HomeMy WebLinkAboutProduct info GENERAC� a ;s, GUARQIANO SERIES . 16/20/22 W JUL t � Residential Standby Generators St.tiUc►,a count;-,FL. Air-Cooled Gas Engine INCLUDES: • True Power"' Electrical Technology Standby Power Rating a Two Line LCD Multilingual Digital _ Models G007036-0,G007037-0(Aluminum-Bisque)- 16 kW 60 Hz Evolution"" Controller(English/Spanish/ Model G007035-0(Aluminum-Bisque)- 16 kW 60 Hz French/Portuguese) Models G007039-0, G007038-0(Aluminum-Bisque)-20 kW 60 Hz • Two Transfer Switch Options Available: Models G007043-0,G007042-0(Aluminum-Bisque)-22 kW 60 Hz 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. 6 See Page 4 for Details. �► Electronic Governor e System Status&Maintenance int9rv91 Y r Indicators Sound Attenuated Enci GENERAC • Flexible Fuel Line Conn ctor ST.'LUCIE COUNTY BUILDING DIViSION • Direct-To-Dirt Compost Mountin PVIEWE® '` �► Natural Gas or LP Gas §t�d��QQ svOR�O i O c�d � rrr ATE `t — LISTED �� ��w��=�r' 0 5 Year Limited Warran PLAN s AND PERMIT Note:CUL certification orgy applies to unbundled units and units packaged with �,p limited circuit switches.Units packaged with the Smart Switch are UL certified in Capability to be instal{ d wi f P 'l W N JOB OR theuSAmiy. 0C a building* ILL BE MADE *Only If located away from doors,windows and fresh air Intakes, and unless otherwise directed by local codes. FEATURES O INNOVATIVE ENGINE DESIGN&RIGOROUS TESTING are at the heart of Generaes O SOLID-STATE,FREQUENCY COMPENSATED VOLTAGE REGULATION: success in providing the most reliable generators possible.Genstar's G-Force engine This state-of-the-art power maximizing regulation system is standard on lineup offers added peace of mind and.rellability for when you need it the most The all Genstar models.It provides optimized FAST RESPONSE to changing G-Force series engines are purpose built and designed to handle the rigors of load conditions and MAXIMUM-MOTOR STARTING CAPABILITY by extended run times in high temperatures and extreme operating conditions. electronically torque-matching the surge loads to the engine. Digital voltage regulation at t1%. O TRUE POWER'" ELECTRICAL TECHNOLOGY:Superior harmonics and sine ways O 811IGLE SOURCE SERVICE RESPONSE from Genres extensive dealer form produce less than 596 Total Harmonic Distortion for utility quality power.This allows network provides parts and service know-haw for the entire unit,from the i confident operation of sensitive electronic equipment and micro-chip based appliances, engine to the smallest electronic component. such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES:Long fife and reliability are PROTOTYPE TESTED v` NEMA MG1.22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this V SYSTEM TORSIONAL TESTED d MOTOR STARTING ABILITY confidence is that the GENERAC product line Includes Its own transfer systems and controls for total system,compatibility. W GENERAC �t7�3ss un PRGMi/iIE link •RditM a.LLS"mMp 0-0. Xft. GENERAL r 16/20/22 kW features and benefits Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings helps the engine • run cooler,reducing oil consumption resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance and longer engine life.Now featur- ing up to a 2 year/200 hour oil change Interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulates the output voltage to±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers your vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near your existing distribution panel for simple,low-cost installation. Evolution" Controls • Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy,at-a-glance status Indication In any condition. • Two-line LGD multilingual display Provides homeowners easily visible logs of history,maintenance and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load,setpoint approximately 5 seconds, • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload, • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph.Hinged key docking root panel for security.Lift-out front for easy access to all routine maintenance Items.Electrostat- Ically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to preventdnjuries. • Small,compact,attractive Makes for an easy,eye appealing Installation,as close as 181 away from a building. ■illi „i��,�r - �� ��idii���1 installation System • 1 it(305 mm)flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. • Direct-to-dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. • Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine,prolonging engine life. GENERAC 16/20/22 kW specifications Generator CD G007035.0,G007036.0, 6007038.0,G007039-0 G007042-O,G007043.0 Model G007037-0(16 kW) (20 kW) (22 kW) Rated Maximum Continuous Power Capacity(LP) 16,000 Watts* 20,000 Walls' 22,000 Rated Maximum Continuous Power Capacity(NG) 16,000 Watts* 18,000 Walls* 19,500 Rated Voltage 240 240 240 Rated Maximum Continuous Load Curren(—240 Volts(LP/NG) 66.6/66.6 83.3/75 91.6/81.3 Total Harmonic Distortion Less than 5% Less than 5% Less than 5% 3 of Main Line Circuit Breaker 70 Amp 100 Amp 100 Amp Phase 1 1 1 Number of Rotor Poles 2 2 2 Rated AC Frequency 60 Hz 60 Hz 60Hz Power Factor 1.0 1.0 1.0 Battery Requirement(not included) 12 Volts,Group 26R 540 CCA Minimum or Group 35AGM 650 CCA Minimum Unit Weight(lb/kg) 406/186 448/203 466/211 Dimensions(L x W x H)irUmm 48 x 25 x 29/1218 x 638 x 732 Sound output in dB(A)at 23 it(7 m)with generator operating at normal load" 66 66 67 Sound Output in dB(A)at23111'.(7 m)with generator in Quiet-Test'"low-speed exercise mode** 58 58 58 Exercise duration 5 min 5 min 5 min Engine Type of Engine GENERAC G-Force 1000 Series Number of Cylinders 2 2 2 Displacement 999 cc 999 cc 999 cc Cylinder Block Aluminum w/Cast Iron Sleeve Valve Arrangement Overhead Valve Overhead Valve Overhead Valve Ignition System Solid-state w/Magneto Solid-stale w/Magneto Solid-stale w/Magneto Governor System Electronic Electronic Electronic Compression Ratio 9.5:1 9.5:1 9.5:1 Starter 12 Vdc 12 Vdc 12 Vdc Oil Capacity Including filler Approx 1.9 gVi.8 L Approx.1.9 g1/1.8 L Approx.1.9 gV1.8 L Operating rpm 3,600 3,600 3,600 Fuel Consumption Natural Gas ! l it3/hr(m3/hr) 1/2 Load 218(6.17) 204(5.78) 216(6.12) Full Load 309(8.75) 301(8.52) 310(8.78) Liquid Propane ft3/6r(gal/hr).[I/hr] 1/2 Load 91.6(2.52)[9.53] 86(2.31)[8.99] 93.2(2.56)[9.701 Full Load 106.8(2.94)[11.11] 129.6(3.56)[13.48] 140(3.81)[14.65] Note:Fuel pipe must be sized for full toad.Required fuel pressure to generator fuel Inlet at all load ranges-3.5-7°water column(7-13 mm mercury)for natural gas,10-12*water column(19-22 mm mercury) for LP gas.For Btu content,multiply 10/hrx 2500(LP)or 1113/hr x 1000(NG).For Megaloule content,multiply ms/hr x 93.15(LP)or ma/hr x 37.26(NG) Controls 2-Line Plain Text Multilingual LCD Display Simple user Interface for ease of operation. Mode Bultons:Aulo i'I Automatic Stag on Utility failure.7 day exerciser. Manual Start with starter control,unit stays on.It utility fails,transfer to load takes place, Off ; Slops unit.Power is removed.Control.and charger still operate. Ready to Run/Mafntenance Messages Standard Engine Run Hours Indicat(on' i Standard Pro,mrivrelle start delay belween 2-1500 seconds Standard(programmable by dealer only) Utility Voltage Louffleturn to Utility Adjustable(Browrioul Selling) From 140-171 V/190-216 V Future Set Capable Fxerciser/Fxerclse Set Error Warning Standard Run/Alarm/Malntanance Logs j 50 Events Each Engine Slav(Sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). Starter Lock-out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Standard Charger FaulVMissing AC Warning Standard Low Bade /Bafte Problem Protection and Battery Condition Indication Standard ry ry ry Automatic Voltage Regulallon Y4'IN Over and Under Voltage Protection Standard Under-Frequency/Overload/Stepper Overcunenl Protection Standard Safety Fused/Fuse Problem Protection Standard Automatic Low Oil Presslue/High Oil Temperature Shutdown Standard OvercranVOverspeed(9 72;Hz)/rpm Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal FaultAncolreclWiling Protection Standard Common External Fault Capability - Standard Field Upgradable Fiimware ; , .. . :°- _ «« ;.'` Standard "Sound levels are Won from thefrontotthe generator.Sound levelstalren from other sides of the generator may be higher depending on Installation parameters.Rating definitions-Standby:Appliableforsupptying emergency power for the duration of the rNlily power outage.No overload capability Is available for this rating.(All ratings In accordance with BS5514,IS03046 and 01N6271).'M&dmum kllovoir amps and cu ent are mbiecito and limited by such factors as fuel Blu/megajoule content•emblem temperature,altbrde,engine powerand condition,etc.Mapmum power deaeasesabout 3.5 percenlfor each 1,000 feet(304.8 meters)above sea level:and also will decrease abouts percent for each 6'C(10'F)above 16°C(60`f). GENERACA 16/20/22 kW switch options Limited Circuits Switch Features Model G007036.0(16kW) • 16 circuits,breakers not included. No,of Poles 2 • Electrically operated,mechanically-held contacts for fast,positive current Rating(Amps) 100 Voltage Baling(VAC) 120/240,10 connections Utility Voltage Monitor(Fixed)' • Rated for all classes of load,100%equipment rated,both inductive and Pick-up 60% resistive. -Dropout 65% • 2 pole,250 VAC contactors. Return to utility approx.15 sec • 30 millisecond transfer time. Exercises bf-weekly for 5 minules*t Standard • Dual coil design. UL Listed Standard • Rated for both copper and aluminum conductors. Total Circuits Available 16• Main contacts are silver plated or silver alloy to resist welding and sticking. Tandem Breaker Capabilities 8 spacesCircuit Breaker Protected • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor Available RMS symmetrical 10,000 mounting flexibility. Fault current @ 250 Volts • Multi listed for use with 1"standard,tandem,GFCI and AFCI breakers from *Function of Evolution Controller Siemens,Murray,Eaton and Square D for the most flexible and cost effec- Exercise can be set to weekly or monthly tive install. Dimensions Height Width Ht H2 Wt W2 Depth In 26.75 30.1 10.5 13.5 6.91 Hz H, mm 679.4 764.3 266.7 343.0 175.4 Wire Ranges Conductor Lug Neutral Lug I Ground Lug nen, wz 1/0-#14 2/0-#14 1 2/0-#14 Service Rated Smart Switch Features Model GU07037-0(16 kW)/G007039-0(20 kW)/ • Includes Digital Power Management Technology standard(DPM). 6007043.0(22 kW) No.of Poles 2 • Intelligently manages up to four air conditioner loads with no additional Current Rating(Amps) 200 hardware. Voltage Rating(VAC) 120/240,10 • Up to four more large(240 VAC)loads can be managed when used in UlilityVoltage Monitor(Fixed)' conjunction with Smart Management Modules(SMMs). -Pick-up e0% -Dropout 65% • Electrically operated,mechanically-held contacts for fast,clean connections. Return to Ulitity' approx.13 sec • Rated for all classes of load,100%equipment rated,both inductive and resis- Exercises bi-weekly for 5 minutes' standard tive. UL Listed Standard • 2 pole,250 VAC contactors. Enclosure Type NEMA/UL 313 • Service equipment rated,dual coil design. Circuit Breaker Protected 22,000 • Rated for both aluminum and copper conductors. Lug Range 250 MCM-#6 • Main contacts are silver plated or silver alloy to resist welding and sticking. *Function of Evolution Controller • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mount- Exercise can be set to weekly or monthly Ing flexibility, Dimensions W, 200 Amps 120/240,1 e Open Transition Service Rated Height Width Depth Hz H, H1 H2 in 26.75 30.1 10.5 13,5 6.91 mm 679.4 764.3 266.7 343.0 175.4 oepm l-wa--� CENERAG 16/20/22 kW specifications Generator .� Madel 6007035-0,11007036-0, G007038.0,G007039-0 0007042-0,6007043.0 0007037-0(16 kW) (20 kW) (22 kW) Rated Maximum Continuous Power Capacity(LP) 16,000 Watts" 20,000 Walls' 22,000 Rated Maximum Continuous Power Capacity(NG) 16,000 Watts" 18,000 Watts" 19,500 Rated Voltage 240 240 240 Rated Maximum Continuous Load Current—240 Volts(UP/NG) 66.6/66.6 83.3/75 91.6/81,3 Total Harmonic Distortion fess than 5% Less than 6% Less than 5% r Main Line Circuit Breaker 70 Amp 100 Amp 100 Amp Phase 1 1 1 Number of Rotor Poles 2 2 2 Rated AC Frequency 60 Hz 60 Hz 6CHz Power factor 1.0 1.0 1.0 Battery Requirement(not included) 12 Volts,Group 26R 540 CCA Minimum or Group 35AGM 660 CCA Minimum Unit Weight(IbAg) 406/186 448/203 466/211 Dimensions(L x W x H)in/mm, 48 x 25 x 29/1218 x 638 x 732 Sound output in dB(A)at 23 it(7 m)with generator operating at normal load" 66 66 67 Sound output In dB(A)at 23tft,(7_m)with generator In.Quiet-Test"low-speed exercise mode'" 58 58 58 Exercise duration 5 min 5 min 5 min Engine Type of Engine GENERAC G-Force 1000 Series Number of Cylinders 2 2 2 Displacement 999 cc 999 cc 999 cc Cylinder Block Aluminum w/Cast Iron Sleeve Valve Arrangement Overhead Valve Overhead Valve Overhead Valve Ignition System Solid-state w/Magneto Solid-state w/Magneto Solid-state w/Magneto Governor System Electronic Electronic Electronic Compression Ratio 9.5:1 9.5:1 9.5:1 Starter 12 Vdc 12 Vdc 12 Vdc Oil Capacity Including Filler, Approx.1.9 gI/1.e L Approx.1.9 gV1.8 L Approx.1.9 g1/1.8 L Operating rpm 3,600 3,600 3,600 Fuel Consumption Natural Gas It'/hr(m3Por) 1/2 Load 218(6.17) 204(5,78) 216(6.12) Full Load 309(8.75) 301(8.52) 310(8.78) Liquid Propane fla/hr(gal/hr)[I/hr] 1/2 Load 91.6(2.52)[9.53] 86(2.37)[8.99] 93.2(2.56)[9.70] Full Load 106.8(2.94)[11.11] 129.6(3.56)[13.48] 140(3:87)[14.65] Note:Fuel pipe must be sized for full load.Required fuel pressure to generator fuel Intel at all load ranges-3.5-7°water column(7-13 mm mercury)for natural gas,10-12'water column(19-22 mm mercury) for LP gas.For Btu content,multiply fts/hr x 2500(LP)or ftshr x 1000(NG).For Mecajoule content,multiply malhr x 93.15(LP)er ma/hr x 37.26(NG) Controls 2-line Plain Text Multilingual LCD Display Simple user interface for ease of operation. Mode BullonsAulo I Automatic Start on Utility failure.7 day exerciser. Manual Start wilh starter control,unit stays on.If utility fails,transfer to load lakes place. Off Stops unit.Power is removed,Control and charger still operate. Ready to Run/Malntenance Messages Standard Engine Run Hours Indication ! Standard Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) Utility Voltage Loss/Retuin to Utility Adjustable(Brownout Selling) From 140-171 V/190-216 V Future Set Capable Fxerciser/Exerclse Set Error Warning Standard Run/Alarm/Malntenance Lags 50 Events Each Engine Start Sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). Starter Look-out Starter cannot re-engage until 5.sec after engine has stopped. Smart Battery Charger Standard Charger Fault/MissingAC Warning Standard Low Battery/Battery Problem Proleclion and Battery Condition Indication Standard Automatic Voltage Regulation with'Over and Under Voltage Protection Standard Under-Frequency/Overload/8tepper Overcunent Protection Standard Safety Fused/Fuse Problem Proleclion Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed(@ 72 Hz)/rpm Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal FaultAncorrect Wiring Protection Standard Common External Fault Capability @-` ._,_ Standard Fleld Upgradable Firmware I " Standard "Sound levels are L*A from the fronto)the generAr.Sound levels tairen from other sides of the generator may be higher depending on Installation parameters.Rating derinilims-Standby:Applicable for suppMng emergency power far the duration of the thilty power outage.No overload capability Is available for this rating.(All rndngsInaccordance with BS5514,IS03046and DIN6271).•MaximurnWrovoltampsandcunentaresubjecttoandlimitedbysuchfactorsasfuelBh&egajoule contentamblenttemperature,altitude,engine powerand wndldon,etc.Matomum power decreasesabout 3,5 percm1for each 1,000 feet(304.8 meters)above sea level:and alsowill decrease about 1 percent for each 6`C(10 IF)above 16°C(601F). t .r 4 GENERAL 16/20/22 kW switch options Limited Circuits Switch Features Model G007036.0(ifikW) • 16 circuits,breakers not included. No:of Poles 2 • Electrically operated,mechanically-held contacts for fast,positive Current Rating(Amps) 100Voltage Rating(VAC) 120/240,16 connections Utility Voltage Monitor(Fixed)' • Rated for all classes of load,100%equipment rated,both inductive and -Pick-up 60% resistive. -Dropout 65% • 2 pole,250 VAC contactors. Return to Utility' approx.15 sec • 30 millisecond transfer time. Exercises bi-weekly for 5 minutes'1 Standard • Dual coil design. UL Listed standard • Rated for both copper and aluminum conductors. Total Circuits Available 16 • Main contacts are silver plated or silver alloy to resist welding and sticking. Tandem Breaker capabilities s spaces • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor Circuit Breaker Protected Available RMS Symmetrical 10,000 mounting flexibility. Faun current @ 250 Vous • Multi listed for use with 1"standard,tandem,GFCI and AFCI breakers from *Function of Evolution Controller Siemens,Murray,Eaton and Square D for the most flexible and cost effec- Exercise can be set to weekly or monthly live install. Dimensions Height Width Ht H2 W1 W2 Depth in 26.75 30,1 10.5 13.5 6.91 nz mm 679.4 764:3 266.7 343.0 175.4 Wire Ranges Conductor Lug Neutral Lug Ground Lug oErn, Ya-a 1/0-#14 2/0-#14 2/0-#14 Service Rated Stuart Switch Features Model 0007037.0(16 kW)/G007039-0(20 kW)/ • Includes Digital Power Management Technology standard(DPM). 13007043.0(22 kW) No.of Poles 2 • Intelligently manages up to four air conditioner loads with no additional Current Rating(Amps) 200 hardware. Voltage Rating(VAC) 120/240,16 • Up to four more large(240 VAC)loads can be managed when used in Utility Voltage Monitor(Fixed)' conjunction with Smart Management Modules(SMMs). -oro-uur s5% • Electrically operated,mechanically-held contacts for fast,clean connections. Po Return to utility* approx. sec • Rated for all classes of load,100%equipment rated,both Inductive and resis- Exercises bi-weekly for 5 minutes' Standard d tive. p UL Listed Standard • 2 pole,250 VAC contactors. Enclosure Type NEMA/UL 3R • Service equipment rated,dual coil design. Circuit Breaker Protected 22,000 • Rated for both aluminum and copper conductors. Lug Range 250 MCM-#6 • Main contacts are silver plated or silver alloy to resist welding and sticking. *Function of Evolution Controller • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mount- Exercise can be set to weekly or monthly Ing flexibility. Dimensions W1 200 Amps 120/240,ie Open Transition Service Rated Height Width "2 Ht H2 W1 W2 In 26.75 30.1 10.5 13.5 6.91 mm 679.4 764.3 266.7 343.0 175.4 oevr" L--w2-� GENERAC 16/20/22 kW available accessories Mo.del# Product Description 0 Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac- G006463-4 Mobile Link'" cess to an Internet connection from a PC or with any smart device. You will even be notified via a-mail or text message when a change in the generator's status occurs. Available in the U.S,only. 0005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system.Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product(excluding PowerPact@). , The pad warmer rests underthe battery.Recommended for use It the temperature regularly falls below 0°F. 6007101-0 I Battery Pad Warmer (Not necessary for use with AGM-style batteries). . i 6007102-0 Oil Warmer Oil warmer slips directly over the oil filter,Recommended for use if the temperature regularly falls below 0°F. 6007103-0 'Breather Warmer The breather warmer Is for use in-extreme cold weather applications. For use with Evolution controllers only in climates where heavy Icing occurs. G005621.0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load Contact Kit you may not need.Not compatible with 50 amp pre-wired switches. Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air cooled generators.This offers a G007027-0-Bisque (Standard on 22 kW) sleek,contoured appearance as well as offering protection from rodents and insects by covering the rifting holes located in the base. If the generator enclosure Is scratched-or damaged,it is important to touch-up the paint to protect from G005703-0-Bisque Paint Kit future corrosion.The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic standby generator. G006873-0 Smart Management Modules are used In conjunction with the Automatic Transfer Switch to Increase Its Smart Management Module power management capabilities.It provides additional power management Ilexlbflity not found in any other (50 Amps) power management system. dimensions & PCs Dimensions shown are approximate.Refer to installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. aCu 121 Model UPC G007035-0 696471070354 G007036-0 696471070361 G007037-0 696471070378 V gri G007038-0 696471070385 92 G007039-0 696471070392 o a o -loll G007042-0 696471070422 G007043-0 696471070439 eE"eroevn_w MONTwsw G E N E RAC" Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 • generac,com ©2016 Generac Power systems,Inc:All rights reserved.An specifications are subject to change without notice.Part No.10000000194-D 10/24/16 i GENERAC 00 4 Smart Management GENERAC@ ACCESSORIES Modules (SMM) Model G006873-0 _:• ':,. GENE 'RAC j k� f .n•- n � WW LISTED DESCRIPTION Generac's Smart Power Management System is designed to optimize the performance of a standby generator.The system can consist of up to 8 individual Smart Management Modules(SMM).Unlike other load management systems that depend on another control device, the SMM modules are actually self- aware and operate autonomously. Frequency is the true measure of generator engine performance and does not need to factor in increased ambient temperatures, elevation changes or generator fuel type.The modules monitor the frequency(Hz)of the power being produced by Generac's standby generators and if It falls below a certain threshold,the module will automatically follow a power management algorithm to ensure that the generator is not overloaded. The modules can be set to a load priority between 1-8 or be set in a lock out only mode for loads that just simply do not need to run in an outage,therefore reducing the necessary size of the generator for a more cost effective solution. SMM SPECIFICATIONS PowerSupply Source............................................................................................................................................................................................................240 VAC(from Line input) SupportedVoltages..........................................................................................................................................................................................................................................240 VAC ContactorColl Voltage......................................................................................................................................................................................................................................240 VAC CoilVA Inrush. ................................................................................................................................. . .................................................................................................................30 CoilVA Seated.....................................................................................,..........................................................................................................................................,...................,....6.5 Poles-,,,,,, ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, ,2 ResistiveAmps.........................................................................................................................................................................................................................................................50 F/L Inductive Amps........................................................................................................................................................................................................................................... .....40 LackedRotor Amps.....................................................................................................................................................................................................................................240@240V UI50........................................................................................................................... ......... . ............,............,...........................................................I............... ..Yes EnclosureRating....................................................................................................... . .....,........................,..,,...............,.......................,............,..,....,...NEMA 3R GENERAC° Smart Management Modules (SMM) Dimensions and UPC W1 W2 — ► Model G006873-0 H1 6.17/156.8 Height(in/mm) O H2 2.36/60 W1 7.06/179.4 Width(in/mm) W2 4.72/120 H1 H2 Depth(in/mm) 3.7/94 Weight(lbs/kilos) 2,06/0.94 Shipping Weight(lbslkilos) 2.44/1.11 O UPC Code 696471068733 D1 O SWIM Controls (located behind the cover of the module) B C ILED ON=LOAD CONNECTED LOCKOUT LEO FLASH 1S=LOAD SHED PRIORITY LOAD ON LED FLASH 3S=30 MIN LOCKOUT 6 GENERATOR LED FLASH 6S=GEN LOAD LOCKOUT s 7 �-- LED OFF=NO MODULE POWER A ® ® Oo 0 0 LOCKOUT TEST DISABLED Pfiorlly Dial(A)— Sets module priority. Lockout Switch(B)— Prevents load from operating when system Is operating under generator power. Test Button(C)— Disables contaclor output for a specified time. LED(D)— Provides module status with easy viewing through the external viewing window located in the upper right,corner ol.lhe'module. Generac Power Systems,Inc. • S45 W29290 HWY..59, Waukesha,WI 53189 generac.com GENERAL° 02016 Generao Power Systems,Inc.Ag rights reserved.All specl0callons are subject to change wllhout notice. Bulletin OL7500-C 03/10/16 Site Selection and Preparation Section 3: Site Selection and Preparation Site Selection D '~O 5ft(1.52m) C 5ft(1.52m) �, E i l3 4.- 3 ft -O A 4-- 3 ft B(0.91 m) O (0.91 m) O t 3 f(0.91 m) B � B F G D Figure 3-9. Installation Clearances ID Description Comments A Top of generator — B Front and end clearance Minimum clear distances cannot include shrubs,bushes,or trees. C Rear clearance 18 in(45.7 cm)minimum clearance per NFPA testing,labeling,and Ilsting,unless state or local codes dictate otherwise. D Windows and openings No operable windows,doors,or openings in the wall are permitted within 5 ft(1.52 m)from any point of the generator. E Existing wall One-hour fire rated walls allow closer placement of the generator set.Confirm before Installation. F Removable fence Removable fence panels for servicing cannot be placed less than 3 ft(0.91 m)in front of the generator. G Overhead clearance 5 ft(1.52 m)minimum distance from any structure,overhang,or projections from the wall. DO NOT install under wooden decks or structures unless this distance Is maintained. Installation Guidelines For 60 Hz Air-Cooled Generators 11 -- ---_ _ - Site Selection and Preparation Install thegenerator ooi in its protective enclosure, —Theganenshormuntboinstalled nnulevel sur- outdoors where adequate u+outdoormvxadequabe cooling and ventilating air is face.The generator must hmlevel within eO.5in always available(Figure 3-1). Consider these factors: (13mm)all around. ° The installation of the generator must cnnnpk/ —The generator iotypically placed onpea gravel, strictly with ICC |FGC. NFRK37' NFRA54. y4FPA compacted soil, crushed stone,oraconcrete O8, and NFPA7Ostandards. pad. Check local codes busee what type|o aInstall the unit where air inlet and outlet openings required. Ifeconcrete pad iorequired, all appli- cable oodemehou|dbefoUovmed' wNwillnot become obstructed by leaysnow,mea, gnaon. snow, / ob. If prevailing winds will cause blowing or Installation Guidelines for Stationary Air-Cooled drifting, consider using awindbreak toprotect the Generators unit. NFPA 37 io the T�� National Fire Protection Install the generator on high ground where water kavoAssociation's standard for the installation and use of levels' not operate inurbesubjected tostanding water. stationary combustion engines. Its requirements limit the spacing ofanenclosed generator set from astructure or ! ° Allow sufficient room on all sides of the Qanensbzr vmaU(��o�p����0. for maintenance and een�o|nQ This unit (Figure ' ' NFRA'|/ 37' Section 4'1'4` Engines Located Outdoors- installed in accordance with any |mna|' state, or Engines, and their weatherproof houeinQo if provided' nsdknna| codes for minimum diebannamhonmther ' that are installed outdoors ehoU be located at least 5 � | ntruotunas | ' M ��nm��n�in\�{�o����5ft(1'�n) ! " (�|aamanow�ornthe ends and�ontofthe generator (1.52 from structures having combustible vvehe. A minimum must be 3 ft (0.91 ,n). This includes mhrubs, separation shall not berequired where the following � bushes, and trees. Clearance from the back ofthe conditions exist: | generator must be m minimum of 18 in (457 rnmo). 1The vv�|ofthe atmu�u[ehas a�ne Clearance at the top should be o minimum of5 ft ' ~-v~—~~ resistance rating ofmtleast one hour. p.54 nV from any structure, nvernang, or projections from the wall. 2^ The weatherproof enclosure is constructed of ° D<] NOT install noncombustible materials and it has been under decks oratn�utunao demonstrated that e hna within the enoh�aunm will there is at least 5 ft (1.52 m) of clearance not ignite combustiblematerials outside the ! above the generator, enclosure. ° \notaUthe unit where rain 0uttspouts, run-off, landscape inigatinn, water sprinklers, or Annex A--Explanatory Material sump pump discharge does not flood the unit or A4.1.4 [2) Means of demonstrating compliance are by spray the enclosure, including any air inlet orouUmeans�one of` full scale fire test orbvcalculation procedures. openings. Because of the limited mpaooa that are frequently * Install the unit where services will not be affected available for insbsUmiion, it has become apparent that or obstructed, including ooncea|ad, underground, omceod � �o� �� would be beneficial for many residential orcovered een�oeusuch ame|o��doo|.fuel, phone, and 'upm 'a| installations. With that in mind, the . air oondU0oning, or irdQmtion. This could affect manufacturer contracted with on independent testing warranty coverage. laboratory to run full scale fire tests to assure that the ° VYhene strong prevailing winds blow from one enclosure will not ignite combustible materials outside dinecUon, face the generator air inlet openings to the enclosure. the prevailing winds. NOTE: Southwest Research >noUtuha testing approves ° Install the generator amclose oopossible tothe fuel 18 in (457 mm) installation minimum from structure supply toreduce the length ofpiping. REMEMBER 3.1. [). Southwest Research Institute is a THAT LAWS OR CODES MAY REGULATE THE nationally recognized tblnj party testing and 8mUnQ DISTANCE AND LOCATION. In the absence of agency. local codes regarding placement orclearance, we The criteria was todetermine the worst case fire scenario recommend following these guidelines: within the generator and todetermine the iQnitobUihYof � Install the generator asclose eepossible tothe items outside the engine enclosure atvarious distances. transfer switch. REMEMBER THAT LAWS(]R The enclosure is constructed of non-combustible CODES MAY REGULATE THE DISTANCE AND materials, and the naau|ba and conclusions from the LQCAT|ON. ���nt testing |ob indicated that any fire within the 12 Installation Guidelines For 60 Hz Air-Cooled Generators � Site Selection and Preparation generator enclosure would not pose any ignition risk to Site Preparation nearby combustibles or structures, with or without fire service personnel response. " Loosda the mounting area as o|uoe as possible to the transfer switch and fuel supply. ° Leave adequate room around the area for service access (check local coda)' and place high enough (051 LWW BY;swftm tokeep rising water from reaching the generator. kmftft Sm Ante*,Tom� ° Choose anopen space that will provide adequate | and unobstructed airflow. WIT 3 00 01A MA*-P ° Place the unit a# air vents won't become clogged with |ea/ae, gr000, snow, or debris. Verify that WM 7 MD CHAR MAX,- exhaust fumes will not anter any building through eaveo, windows, ventilation fanm, or other air intakes(see Site Selection). ' ~ Ga|ecL the h/po of base, such ms--but not |knded Figure 3'2.Southwest Research Institute Marking, to—compacted soil, gravel, orconcrete, medesired or as required by |omy} kamm or codes. Verify h�w��oww»nmn�w�p4orgt0y��e�s����m*moodt�e�oxhim |oua|n�qu|ronn=n'v before selecting. ^�� Based onthis testing and the requirements ofNFB437. Sec 4.1.4.the guidelines for installation ofthe generators Material Sufficient for Level Installation listed above are changed to 18 in (457 mm) from the ^ Prepare erectangular area approximately 5in(127 back side ofthe generator bopstationary wall orbuilding nnnn) deep (A) and approximately in (162 mm)(C)' For adequate maintenance and airflow clearance, longer and' 'ider B) than the footprint of the the area above the generator should beat|ean�6�(1.82 generator. Verify ' ot the surface where the m)with o minimum of3ft(0.81 m) edthe front and ends generator will be mounted is compacted, |ave!ad, of the eno|osuny. This includes treso, whruba, and and will not erode over time.Aconcrete pad can ba bushes. Vegetation not in onnnpUoncm with these poured ifdesired qrrequired. clearance parameters could obstruct air flow. |naddition, exhaust fumes from the generator could inhibit plant growth. See Figure 3-1 and the installation drawing within the owner's manual for details. 10Automatic start-up. Disconnect utility power and render unit Inoperable before working on unit. Failure vudvsuwill result mdeath orserious Injury. (000181\ \��| .5&_ IFIRTNUCIRIS Asphyxiation. Running engines produce Figure 3-3. Compacted Soil mrGravel Pad carbon monoxide, a colorless, odorless, poisonous gas. Carbonmonoxide,nnot NOTE: |foconcrete pad ierequired,follow all applicable avoided,will.=="K| death w �=h w"souw» federal, state, orlocal codes. (000103) NOTE: Ifthe generator isnot set toOFF, it can crank and start aasoon mmthe battery cables are connected. |fthe utility power supply imnot turned off, sparking can occur at the battery posts and cause mnexplosion. - ' Installation Guidelines For 60 Hz Air-Cooled Generators 13 ' /