HomeMy WebLinkAboutProject InformationProject Summary Date: Apr08,2020 -- wrightsoft Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM Project Information For: ARTEMIO RESENDIZ MAY 1 9 7i17Q 4413 PRESSLER LANE, FORT PIERCE, FL Permitting pepal.rmew Notes: St. Lucie coti., Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 28196 Btuh Structure 23490 Btuh Ducts 8595 Btuh Ducts 12254 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 36790 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 33957 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3993 Btuh Ducts 3424 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area (ft2) 2406 2406 - Equipment latent load 7417 Btuh Volume (ft3) 22377 22377 Air changes/hour 0.32 0.16 Equipment Total Load (Sen+Lat) 41374 Btuh Equiv. AVF (cfm) 119 60 Req. total capacity at 0.70 SHR 4.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR6049J1 AHRI ref Coil TEM4AOC48S41++TDR AH R I ref 8676081 Efficiency 100 EFF Efficiency 13.5 EER, 16 SEER Heating input 10.2 kW Sensible cooling 32550 Btuh Heating output 34740 Btuh Latent cooling 13950 Btuh Temperature rise 20 OF Total cooling 46500 Btuh Actual air flow 1550 cfm Actual air flow 1550 cfm Air flow factor 0,042 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. V - wr1g1mt:soft- 2020-Apr-0811:34:51 Right -Suite® Universal 2019 19.0.08 RSU08101 Page 1 ...ocumnets\Wrightsoft HVAC\RESENDIZ RESIDENCE.rup Calc = MJ8 Front Door faces: E -�- wrightsoft Right-M Worksheet Job: Entire House Bate: Apr 08, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House M TOILET 2 Exposed wall 241.3 ft 10.0 ft 3 Room height 9.3 ft 9.3 ft heat/cool 4 Room dimensions 4.0 x 6.0 ft 5 Room area 2406.2 ft2 24.0 ft2 Ty Construction U-value Or - HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-'F) (Stuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 1$! 13A-4ocs 2 glazing, clr low-e . _ 13AAocs 0.143 _ _ 0.650 0.143 n _ n _ a 4.00 -. 18.20 4.00 2.19 _ 14.99 2.19 626 6 465 620 0 377 2483 109 1510 1357 90 825 0 0 0 0 0 0 0 0 0 0 0 0 --C 11 2 glazing, clr low-e 2 glazing, cir low-e 0.650 0.650 a a 18.20 18.20 32.65 3293 36 48 4 4 655 874 1175 1581 0 0 0 0 0 0 0 0 VjJ �G 2 glazinq, clr low-e 13A-4ocs 0.650 0.143 a s 18.20 4.00 19.12 2.19 4 456 1 444 73 1777 76 971 0 56 0 56 0 ' 223 0 122 2 glazing, clr low-e - 0.650, s 18.20 _ 14.99 12 24 218 180 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 698 508 2034 1111 37 37 149 81 2 glazing, cir low-e 0.650 w 18.20 32.08 12 2 218 385 0 0 0 0 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, cir low-e 0.650 0.650 0.650 w w w 18.20 18.20 18.20 3242 32.42 14.99 45 40 45 6 6 90 819 728 819 1459 1297 675 0 0 0 0 0 0 0 0 0 0 0 0 2 glazinq, cir low-e 16B-30md 0.650 0.032 w - 18.20 0.90 14.99 1.60 48 2406 96 2406 874 2156 720 3850 0 24 0 24 0 22 0 38 C F 22A-tph 1.358 38.02 0.00 2406 241 9176 0 24 10 380 0 6 c)AEDemursion 1955 -16 Envelope loss/gain 24523 17706 774 226 12 a) Infiltration 3673 984 152 41 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 4800 0 Subtotal (lines 6 to 13) 28196 23490 926 267 Less evemel load 0 0 0 0 Less transfer Redistribution 0 0 0 0 0 0 0 0 14 Subtotal 28196 23490 926 267 15 Duct loads 301/o 529/o 8595 12254 30% 52% 282 139 Total room load 36790 35744 1209 406 Air required (cfm) 1550 1550 51 18 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. =1g1Vtsof'ta 2020-Apr-0811:34:51 Right-SufteO Universal 2019 19.0.08 RSU08101 Page 1 ...ocumnets\Wrightsoft HUAC\RESENDIZ RESIDENCE.rup Calc = MJ8 Front Door faces: E -F+ wrightsoft° Right-JO Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM Job: Date: Apr 08, 2020 By: 1 Room name M BATH MASTER BEDROOM 2 Exposed wall 19.0 ft 28.0 ft 3 Room height 9.3 ft heat/cool 9.3 ft heaUcool 4 5 Room dimensions Room area 1.0 x 174.0 ft 174.0 ft2 1.0 x 260.0 ft 260.0 ft2 Ty Construction number U-value (Btuhlft-°F) Or HTM (BtUtV t2) Area (W) or perimeter (ft) Load (Btuh) Area (W) or perimeter (ft) toad (Btuh) Heat Cool Gross WKS Heat Cool Gross NIP/S Heat Cool 6 13A-4ocs 2 glazing, cir low-e_ 13A4ocs 0.143 0.650 0.143 n n a 4.00 18.20 4.00 2.19 14.99 2.19 0 0 0 0 0 0 0 0 0 0 0 0 130 0 0 130 0 0 521 0 0 285 0 0 11 2 glazing, cir low-e 2 glazing, cir low-e 0.650 0.650 a a 18.20 18.20 32.65 3293 0 0 0 0. 0 0 0 0 0 0 0 0 0 0 0 0 2 dazina, dr-low-e 13A-4ocs 2 glazing, cir low-e 0.650 0.143 0.650 a s s - 18.20 4.00 18.20 19.12 2.19 _ 14.99 0 112 12 0 100 12 0. 399 218 0 218 180 0 0 0 0 0 0 0 0 0 0 0 0 y✓ �--G 13A-4ocs 2 glazing, cir low-e 0.143 0.650 w w 4.00 18.20 2.10 32.08 65 12 53 1 213 218 116 385 130 0 100 0 401 0 219 0 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, cir low-e 0.650 0,650 0.650 w w w 18.20 18.20 18.20 3242 3242 14.99 0 0 0 0 0 0 0 0 0 0 0 0 30 0 0 2 0 0 646 0 0 973 0 0 2 glazina clr low-e 166-30md .. 0.650 0A32 ,w_- 18.20 _ _._0.90 14.99 1.60 0 174 0 174 0 156 0 278 0 - 260 0 260 0 . 233 0 416 F 22A_tph__ - 1.358 _.38.02 _ 0.00 174 19 _ _ 722 0 1260 28 1065 0 r l 6 c) AED excursion 76 262 Envelope loss/gain 1927 1253 2766 2154 12 a) Infiltration 289 .77 426 114 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 50 1000 Subtotal (lines 6 to 13) 2216 1381 3192 3268 Less evemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 6 10 14 Subtotal 2216 1381 3198 3279 15 Duct loads 30% 521/a 675 720 30°/u 52% 975 1710 Total room load 2891 2101 4173 4989 Air required (ofm) 122 91 176 216 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrlightsof t' 2020-Apr-08 11:34:51 Right-Sufte@ Universal 2019 19.0.08 RSU08101 Page 2 ...ocumnets\Wrightsoft WAC\RESENDIZ RESIDENCE.rup Calc = MJ8 Front Door faces: E -�-Job: wrightsoft Right-J® Worksheet Date: Apr 08, 2020 Entire House By. QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name M WIC UTILITY - 2 Exposed wall 12.0 ft 0 ft 3 Room height 9.3 ft heat/cool 9.3 ft heat/cool 4 5 Room dimensions Room area 14.0 x 12.0 ft 168.0 ft2 7.0 x 12.0 ft 84.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (W) Load number (Btut✓ft2-°F) (BtUlV t2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 V)i 13A-4ocs 0.143 n 4.60 2.19 0 0 0 0 0 0 0 0 2.g1a7ing clr low-e 13A4ocs 0.650 0.650 n a 18.20 4.00 14.99 2. 0 0 0 0 0 0 0 0 0 0 0- 0 0 0 0 0 -G 11 2 glazing, cir low-e 2 glazing, cir low-e 0.650 0.650 a a 18.20 18.20 32.6565 32.93 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 dazinq, cir low -el 13A-4ocs 0.650, 0.143 e s _ 118.20 4.00 19.12 2.19 0 112 0 112 0 447 0 244 0 0 0 0 0 0 0 0 VY �G 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 13A4ocs 2 glazing, clr low-e 0.143 0.650 w w 4.00 18.20 2.19 32.08 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 32.42 0 0 0 0 0 0 0 0 2 glazing, clr low-e 2 glazing, clr low-e 0.650 0.650 w w 18.20 18.20 32.42 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazinq, clr low-e 16B-30md 0.650 0.032 w - 18.20 0.90 14.99 1.60 0 168 0 168 0 151 0 269 0 84 0 84 0 75 0 134 C F 22A-tph 1.358 - 38.02 0.00 168 12 456 0 84 0 0 0 6 c) AED excursion -53 -46 Envelope loss/gain 1054 459 75 88 12 a) Infiltration 183 49 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 400 700 Subtotal (lines 6 to 13) 1236 908 75 788 Less extemal load Less transfer 0 0 0 0 0 0 0 0 Redistribution 0 0 15 25 14 Subtotal 1236 908 90 813 15 Ductloads 30% 521/0 377 474 W/u 52% 27 424 Total roan load 1613 1382 118 1237 Air required (cfm) 68 60 5 54 . Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wriigFr ts- frt- 2020-Apr-08 11:34:51 !" --"" Right -Suite@ Universal 2019 19.0.08 RSU08101 Page 3 ...ocumnets\Wrightsoft HVAC\RESENDIZ RESIDENCE.rup Calc = MJ8 Front Door faces: E - wrightsoft° Right-M Worksheet Job: Entire House Date: Apr 08, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name I M HALL DINING 2 3 E1tposed wall Room height 0 ft 9.3 ft heat/cool 22.0 it '9.3 ft heat/cool 4 5 Room dimensions Room area 4.0 x 10.0 ft 40.0 IF 14.0 x 9.0 ft 126.0 ft2 Ty Construction number U-value (Btuttrftz°F) Or HTM (Btuh/ft2) Area (W) or perimeter (ft) Load (Btuh) Area (W) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 13A4ocs 2.glazing, cir low-e _ 13A-4ocs 2 glazing, cir low-e 2 glazing, dr low-e 2 dazing, cIr low-e__ 2 glazing,-dr low,e _ 13A-4ocs 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir iow-e 2 glazing, clr low-e 2 glazing, cir low-e -" _16B73Umd.- - . -- - 0.143 _0.650 0.143 0.650 0.650 0.650 0.143 . 0.650 0.143 0.650 0.650 0.650 0.650 _0.650 -- -- 0.032 n n- a a a _ e. s . s - w w w w w w_ _ _ . 4.00 --18.20, 4.00 18.20 18.20 18.20 4.00 18.20 4.00 18.20 18.20 18.20 18.20 __ 18.20 0.90 2.19 _ 14.99 2.19 32.65 32.93 19.12 2.19 14.99 2.19 32.08 3242 32.42 14.99 14.99 _ 1.60 0 _ 0 0 0 0 0 0. _0 0 0 0 0 0 0 40 0 0 0 0 0 0 0 0 0 0 0 0 0 0 .40- 0 A- 0 0 0 0 0 0 0 0 0 0 0 0 36 0 .. 0 0 0 0 0 0 0 0 0 0 0 0 0 64 74 0 0 0 0 0_ 0 0 130 0 0 40 0 0 _ 126 74 0 0 0 0 0 0 0 90 0 0 3 0 0 126 298 0 0 0 0 0_ 0 0 361 0 0 728 0 0 113 163 0 0 0 0 0 0 0 197 0 0 1297 0 0 202 t13A-4ocs -G C _ F - 22A-tph 1.358 38.02 0.00 40 0 0 0 126 22 837 0 6 c) AED excursion -4 463 Envelope loss/gain 36 60 2336 2322 12 a) Infiltration 0 0 335 90 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 36 60 2671 2412 Less witemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -36 -60 4 8 14 Subtotal 0 0 2676 2419 15 Duct loads 300/0 52% 0 0 30% 52% 816 1262 Total roan load 0 1 0 3411 3681 Air required (cfm) 0 0 147 160 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Fk- wrlgfstsoft^ 2020-Apr-08 11:34:51 Right-Suite@ Universal 2019 19.0.08 RSU08101 Page 4 ...ocumnets\Wrightsoft WAC\RESENDIZ RESIDENCE.rup Calc = MJ8 Front Door faces: E -� wrightsoft' Right-M Worksheet Job: Entire House Date: Apr 08, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name KITCHEN PANTRY 2 F)posed wall 0 ft 14.0 ft 3 Room height 9.3 ft heat/cool 9.3 ft heat/cool 4 5 Room dimensions Room area 14.0 x 18.0 ft 252.0 ft2 14.0 x 7.0 ft 98.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (W) load number (BtuWft2-°F) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W �G 13A-4ocs 2 glazing,-clr law-e 13AAocs 0,143 0.650 0.143 n n a 4.00 18.20 4.00 2.19 14.99 2.19 0 0 0 0 0 0 0 0 0 0 0 0 0 0 130 0 0 126 0 0 505 0 0 276 11 2 glazing, cir low-e 2 glazing, cir low-e 0.650 0.650 a a 18.20 18.20 32.65 32.93 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 dazinq, cir low-e 13A-4ocs 2 glazing, clr low-e -- 0.650 0.143 0.650 a s s 18.20 4.00 1&20 19.12 2.19 14.99 0 0 . 0 0 0 0 0 0 0 0 0 0 4 0 0 1 0 0 73 0 0 76 0 0 Y- G- 13A-4ocs 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, cir low-e 0.143 0.650 0.650 0.650 0.650 w w w w w 4.00 18.20 18.20 16.20 18.20 2.19 32.08 32.42 32.42 14.99 0 0 0 0 0 0 0 0 0 0 0 0 10 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C _ 2 glazinq, cir low-e 16B-30md 0.650 0.032 w - 18.20 0.90 14.99 1.60 0 252 0 252 0 226 0 403 0 98 0 98 0 88 0 157 F 22A-tph _ 1.358 - 38.02 0.00 252 0 0 0 98 14 - 532 0 6 c)AED excursion -89 -24 Envelope loss/gain 226 314 1198 486 12 a) Infiltration 0 0 213 57 b) Room ventilation 0 0 0 0 13 interimal gains: Occupants @ 230 0 0 0 0 Appliances/other 1200 0 Subtotal (lines 6 to 13) 1226 1514 1 1411 543 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 136 159 439 496 14 Subtotal 362 1673 1850 1039 15 Duct loads 301/o 52% 110 873 301/u 52% 564 542 Total room load 472 2546 2414 1581 Air required (ofm) 20 110 1 1 102 69 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. c -F�§- 2020-Apr-0811:34:51 Right -Suite® Universal 2019 19.0.08 RSU08101 Page 5 ...ocumnets\Wrightsoft HVAC\RESENDIZ RESIDENCE.rup Calc = MJ8 Front Door faces: E - wrightsoft Right-M Worksheet Job: Entire House Date: Apr 08, 2020 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name FOYER CLST 4 2 Exposed wall 9.0 It 0 It 3 Room height 9.3 It heat/cool 9.3 It heat/cool 4 Room dimensions 9.0 x 9.0 ft 10.0 x 2.0 ft 5 Room area 81.0 IF 20.0 ft2 Ty Construction U-value Or HTM Area (W) Load Area (ft2) Load number (Btuh/ft2-"F.) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 1A/ �-G_ 13A-4ocs 2 glazing,.cir lowe- • _ . 13A-4ocs 0.143 _ 0.650, 0.143 n _n a 4.00 18.20 4.00 2.19 _ 14.99 2.19 0 0 84 0 0 36 0 0 143 0 0 78 0 .0 0 0 . 0 0 0 0 0 0 0 0 V�j 11 2 glazing, cir low-e 2 glazing, clr low-e 0.650 0.650 a a 18.20 18.20 32.65 32.93 0 48 0 2 0 874 0 1581 0 0 0 0 0 0 •0 0 Vjl 2 dazina, cir low-e 13A-4ocs 0.650 0.143 a s 18.20 4.00 19.12 2.19 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 �C 2gaz1ng,drlow-e._ _ --- 0.650 s _._ 18.20. 14.99 0 0 0 0 0 0 0 0 13A-4ocs 2 glazing, cir low-e 0.143 0.650 w w 4.00 18.20 2.19 32.08 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 w 18.20 32.42 0 0 0 0 0 0 0 0 2 glazing, cir low-e 2 glazing, cir low-e 0.650 0.650 w w 16.20 18.20 32.42 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2.dazinq, cir low-e 16B-30md . _ 0.650 0.032 w.- 18.20 0.90 14.99 1.60 0 81 0 81 0 73 0 130 0 20 0 20 0 18 0 32 C - _ F 22A-tph 1.358 - 38.02 0.00 81 9 342 0 20 0 0 0 6 c)AED excursion -53 -2 Envelope losstgain 1431 1735 18 30 12 a) Infiltration 137 37 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1568 1772 18130 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -1568 -1772 -18 -30 14 Subtotal 0 0 0 0 15 Duct loads 300% 52% 0 0 301/o 521/o 0 0 Total room load 0 0 7 0 0 Air required (cfm) 0 0 01 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - wro 1�t�otrt• 2020-Apr-08 11:34:51 Right -Suite@) Universal 2019 19.0.08 RSU08101 Page 6 ...ocumnets\Wrightsoft WAC\RESENDIZ RESIDENCE.rup Calc = MJ8 Front Door faces: E wrightsoft Right-M Worksheet Job: Entire House Date: Apr 08, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM 4 LMNG ROOM 2 Exposed waii 28.0 ft 19.0 ft 3 Room height 9.3 ft heat/cool 9.3 ft heat/cool 4 Room dimensions 1.0 x 176.0 ft 19.0 x 17.0 ft 5 Room area 176.0 ft2 323.0 ft2 Ty Construction number U-value (Btuh/ftz°F) Or HTM (Btuh/ft2), Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 1R! �C 13A-4ocs 2 glazing, cir low-e 13A-4ocs 0.143 0.650 0.143 n n a 4.06 18.20 4.00 2.19 14.99 2.19 84, 0 130 84 0 112 335 0 449 183 0 245 0 0 0 0 0 0 0 0 0 0 0 0 VV 11 2 glazing, cir low-e 2 glazing, cir low-e 0.650 0.650 a a 18.20 18.20 32.65 32.93 18 0 1 0 328 0 588 0 0 0 0 0 0 0 0 0 2 dazina. cir low-e 13A-4ocs 2 glazing, Gr_bwce _ 0.650 0.143 .. _ 0.650 a s s 18.20 4.00 18.20 19.12 2.19 14.99 0 47 0 0 47 0 0 186 0 0 102 0 0 0 0 0 0 0. 0 0 0 0 0 0 1t)/ IV 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 M 84 335 183 2 glazing, cir low-e 0.650 w 18.20 32.08 0 0 0 0 0 0 0 0 2 glazing, cir low-e 2 glazing, dr low-e 2 glazing, cir low-e 0.650 0.650 0.650 w w w 18.20 18.20 18.20 32.42 32.42 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 45 0 0 45 0 0 , 819 0 0 675 2 glazinq, cir low-e_ 16B-30md 0.650 0.032. w - 18.20 0.9Q 14.99 _ 1.60 0 176 0 176 0 158 0 282 48 323 48 323 874 289 720 517 C _ F 22A-tph 1.358 38.02 0.00 176 28 1065 0 323 19 722 0 6 c) AED excursion -87 1586 Envelope loss/gain 2521 1312 3040 3680 12 a) Infiltration 426 114 289 77 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 300 0 Subtotal (lines 6 to 13) 2947 1726 3329 3757 Less e)demal load 0 0 0 0 Less transfer Redistribution 0 464 0 525 0 637 0 706 14 Subtotal 3411 2252 3966 4463 15 Duct loads 300/. 52% 1040 1175 30°/a 521/o 1209 2328 Total room load 4450 3426 5174 6792 Air required (ofm) 187 149 218 295 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. F].h wrigft2:43oft- 2020-Apr-0811:34:51 CM Right -Suite® Universal 2019 19.0.08 RSU08101 Page 7 ...ocumnets\Wrightsoft WAC\RESENDIZ RESIDENCE.rup Calc = MJ8 Front Door faces: E - wrightsoft Right-M Worksheet Job: Entire House Date: Apr 08, 2020 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name HALLWAY BEDROOM 3 2 Eip sed wall 1.0 ft 26.0 ft 3 Room height 9.3 ft heat/cool 9.3 ft heat/cool 4 5 Room dimensions Room area 4.0 x 18.0 ft 72.0 ft2 13.0 x 13.0 ft 169.0 ft2 Ty Construction number U-value (Btuit/ftZ"F) Or HTM (Btuh/ft2) Area (W) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 V1J_ L.-G 13A-4ocs 2 glazing, cir low-e 13A-4ocs 0.143 0.650 0.143 n n a 4.00 18.20 4.00 2.19 14.99 2.19 0 0 0 0 0 0 0 0 0 0 0 0 121 0 121 121 0- 103 484 0 412 265 0 225 11 2 glazing, cir low-e 2 glazing, cir low-e 0.650 0.650 a a 18.20 18.20 32.65 32.93 0 0 0 0 0 0 0 0 18 0 1 0 328 0 588 0 L� t-G 2 dazinq, clr low-e 13A-4ocs 2 glazing, cir low-e _ 0.650 0.143 0.650 . e s s 18.20 4.00 _ 18.20 . 19.12 2.19 14.99 0 9 0 0 9 0 0 37 0 0 20 0 0 0 0 0 0 0 0 0 0 0 0 0 13A-4ocs 2 glazing, clr low-e 0.143 0.650 w w 4.00 18.20 2.19 32-08 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 0.650 0.650 0.650 w w w 18.20 18.20 18.20 3242 32.42 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e 16B-30rnd _ 0.650 0.032 w - 18.20 0.90 14.99 _ 1.60 0 72 0 72 0 65 0 115 0 169 0 169 0 151 0 270 C _ _ F 22A1ph- 1.358 - 38.02 0.00 .c 72 1 38 0 r- - 169 26 _ 989 0 6 c) AED excursion -8 -115 Envelope losstgain 140 128 2364 1233 12 a) Infiltration 15 4 396 106 b) Room ventilation 0 0 0 0 13 I ntemal,gairs: Occupants @ 230 0 0 0 0 Appliances/other 0 850 Subtotal (lines 6 to 13) 155 132 2759 2189 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -155 -132 132 68 14 Subtotal 0 0 2892 2257 15 Duct loads 301/6 521/6 0 0 301/o 52% 881 1178 Total room load 0 0 3773 3435 Air required (ofm) 10 0 159 149 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wriightsof t� 2020-Apr-08 11:34:51 RightSuite® Universal 2019 19.0.08 RSU08101 Page 8 ...ocumnets\Wrightsoft HVAC\RESENDIZ RESIDENCE.rup Calc = MJ8 Front Door faces: E �- wrightsoft Right-M Worksheet Job: Entire House Date: Apr 08, 2020 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name CLST 3 BATH 2 2 E)q=ed wall 2.0 ft 8.0 ft 3 Room height 9.3 ft heaUcod 9.3 ft heat/cool 4 5 Room dimensions Room area 13.0 x 2.0 ft 26.0 ft2 7.0 x 8.0 ft 56.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-"F) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 If13A-4ocs �G. 2 glazing, cir Iow-a 13A4ocs 0.143 0.650 0. n _ n a 4.00 18.20 4. 2.19 14.99 2. 19 0 0 19 0 0 74 0 0 41 0 0 74 6 0 68 _ 0 0 274 109 0 150 _ 90 0 2 glazing, clr low-e 0.650650 a 18.2020 32.6565 0 0 0 0 0 0 0 0 11 2 glazing, clr low-e 0.650 a 18.20 32.93 0 0 0 0 0 0 0 0 Vj! 2 glazing, dr low-e 13A-4ocs 0.650 0.143 a s 18.20 4.00 19.12 2.19 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 �-C 2.4azing, dr low-e - 0.650 . s- 18.20 14.99 0 0 0 0 _ 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 w 18.20 32.08 0 0 0 0 0 0 0 0 2 glazing, cir low-e 2 glazing, dr low-e 2 glazing, dr low-e 0.650 0.650 0.650 w w w 18.20 18.20 18.20 32.42 32.42 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C.. _. _ 2_glazinq, clrlow-e - 16B-30md , _ _ _ 0.650 _ - 0.032 w ._. - _ 18.20 -_ 0.90 _ 14.99 1.60 0 _ 26 0 26 0_ _ 23 0 _ 42. 0 _ 56 0 .. 56 0 . 50 0 - 90 F 22A-tph 1.358 38.02 0.00 26 2 76 0 56 8 304 0 6 c)AED erxursion -5 -20 Envelope loss/gain 174 77 737 309 12 a) Infiltration 30 8 122 33 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 204 85 859 342 Less e)demal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -204 -85 55 23 14 Subtotal 0 0 914 365 15 Duct loads 30°% 52% 0 0 300/. 5210% 279 190 F1Total room load T-T 0 0 1 1193 555 Air required (cfm) 0 OF 50 24 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. -+*- wrilgFrrtsol t• 2020-Apr-08 11:34:51 A!aP. """ '" Right -Suite® Universal 2019 19.0.08 RSU08101 Page 9 ...ocumnets\Wrightsoft HVAC\RESENDIZ RESIDENCE.rup Calc = MJ8 Front Door faces: E wrightsoft Right-M Worksheet Job: Entire House Date: Apr 08, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone': 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name SINKS 2 BEDROOM 2 2 Exposed wall 0 ft 32.3 ft 3 Room height 9.3 ft heat1cool 9.3 ft heat/cool 4 5 Room dimensions Room area 6.0 x 8.0 ft 48.0 ft2 1.0 x 191.2 ft 191.2 ft2 Ty Construction number U-value (BtuWftz-°F) Or HTM (Btuhlft2) Area (W) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 W G 13A-4ocs 2.glazing, cir low-e 13AAocs 0.143 0.650 0'143 n . n a 4A0 18.20 4.00 2.19 14.99 2'19 0 _ 0 0 0 0 0 0 0 0 0 0 0 124 0 0 124 0_ 0 496 0 0 271 0 0 �/ 11 �C IL�G 2 glazing, cir low-e 2 glazing, cir low-e 0.660 0.650 a a 18.20 18.20 32.65 32.93 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 V)/ l-f 2 glazinu, cir low-e _ 13A-4ocs 2_glazing, Gr lowre .. 0.650 0.143 0.650 _ _e s s 16.20 4.00 1&20 - 19.12 2.19 14.99 0 0 0 0 0 . 0 0 0 0 0 0 0 0 37 0 0 37 0 _ 0 149 0 0 81 0 13A-4ocs 2 glazing, clr low-e 0.143 0.650 w w 4.00 18.20 2.19 32.0E 0 0 0 0 0 0 0 0 140 0 125 0 501 0 273 0 2 glazing, clr low-e 2 glazing, clr law-e 2 glazing, cir low-e 0.650 0.650 0.650 w w w 18.20 18.20 18.20 3242 32.42 14.99 0 0 0 0 0 0 0 0 0 0 0 0 15 0 0 1 0 0 273 0 0 486 0 0 2 glazing, cir low-e 1613-30md 0.650 0.032 w 18.20 0.90 14.99 1.60 0 48 0 48 0 43 0 77 0 191 0 191 0 171 0 306 C F 22A-tph 1.358 - 38.02 0.00 48 0 0 0 191 32 1229 0 6 c) AED excursion -4 112 Envelope loss/gain 43 73 2820 1530 12 a) Infiltration 0 0 493 132 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 300 Subtotal (lines 6 to 13) 43 73 3312 1962 Less external load 0 0 0 0 Less transfer 0 0 0 0 Red'istritwtiat 77 45 1026 294 14 Subtotal 120 118 4339 2256 15 Duct loads 301/o 52% 37 62 3v/. 52% 1323 1177 Total roan load 157 180 1 5662 3432 Air required (cfm) 7 8 239 149 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Fid- wr9ghytsofte 2020-Apr-08 11:34:51 A�A Right -Suite@ Universal 2019 19.0.08 RSU08101 Page 10 ...ocumnets\Wrightsoft HVAC\RESENDIZ RESIDENCE.rup Calc = MJ8 Front Door faces: E -�- wrightsof , Right-M Worksheet Job: Entire House Date: Apr 08, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name CLST 2 2 E)posed wall 11.0 ft 3 Room height 9.3 ft heat/cool 4 5 Room dimensions Room area 2.0 x 9.0 ft 18.0 ft2 Ty Construction number U-value (Btuh/ft' =F) Or HTM (Btuh/ftz) Area (W) or perimeter (ft) Load (Btuh) Area or perimeter Load Heat Cool Gross N/PIS Heat Cool Gross N/P/S Heat Cool 6 �C 13A4ocs 2 glazing, clr low-e 13A-4ocs 0.143 0.650 0.143 n n . a 4.00 18.20 4.00 2.19 14.99 2.19 0 0 0 0 0 0 0 0 0 0 0 0 11 2 glazing, clr low-e 2 glazing, cir tow-e 0.650 0.650 a a 18.20 18.20 32.65 32.93 0 0 0 0 0 0 0 0 2 olazinq, cir low-e 13A-4ocs 2 glazing, cir low-e _ _ 0.650 0.143 0.650 - e - s .s. - 18.20 4.00 _ 18.20 19.12 2.19 _ .14.99 0 84 0 0 84 0 0 335 0 0 183 0 1� 1---G_ 13A-4ocs 2 glazing, cir low-e 0.143 0.650 w W 4.00 18.20 2.19 32.08 19 0 19 0 74 0 41 0 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 0.650 0.650 0.650 w w w 18.20 18.20 18.20 32.42 32.42 14.99 0 0 0 0 0 0 0 0 0 0 0 0 C_-. . _ 2 glazinq,, clr low-e_ _ - 168-30md _ .-- - 0.650 0,032 _. w _- 18.20 0.90 14.99 1.60 0 18 0 _ 18 0 16 0 - 29 F 22A-tph _ _- - _- _ . -_ 1.358 -_-, 38.02 0.00 ._ 18 11 418 0 - r 6 c) AED excursion -17 Envelope loss/gain 844 236 12 a) Infiltration 167 45 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13) 1011 281 Less external load 0 0 Less transfer 0 0 Redistribution -1011 -281 14 Subtotal 0 0 15 Duct loads 300% 52% 0 0 FT Total roan load -T 0 0 Air required (cfm) 01 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 1 -rk- wrlghtsoti°ta 2020-Apr-08 11:34:51 ��'""" "- Right -Suite® Universal 2019 19.0.08 RSU08101 Page 11 ...ocumnets\Wrightsoft HVAC\RESENDIZ RESIDENCE.rup Calc = MJ8 Front Door faces: E System stem Summary Job: -�- wrightsoft� Dy Date: Apr 08, 2020 Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM I For. ARTEMIO RESENDIZ 4413 PRESSLER LANE, FORT PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1550 cfm . Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft L 1550 cfm 212 ft Name Design (Btuh) Htg (Cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 2 h 1193 50 24 1.000 5.0 OxO VIFx 55.7 155.0 sty BEDROOM 2 h 5662 239 149 1.000 8.0 OxO VIFx 57.1 155.0 st5 BEDROOM 3 h 3773 159 149 1.000 8.0 Ox0 VIFx 45.8 135.0 st4 BEDROOM 4 h 4450 187 149 1.000 8.0 Ox0 VIFx 42.6 135.0 st4 DINING c 3681 147 160 1.000 8.0 Ox0 _ VIFx 21.2 115.0 st2 KITCHEN c 2546 20 110 1.000 7.0 Ox0 VIFx 18.3 115.0 st2 LIVING ROOM C 3396 109 147 1.000 8.0 OxO VIFx 39.1 135.0 st4 LIVING ROOM -A c 3396 109 147 1.000 8.0 Ox 0 VIFx 43.0 135.0 st4 M BATH h 2891 122 91 1.000 7.0 Ox0 VIFx _ 18.1 115.0 st1 •TOILET h 1209 51 18 1.000 4.0 Ox0 VIFx 33.3 135.0 st3 • WIC h 1613 68 60 1.000 6.0 Ox0 VIFx 17.7 115.0 st1 MASTER BEDROOM C 2494 88 108 1.000 7.0 Ox 0 VIFx 31.3 135.0 st3 MASTER BEDROOM -A C 2494 88 108 1.000 7.0 Ox0 VIFx 16.7 115.0 st1 PANTRY h 2414 102 69 1.000 6.0 Ox0 VIFx 22.2 115.0 st2 SINKS 2 C 180 7 8 1.000 4.0 Ox 0 VIFx 56.7 155.0 st5 U-nLITY c 1237 5 54 1.000 6.0 Ox 0 VIFx 16.7 115.0 st1\ wrightsoft- 2020-Apr-08 11:34:58 �, +� •� •�--.mow RightSuhe@ Universal 2019 19.0.08 RSU08101 Page 1 ...ocumnets\Wrightsoft HVAC\RESENDIZ RESIDENCE.rup Calc = MJ8 Front Door faces: E Name Trunk Type Htg (cfm) Clg (cfm) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st5 Peak AVF 295 181 1.000 846 8.0 0 x 0 VinlFlx st4 st4 Peak AVF 860 773 1.000 933 13.0 0 x 0 VinlFlx st2 st2 Peak AVF 1129 1111 1.000 808 16.0 0 x 0 VinlFlx st3 Peak AVF 139 126 1.000 398 8.0 0 x 0 VinlFlx st1 st1 Peak AVF 421 439 1.000 665 11.0 0 x 0 VinlFlx Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox 0 1550 1550 0 0 0 0 Ox 0 VIFx wrightsoft® 2020-Apr-08 11:34:58 ram, v • ^"^M°^" ^ sw Right -Suite® Universal 2019 19.0.08 RSU08101 Page 2 �� ...ocumnets\Wrightsoft HVAC\RESENDIZ RESIDENCE.rup Calc = MJ8 Front Door faces: E