Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Energy Code
FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performancel%ft'Md Project Name: RESENDIZ RESIDENCE Builder Name: MAY 19 2020 Street: 4413 PRESSLER LANE City, State, Permit Office: ST LUCIE COUNTY Perm Zip: FORT PIERCE, FL, Permit Number: 5tiLuttincie Countyent Owner: ARTEMIO RESENDIZ Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County. St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2701.6 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 2300.20 ft2 b. Frame - Wood, Adjacent R=13.0 401.33 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. NIA R= ft2 5. Is this a worst case? No 10. Ceiling Types (2406.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 2406.00 ft2 6. Conditioned floor area above grade (ft2) 2406 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(296.0 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 200 a. U-Factor: Sgl, U=0.65 200.00 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 96.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 46.5 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 34.0 COPA.00 SHGC: Area Weighted Average Overhang Depth: 6.399 ft. Area Weighted Average SHGC: 0.266 14. Hot water systems 8. Floor Types (2406.0 sqft.).) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 2406.00 ft2 b. Conservation features EF: 0.980 b. NIA R= ft2 None c. NIA R= ft2 15. Credits None Glass/Floor Area: 0.123 Total Proposed Modified Loads: 79.04 PASS Total Baseline Loads: 81.53 1 hereby certify that the plans and specifications covered by Review of the plans and 1110 ST9?t� this calculation are in compliance with the Florida Energy specifications covered by this © Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed J' DATE: 4-9-2020 this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. G'OD Nrg'i�° OWNER/AGENT BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 4/8/2020 11:56 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: RESENDIZ RESIDENCE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2406 Lot # Owner Name: ARTEMIO RESENDIZ Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 4413 PRESSLER LANE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County. St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Ebsting: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2406 22375.8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 M TOILET 24 223.2 No 0 1 Yes Yes Yes 2 M BATH 174 1618.2 No 0 1 Yes Yes Yes 3 MASTER BEDROO 260 2418 No 0 1 1 Yes Yes Yes 4 M WIC 168 1562.4 No 0 1 Yes Yes Yes 5 UTILITY 84 781.2 No 0 1 No Yes Yes 6 M HALL 40 372 No 0 1 No Yes Yes 7 DINING 126 1171.8 No 0 1 Yes Yes Yes 8 KITCHEN 252 2343.6 Yes 0 1 No Yes Yes 9 PANTRY 98 911.4 No 0 1 Yes Yes Yes 10 FOYER 81 753.3 No 0 1 Yes Yes Yes 11 CLST 4 20 186 No 0 1 No Yes Yes 12 BEDROOM 4 176 1636.8 No 0 1 1 Yes Yes Yes 13 LIVING ROOM 323 3003.9 No 0 1 Yes Yes Yes 14 HALLWAY 72 669.6 No 0 1 Yes Yes Yes 15 BEDROOM 3 169 1571.7 No 0 1 1 Yes Yes Yes 16 CLST 3 26 241.8 No 0 1 Yes Yes Yes 17 BATH 2 56 520.8 No 0 1 Yes Yes Yes 18 SINKS 2 48 446.4 No 0 1 No Yes Yes 19 BEDROOM 2 191 1776.3 No 0 1 1 Yes Yes Yes 20 CLST 2 18 167.4 No 0 1 Yes - Yes Yes 4/8/202011:56•AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation M TOILET loft 0 24 ft2 ____ 1 0 0 2 Slab -On -Grade Edge Insulation M BATH 19 ft 0 174 ft2 ---_ 1 0 0 3 Slab -On -Grade Edge Insulation MASTER BEDRO 28 ft 0 260 ft2 ____ 1 0 0 4 Slab -On -Grade Edge Insulation M W IC 12 ft 0 168 ft2 ___- 1 0 0 5 Slab -On -Grade Edge Insulation UTILITY 1 ft 0 84 ft2 ____ 1 0 0 6 Slab -On -Grade Edge Insulation M HALL 1 ft 0 40 ft2 ____ 1 0 0 7 Slab -On -Grade Edge Insulation DINING 22 It 0 126 ft2 ____ 1 0 0 8 Slab -On -Grade Edge Insulation KITCHEN 1 ft 0 252 ft2 ___- 1 0 0 9 Slab -On -Grade Edge Insulation PANTRY 14 ft 0 98 ft2 ____ 1 0 0 10Siab-On-Grade Edge Insulation FOYER 9 ft 0 81 ftz ____ 1 0 0 11SIab-On-Grade Edge Insulation CLST 4 1 ft 0 20 ft2 ____ 1 0 0 12SIab-On-Grade Edge Insulation BEDROOM 4 28 ft 0 176 ft2 ___- 1 0 0 13SIab-On-Grade Edge Insulation LIVING ROOM 19 ft 0 323 ft2 ____ 1 0 0 14SIab-On-Grade Edge Insulation HALLWAY 1 ft 0 72 ft2 ---- 1 0 0 15SIab-On-Grade Edge Insulation BEDROOM 3 26 ft 0 169 ft2 ____ 1 0 0 16SIab-On-Grade Edge Insulation CLST 3 2 ft 0 26 ft2 ____ 1 0 0 17SIab-On-Grade Edge Insulation BATH 2 8 ft 0 56 ft2 ___- 1 0 0 18SIab-On-Grade Edge Insulation SINKS 2 1 ft 0 48 ft2 ____ 1 0 0 19Slab-On-Grade Edge Insulation BEDROOM 2 32.3 ft 0 191 ft2 ____ 1 0 0 20SIab-On-Grade Edge Insulation CLST 2 11 ft 0 18 ft2 -_-_ 1 0 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V/ # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 2691 ft2 0 ft2 Light N 0.6 No 0.9 No 0 26.6 . ATTIC / v # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2406 ft2 N N 4/8/2020 11:56 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) M TOILET 30 Blown 241? 0.1 Wood 2 Under Attic (Vented) M BATH 30 Blown 174 112 0.1 Wood 3 Under Attic (Vented) MASTER BEDRO 30 Blown 260 ft2 0.1 Wood 4 Under Attic (Vented) M W IC 30 Blown 168 ft2 0.1 Wood 5 Under Attic (Vented) UTILITY 30 Blown 84 ft2 0.1 Wood 6 Under Attic (Vented) M HALL 30 Blown 40 ft2 0.1 Wood 7 Under Attic (Vented) DINING 30 Blown 126ft2 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blown 252IF 0.1 Wood 9 Under Attic (Vented) PANTRY 30 Blown 98 112 0.1 Wood 10 Under Attic (Vented) FOYER 30 Blown 81112 0.1 Wood 11 Under Attic (Vented) CLST 4 30 Blown 20 ft2 0.1 Wood 12 Under Attic (Vented) BEDROOM 4 30 Blown 176 ft2 0.1 Wood 13 Under Attic (Vented) LIVING ROOM 30 Blown 323 ft2 0.1 Wood 14 Under Attic (Vented) HALLWAY 30 Blown 721? 0.1 Wood 15 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood 16 Under Attic (Vented) CLST 3 30 Blown 26 ft2 0.1 Wood 17 Under Attic (Vented) BATH 2 30 Blown 56 ft2 0.1 Wood 18 Under Attic (Vented) SINKS 2 30 Blown 48 ft2 0.1 Wood 19 Under Attic (Vented) BEDROOM 2 30 Blown 191 ft2 0.1 Wood 20 Under Attic (Vented) CLST 2 30 Blown 18 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 S Exterior Concrete Block - Ext Insul M TOILET 4.1 6 0 9 4 56.0 112 0 0 0.6 0 _ 2 W Exterior Concrete Block - Ext InsulM TOILET 4.1 4 0 9 4 37.3 f? 0 0 0.6 0 3 S Exterior Concrete Block - Ext Insul M BATH 4.1 12 0 9 4 112.0 ft2 0 0 0.6 0 - 4 W Exterior Concrete Block - Ext Insul M BATH 4.1 7 0 9 4 65.3 ft2 0 0 0.6 0 5 N Exterior - Concrete Block - Ext InstFAASTER BE 4.1 14 0 10 , 4 144.7 ft2 0 0 0.6 0 6 W Exterior Concrete Block - Ext InsMASTER BE 4.1 14 0 10 4 144.7 ft2 0 0 0.6 0 7 S Exterior Concrete Block- Ext Insul M W IC 4.1 12 0 9 4 112.0 112 0 0 0.6 0 8 E Garage Frame - Wood M W IC 13 14 0 9 4 130.7 ft2 0 0.1 0.6 0 _ 9 E Garage Frame - Wood UTILITY 13 7 0 9 4 65.3 112 0 0.1 0.6 0 10 E Garage Frame - Wood M HALL 13 4 0 9 4 37.3 ft2 0 0.1 0.6 0 11 N Exterior Concrete Block - Ext Insul DINING 4.1 8 0 9 4 74.7 ft2 0 0 0.6 0 12 W Exterior Concrete Block - Ext Insul DINING 4.1 14 0 9 4 130.7 ft2 0 0 0.6 0 13 S Garage Frame - Wood KITCHEN 13 11 0 9 4 102.7 ft2 0 0.1 0.6 0 14 E Exterior Concrete Block - Ext Insul PANTRY 4.1 14 0 9 4 130.7 ft2 0 0 0.6 0 15 S Garage Frame - Wood PANTRY 13 7 0 9 4 65.3 ft2 0 0.1 0.6 0 16 E Exterior Concrete Block - Ext Insul FOYER 4.1 9 0 9 4 84.0 ft2 0 0 0.6 0 17 N Exterior Concrete Block - Ext InsMEDROOM 4 4.1 9 0 9 4 84.0 ft2 0 0 0.6 0 18 E Exterior Concrete Block - Ext InstBEDROOM 4 4.1 14 0 9 4 130.7 ft2 0 0 0.6 0 19 S Exterior Concrete Block - Ext InstBEDROOM 4 4.1 5 0 9 4 46.7 1`12 0 0 0.6 0 20 W Exterior Concrete Block - Ext InsdilVING ROO 4.1 19 0 10 4 196.3 ft2 0 0 0.6 0 4/8/2020 11:56 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space Ft n Area AhSorn 21 S Exterior Concrete Block - Ext InsuIHALLW AY 4.1 1 0 9 4 9.3 ft2 0 0 0.6 0 _ 22 N Exterior Concrete Block - Ext InstBEDROOM 3 4.1 13 0 9 4 121.3 ft2 0 0 0.6 0 _ 23 E Exterior Concrete Block - Ext InstBEDROOM 3 4.1 13 0 9 4 121.3 ft2 0 0 0.6 0 24 N Exterior Concrete Block - Ext Insul CLST 3 4.1 2 0 9 4 18.7 ft2 0 0 0.6 0 25 N Exterior Concrete Block - Ext Insul BATH 2 4.1 8 0 9 4 74.7 ft2 0 0 0.6 0 26 N Exterior Concrete Block - Ext InsiBEDROOM 2 4.1 13 4 9 4 124.4 ft2 0 0 0.6 0 27 S Exterior Concrete Block - Ext InstSEDROOM 2 4.1 4 0 9 4 37.3 ft2 0 0 0.6 0 28 W Exterior Concrete Block - Ext InsddEDROOM 2 4.1 15 1 9 4 140.8 ft2 0 0 0.6 0 29 S Exterior Concrete Block - Ext Insul CLST 2 4.1 9 0 9 _4 84.0 ft2 0 0 0.6 0 30 W Exterior Concrete Block - Ext Insul CLST 2 4.1 2 0 9 4 18.7 ft2 0 0 0.6 0 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 3 Metal Low-E Single Yes 0.65 0.25 N 12.0 ft2 2 ft 0 in 1 ft 4 in None None 2 W 4 Metal Low-E Single Yes 0.65 0.25 N 12.0 ft2 2 ft 0 in 1 ft 4 in None None 3 W 6 Metal Low-E Single Yes 0.65 0.25 N k 30.0 ft2 2 ft 0 in 1 ft 4 in None None 4 W 12 Metal Low-E Single Yes 0.65 0.25 N 40.0 ft2 2 ft 0 in 1 ft 4 in None None 5 E 14 Metal Low-E Single Yes 0.65 0.25 N 4.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 6 E 16 Metal Low-E Single Yes 0.65 0.3 N 48.0 ft2 2 ft 0 in 1 ft 4 in None None 7 E 18 Metal Low-E Single Yes 0.65 0.25 N 18.0 ft2 2 ft 0 in 1 ft 4 in None None 8 W 20 Metal Low-E Single Yes 0.65 0.25 N 45.0 ft2 16 ft 0 in 1 ft 4 in None None 9 W 20 , Metal Low-E Single Yes 0.65 0.3 N 48.0 ft2 16 ft 0 in 1 ft 4 in None None 10 E 23 Metal Low-E Single Yes 0.65 0.25 N 18.0 ft2 2 ft 0 in 1 ft 4 in None None 11 N 25 Metal Low-E Single Yes 0.65 0.25 N 6.0 ft2 2 ft 0 in 1 ft 4 in None None 12 W 28 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 600 ft2 600 ft2 1+1 ft 9 ft 13 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000414 2610.5 143.31 269.52 .1522 7 418/202011:56 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit! Split Single SEER: 16 46.5 kBtu/hr 1395 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # v/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 200 ft2 Attic 20 ft2 Default Leakage Garage (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan Feb Mar HeatinJan Feb Mar _ Apr Ma X Jun X Jul j Jun r j Jul II Ma jjX� Au (] AuE [Xj Se ] SeP JA Oct Oct Nov Nov Dec Dec Ventin Jan Feb Mar A r May Jun Jul l [[ ] Aug j Se Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (W EH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (W D) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 M TOILET Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8lbs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC Default(8 Ibs/sq.ft. ft2 ft 0.3 UTILITY Default(8lbs/sq.ft. ft2 ft 0.3 M HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 DINING Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN 4/8/2020 11:56 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. ft2 ft 0.3 PANTRY Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft, ft2 ft 0.3 CLST 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 LIVING ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 HALLWAY Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft -� 0.3 CLST 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 SINKS 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/s .ft. ft2 ft 0.3 CLST 2 4/8/2020 11:56 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA "ec'el ft TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIAP SAY 1 �74z0 ermltr,.._ t. GUc/e ePdrtme Project Name: RESENDIZ RESIDENCE Builder Name: n County Street: 4413 PRESSLER LANE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Y U Owner: ARTEMIO RESENDIZ Jurisdiction: ST LUCIE COUNTY w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceilinglattic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring an J plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind Diping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of [CC-400. 4/8/2020 11:57 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Garage 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 46.5 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2406 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.266 14. Heating system: Capacity 34.0 c) Area 7c. 296.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor: (weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 13.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: (4Date: S 1 121�20 Address of New Home: 4413 PRESSLER LANE City/FL Zip: FORT PIERCE, FL 4/8/2020 11:57:31 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1