HomeMy WebLinkAboutAPPROVED Design Pressure Report (Albano) - Master Craft Aluminum Products Property Information Building Information Owner: Albano Wind Zone: 160 MPH. Address: 64 Mediterranean Blvd E Exposure Category: B Port St Lucie,Fl 34952 Minimum Building Dimension: 24 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 106 83 7 28.7 -31.4 2 End 106 83 7 28.7 -35.8 3 End 106 83 7 28.7 -35.8 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1