch clearance fo combustible materials. Check state and local codes for minimum distance required framaslructure. G4-2]2 (20RCA) 12/16 Alternator Specifications Alternator Specifications Alternator Features Engine Cli • Digital voltage regulator with -_1.0% no-load to full -load RMS regulation. • Rotating -field alternator with static exciter for excellent load response. • Total harmonic distortion (THD) from no load to full load with a linear load is less than 5%. Application Data Exhaust Engine Specifications Exhaust System Manufacturer Kohler Engine: model, type CHI GOO 4-Cycle Cylinder arrangement V-2 Displacement, cm3 (cu. in.) 999 (61) Bore and stroke, Gun(in.) 90 x 78.5 (3.54 x 3.1) Compression ratio 8.8:1 Main bearings: quantity, type 2, Parent Material Rated RPM 60 Hz 3600 Max. engine power at rated rpm, kW (HP) LPG, 60 Hz 23.0 (30.9) Natural gas, 60 Hz 20.2 (27.1) Cylinder head material Aluminum Valve material Steel/Stellite® Piston type and material Aluminum Alloy Crankshaft material Heat Treated, Ductile Iron Governor: type Electronic Frequency regulation, no load to full load Isochronous Frequency regulation, steady state ±0.5% Air cleaner type Dry Engine Electrical Engine Electrical System Ignition system Electronic, Capacitive Discharge Starter motor rated voltage (DC) 12 Battery (purchased separately): Ground Negative Volts (DC) 12 Battery quantity 1 Recommended cold cranking amps: (CCA) rating for -18°C (0°F) 500 Group size 51 Exhaust temperature exiting the enclosure at rated kW, dry, °C (OF) 260 (500) Lubrication Lubricating System Type Full Pressure Oil capacity (with filter), L (qt.) 1.9 (2.0) Oil filter: quantity, type 1, Cartridge Oil cooler Integral Fuel Pipe Size Minimum Gas Pipe Size Battery (purchased separately): Ground Negative Volts (DC) 12 Battery quantity 1 Recommended cold cranking amps: (CCA) rating for -18°C (0°F) 500 Group size 51 Exhaust System Lubrication Lubricating System Type Full Pressure Oil capacity (with filter), L (qt.) 1.9 (2.0) Oil filter: quantity, type 1, Cartridge Oil cooler Integral Fuel Pipe Size Minimum Gas Pipe Size Recommendation, in. NPT Pipe Length, Natural Gas LPG m (tt.) 281,000 Btu/hr. 340,000 Btu/hr. 8 (25) 1 3/4 15 (50) 1 1 30 (100) 1 1/4 1 46 (150) 1 1/4 1 1/4 61 (200) 1 1/4 1 1/4 G4-2]2 t206GA) 12/1a Fuel Requirements Fuel Fuel types Natural Gas or LPG Fuel supply inlet 1/2 NPT Fuel supply pressure, kPa (in. H20): Natural gas 0.9-2.7 (3.5-11) LP 1.7-2.7 (7-11) Fuel Composition Limits* Nat. Gas LPG Methane, % by volume (minimum) 90 min. — Ethane, % by volume (maximum) 4.0 max. — Propane, % by volume 1.0 max. 85 min. Propene, % by volume (maximum) 0.1 max. 6.0 max. C4 and higher, % by volume 0.3 max. 2.5 max. Sulfur, ppm mass (maximum) 25 max. Lower heatingQ value, MJ/m3 (Btu/fts), (minimum) 33.2 (890) 84.2 (2260) * Contact your local distributor for suitability and rating derates based on fuel compositions outside these limits. Vaeg9e: BOO Hz o RDC2 The RDC2 controller provides integrated control for the generator set, Kohler® Model RXT transfer switch, programmable interface module (PIM), and load shed kit. RDC2 Controller Features • Membrane keypad: o OFF, AUTO, and RUN pushbuttons o Select and arrow buttons for access to system configuration and adjustment menus • LED indicators for OFF, AUTO, and RUN modes • LED indicators for utility power and generator set source availability and ATS position (Model R)(T transfer switch required) • LCD display: o Two lines x 16 characters per line o Backlit display with adjustable contrast for excellent visibility in all lighting conditions • Scrolling system status display: o Generator set status o Voltage and frequency o Engine temperature o Oil pressure o Battery voltage o Engine runtime hours Operation Requirements Fuel Consumption, m3/hr. (cfh) @ 60Hz Load Natural Gas LPG 100 8.0 (281) 3.9 (136) 75 6.9 (243) 3.1 (109) 50 4.6 (161) 2.3 (82) 25 3.6 (127) 1.7 (59) Exercise 2.0 (71) 1.0 (35) Nominal fuel rating: Natural gas: 37 MJ/m3 (1000 Btu/ft.3) LPG: 93 MJ/m3 (2500 Btu/11.3) LPG conversion factors: 8.58 ft.3 = 1 Ib. 0.535 m3 = 1 kg 36.39 ft 3 = 1 gal. Controller • Programmable exerciser can be set to start automatically on any future day and time, and run every week or every two weeks • Date and time displays • Smart engine cooldown senses engine temperature • Digital isochronous governor maintains steady-state speed at all loads • Digital voltage regulation: ±1.0% RMS no-load to full -load . Automatic start with programmed cranking cycle • Exercise modes: Unloaded weekly o exercise with complete system diagnostics o Unloaded full -speed exercise o Loaded full -speed exercise (Model RXT ATS required) • Front -access mini USB connector for StteTech" or USB Utility connection • Integral Ethernet connector for KohlerO OnCue® Plus • Built-in 2.5 amp battery charger • Remote two -wire start/stop capability for optional connection of a Model RDT transfer switch • Diagnostic messages: Displays diagnostic messages for the engine, generator, Model RXT transfer switch, programmable interface module (PIM), and load management device. • Maintenance reminders • System settings; o System voltage, frequency, and phase o Voltage adjustment o Measurement system, English or metric • ATS status (Model RXT ATS required): o Source availability o ATS position (normal/utility or emergency/generator) o Source voltage and frequency • ATS control (Model RXT ATS required): o Source voltage and frequency settings o Engine start time delay o Transfer time delays o Voltage calibration o Fixed pickup and dropout settings • Programmable Interface Module (PIM) status displays: o Input status (active/inactive) o Output status (active/inactive) • Load control menus: o Load status o Test function G4-272 (20RCA) 12(10 KOHLER, Generator Set Standard Features • Battery cables • EPA certified fuel system • Aluminum sound enclosure • Critical silencer • Field -connection terminal block • Fuel solenoid valve and secondary regulator • Line circuit breaker • Multi -fuel system, LPG/natural gas, field -convertible • Oil drain extension with shutoff valve • OnCueO Plus Generator Management System • Premium 5-year limited warranty • RDC2 generator set/ATS controller • Rodent -resistant construction • Sound -deadening, flame-retardant foam per UL 94, class HF-1 Available Options Approvals and Listings ❑ GSA approval Communication Accessories ❑ OnCueO Plus Wireless Generator Management System Concrete Mounting Pads ❑ Concrete mounting pad, 3 in. thick ❑ Concrete mounting pad, 4 in. thick (recommended for storm -prone areas) Electrical Accessories ❑ Battery ❑ Battery heater, 120VAC ❑ Battery heater, 240VAC ❑ Cold weather package, 120VAG ❑ Cold weather package, 240VAC ❑ Emergency stop kit ❑ PowerSync0 Automatic Paralleling Module (APM) (single phase only; parallel two 20kW residential generator sets with the RDC2 controller) ❑ Programmable interface module (PIM) (provides 2 digital inputs and 6 relay outputs) Fuel System Accessories ❑ Flexible fuel line (included on QS models) ❑ Carburetor heater, 120 VAC ❑ Carburetor heater, 240 VAC Carburetor heater is recommended for reliable starting at temperatures below 0°C (32°F ) Literature ❑ General maintenance literature kit ❑ Overhaul literature kit ❑ Production literature kit Maintenance ❑ Maintenance kit (includes air filter, oil, oil filter, and spark plugs) KOHLER CO., Kohler, Wisconsin 53044 USA Phone 920-457-4441, Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444 KOHLERPower.com Automatic Transfer Switches and Accessories ❑ Model RDT ATS ❑ Model RXT ATS ❑ Model RXT ATS with combined interface/load management board ❑ Load shed kit for RXT or ROT ❑ Power relay modules (use up to 4 relay modules for each load management device) ❑ Other Kohler® ATS 20RCAL Model Packages ❑ 20RCAL with 100 amp RXT with 16-space load center and NEMA 1 steel enclosure for indoor installation ❑ 20RCAL with 200 amp service entrance -rated Model RXT with combined interface/load management board and corrosion -resistant NEMA3R aluminum enclosure Generator Set Dimensions and Weights Generator Set Size, L x W x H: 1193 x 666 x 817 mm (47 x 26.2 x 32.2 in.) Shipping Weights: 20RCA Generator Set: 252 kg (555 lb.) CAL with 100 A RXT ATS w/LC 277 kg (611 lbs) CAL with 200 A RXT SE ATS: 272 kg (600 lb.) r- L NOTE: Dimensions are provided for reference only antl shoultl not be used for planning Installallon. Contact your local disVibulor for more detailed information. DISTRIBUTED BY: G9-2]2 (20RCA) 12/18