Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Vistana Temp Generator
Rental Power 200 kW } YOWC� � � GiY1E`�dtIO11 1.677•71IM7669 P to low Specification ■ , wer GO'� Generation • . . . p Description Engine controls • Oil Pressure and Water Temp Gauge This Cummins Power Generation rental package is a fully . Fuel Level Gauge&Battery Voltage Gauge integrated mobile power generation system, providing • Hour meter optimum performance, reliability and versatility for standby and prime power applications. Stamford alternators • 12-lead reconnectable alternators fitted with voltage Features selection switch Cummins diesel engines • Permanent magnet excitation for improved performance • U.S. EPA Tier III compliant in non-linear load applications • Rugged 4-cycle industrial diesel engine with excellent Rental package enclosure transient performance • Heavy duty trailer package with pintle hitch and electric or • Lightweight, compact and excellent fuel economy hydraulic brakes • 2-stage spin on fuel filter w/pre-filter water separator with . Sound attenuated, white powder coated lockable drain enclosure • Equipped with heavy duty,2-stage air cleaners with dust • 20 hour fuel tank(100% prime)with gauge ejector • Roof mounted, single point lift Control Features • Cooling system rated for 131° F(55° C)at 100% prime • The most advanced, reliable and capable generator set ambient control system on the market today • Complete engine fluid containment reservoir • Controls provide precise frequency and voltage regulation, • DOT approved trailer with light package, replaceable alarm and status message display in one easy to operate fenders and jack stand customer interface • Voltage selector switch • Remote monitoring and operation ready • Shore power(120 VAC)- No breakers in shore power • Auto shutdown at fault detection connection. Shore power loads are coolant heater (option)and battery charger(option). Connection: 15A/120V flanged male receptacle(5-20 flanged inlet). Standby rating Prime rating Model Voltages M 60 Hz 50 Hz 60 Hz 50 Hz Engine Alternator kW kVA) kW WA kW WA kW WA model model C200D6RT 208/480 200(250) 180(225) QSB7-G5 UCD1274J 480/600 switchable 200(250) 180(225) QSB7-G5 HC1434C ©2010 Cummins Power Generation.Cummins and PowerCommand are registered trademarks of Cummins Inc. Specifications are subject to change without notice. S-1616(1/10) Engine specifications Engine model QSB7-G5 Alternator data sheet UCD1274J(208/480),HC1434C(480/600) Engine data sheet DS-92278 Tier rating Tier III Design 4 cycle, In-Line,turbocharged and after-cooled Bore 107 mm(4.21 in.) Stroke 124.0 mm(4.88 in.) Displacement 6.69 liters(408 in) Cylinder block Cast iron, In-Line 6 cylinder Battery capacity 2 x 750 cca Battery charging alternator 100 amps Starting voltage 12 volt,negative ground Fuel system Direct injection HPCR system Fuel filter Spin on fuel filter with water separator Air cleaner type 2-stage,dry replaceable element with dust ejector Lube oil filter type(s) Single spin-on,full flow Standard cooling system 118°F(48°C)ambient radiator Alternator specifications Design Brushless,4 pole,drip proof revolving field Stator Double layer concentric,2/3 winding pitch Rotor Singe bearing,flexible disc Class H per NEMA MG1-1.65(208/480 VAC) Insulation system Class H per NEMA MG1-1.65 480/600 VAC switchable 115/500 C prime(208/480 VAC) Standard temperature rise 95/50°C prime 480/600 VAC switchable Exciter type PMG(permanent magnet generator) Phase rotation A(U),B(V),C(W) Alternator cooling Direct drive centrifugal blower fan AC waveform total harmonic distortion <1.5%no load,<5%non-distorting balance linear load Telephone influence factor(TIF) <50 per NEMA MG1-22.43 Telephone harmonic factor(THF) <2% Power capability specifications (Assume power factor = 0.80 for 3 phase amps) Standby rating 240 V, 1 phase Amps 2 88 V,3 phase Amps 480 V,3 phase Amps 600 V,3 phase Amps C200D6RT 542 1 694" 226 241 240V,3 phase=601 A Electrical power panel specifications 120 V duplex Load lug connection Load lug circuit Model voltage receptacles 240 V twist (stud diameter) breakers 120/480 Volt 2-20 Amp GFCI 3-50 Amp 1/2 inch 800 Amp 480/600 Volt switchable 0 0 1/2 inch 400 Amp Site derating factors Standby application: The engine may be operated at 1800 rpm up to 3,000 ft(915 m)and 122' F(50' C)without power deration. For sustained operation above these conditions, derate by 4% per 1,000 ft(300 m), and 8% per 18o F(10° C). Our energy working for you.TM www.cumminspower.com Power ©2010 Cummins Power Generation.Cummins and PowerCommand are registered trademarks of Cummins Inc. Generation Specifications are subject to change without notice. 5-1616(1/10) Control system PowerCommand control • Intake manifold temperature high • Integrated automatic voltage regulator and engine • Fail to start/stop speed governor • Over frequency • Control components designed to withstand the • Alternator reconnecting switch operated (breaker vibration levels typical in generator sets closed) Standard control description Agency approvals • Cycle cranking control • NFPA110 for Levels 1 or 2 systems • Digital display panel • ISO 8528-4: 1993 Compliance, Controls and • Idle mode control Switchgear • Menu switch • CE Marking • Panel backlighting • EN 50081-1, 2 Residential/Light Industrial Emissions or • Reset switch Industrial Emissions • Run-off-auto switch • EN 50082-1.2 • Self diagnostics • ISO 7637-2, Level 2: DC supply surge test Standard performance data warnings • Mil Std 202C, Method 101 and ASTM B117: Salt Fog Test • High coolant temperature • Designed and manufactured in ISO 9001 certified • High DC voltage facilities. UL 508 suitable for use on generator sets • Low coolant temperature that are UL 2200 Listed • Low DC voltage • Low oil pressure • Over current ,,• • Weak battery • Over speed 7,- ��.., • Under frequency •-' ' • Intake manifold temperature OOR high/low + • Intake manifold temperature high - • Water in fuel OORH/OORL • General engine fault • Coolant level OOR high/low Standard generator electrical features Standard protection functions • Multiple voltage selector switch (480/277 VAC/3 phase • Warnings or 240/139 VAC/3 phase or 240/120 VACA phase) • High coolant temperature • Adjustable to 208/120 VAC/3 phase • High DC voltage • Single phase convenience receptacles • Low coolant temperature • Distribution panel with L1, L2, L3 neutral and ground • Low DC voltage • Main line shunt trip type circuit breaker • Low oil pressure • Auto start-stop with remote contacts • Over current • Over current sensing • Weak battery • 3 available auxiliary connections Shutdowns Rental package options • Emergency stop local/remote • Immersion style coolant heater • Fail to crank o Tank style coolant heater • High AC voltage • Battery disconnect switch • High coolant temperature o Cam lock distribution panel • Low coolant level • 110 Volt, 5 Amp battery charger • Low AC voltage o Base mount generator-no trailer • Low oil pressure • 600 Volt/480 Volt switchable • Over current • Over speed • Under frequency Our energy working for you.Tm www.cumminspower.com Power ©2010 Cummins Power Generation.Cummins and PowerCommand are registered trademarks of Cummins Inc. Generation Specifications are subject to change without notice. S-1616(1 A 0) Ratings definitions f Standby: ®� Applicable for supplying emergency power for the g Generation duration of normal power interruption. No sustained 1•B77.769.7659 overload capability is available for this rating.(Equivalent C Po—I -- -�. to Fuel Stop Power in accordance with ISO3046, AS2789, DIN6271 and BS5514). Nominally rated. Prime (unlimited running time): Applicable for supplying power in lieu of commercially purchased power. Prime power is the maximum power available at a variable load for an unlimited number of A hours.A 10% overload capability is available for limited time. (Equivalent to Prime Power in accordance with IS08528 and Overload Power in accordance with ISO3046,AS2789, DIN6271, and BS5514). Dimensions Dim "A" Dim KB" Dim "C" Weight w/o fuel Weight with fuel Fuel capacity Model mm(in.) mm(in.) mm(in.) kg(Ibs) kg(Ibs) liters(gal) C200136RT 3700(146) 1450(57) 1 1700(67) 1 2878(6345) 3641 (8028) 1 965(255) With trailer 5410(213) 2140(84) 1 2309(91) 1 3654(8056) 4418(9739) 1 965(255) Specifications Model KW rating Sound level Tier rating Hours of operation (75% load) :::± Standby Prime dB(A)@ 7 m Standby Standby Prime C20OD6RT 1 200 190 70.5 Tier III 20 23 Fuel consumption Standby Prime 60 Hz Ratings,kW(kVA) 200(250) 190(237) Load 1/4 M! s/4 FUII 1/4 1/2 s/4 FUII Gal/hr 5 9.5 12.9 14.8 4.5 7.8 10.9 13.0 L/hr 18.9 36 48.8 56 17 29.5 41.3 49.2 Trailer information Model Tire size Tire type Load range Number of tires Lug pattern Wheel brand per trailer C20OD6RT 235/85-R16 Radial 2755 Ibs-each 4 8 hole Load Star Cummins Power Generation 1400 73rtl Avenue N.E. Minneapolis, MN 55432 USA Telephone:763 574 5000 USA Toll-free:877 769 7669 Fax:763 574 5298 Our energy working for you.Tm www.cumminspower.com Power ©2010 Cummins Power Generation.Cummins and PowerCommand are registered trademarks of Cummins Inc. Generation Specifications are subject to change without notice. S-1616(1/10)