HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performancel%ft'Md
Project Name: RESENDIZ RESIDENCE
Builder Name:
MAY 19 2020
Street: 4413 PRESSLER LANE
City, State,
Permit Office: ST LUCIE COUNTY
Perm
Zip: FORT PIERCE, FL,
Permit Number:
5tiLuttincie Countyent
Owner: ARTEMIO RESENDIZ
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County. St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (2701.6 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 2300.20 ft2
b. Frame - Wood, Adjacent
R=13.0 401.33 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. NIA
R= ft2
5. Is this a worst case? No
10. Ceiling Types (2406.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2406.00 ft2
6. Conditioned floor area above grade (ft2) 2406
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(296.0 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Garage
6 200
a. U-Factor: Sgl, U=0.65 200.00 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.65 96.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.30
a. Central Unit
46.5 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
34.0 COPA.00
SHGC:
Area Weighted Average Overhang Depth: 6.399 ft.
Area Weighted Average SHGC: 0.266
14. Hot water systems
8. Floor Types (2406.0 sqft.).) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 2406.00 ft2
b. Conservation features
EF: 0.980
b. NIA R= ft2
None
c. NIA R= ft2
15. Credits
None
Glass/Floor Area: 0.123 Total Proposed Modified Loads: 79.04
PASS
Total Baseline Loads: 81.53
1 hereby certify that the plans and specifications covered by
Review of the plans and
1110 ST9?t�
this calculation are in compliance with the Florida Energy
specifications covered by this
©
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
J'
DATE: 4-9-2020
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
G'OD Nrg'i�°
OWNER/AGENT
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
4/8/2020 11:56 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
RESENDIZ RESIDENCE
Bedrooms:
4
Address Type:
Street Address
Building Type:
User
Conditioned Area:
2406
Lot #
Owner Name:
ARTEMIO RESENDIZ
Total Stories:
1
Block/Subdivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
Rotate Angle:
0
Street:
4413 PRESSLER LANE
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
No
County.
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan:
No
City, State, Zip:
FORT PIERCE,
Family Type:
Single-family
FL,
New/Ebsting:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2406
22375.8
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
M TOILET
24
223.2 No
0
1
Yes
Yes
Yes
2
M BATH
174
1618.2 No
0
1
Yes
Yes
Yes
3
MASTER BEDROO
260
2418 No
0
1
1
Yes
Yes
Yes
4
M WIC
168
1562.4 No
0
1
Yes
Yes
Yes
5
UTILITY
84
781.2 No
0
1
No
Yes
Yes
6
M HALL
40
372 No
0
1
No
Yes
Yes
7
DINING
126
1171.8 No
0
1
Yes
Yes
Yes
8
KITCHEN
252
2343.6 Yes
0
1
No
Yes
Yes
9
PANTRY
98
911.4 No
0
1
Yes
Yes
Yes
10
FOYER
81
753.3 No
0
1
Yes
Yes
Yes
11
CLST 4
20
186 No
0
1
No
Yes
Yes
12
BEDROOM 4
176
1636.8 No
0
1
1
Yes
Yes
Yes
13
LIVING ROOM
323
3003.9 No
0
1
Yes
Yes
Yes
14
HALLWAY
72
669.6 No
0
1
Yes
Yes
Yes
15
BEDROOM 3
169
1571.7 No
0
1
1
Yes
Yes
Yes
16
CLST 3
26
241.8 No
0
1
Yes
Yes
Yes
17
BATH 2
56
520.8 No
0
1
Yes
Yes
Yes
18
SINKS 2
48
446.4 No
0
1
No
Yes
Yes
19
BEDROOM 2
191
1776.3 No
0
1
1
Yes
Yes
Yes
20
CLST 2
18
167.4 No
0
1
Yes
- Yes
Yes
4/8/202011:56•AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
1 Slab -On -Grade Edge Insulation
M TOILET
loft
0
24 ft2
____
1
0
0
2 Slab -On -Grade Edge Insulation
M BATH
19 ft
0
174 ft2
---_
1
0
0
3 Slab -On -Grade Edge Insulation
MASTER BEDRO
28 ft
0
260 ft2
____
1
0
0
4 Slab -On -Grade Edge Insulation
M W IC
12 ft
0
168 ft2
___-
1
0
0
5 Slab -On -Grade Edge Insulation
UTILITY
1 ft
0
84 ft2
____
1
0
0
6 Slab -On -Grade Edge Insulation
M HALL
1 ft
0
40 ft2
____
1
0
0
7 Slab -On -Grade Edge Insulation
DINING
22 It
0
126 ft2
____
1
0
0
8 Slab -On -Grade Edge Insulation
KITCHEN
1 ft
0
252 ft2
___-
1
0
0
9 Slab -On -Grade Edge Insulation
PANTRY
14 ft
0
98 ft2
____
1
0
0
10Siab-On-Grade Edge Insulation
FOYER
9 ft
0
81 ftz
____
1
0
0
11SIab-On-Grade Edge Insulation
CLST 4
1 ft
0
20 ft2
____
1
0
0
12SIab-On-Grade Edge Insulation
BEDROOM 4
28 ft
0
176 ft2
___-
1
0
0
13SIab-On-Grade Edge Insulation
LIVING ROOM
19 ft
0
323 ft2
____
1
0
0
14SIab-On-Grade Edge Insulation
HALLWAY
1 ft
0
72 ft2
----
1
0
0
15SIab-On-Grade Edge Insulation
BEDROOM 3
26 ft
0
169 ft2
____
1
0
0
16SIab-On-Grade Edge Insulation
CLST 3
2 ft
0
26 ft2
____
1
0
0
17SIab-On-Grade Edge Insulation
BATH 2
8 ft
0
56 ft2
___-
1
0
0
18SIab-On-Grade Edge Insulation
SINKS 2
1 ft
0
48 ft2
____
1
0
0
19Slab-On-Grade Edge Insulation
BEDROOM 2
32.3 ft
0
191 ft2
____
1
0
0
20SIab-On-Grade Edge Insulation
CLST 2
11 ft
0
18 ft2
-_-_
1
0
0
ROOF
/
Roof
Gable
Roof
Red
Solar SA Emitt
Emitt
Deck
Pitch
V/ # Type Materials
Area
Area
Color
Barr
Absor. Tested
Tested
Insul.
(deg)
1 Hip
Metal 2691 ft2
0 ft2
Light
N
0.6 No 0.9
No
0
26.6
.
ATTIC
/
v
# Type
Ventilation
Vent Ratio (1
in)
Area
RBS IRCC
1 Full attic
Vented
150
2406 ft2
N N
4/8/2020 11:56 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) M TOILET
30
Blown
241?
0.1
Wood
2
Under Attic (Vented) M BATH
30
Blown
174 112
0.1
Wood
3
Under Attic (Vented) MASTER BEDRO
30
Blown
260 ft2
0.1
Wood
4
Under Attic (Vented) M W IC
30
Blown
168 ft2
0.1
Wood
5
Under Attic (Vented) UTILITY
30
Blown
84 ft2
0.1
Wood
6
Under Attic (Vented) M HALL
30
Blown
40 ft2
0.1
Wood
7
Under Attic (Vented) DINING
30
Blown
126ft2
0.1
Wood
8
Under Attic (Vented) KITCHEN
30
Blown
252IF
0.1
Wood
9
Under Attic (Vented) PANTRY
30
Blown
98 112
0.1
Wood
10
Under Attic (Vented) FOYER
30
Blown
81112
0.1
Wood
11
Under Attic (Vented) CLST 4
30
Blown
20 ft2
0.1
Wood
12
Under Attic (Vented) BEDROOM 4
30
Blown
176 ft2
0.1
Wood
13
Under Attic (Vented) LIVING ROOM
30
Blown
323 ft2
0.1
Wood
14
Under Attic (Vented) HALLWAY
30
Blown
721?
0.1
Wood
15
Under Attic (Vented) BEDROOM 3
30
Blown
169 ft2
0.1
Wood
16
Under Attic (Vented) CLST 3
30
Blown
26 ft2
0.1
Wood
17
Under Attic (Vented) BATH 2
30
Blown
56 ft2
0.1
Wood
18
Under Attic (Vented) SINKS 2
30
Blown
48 ft2
0.1
Wood
19
Under Attic (Vented) BEDROOM 2
30
Blown
191 ft2
0.1
Wood
20
Under Attic (Vented) CLST 2
30
Blown
18 ft2
0.1
Wood
WALLS
Adjacent Space
Cavity
Width
Height
Sheathing Framing Solar
Below
1
S
Exterior Concrete Block - Ext Insul M TOILET
4.1
6
0 9
4
56.0 112
0
0
0.6
0
_ 2
W
Exterior Concrete Block - Ext InsulM TOILET
4.1
4
0 9
4
37.3 f?
0
0
0.6
0
3
S
Exterior Concrete Block - Ext Insul M BATH
4.1
12
0 9
4
112.0 ft2
0
0
0.6
0
- 4
W
Exterior Concrete Block - Ext Insul M BATH
4.1
7
0 9
4
65.3 ft2
0
0
0.6
0
5
N
Exterior - Concrete Block - Ext InstFAASTER BE
4.1
14
0 10 ,
4
144.7 ft2
0
0
0.6
0
6
W
Exterior Concrete Block - Ext InsMASTER BE
4.1
14
0 10
4
144.7 ft2
0
0
0.6
0
7
S
Exterior Concrete Block- Ext Insul M W IC
4.1
12
0 9
4
112.0 112
0
0
0.6
0
8
E
Garage Frame - Wood M W IC
13
14
0 9
4
130.7 ft2
0
0.1
0.6
0
_ 9
E
Garage Frame - Wood UTILITY
13
7
0 9
4
65.3 112
0
0.1
0.6
0
10
E
Garage Frame - Wood M HALL
13
4
0 9
4
37.3 ft2
0
0.1
0.6
0
11
N
Exterior Concrete Block - Ext Insul DINING
4.1
8
0 9
4
74.7 ft2
0
0
0.6
0
12
W
Exterior Concrete Block - Ext Insul DINING
4.1
14
0 9
4
130.7 ft2
0
0
0.6
0
13
S
Garage Frame - Wood KITCHEN
13
11
0 9
4
102.7 ft2
0
0.1
0.6
0
14
E
Exterior Concrete Block - Ext Insul PANTRY
4.1
14
0 9
4
130.7 ft2
0
0
0.6
0
15
S
Garage Frame - Wood PANTRY
13
7
0 9
4
65.3 ft2
0
0.1
0.6
0
16
E
Exterior Concrete Block - Ext Insul FOYER
4.1
9
0 9
4
84.0 ft2
0
0
0.6
0
17
N
Exterior Concrete Block - Ext InsMEDROOM 4
4.1
9
0 9
4
84.0 ft2
0
0
0.6
0
18
E
Exterior Concrete Block - Ext InstBEDROOM 4
4.1
14
0 9
4
130.7 ft2
0
0
0.6
0
19
S
Exterior Concrete Block - Ext InstBEDROOM 4
4.1
5
0 9
4
46.7 1`12
0
0
0.6
0
20
W
Exterior Concrete Block - Ext InsdilVING ROO
4.1
19
0 10
4
196.3 ft2
0
0
0.6
0
4/8/2020 11:56 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing
Solar
Below
Space
Ft n
Area
AhSorn
21
S
Exterior
Concrete Block - Ext InsuIHALLW AY
4.1 1
0
9 4
9.3 ft2
0
0
0.6
0
_ 22
N
Exterior
Concrete Block - Ext InstBEDROOM 3
4.1 13
0
9 4
121.3 ft2
0
0
0.6
0
_ 23
E
Exterior
Concrete Block - Ext InstBEDROOM 3
4.1 13
0
9 4
121.3 ft2
0
0
0.6
0
24
N
Exterior
Concrete Block - Ext Insul CLST 3
4.1 2
0
9 4
18.7 ft2
0
0
0.6
0
25
N
Exterior
Concrete Block - Ext Insul BATH 2
4.1 8
0
9 4
74.7 ft2
0
0
0.6
0
26
N
Exterior
Concrete Block - Ext InsiBEDROOM 2
4.1 13
4
9 4
124.4 ft2
0
0
0.6
0
27
S
Exterior
Concrete Block - Ext InstSEDROOM 2
4.1 4
0
9 4
37.3 ft2
0
0
0.6
0
28
W
Exterior
Concrete Block - Ext InsddEDROOM 2
4.1 15
1
9 4
140.8 ft2
0
0
0.6
0
29
S
Exterior
Concrete Block - Ext Insul CLST 2
4.1 9
0
9 _4
84.0 ft2
0
0
0.6
0
30
W
Exterior
Concrete Block - Ext Insul CLST 2
4.1 2
0
9 4
18.7 ft2
0
0
0.6
0
WINDOWS
Orientation shown is the entered, Proposed
orientation.
/
Wall
Overhang
V
#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
S
3
Metal Low-E Single Yes
0.65 0.25
N
12.0 ft2
2 ft 0 in
1 ft 4 in
None
None
2
W
4
Metal Low-E Single Yes
0.65 0.25
N
12.0 ft2
2 ft 0 in
1 ft 4 in
None
None
3
W
6
Metal Low-E Single Yes
0.65 0.25
N
k 30.0 ft2
2 ft 0 in
1 ft 4 in
None
None
4
W
12
Metal Low-E Single Yes
0.65 0.25
N
40.0 ft2
2 ft 0 in
1 ft 4 in
None
None
5
E
14
Metal Low-E Single Yes
0.65 0.25
N
4.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
6
E
16
Metal Low-E Single Yes
0.65 0.3
N
48.0 ft2
2 ft 0 in
1 ft 4 in
None
None
7
E
18
Metal Low-E Single Yes
0.65 0.25
N
18.0 ft2
2 ft 0 in
1 ft 4 in
None
None
8
W
20
Metal Low-E Single Yes
0.65 0.25
N
45.0 ft2
16 ft 0 in
1 ft 4 in
None
None
9
W
20 ,
Metal Low-E Single Yes
0.65 0.3
N
48.0 ft2
16 ft 0 in
1 ft 4 in
None
None
10
E
23
Metal Low-E Single Yes
0.65 0.25
N
18.0 ft2
2 ft 0 in
1 ft 4 in
None
None
11
N
25
Metal Low-E Single Yes
0.65 0.25
N
6.0 ft2
2 ft 0 in
1 ft 4 in
None
None
12
W
28
Metal Low-E Single Yes
0.65 0.25
N
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
600 ft2 600 ft2
1+1 ft
9 ft
13
INFILTRATION
# Scope
Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse
Proposed ACH(50) .000414 2610.5 143.31
269.52
.1522
7
418/202011:56 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Strip Heat/
None
COP:1
34 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit!
Split
Single SEER: 16
46.5 kBtu/hr 1395 cfm
0.8
1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric None
Garage
0.98 50 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector
Model
# Area
Volume
FEF
None None
ft2
DUCTS
---- Supply ----
---- Return ----
Air
CFM 25
CFM25
HVAC #
v/ # Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT QN
RLF
Heat Cool
1 Attic 6 200 ft2
Attic
20 ft2 Default Leakage
Garage
(Default) c(Default) c
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
CoolingJan Feb Mar
HeatinJan Feb Mar
_
Apr
Ma X Jun X Jul
j Jun r j Jul
II Ma
jjX� Au
(] AuE
[Xj Se
] SeP
JA
Oct
Oct
Nov
Nov
Dec
Dec
Ventin Jan Feb Mar
A r
May Jun Jul
l
[[ ] Aug
j Se
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2 3
4 5 6
7
8
9
10
11
12
Cooling (W D) AM 78
78 78
78 78 78
78
78
80
80
80
80
PM 80
80 80
80 78 78
78
78
78
78
78
78
Cooling (W EH) AM 78
78 78
78 78 78
78
78
80
80
80
80
PM 80
80 80
80 78 78
78
78
78
78
78
78
Heating (W D) AM 65
65 65
65 65 65
65
68
68
68
68
68
PM 68
68 68
68 68 68
68
68
68
68
68
68
Heating (WEH) AM 65
65 65
65 65 65
65
68
68
68
68
68
PM 68
68 68
68 68 68
68
68
68
68
68
68
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
M TOILET
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M BATH
Default(8lbs/sq.ft.
ft2
ft
0.3
MASTER BEDROO
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M W IC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
UTILITY
Default(8lbs/sq.ft.
ft2
ft
0.3
M HALL
Default(8 Ibs/sq.ft.
ft2
ft
0.3
DINING
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
4/8/2020 11:56 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 lbs/sq.ft.
ft2
ft
0.3
PANTRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FOYER
Default(8 Ibs/sq.ft,
ft2
ft
0.3
CLST 4
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 4
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LIVING ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALLWAY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 3
Default(8 Ibs/sq.ft.
ft2
ft -�
0.3
CLST 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
SINKS 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/s .ft.
ft2
ft
0.3
CLST 2
4/8/2020 11:56 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA "ec'el ft
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIAP SAY 1 �74z0
ermltr,.._
t. GUc/e ePdrtme
Project Name: RESENDIZ RESIDENCE Builder Name: n
County
Street: 4413 PRESSLER LANE Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Y
U
Owner: ARTEMIO RESENDIZ Jurisdiction: ST LUCIE COUNTY
w
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceilinglattic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring an
J
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind Diping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of [CC-400.
4/8/2020 11:57 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location Garage
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
4
13. Cooling system: Capacity
46.5
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
2406
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.650
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.266
14. Heating system: Capacity
34.0
c) Area
7c.
296.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor: (weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.98
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
13.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11 a.
30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11 d.
No
e) Multizone heating credit
f) Programmable thermostat
No
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: (4Date: S 1 121�20
Address of New Home: 4413 PRESSLER LANE City/FL Zip: FORT PIERCE, FL
4/8/2020 11:57:31 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1