HomeMy WebLinkAboutAPPROVED Design Pressure Report (Hippolyte) - Master Craft Aluminum Products Property Information Building Information
Owner: Hippolyte Wind Zone: 160 MPH.
Address: 3732 St Marks Dr Exposure Category: B
Ft Pierce,Fl 34982 Minimum Building Dimension: 24 ft.
Mean Roof Height: 15 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 101 48 7 29.9 -32.7
2 End 74 48 7 30.6 -39.7
3 Int 52 38 7 31.8 -34.6
4 End 52 38 7 31.8 -42.2
5 End 52 38 7 31.8 -42.2
6 Int 19 27 7 32.5 -35.2
7 Int 52 49 7 31.3 -34.0
8 Int 72 50 7 30.5 -33.3
9 End 52 38 7 31.8 -42.2
10 End 52 38 7 31.8 -42.2
11 Int 37 38 7 32.5 -35.2
12 Int 36 36 7 32.5 -35.2
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.
Page 1 of 1