Loading...
HomeMy WebLinkAboutEnergy code FORM R405-2014 copy FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method i Project Name: THE GRAND CARLTON Builder Name: WYNNE DEVELOPMENT Street: WYNNE DEVELOPMENT Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE,FL, Permit Number: Owper: Qp'S 9 1 ��p S Jurisdiction: Design Location; FL,West Palm Beach County:: ST.LUCIE COUNTY(Florida Climate Zone 2) 1. N6w construction or existing New(From Plans) 9. Wall Types(1437.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1250.00 ft2 b.Frame-Wood,Exterior R=11.0 187.33 ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1446.0 sqft.) Insulation Area 2 a.Under Attic(Vented) R=30.0 1446.00 ft 6. Conditioned floor area above grade(ft2) 1446 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(139.2 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 320 a. U-Factor: Dbl, U=0.54 99.23 ft2 SHGC: SHGC=0.25 b. U-Factor: Dbl, U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a.Central Unit 34.8 SEERA5.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.586. ft. Area Weighted Average SHGC: 0.250 14.Hot water systems 8. Floor Types (1446.0 sqft.) Insulation Area a. Electric Cap:40 gallons EF:0.970 a.Slab-On-Grade Edge Insulation R=0.0 1446.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Total Proposed Modified Loads: 53.72 C Glass/Floor Area: 0.096 PASS Total Baseline Loads: 54.66 �� I hereby certify that the plans and specifications covered by Review of the plans and O4Z$E Srg� this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED B Before construction is completed DATE: this building will be inspected for nli com pace with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. 5� with the Florida Energy Code. COD W'61 OWNER/ GF�NT' BUILDING OFFICIAL: DATE: \`�� �� DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 4/3/2017 6:45 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title: THE GRAND CARLTON Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 Lot# Owner: Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 135 Street: WYNNE DEVELOPME Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: ST.LUCIE COUNTY Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE Family Type: Single-family FL, New/Existing: New(From Plans) Comment: >i CLIMATE / IECC Design Temp Int Design Temp Heating Design (Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,West Palm Beach FL_W.EST_PALM_BEAC 2 44 90 70 75 316 60 Medium BLOCKS Number Name Area Volume 1 Entire House 1446 12514.8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 234 1872 No 2 1 1 Yes Yes Yes 2 WIC 54 432 No 0 1 No Yes Yes 3 MASTER BATH 63 504 No 0 1 Yes Yes Yes 4 M.BATH 56 448 No 0 1 Yes Yes Yes 5 KITCHEN 172 1376 Yes 0 1 No Yes Yes 6 BATH 45 360 No 0 1 Yes Yes Yes 7 BEDROOM 2 204 1632 No 1 1 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 526 5154.8 No 0 1 Yes Yes Yes 10 FOYER 50 400 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio BEDROOM 40 ft 0 234 ft2 ---- 0 1 0 2 Slab-On-Grade Edge Insulatio WIC 1 ft 0 54 ft2 ---- 0 1 0 3 Slab-On-Grade Edge Insulatio MASTER BATH 9 ft 0 63 ft2 ---- 0 1 0 i 4 Slab-On-Grade Edge Insulatio M.BATH 8 ft 0 56 ft2 ---- 0 1 I' 0 i 5 Slab-On-Grade Edge Insulatio KITCHEN 1 ft 0 172 ft2 ---- 0 1 0 I I 6 Slab-On-Grade Edge Insulatio BATH 5 ft 0 45 ft2 ---- 0 1 0 I 7 Slab-On-Grade Edge Insulatio BEDROOM 2 34.2 ft 0 204 ft2 ---- 0 1 ' 0 i 4/3/2017 6:45 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 i FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab-On-Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 ---- 0 1 0 9 Slab-On-Grade Edge Insulatio GREAT/DINING 47 ft 0 526 ft2 ---- 0 1 0 10SIab-On-Grade Edge Insulatio FOYER 7 ft 0 50 ft2 ---- 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V A # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Metal 1524 ft2 240 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC v # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) BEDROOM 30 Blown 234 ft2 0.1 Wood 2 Under Attic(Vented) WIC 30 Blown 54 ft2 0.1 Wood 3 Under Attic(Vented) MASTER BATH 30 Blown 63 ft2 0.1 Wood 4 Under Attic(Vented) M.BATH 30 Blown 56 ft2 0.1 Wood 5 Under Attic(Vented) KITCHEN 30 Blown 172 ft2 0.1 Wood 6 Under Attic(Vented) BATH 30 Blown 45 ft2 0.1 Wood 7 Under Attic(Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 8 Under Attic(Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic(Vented) GREAT/DINING 30 Blown 526 ft2 .0.1 Wood 10 Under Attic(Vented) FOYER 30 Blown 50 ft2 0.1 Wood WALLS Adjacent Space CavityR-Val Width Height Sheathing Framing Solar Below Et R 1 N=>SE Exterior Concrete Block-Ext InsiHEDROOM 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0 2 S=>NW Exterior Concrete Block-Ext Ins(HEDROOM 4.1 18 0 8 0 144.0 ft2 0 0 0.5 0 3 W=>NE Exterior Concrete Block-Ext Ins(dEDROOM 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0 4 S=>NW Exterior Concrete Block-Ext InaMRSTER BA 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0 5 S=>NW Exterior Concrete Block-Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 6 N=>SE Exterior Concrete Block-Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 7 N=>SE Exterior Concrete Block-Ext In0EDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.5 0 I! 8 E=>SW Exterior Concrete Block-Ext InfiffDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.5 0 _ 9 SE=>W Exterior Concrete Block-Ext In!flEDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.5 0 10 S=>NW Exterior Concrete Block-Ext InfiffDROOM 2 4.1 4 0 8 0 32.0 ft2 0 0 0.5 0 I 11 S=>NW Exterior Concrete Block-Ext InsillAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.5. 0 12 N=>SE Exterior Concrete Block-Ext InsGiREAT/DINI 4.1 26 0 8 0 208.0 ft2 0 0 0.5 0 4/3/2017 6:45 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 13 W=>NE Exterior Concrete Block-Ext InsOREAT/DINT 4.1 21 0 8 0 168.0 ft2 0 0 0.51 0 14 N=>SE Exterior Concrete Block-Ext Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0 15 E=>SW Exterior Concrete Block-Ext Insul FOYER 4.1 6 0 8 0 48.0 ft2 0 0 0.5' 0 _16 N=>SE Exterior Frame-Wood GREAT/DINI 11 23 5 8 187.3 ft2 0.23 0.5 0 DOORS Vi # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E=>SW Insulated FOYER None .28 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 W=>NE 3 Metal Low-E Double Yes 0.54 0.25 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 S=>NW 5 Metal Low-E Double Yes 0.54 0.25 6.9 ft2 1 ft 0 in 1 ft 4 in None None 3 E=>SW 8 Metal Low-E Double Yes 0.54 0.25 23.2 ft2 1 ft 0 in 1 ft 4 in None None 4 N=>SE 12 Metal Low-E Double Yes 0.54 0.25 36.8 ft2 1 ft 0 in 1 ft 4 in None None 5 W=>NE 13 Metal Low-E Double Yes 0.55 0.25 40.0 ft2 10 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 315ft2 315ft2 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000385 1460.1 80.16 150.74 .2656 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 �i i 4/3/2017 6:45 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 I I FORM R405-2014 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation' 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS ----Supply— —Return--- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 '320 ftz Attic 80 ftz Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolin Jan Feb Mar ( ]Apr Ma X Jun X Jul ri Au Se Oct [ ]Nov Dec Heating HJan HFeb Mar [ ]Apr L May L Jun L Jul Augi I SepOct HX Nov X DecVentin Jan Feb X Mar [X]A r [ Ma [ Jun [ Jul Aug Se [X]Oct [X]Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM. 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 i �i v 4/3/2017 6:45 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 I FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: THE GRAND CARLTON Builder Name: WYNNE DEVELOPMENT Street: WYNNE DEVELOPMENT Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE, FL, Permit Number: Owner: Jurisdiction: .Design Location: FL,West Palm Beach COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. it Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. .Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 4/3/2017 6:45 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 i I I II FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. ills WYNNE DEVELOPMENT, FT. PIERCE, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1250.00 ft2 b.Frame-Wood, Exterior R=11.0 187.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ; ft2 4. Number of Bedrooms 2 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types Insulation Area a. Under Attic(Vented) R=30.0 1446.00 ft2 6. Conditioned floor area(ft2) 1446 b.N/A R= ft2 7. Windows- Description Area 11. .N/Aucts R R ft2 a. U-Factor: Dbl, U=0.54 99.23 ft2a.Sup:Attic,Ret:Attic,AH:Attic 6 1320 SHGC: SHGC=0.25 b. U-Factor: Dbl,U=0.55 40.00 ft2 SHGC: SHGC=0.25 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 34.8 SEER:15'.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 34.8 HSPF:8150 Area Weighted Average Overhang Depth: 3.586 ft. Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14.Hot water systems a.Slab-On-Grade Edge Insulation R=0.0 1446.00 ft2 a.Electric Cap:40 gallons EF:0.97 b.N/A R= ft2 c.N/A R= ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building T>ilE Sr Construction through the above energy saving features which will be installed (or exceeded) `ETA in this home before final inspection. Otherwise, a new EPL Display Card will be completed ;'''% =` �•�o'V'4, based on installed Code compliant features. a ._� _ _ v Builder Signature: ���� Date: \` o �i', a n Address of New Home: �0 5� S;? City/FL Zips P-S'(-e •S i *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient! mortgage (EEM) incentives if;you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321'i) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. Fo information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. • I i 4/3/2017 6:45 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 1 i I M f I R - - wrightsoft® Project Slulrnmary ��� �® oae Entire House py By,: QUICK CALCiS, INC. 317 ST.LUCIE LN.,FT PIERCE,qL 34946'Phone:172�66',-fi799 Fax 772-466-6796. Email:QUICKC 4LCS@AO .COM. Project In-formation a.. For: THE GRAN D CARLTON WY NE DEVELOPMENT, FT. PIERCE, FL Notes: i Design • • Weather. Fort-Pierce, FL, US Winter Design-Conditions SL mmer Design Conditions Outside db i 42 OF Outside'db 90: OF Inside db I 70 .°F Inside db. 75 OF Design TD 28 °F Design TD 15 OF Daily range I L Relative;humi Jity 50 % Moisture diffe ence 61 gr/Ib Heating Summ ryi Sensible Cooling Equipment-Load Sizing Structure 17848 Btuh Structure j 17520 Btuh Ducts 15654 Btuh Ducts i 8536 Btuh Central vent(0 cf ). i 0 Btuh Central vent(O cfm) ; 0 Btuh Humnone I idification ; 0 .Btuh Blower 0 Btuh Piping ; 0 Btuh Equipment load 23503 Btuh. Use marufac urer's data i n Rate/swing m Itiplier 0.95 Infiltration Equipmenf se stole load 24753 Btuh Method Simplified Latent Coolin E quip merit Load Sizin Construction quality Average g q p g Fireplaces 0 Structure 3203 Btuh Ducts . I 2318 Btuh j Central vent( cfm) 0 Btuh. Heatingg coolingg. (none) I Area(ftz) 1446 1446 Equipment laterit load ; 5521 Btuh Volume(ft3) 12511 12511 Air changes/hour 0.45 0.23. Equipment total load 30274 Btuh Equiv.AVF(cfm) 48 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary. Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC536A"030 Cond ZHBC536A*030 AHRI ref 7914$85 Coil F'X4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling l 24360 Btuh Heating output 34600 Btuh @ 47°F Latent cooling 1 10440_ Btuh Temperature rise 27. OF Total cooling1 34800 Btuh Actual airflow._ i1160. efm Actual air flo% 1160 cfm Air flow factor 0.049 cfm/Btuh Air flow factor, 0.045 cfm/Btuh' Static pressure 0.50 in H2O Static pressurg 0.50 in H2O Space thermostat Load sensible iheat ratio 0.83 Capacity balance point 32 OF Backup: Input=7 kW, Oui put=23009 Bt h, 100 AFUE I Calculations a proved byACCA to meet all requirements of Manual J 8th Ed. j „� - - wrights T[` I j 2017-Apr-11 09:29:38 Right-Suite®Universal 2017.17.0.14 RSU08101 Page 1 ..uick Calcs\Document THE GRAND CARLTON i1446.rup Calc=MJ8 Front Door faces: N I I I II ' I , - -wrightsok Right-J R Worksheet Date:� Entire House D By: QUICK CAILCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,It.34946'Phone:7721661,6799 Fa)c 772-466-6796 Email:QUICKCALCS@Aa L.COM 1 Room name Entire House I BEDROOM 2 Fosed wall 156.2 ft i 49.0 ft 3 Room height 8.7 ft d 8.0 ft heat/cool 4, Room dimensions 11.0 x 297.0 ft 5 Room area j 1445.5 ft2 297.0 W! Ty Construction U-value Or HTM Area (W) . Load Area (ftz)j Load number (Btuh/ftz°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) . Heat Cool I Gross NIP/S Heatl Cool Gross N/P/S Heat Cool 6 :13A-0acs 0143 n ! 400 2;55 503 465 ! ,; 1 i62 1184 72 72 '288 183 4A5 tom O T/0 n 2156 19r31 38 0 , 15 730 0'` Q . :0 ;'0 13AAocs 0143 a 4.00 2.55 128 83 212 0 0 0 0 �---G 1A-c1orn 1.270 e 1 35.56 87.29 24 2 848 2082 0 0 0 0 11 �D 11DO 0.390 a 1 10.92 11.31 21 21 229 238 0 0 0 0 W.'- 13A-4ocs 0:143-s 4.00 255 34 34 136 86 0 0 0 0 W 13A-4ocs 0.143 s i 4.00 2.55 360 353 1414 899 216 216 865 550 L- G 1Ao1om 1,270 s W,W 34,71 7 7 247 241 0 0 0 0 13A-4ocs 6143 w 400 2.55 310 237 9 603 104 72 288 183 1A�1om 1270 ::w 3556 55.21 ::32 .2;''. ,.,140 17-70 ,- 32 2 1140 1770: 4A5 tom O T/0 r w 2156 1931 41 41"r• ,. $B0 788. 0 I 0 0 0' P 12C-0sw. •0 091 2.55 1.28 192 192 489 246 0 0 0 0 C .16A.M. - 0 032 = 0 90 232 1446 1446-i `•- 1295' 3354 297 297 266 689: F 22A-tpl 0.989 27.69 0.00 1446 156 4325 0 297 49 1357 0. {: . .. i. i I I 6 c)AED ecursion I I 918 I 627 Envelope loss/gain I I I 149,61 13349 4204 4003 12 a). Infiltration . 28187 791 848 232 b) Room ventilation 10 0 0 0 13 Internal gains: Occupants @ MO 6 1380 3 i .690 Appliances/othe� 2000 0 Subtotal(lines 6 to 13) I 17848 17520 5053 4925 Less edemal load 0 0 0 0 Less transfer 0 0 0. 0 Redistribution I 0 0 0 0 14 Subtotal 17848 17520 5053 ' 4925 15 Duct loads I 32% 49% 5654 8536 32% I 49% 1601 2400 Total room load 23563 26056 6653 7325 Airrequired(cfm). 1100 1160 328 326 Calculations alJProved by ACCA to meet all requirbmentS of Manual J 8th Ed. c -�-_wcightsoft'' � 2017-Apr-11 09:29:38 I Right-Suite®Universal 2017 17.0.14 RSU08101 Pa e 1 ...ulck Calcs\DocumentMTHE GRAND CARLTON j1446.rup Calc=MJ8 Front Door faces: N g I I -f-wrightsoft Right-JO WorkSheet Date: Entire House Date QUICK CALCS, INC. By: 317 ST.LUCIE LN.,FT.PIERCE, !FL 34946 Phone:77216 I 799 Fax 772-466-6796 Email:QUICKCALCS AOL.COM ! 1 Room name WIC KITCHEN 2 Bposed wall O ft i O ft 3 Room height 8.0 ft heat/cool 8.0 ft I heat/cool 4 Room dimensions 6.0 x 9.0 ft 11.0 x 172.0 ft 5 Room area I 54.0 ftz 172.0 ft? Ty Construction U-value Or HTM Area (ft-) (Load .Area (ft�I . Load number (BtuhlfV-°F). (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh j Heat Cool Gross WP/S Heal Cool Gross N/P/S Heat Cool 6 13A-0ocs; 0143 n" 4;00 255 0 0' 0- 0 0;. 0 0 0. '4A5Zom. 0.776 n 21:56 19 31 0 0 r. 0 0 0 ; ;'0 0.1. '_.0 13A-4ocs 0.143 e I 4.00. 2.55 0 0 0 0 0 0 0 0 IA-c1om 1.270 e 35.56 87.29 0 0 .0 0 0 0 0 0 11 r-D- 11DO 0.390 e 10.92 11.31 0 0 0 0 0 0 0 0 W.:.. 13AAocs 0:143 s .. I 4.00: 2:55 0 0 0.: 0 0 _ W 13A-4ocs 0.143 s I 4.00 2.55 0 0 0 0 0 0 0 0 I-G 1Ac1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A46cs .0143 4.00 '2.55 0 0 0 0 0 I 0 0 0 1Ac1om 1270 .w -35661 55.21 0 0 ' 0 0 0 0 0 0 0770 ;.W 2156 19.31' - 0 0 0 0 0 . U 0 ;, .::.'0 P 12C-0sw 0.091 2.55 1.28 0., 0 0 0 64 64 163 82 C 16A 30md'; 0.032 D 90 2.32 54 54 48 ` - 125 172 t . 172 154 399 F 22A-tpl 0.989 27 69 0.05 54 0 0 0 172. 0 0 0 I I I , i 1 a 6 c)AED excursion I I -9 -170 Envelope loss/gain I I 117 317 311 12 a) Infiltration � o o o 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 ; 0 Appliances/othe� 0 2000 Subtotal pines 6 to 13) I I I �48 117 317 2311 Less extemal load 0 0 i -0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 117 I 317 2311 15 Duct loads 1 32% 49% 1 51 57 32% ; 49% 100 1126 Total room load 174 418 3437 Air required(cfm) �3 8 j 21 153 Calculations a proved by ACCA to meet all re uiremeni of Manual J 8th Ed. - - wrightsoA- 2017-Apr=11 M29:38 I Right-Suite®Universal 2017 17.0.14 RSU08101 Page 2 ...uick CaIcs\D6cumenMTHE GRAND CARLTON71446.rup Calc=MJB Front Door faces: N ! I I • - Job. wrightsoft° Right-JRD Worksheet Entire House Date' QUICK 6 CS, INC. BY ;! 317 ST..LUCIE LN.,FT.PIERCE,FL 34946.Phone:772-166I-6799 Fax 772-066-6796 Email:QUICKCALCSa(AgL:COM i 1 Room name 1 BATH I BEDROOM 2 2 Eqosed wall 5.0 ft i 34.2 ft 3 Room height 8.0 ft heat/cool 8.0 ft I heat/ccol 4 Room dimensions 9.0 x 5.0 ft 1.0 x 203.5 fit 5 Room area 45.0 ft= 203.5 ft? Ty Construction u-value. Or HTM Area (ft2) (Load Area (ft2)� Load number (Btuh/ft-*F) (Btu 2) or perimeter (ft) - (Btuh or perimeter. (ft) (Btuh) i, Heat Cool Gross N/P/S Heafl Cool Gross N,/P/S Heat- Cool 6 V�I 13A�ocs 0143 n. 4 00 255 °40 < 40 60 `: 102 128 128 513 326: L'`^ 4A5 tom: 0 770. n 21 56 1931 0 0 0 0 0 0 0 0 13A-4ocs 0.143 a 4.00. 2.55 0 0 0. 0 80 56 225 143 IA-c1om 1.270 a 35.56. 87.29 0 0 0 0 24 2 848 12082 11 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 13A=4ocs 0143. se- I -40 2:55 0 `0' 0 0 34 ! 34, 136 86. V�1 13A-0ocs 0143 s 4.00 2.55 0 0 0 0 32 32 128 81 L--G 1Ac1om 1.270 s ( 35.56 34.77 0 0 0 0 0 0 0 0 13A4ws 0143 w 4'00 255 0 0 0 0 0 0 0 0 1Ac1om - 1270 w 3556 5521 0 0 0 0 0 0 p p mom" 21:56 19 Al 0 0, 0 .0,-,. : 0 0 '0 0 P. 12C-0sw. 0.091 - 2.55 ,. ,1,28, 0 .0 0 0 0 0 0 C z16A 30mii 0 032 0:90 232 45:::: Q 45 40 104 204 204 182 472 F 22A tpl 0 989 - 27.69 0.00 45 5 38 0 204 34 g46 0 I' i I it . 7 � 6 c)AED exursion I I I I -16 Envelope losslon . I I ( 339 1901 2978 3106 12 a)'. Infiltration . 187 24 593 1 162 b) Room ventilation 10 0 0 j', 0 13 Internal gains: Occupants @ I I 230 0 0 1 230 Appliances/other I p p Subtotal pines 6 to,13) . I I 45 214 I 3571 3498 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 i._ p 14 Subtotal 425 214 I 3571 3498 15 Duct loads 32% 49% i35 104 32% 1 49% 1131 1704 Total room load I 01 318 4702 5203 Air required(cfm) I 28 14 232 232 Calculations ar proved b ACCA to-meet all r uirement5 of Manual J-8th Ed. !. . - wrightsolft' 2017-Apr 11 M29:38 1 Right-Suite®Universal.2017 17.0.14 RSU08101 Pa e 3 ...ulck Calcs\Document\THE GRAND CARLTON 1446.rup Calc=Mil Front Door faces: N 9 i 1 ,, l - - wrightsoft9 Right-4J R Worksheet yob: Entire Douse Date:; QUICK Cl CS, INC. By: 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772 66 799 Fax 7724666796 Email:QUICKCALCS AOIL.GOM 1 Room name I LAUNDRY j GREAT/DINING 2 Exposed wall 3 Room height I 8.0 ft 6.0 ft eat/cool 9.8 ft 47.0 ft heat/cool 4 Room dimensions i 7.0 x 6.0 ft j1.0 x 526.0 ft 5 Room area 42.0 ft2 526.0 ftz: Ty Construction U-value Or ; HTM Area (ft2) Area (ft2)'. Load number (Btuh/ft--°F) (BtutVft2) or perimeter (ft) �oadl tuh) or perimeter (ft) (Btuh Heat Cool Gross N/P/S Heatl I Cool Gross N/P/S Heat Cool 6 13A flocs _ 0143 `ri 400 2 55 0' 0 0::. 0 255 217 869 `552 �: 4A5 tom 0 770 .ri: 2156 19,31 '0 0':. 0 - 0. ' 38.`- j 0 815 730, 1 Ti93A4ocs 0.143 e I 4.00. 2.55 0 0 0 0 0 0 0 0 1Ac1om 1.270 a 1 35.56 87.29 0 0 0 0 0 0 0 0 11DO 0.390 e j 10.92 11.31 0 .0 0 0 0 0 0 0 W.- '13A4ocs 0:143 se I 4:00 2.55 0 0 0 0 0 13A4ocs 0.143 s 4.00 2.55 48 48 192 122 0 0 0 0 t-G 1A-c10m 1270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A4ocs 0143 'w 4 00 2.55 0 0 0 0 206 165 661 .420 1Ac1om:; 1270 w. 35`56 55.21 0 0 0: 0 0 0 jo 0 _21.56 ::19.31 0 0 ,.. 0,: 0 41 41 880 `788: P 12C-Osw . 0.0911 2.55 1.28 56 56 Q_ 72 0. C 16A=30mtl.,_ '0'032 _ :0.90 IM 42 42 i . 38 . -.97 526 1 . -526 '47� ,::,1220 F 22A-tpl f 0.9 27.69 42 0.00 6 66 0 526_ 47 1302 0 1. . . i : j 6 c)AED excursion _22 668 Envelope loss1gain I I I 539 276 4997 4379 12 a) Infiltration I 104 28 + 997 273 b) Room ventilation 10 0 0 0 13 Internal gains: Occupants @ I 230 0 0 2 ; 460 Appliances/othe{ 0 0 Subtotal(lines 6 to 13) I I 643 298 j 5994 5112 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution ! 0 0 0 0 14 Subtotal 643 298 j 5994 5112 15 Duct loads l 32% 49% 2b4 145 32% 49% 1899 2490 Total room load 846 443 7892 7602 Air required(cfm) 42 20 390 338 Calculations a I ved b ACCA to meet all requirement of Manual J.8th Ed. 1 411- wcig htsoft' I 2017-Apr-11 09:29:38 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 4 uick Calcs\Documents\THE GRAND CARLTON-j1446.rup Calc=MJ8 Front Door faces: N j I I I wrightsoft• Right-MR,Worksheet Job: I Dat Entire ''use Date: QUICK CAI CS, INC. By: 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-�66 6799 Fax 772-466-6796 Email:QUICKCALCS AgL.COM 1 Roam name j FOYER M.BATH 3 R=d wall 8.0 ft 7.0 ft eaUcool 8.0 ft i 8.0 ft heat/cool 4 Room dimensions 1.0 x 50.0 ft 7.0 x 8:0 ft 5 Room area 50.0 ftz 56.0 ftz Ty Construction U-value Or HTM Area (ft-) Load Area (ft Load number (Btuh/ftz-"F) (Btuh/ftz) or perimeter (ft) Btuh) or perimeter (ft) (Btuh) i Heat Cool Gross N/P/S Heatl Cool Gross WKS Heat Cool 6 13A4ocs. 0 UZi h 4:00 2 55 8 , 8 32 20 _ :RAS2om :0770 n 2f:56 19.31 0 0 : 0 0 0 0 0 0 13A-4ocs 0.143 e i 4.00 2.55 48 27 108 69 0 i 0 0 0 1A-c1om 1.270 e 1 35.56 87.29 0 0 j 0 0 0 0 0 0 11 11D0 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W .13A-flocs 0.143 se 4.00 255 0 0 0 0 0 0 0 0 yJ 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 64 57 228 145 t-G 1A-c1om 1270 s ' 35.56 34.77 0 0 0 0 7 7 247 241 13A�ocs 0143 W 4.00 2 55 0 0 0 .0 0 I 0 0 0: IA-o1om 1 270 m 35:56 55;21 0 0 0" 0 '0' { 0 0 0. 4A52om c A 770 W` 21:56 19$1 0 0 0 0 0• 1 0 0 0 P 12C-0sw. 0.091 7 2,55 1,28 72 72 IM 92 0 0 0 0 C', ;16A 30ihtl" 0 032 ,090 2.32 50' 50 45': 416 - 56 56 50 .130 F 22A tpl 0.9 - 27.69 0.00 50 7 194 0 56 8 222 0 �. . I r _ .. 6 c)AED excursion I I -39 -38 I Envelope loss/gain I I I 7�2 496 747 478 12 a) Infiltration 121 33 138 38 b) Room ventilation 10 0 0 0 i 13 Internal gains: Occupants @ 230 0 0 0 Appliances/other 0 p Subtotal Oines 6 to 13) I I 913 529 885 . 516 Less extemal load 0 0 i 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 9 3 529 885 516 15 Duct loads 32% 49% 2I89 258 32% 49% 280 251 Total room load 1202 787 1166 768 Air required(cfm) 59 35 1. 58 34 Liculations a roved b ACCA to meet all requirement of Manual J 8th Ed. .� -�- wrightw 2017-Apr-11 09 29:38 �LrA � Right-Suite®Universal 2017 17.0.14 RSU08101 Page 5 ...uick Caics\Documents THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N I I F I . I wri h Duct S item Sulma g tsoft 1 Date: Entire House By,: I � QUICK CALKS,INC. 317 ST.LUCIE LN.,FT.PIERCE,IfL 34946 Phone:.772�666 799:Fax 772-466-6796 Email:QUICKCALCS@AdL.COM Project - Information I I For. THE GRAD CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL i , External static pressure Heating Cooling 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O: . 0 in H'20 Available.statia pressure .0.50 in H2O 0.50 in H2O Supply/return available pressure 0.2$0/0,250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.285 in/100ft 0.285 in/100ft Actual.airflow 1160 cfm 1160 cfm Total effective length(TE ) 176 ft SupplyBranch Design Htd Clg Design . Diam. H x W Duct Actual; . . Ftg.Egv. Name (Btuh) (cfrr1) I (cfm) FR (in) (iri) Matl Ln(ft) Ln(ft) Trunk BATH h 560 �8 14_ 0.364 4.0 Ox8 VIFx 22.4 115.0 st1 BEDROOM 2 h 4702 232. 232 0.360 7.0 Ox 0 VIFx 23.9 115.0 SO BEDROOM-A h 3327 1�4 163 0.300 6.0 Ox0 VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 Ox0 VIFx 40.6 ! 135.0 st2 FOYER h 1202 59 35 0.505 4.0 Oxf VIFx 4.0 95.0 .GREAT/DINING h 3946 195 169 0.300 7.0 Ox0 VIFz 31.8.1 135.0 st2 GREAT/DININGA h 3946 195 169 0.300 7.0 OxC VIFx 31.8 ' 135.0 st2 KITCHEN c 3437 21 153 0.379 6.0 Ox 0 VIFx 17.0 1 .115.0 st1 LAUNDRY h 846 42 20 0.361 4.0 Ox 01 VIFx 23.3 i 115.0 st1 M.BATH-A h 768 8 34 0 0 Ox0 VIFx 0 ! 0 wlc c 174 �3 8 0.309 4.0 Ox0 VIFx 27.0.1 135.0 st2 I SupplyDetail Table I II I Trunk Htg Cig Design Veloc -DI M H x W Duct . Name Type I. (cfm) (ofm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 721 672 0.285 918 12.8 0 x 0 VinlFlx st1 st1 Peak AVF I 1043 �1691. 0.285 1020 14.0 0 x 0 VinlFlx f I I i I I i I I I I � , r i I 2017-Apr-11 09:29:38 �,. wrightso , Right-Suite®Urtllivel sal 2017 17.0.14 RSU08101 Pagel ...uick CaIcs\Documents THE GR i ND CARLTON-1446.rup Calc=MJB Front Door faces: N j 'I I I I r L. a I - I I I I Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist. Duct Name Size(in) (clfm) (cfm) I (ft) FR . . (fpm) (in) (in) Opening',(in) Matl Trunk I� rb1 Ox0 . 11.60' 1160 0 0 0 0. Ox 0 VIFx � i I ji I I I j I,I I i it ' i l I I I I �I i I 1 I I . I I i I. { it I I I li I I wri htso I 2017-Apr-1109:29:38 9 � Riight-Suite®Urlivelrsal 2017 17.0.14 RSU08101 Page 2 ...uick CalcsWocuments THE GRAND CARLT N rI? Calc 446.ru =MJ8 Front Door faces: N I � ' i I i