Vistana Generator Submittal
iiiiiiiiiiiiiiiiiiiii111%4& TDI 75 "LUL) 0 - lob POWER SYSTEMS �AN! CTAYLOR EPA Certified / Stationary Emergency • OUTPUT POWEROPTIONS STANDBY RATING CONTINUOUS Make Voltage Alternator Phase Hertz kW/kVA Amps kW/kVA Amps 30%Voltage Dip Marathon 600 431 PSL6242 3 60 175/219 211 162/203 195 519 277/480 431 CSL6204 3 60 175/219 263 162/203 244 519 120/208 431 CSL6204 3 60 175/219 608 162/203 563 390 120/240 431 CSL6204 3 60 175/219 527 162/203 488 390 120/240 431 CSL6204 1 60 135/135 563 125/125 521 136 120/240 431 PSL6226 1 60 175/175 729 155/155 646 310 Marathon 277/480 431 CSL6206 3 60 180/225 271 166/208 250 664 120/208 431 CSL6206 3 60 180/225 625 166/208 577 498 120/240 431 CSL6206 3 60 180/225 542 166/208 500 498 120/240 431 CSL6206 1 60 160/160 667 150/150 625 185 Stamford 600 UC1274H17 3 60 175/219 211 162/203 195 840 277/480 UC1274H311 3 60 175/219 263 162/203 244 902 120/208 UC1274H311 3 60 175/219 608 162/203 563 723 120/240 UC1274H311 3 60 175/219 527 162/203 488 723 120/240 UC1274H311 1 60 142/142 592 131/131 546 485 120/240 UC1274H06 1 60 156/156 650 144/144 600 555 947 Industrial Park Drive • Clinton, MS 39056 • Phone (601) 922-4444 • Fax (601) 922-0800 •www.taylorpower.com application and engineering data POWER SYSTEMS Engine Data Air Requirements Manufacturer Perkins Air Filter(s)Type Dry Model 1106D-E70TAG4 Combustion Air Flow: CFM (m3/min) 543.85 (15.40) Aspiration Turbocharged Cooling Fan Air Flow: CFM (m3/min) 9963.1 (282.1) Charge Air Cooling System Air-to-Air Maximum Air Intake Restriction EPA Tier 3 Clean: in. H2O (kPa) 16.05 (4.00) Arrangement Inline, 4-Cycle Dirty: in. H2O (kPa) 32.11 (8.00) Firing Order 1-5-3-6-2-4 Exhaust System Displacement: L (in.3) 7.01 (427.78) Gas Temperature: °F (°C) 948.2 (509.0) Bore: mm (in.) 105.00 (4.13) Gas Flow: CFM (m3/min) 1210.2 (34.2) Stroke: mm (in.) 135.00 (5.32) Max Exhaust Back Pressure: in. H2O (kPa) 60.20 (15.00) Compression Ratio 16.8:1 Exhaust Outlet Size: in. (mm) 4.56 (115.90) BMEP: psi (kPa) 288.80 (1991.20) Net Horsepower 267.2 Sound Level Rated RPM 1800 Open Unit Without Exhaust: dBA 3.2 ft(1 M) 98.8 Governor Isochronous Filters and Quantity Speed Regulation +0.28% Air Cleaner Quantity 1 Engine Liquid Capacity Oil Filter(s) Quantity 1 Oil System: qt. (L) 18.49 (17.50) Fuel Filter(s) Quantity 2 Cooling System Capacity: gal (L) 5.55 (21.00) Fuel Consumption - 1250C Engine Electrical At 100% of Power Rating: gal/hr(L/hr) 12.76 (48.30) Electric Volts: DC 12 At 75% of Power Rating: gal/hr(L/hr) 10.25 (38.80) Cold Cracking Amps 925 At 50% of Power Rating: gal/hr(L/hr) 6.23 (23.60) Battery(s) Required 1 At 25% of Power Rating: gal/hr(L/hr) 3.78 (14.30) Fuel System Fuel Consumption - 1050C Fuel Injection Type Electronic CRIN2 At 100% of Power Rating: gal/hr(L/hr) N/A Fuel Pump Rate: gal/hr(L/hr) 104.61 (396.00) At 75% of Power Rating: gal/hr(L/hr) N/A Pump Maximum Suction Head: -68 At 50% of Power Rating: gal/hr(L/hr) N/A in. H2O (kPa) .23 (-17.00) At 25% of Power Rating: gal/hr(L/hr) N/A Pump Maximum Pressure 40.13 (10.00) Cooling System Head: in. H2O (kPa) Max Fuel Inlet Temp.: °F (°C) 167.00 (75.00) Rejection to Charge Cooler: kW(BTUM) 36.6 (2081.4) Recommended Fuel Low Sulfur Diesel Rejection to Coolant&Oil: kW(BTUM) 85.0 (4833.9) Coolant Flow: gal/min (L/min) 44.9 (170.0) GENERAL GUIDELINES FOR DERATION:Altitude:Derate 0.5%per 100m(328 ft.)Elevation above 1000m(3279 ft.)Temperature:Derate 1.0%per 10°C(18°F)temperature above 25°C(77°F) RATINGS:All three-phase units are rated at 0.8 power factor.All single-phase units are rated at 1.0 power factor. 125'RATINGS: 125'apply to installations served by a reliable utility source.The standby rating is applicable to varying loads for the duration of a power outage.There is no overload capability for this rating.Ratings are in accordance with ISO-3046/1,BS 5514,AS 2789,and DIN 6271. 105'RATINGS: 105'ratings apply to installations where utility power in unavailable or unreliable.At varying load the number of generator set operating hours is unlimited.A 10% overload capacity is available for one hour in twelve.Ratings are in accordance with ISO-8528/1,overload power in accordance with ISO-3046/1,BS5514,AS2789,and DIN 6271.For limited running time and base load ratings consult the factory.The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. alternator and controller data M<tAV:;qS Alternator Data Features Manufacturer Marathon . NEMA MG1-32, BS5000, and IEC 34-1 compliant; CE&CSA Certified and UL Listed Type PMG . Self-ventilated and drip proof construction Insulation NEMA Rise/Temp NEMA H/125°C . Two-thirds pitch stator and skewed rotor Hertz 60 • Wet wound, epoxied field windings Phase 3 • Designed to withstand overspeeds of up to 125% . Hybrid analog/digital voltage regulator RPM 1800 . Under frequency protection Leads 12 . Under frequency indication light Amortisseur Windings Full . Less than one cycle response time CFM Cooling Required 1100 • Over excitation protection . Over excitation indication light Voltage Regulator PM500 . Easy access front-panel adjustments Sensing Three Phase . Over voltage protection shutdown Voltage Regulation, No Load - Full Load 0.5% . Analog input for paralleling Optional 0.25%Regulation DVR2000E+Available Alternator Data Features Manufacturer Stamford . BS EN 60034, BS5000,VIDE 0530, NEMA MG1-32, IEC34, CSA C22.2-100, and AS1359 complaint Type PMG . IP23 enclosure Insulation NEMA Rise/Temp NEMA H/125°C . Dynamically balanced to exceed BS6861:Part 1 Grade 2.5 Hertz 60 vibration standard . Quality assurance to BS EN ISO 9001 Phase 3 . Self-ventilated and drip proof construction RPM 1800 . Two-thirds pitch stator and skewed rotor Leads 12 • Heavy duty bearings . Fully guarded Amortisseur Windings Full . Overexcitation protection CFM Cooling Required 1308 . Under frequency protection Voltage Regulator MX341 • Analog input Sensing Single Phase . Overvoltage protection . Paralleling compatible Voltage Regulation, No Load - Full Load 1.0% . Single-phase sensing DGC2020 Digital Controller . Integrated engine-genset control,protection,and metering @§R • Microprocessor allows for exact measurement,setpoint adjustment,and timing functions . Front panel 3 position controls and indicators enable quick and simple operation . Emergency stop push button and an Alarm Horn with silence button . Awide temperature-range liquid crystal display(LCD)with backlighting ©O�► w . SAE J1939 Engine ECU communications O . Remote RS-485 communications for Optional RDP-110 Remote Annunciator . 4 programmable contact inputs and 10 contact outputs(2 ADC rated) a A . Modbus Communications with RS-485,Battery Backup for Real Time Clock,UL recognized, CSA certified,CE approved,HALT(Highly Accelerated Life Tests)tested . IP 54 Front Panel rating with integrated gasket and NFPA 110 Level 1 Compatible. . Manual Override Keyswitch Analog Controller with Emergency Bypass Key Switch . Automatic CANBUS Engine Control . Oil Pressure,Water Temperature,Battery Voltage and RPM Gauges Automatic Gauge Zeroing on Shutdown . AC Voltage,Frequency,Percent of Load,and Run-Time Metering T"`° . 3-Position Auto-Off-Manual Control Switch . LED Status Lights:Low Oil Pressure,High Temperature,Overcrank,Overspeed,&Engine Start standard features and options POWER SYSTEMS ® Standard Features: Warranty • Heavy Duty Steel Base . Battery Charging Alternator 2 Year Standard . Vibration Isolators . Factory Powder Coating 5 Year Comprehensive . Oil Drain Valve with Extension . Factory Test . Battery Rack& Cables . Owner's Manual . High Ambient Unit Mounted Radiator Controller Options Miscellaneous Options: DGC-202OHD Controller . Battery Charger . Pad Type Battery Heater Fiber Optic Ethernet(DGC-2020HD) . Coolant Drain Kit . Battery Heater Blanket w/Thermostat RS-232 Port& Generator Protection (DGC-2020) . Block Heater . Oil Pan Heater Flush or Surface Mount Remote Annunciator . Line Circuit Breaker . Generator Strip Heater Remote Mount Break Glass E-Stop Switch Narrow Skid Base Open Unit Options: . Radiator Duct Flange . Flex Exhaust . Critical Silencer . Wide Skid Base OVERALL SIZE: 98"L x 30"W x 62"H Approximate Weight: 3,500 lbs. �e Note: Dimensions and weights reflect standard open unit with no options and are subject to change. 0 0 0 O Standard Enclosed Unit Options: . Sound Attenuated Enclosure . Load Center, Lights & GFI Receptacle . Sub-Base Fuel Tank OVERALL SIZE: 136"L x 60"W x 78"H Approximate Weight: 5,500 lbs. Note: Dimensions and weights reflect standard enclosed unit with no options and are subject to change. m m Note: The above drawings are provided for reference only and should not be used for planning installation. Contact your local distributor for more information. 12/18