Loading...
HomeMy WebLinkAboutDSED - OPC MB COMBO AN �IAQ ,, • • • • • • • • • 12" UNIVERSAL BASE .%,,,�`.•••••.',� � PLATE DETAIL � SY ACTUAL MENU BOARD SQFT 23.83 I~"� ,tBx �EE11I��'•., Dais M EN U BOARD MAX HEIGHT-6' 12"X 12"-3/4" (3)3/4"CONDUIT FOR ANCHORS 141 m II II I I � BOLT PATTERN LOW VOLTAGE AND No.67382 120v POWER . y 76" 5-0 I I I I iv 1TQo�R LOOP 6,_4„ ( � 5—0 M � / 71'• �. F REQUI �• CANOPY CANOPY WIDTH N /a�I�//JJ{� y/ •••�O R� )P'•• E" °R5 CA //'�J �� •••••••• NATURE UCY/�Y/ 1 JAI. 1-5 1 1 I I I I 10"X 10"X 3/16" J "-'Y CL=3 SQUARE STEEL POLE N o •i 0 - IL CONC.FOOTING — — 5o u 4" o A 4 SELF-RETURNING oN PIVOTING CANOPY This document has been * v , LED LIGHT SOURCE digitally signed and sealed by 3M� Christian Langley,PE on the =LL^^ 2 2 date noted in this digital c m signature. Printed copies of c°00 this document are not CC 00 = considered signed&sealed,& Z 0 C 66rr the signature must be verified om w on any electronic copies. = 28 Serial:45 759E OO F0 80 43 20 10 BB BC D2 J Solution Elements 20VOLT120AMP)WEATHERPROOF 10"X 10"X 3/16" Samsung OH55F Displays s.00 z.00 o "BOX WITH DISCONNECT SWITCH Digitally signed Lu •LED BLU o by Christian w SQUARE STEEL POLE CURB o •5TTem Tempered Glass o (Hss,Asoo/B) p GROUND Langley N •2500 nit o Date: o (2) DIGITAL MENU 2020.09.14 N BOARDS TOP OF FOOTING TO BE 15:31:41 -04'00' a IX IC BY OTHERSA z"BELOW TOP OF CURB N c� REAR ACCESS PANEL w 8"X611X8" BOX +I Y N CONDUIT FOR LOOP 36.00 Lu 5-0 m o 0- CO Deep c MOUNTING PLATE SET BACK p ANCHORS(4).J-BOLT °i Al � PEAKERS BY OTHERS ANCHORS(4) w 8"X6"X8" BOX ` U � L 3 LL -/+15 DEG OF SWIVEL 2 Lq w 3/4"THICK CONCRETE FOOTER OPTIONS(2500 P51): v II DRIVE THRU U o v STEEL PLATE SURFACE ~ •36"DIAxT-0"DEEP[AUGERED,WITH vi 36"DIAM (6)#5 BARS VERT&#3 TIES AT 12"O.C.] Ln m •3'-8"SO x 2'-6"DEEP[SPREAD,WITH X o In, (4)#5 BARS EACH WAY,TOP+BOT] E �7 SIDE VIEW (APPROACH) U FRONT VIEW (ELEVATION) SCALE : 1/2"= V-0" SCALE : 1/2"= V-0" ELECTRICAL NOTES Primary wire size-#12 TH W N a,Y Disconnect switch:at base of sign,20 amp single pole.Astronomical time clock at panel room or photocell c I� 1. PAINT TO MATCH ORANGE PMS 165 C,GLOSS FINISH Maximum load-16 amps 120 volts per circuit maximum circuit size 20 amps °1 2. PAINT TO MATCH PMS COOL GRAY 1 C,GLOSS FINISH per NEC 600-6lt Power supply-120v-277 Multi Volt 60w 12v DC 3. BLACK VINYL,ARLON 2100-03 Illumination-LED's in canopy top-ETISSL-Model 538091 1 1-3"Color Preference Edgelit o Downlight,8.5w-4501m v, II PMS VINYL/PAINT Conduit-minimum 1/2 v PMS 165-DUNKIN'ORANGE 3M#3630-3123 SOIL STATEMENT Total sign load-120 volts `o u° Visual inspection indicates 2,500 P.S.F. Total sign circuits 1 u o PMS 219-DUNKIN'PINK 3M#3630-1379 for which footings are designed.If a .. All components shall be U.L.approved N 0 3M#7125-41 bearing Capacity of less than 2,500 P.S.F. Ballasts shall have independent U.L.approval(fused where required) PMS COOL GRAY 1 C 3M#7725-41 ons s n compliance is encountered at site,the engineer should All installatihall be i liance count or local codes • p with NEC and state, y be notified before proceeding with work. All signs shall be bonded to building equipment bonding conductor per NEC 250 U av E NP1740 HILL AVENUE CUSTOMER: DESIGNER: Pam Reeves COPYRIGHT zole State County Florida o BY KEMP SIGN & � County of:Palm Beach it ox DATE: 09.01.2020 SERVICE. ALL � > w ACE� WEST PALM BEACH, FL p U N K I N , RIGHTS RESERVED The forgoing document was acknowledged 33407 before me day of ALL ELECTRICAL ES0000229 7 561-840-6382 TO BE U.L.LISTED r„ o 8$erv1Ce �� 903 E. PRIMA VISTA BLVD COMPONENTS AND Electrical Qualifier: Your Name Here,Notary Public u FAX: 561-840-6385 PT ST LUCIE FL , l SHALL MEET ALL Stephen M. Kemp My Commission Expires: '^ 0 ES0000229 / N.E.C.STANDARDS a Z 3 -Design requirements Code 2017 for use within&outside the High Hurricane Zone HVHZ.-This engineering certifies the structuralinte integrity ofthoses stems components,and/or other construction explicitly specified -Electrical notes details,&specifications provided and are the soleres responsibility oftheelectricalcontractor.Noelectricalreviewhasbeen erformedandnocertificationofsuchisintended.•Structuraldesi nmeetsre requirements AISC360-10 ADvl-15&NDS-15 General 9 q 9 ( ) 9 Velocity ( ) 9 9 Y S ty Y P P Y P P P Y P tY P 9 q • Notes: as applicable.•Steel components shall be coated,painted,or otherwise protected against corrosion per FBC Sec 2203.2/2222.6.•Alum components in contact with steel or embedded in concrete shall be painted or protected as prescribed in ADM1-15(la),or plastictneoprene spacers provided.•All exposed fasteners shall be S.S.or have a protective coating for corrosion protection.•All welding shall comply with AWS requirements.•Steel welds:E70xx electrodes.•Aluminum welds:4043 filler alloy.•Alum extrusions:6063-T6 or stronger,U.N.O.