Loading...
HomeMy WebLinkAboutProduct Approval (2) 10/14/ 020 r Fkuida Building Code Online �p BCIS Home i Log In User Registration ', Hot Topics Submit Surcharge Stats @ Facts , publications ' Contact Us BCIS Site Map Links ' Search Product Approval 2vpliv-4 � Copy c Jq cell USER:PUhlk User Product ADproval Menu>Product.or Appllcatinn Search>A�}tlintlon Ust>Appticatioo De?all F r FL# FL28545-R3 CODE COMPLIANCE Application Type Revision �+T. L CIE COUNTY O� ®NT Code Version 2017 �7 V r Application Status Approved IBOCC w1c(/a r(i(� Comments Archived Product Manufacturer EAGLE ROOFING PRODUCTS,LLC Address/Phone/Email 1575 East CR 470 Sumterville,FL 33858 (800)400-3245 annettes@eagieroofing.com Authorized Signature Annette Sindar annettes@eagieroofing.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R.Priest Evaluation Report Florida License PE-74021 Quality=Assurance Entity UL LLC Quality Assurance Contract Expiration Date 01/30/2023 Validated By Locke Bowden P.E. Validation Checklist-Hardcopy Received Certificate of Independence FL28645 R3 COI ERP18001.1 2017 FBC Eval Eagle Armor final.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D 1970 2015 TAS 103 1995 TAS 110 2000 UL 1897 2012 Equivalence of Product Standards Certified By Sections from the Code httnc-llwww.flr�tidabUlid'1nt5.Ora/pTlpr avp dU.aspx?param=wGEVXCIvdDgs%2bYQ6%2fEgpc3po/o2b83HKggECiimSVvq%2bVa638SStwCJMzg8A%3d... 112 10/14/2020 Florida Building Code Online Product Approval Method Method I Option D Date Submitted 02/18/2020 Date Validated 07/18/2020 Date Pending FSC Approval 02/19/2020 Date Approved 04/07/2020 Sqrr!Tary of Produqs, FL 1 Modalr Number or Name Description ASTM D 1970,TAS 103 and FRSAfTRI April 2012(04-12) 1 28645.1 compliant,self-adhesive underlayment Limits of Use Installation instructions Approved for use in kVHZ:Yes FL28645 R3 11 ERP18001.2 2017 FBC Eval Eagle Armor Approved for use outside HVHZ:Yes —ft—na-1-p-df- Impact Resistant:N/A t Verified By:Zachary R.Priest PE-74021 Design Pressure:+0/-135 j Created by independent Third Party:Yes Other.See evaluation report for limits of use. Evaluation Reports FL28645 R3 AE EPP18001.2 201.7.FBC Eval Eagle Armor EDE)—L Of I Created by Independent Third Party:Yes Contact US::2601 Blair Stone Road,Tallahassee FL 32399 Phone:$50-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Er_[VacV_Staternent AccessibiliN Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If You have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Honda Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please crick h!y. Product Approval Accepts;MCI WN Efm Credit Card safe https://www.floridabuilding.org/pr/"pp _fitLaspx?param=wGEVXCMdDqso/o2bYQ60/.2fEgpr3p%2b83HKqgECnm5Vvq%2bVa63&JJtwCJMzq8AO/o3d... 2/2 Certificate of Authorization No. 29824 17520 Edinburgh Drive E E K \., Tampa,Ft_33647 _ q y pia (813)480-3421 °T`ECI�NIC.A L SERVICES, LLC EVALUATION REPORT FLORIDA BUILDING CODE,6EDITION(2017) Manufacturer: EAGLE ROOFING PRODUCTS FLORIDA LLC Issued January 15, 2020 1575 E CR 478 Sumterville,FL 33585 (800)400-4235 www.eagleroofing.com Manufacturing Location: Springville,AL Quality Assurance: UL LLC(QUA9625) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1504.3.1, 1507.1,1, 1507.3.3, 1523.1.1,1523.6.5.2.1 Properties: Physical properties REFERENCES Enti Report No. Standard Year PRI Construction Materials Technologies(TST5878) G01-1 95-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST5878) GGI-196-02-01 TAS 103 1995 TAS 110 2000 PRI Construction Materials Technologies(TST5878) GGI-201-02-01 ICC-ES AC152 2013 PRI Construction Materials Technologies(TST5878) GGI-202-02-01 ICC-ES AC152 2013 PRI Construction Materials Technologies(TST5878) GGI-211-02-01 ASTM D 1970 2015a TAS 103 1995 PRI Construction Materials Technologies(TST5878) GGI-212-02-01 UL 1897 2012 PRODUCT DESCRIPTION AND LIMITS OF USE Eagle-Armor Eagle-Armor is a 60-mil thick ASTM D 1970, TAS 103 and FRSAITRI April 2012 (04-12) compliant, self-adhesive underlayment constructed from a blend of highly flexible and elastic polymers, high melt bitumen, heavy weight polyester and high tensile glass reinforcement. The product is supplied in 2 sq.rolls with nominal dimensions of 39-3/8"x 65'8". Exposure on the roof deck shall be limited to a maximum 180 days. The maximum roof slope shall be 6:12 when the roof tiles are placed directly on the underlayment. Tiles shall be placed on loading boards or battens for roof slopes greater than 6:12. ERP18001.2 FL28645-R2 Page 1 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. r EAGLE ROOFING PRODUCTS FLORIDA LLC CREEKEagle-Armor . . TECHNICAL SERVICES, LLC PRODUCT APPLICATION Min.Roof Slope: 2:12 in accordance with the FBC Roof Deck: Plywood decks shall be in accordance with the FBC requirements. Roof decks shall have no more than 118"gap at abutting joints. Application: All underlayments shall be installed in accordance with the FBC. Substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the substrate shall be checked for protrusion and corrected prior to underlayment application. Prior to beginning installation, the underlayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The underlayment shall be installed with the release backer removed and pressed firmly into place to ensure complete contact with the substrate. The underlayment shall be installed with the roll length parallel to the eave, starting at the eave, and with 3" headlaps and minimum 6"endlaps staggered min.6-ft.from preceding course. In the HVHZ,the underlayment shall be installed over one of more plies of ASTM D 226 Type II or ASTM D 2626 organic felt with minimum 4"headlaps and minimum 6"endlaps in accordance with FBC Section 1518.3. It is permissible to backnail the underlayment 12-inches o.c. within the headlaps (nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the underlayment). Min.Application 40'F; Contact the manufacturer when installing at temperatures below the minimum Temperature: application temperature. Roof Coverings: The underlayment is permitted to be used with mechanically fastened metal roofing,clay and concrete roof tiles,slate shingles,asphalt shingles,photovoltaic shingles,and composite plastic shingles in accordance with the FBC. The underlayment is permitted to be used with adhered clay and concrete roof the using the following adhesives in accordance with the FBC. 1. ICP Adhesives Polyset AH160 2. Dow TILE BOND Roof Tile Adhesive 3. DAP Touch'n Seal StormBond Roof Tile Adhesive WIND RESISTANCE(NON-HVHZ ONLY) The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9. Underlayment System No.1 Roof Deck: Min. 19132-inch CDX plywood attached to wood supports spaced a maximum 24"o.c. Underlayment: Eagle-Armor shall be self-adhered in accordance with manufacturer's installation instructions to the fastened deck. The applied underlayment shall be rolled with a minimum 751b steel roller immediately following application. Maximum Design -135 psf Pressure: ERP18001.2 FL28645-R2 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61620-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. EAGLE ROOFING PRODUCTS FLORIDA LLC CREEK Eagle-Armor TECHNICAL SERVICES,LLC LIMITATIONS 1. Fire Classification is not within the scope of this evaluation. 2. Installation of the evaluated product shall comply with this report, the FBC, and the manufacturers published application instructions, Where discrepancies exist between these sources, the more restrictive and FBG compliant installation detail shall prevail. 3. The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. 4. The space under the deck area shall be properly ventilated in accordance with the FBC requirements. 5. All headlaps shall be installed to shed water from the deck. 6. The underlayment may be used as described in other current FBC product approval documents. 7. Design wind load pressures shall be determined for components and cladding in accordance with FBC 1609. 8. The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind load pressures for components and cladding. 9. Maximum Design Pressures for a given undeflayment shall meet or exceed the design wind loads determined for the roof assembly. 10. All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer. E 2020.01 .15 C IV No 74021 13:28:04 Z -0500' STATE CF 141 Z R Zachary R.Priest,P.E. ��'°SS Florida Registration No.74021 Organization No.ANE9641 ONA%—"�� CERTIFICATION OF INDEPENDENCE CREEK Technical:Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical.Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R.Priest, P.E.does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT ERP18001.2 FL28645-R2 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61620-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty,installation, recommended use, or other product attributes that are not specifically addressed herein.