Loading...
HomeMy WebLinkAboutFl Energy eff code FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method I Project Name: WYNNE THE WINDSOR Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE, FL, Permit Number: Owner: U(.e"�g _4\� Jurisdiction: Design Location: FL,Fort Pierce County:: ST.LUCIE COUNTY(Florida Climate Zone 2) I 1. New construction or existing New(From Plans) 9. Wall Types(1432.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1224.00 ftZ b.Frame-Wood,Adjacent R=11.0 208.00 ftZ 3. Number of units,if multiple family 1 c.N/A R= ; ftz 4. Number of Bedrooms 3 d.N/A R= ftZ 5. Is this a worst case? Yes 10.Ceiling Types (1753.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1753.00 ftZ 6. Conditioned floor area above grade(ftZ) 1753 b.N/A R= ftz _ i Z Conditioned floor area below grade(ftZ) 0 11 Ducts R R ftZ 7. Windows(151.4 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 1 325 a. U-Factor: Sgl, U=0.54 111.36 ftZ SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.55 40.00 ftZ 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a.Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ftZ SHGC: 13.Heating systems kBtu/hr Effic ency d. U-Factor: N/A ftZ a.Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.850 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems 8. Floor Types (1753.0 sqft.) Insulation Area a.Electric Cap:40 gallonsEF:0.970 a.Slab-On-Grade Edge Insulation R=0.0 1753.00 ftZ b. Conservation features b. N/A R= ftZ None c.N/A R= ftZ 15.Credits Pstat Glass/Floor Area: 0.086 Total Proposed Modified Loads: 53.74 PASS I Total Baseline Loads: 53.87 I hereby certify that the plans and specifications covered by Review of the plans and 04ZY4E ST,q?� this calculation are in compliance with the Florida Energy specifications covered by this �y _ O� Code. ` calculation indicates compliance iiq '$'12 with the Florida Energy Code. PREPAR D Ry. Before construction is completed r DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. with the Florida Energy Code. COD WSJ OWNER/A E T. BUILDING OFFICIAL: DATE: DATE: I - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. i I 4/3/2017 2:28 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 I FORM R405-2014 PROJECT Title: WYNNE THE WINDSOR Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot# Owner: Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 225 Street: THE WINDSOR Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: ST.LUCIE COUNTY Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: I I CLIMATE I / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume i 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes i Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M.BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yesl Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes I 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes ! Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ft2 ---_ 0 1 0 2 Slab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft2 -___ 0 11 0 3 Slab-On-Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft2 _-__ 0 1 0 4 Slab-On-Grade Edge Insulatio M. BATH 7 ft 0 61 ft2 ____ 0 1 0 I I 5 Slab-On-Grade Edge Insulatio LAUDRY 1 ft 0 36 ft2 0 1! 0 I I i 4/3/2017 2:28 PM EnergyGauge@)USA-FlaRes2014 Section R405.4.1 Compliant Software (Page 2 of 5 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab-On-Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft2 ---- 0 1 1 0 7 Slab-On-Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft2 ---- 0 1 0 1 � 8 Slab-On-Grade Edge Insulatio KITCHEN 11 ft 0 209 ft2 ---- 0 1 1 0 I 9 Slab-On-Grade Edge Insulatio BATH 5 ft 0 50 ft2 ---- 0 1 0 i 10SIab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft2 ---- 0 1 0 11SIab-On-Grade Edge Insulatio FOYER 9 ft 0 92 ft2 _--- 0 1 0 I 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 ft2 ---- 0 1 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) I 1 Gable or Shed Metal 1847 ft2 292 ft2 Light 0.6 No 0.9 No 0 18.4 I ATTIC i V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) MASTER BEDRO 30 Blown 224 ft2 0.1 Wood 2 Under Attic(Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic(Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic(Vented) M.BATH 30 Blown 61 ft2 0.1 Wood 5 Under Attic(Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood 6 Under Attic(Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood 7 Under Attic(Vented) DINING/GREAT 30 Blown 588 ft2 0.1 Wood 8 Under Attic(Vented) KITCHEN 30 Blown 209 ft2 0.1 Wood 9 Under Attic(Vented) BATH 30 Blown 50 ft2 0.1 Wood 10 Under Attic(Vented) HALL 30 Blown 25 ft2 0.1 Wood 11 Under Attic(Vented) FOYER 30 Blown 92 ft2 0.1 Wood 12 Under Attic(Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood I WALLS Adjacent SRAJahlp Wall Typepace Cavity Width Height Sheathing Framing Solar Belo w 1 NE=>W Exterior Concrete Block-Ext InsVASTER BE 4.1 16 0 8 0 128.0 ft2 0 0 015 0 I 2 SW=>E Exterior Concrete Block-Ext InIMWSTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.5 0 i 3 NW=>S Exterior Concrete Block-Ext InddASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 4 NE=>W Exterior Concrete Block-Ext InsMASTER BA 4.1 8 0 8 0 64.0 ft2 0 0 015 0 i I 4/3/2017 2:28 PM EnergyGauge@)USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 WALLS i Adjacent Cavity Width Height Sheathing Framing Solar Below Space a_va1 le Et n Et rea_ 5 NE=>W Exterior Concrete Block-Ext InsuM.BATH 4.1 7 0 8 0 56.0 ftz 0 0 0.5 0 _ 6 NE=>W Exterior Concrete Block-Ext InQEDROOM 2 4.1 12 0 8 0 96.0 ftz 0 0 0.5 0 i _ 7 SW=>E Exterior Concrete Block-Ext InEENNING/GRE 4.1 30 0 8 0 240.0 ftz 0 0 0.5 0 _ 8 NW=>S Exterior Concrete Block-Ext IndNNING/GRE 4.1 20 0 8 0 160.0 ftz 0 0 0.5 0 I _ 9 SW=>E Exterior Concrete Block-Ext InsuKITCHEN 4.1 11 0 8 0 88.0 ftz 0 0 0.5 0 10 NE=>W Exterior Concrete Block-Ext Insul BATH 4.1 5 0 8 0 40.0 ftz 0 0 0.5 0 11 SE=>N Exterior Concrete Block-Ext Insul FOYER 4.1 8 0 8 0 64.0 ftz 0 0 0.5 0 12 SW=>E Exterior Concrete Block-Ext Insul FOYER 4.1 1 0 8 0 8.0 ftz 0 0 0.5 0 13 NE=>W Exterior Concrete Block-Ext InRffDROOM 3 4.1 13 0 8 0 104.0 ftz 0 0 0.5 0 14 SW=>E Exterior Concrete Block-Ext InfiffDROOM 3 4.1 1 0 8 0 8.0 ftz 0 0 0.5 0 15 N=>SW Garage Frame-Wood BEDROOM 3 11 26 8 208.0 ftz 0.23 0.5 0 DOORS I i # Ornt Door Type Space Storms U-Value Width Height i Area Ft In Ft In 1 SE=>N Insulated FOYER None .39 3 3 6 8 21.7 ftz WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 NW=>S 3 Metal Low-E Single Yes 0.54 0.25 32.4 ftz 1 ft 0 in 1 ft 4 in Drapes/blindsi Exterior 5 2 NE=>W 5 Metal Low-E Single Yes 0.54 0.25 6.9 ftz 1 ft 0 in 1 ft 4 in None None 3 NE=>W 6 Metal Low-E Single Yes 0.54 0.25 16.2 ftz 1 ft 0 in 1 ft 4 in None None 4 SW=>E 7 Metal Low-E Single Yes 0.54 0.25 39.8 ftz 1 ft 0 in 1 ft 4 in None None 5 NW=>S 8 Metal Low-E Single Yes 0.55 0.25 40.0 ftz 8 ft 0 in 1 ft 4 in None None 6 NE=>W 13 Metal Low-E Single Yes 0.54 0.25 16.2 ftz 1 ft 0 in 1 ft 4 in Drapes/blinds' Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 806 ftz 806 ftz 26 ft 8 ft 11 � INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1636.1 89.82 168.92 .2598 7 I i I I � I i I i i 4/3/2017 2:28 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software (Page 4 of 5 FORM R405-2014 HEATING SYSTEM i # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump i Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 i sys#1 i HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None j SOLAR HOT WATER SYSTEM FSEC Collector Storage j Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 i DUCTS i / —Supply--- --Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 325 ft2 Attic 95 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar Apr Ma rj Jun X Jul rl Aug Se Oct [ ]Nov Dec Heatin HJan HFeb Mar E_�Apr I May Jun Jul Au Sep E Oct [ Nov H Dec Ventin Jan Feb X Mar [ A r May Jun Jul Aug [ Se [X]Oct [X]Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 781 78 Cooling(VVEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78. 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 681 68 PM 68 68 68 68 68 68 68 68 68 68 661 66 i i c I� I 4/3/2017 2:28 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 TABLE 402.4.1.1 I AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE,FL, Permit Number: Owner: Jurisdiction: Design Location: FL,Fort Pierce i COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. i The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. I Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. j The air barrier shall be installed at any exposed edge of insulation. i Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. j Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. I Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available 1 space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. i Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 4/3/2017 2:28 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. • I THE WINDSOR, FT. PIERCE, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul, Exterior R=4.1 1224.00 ftZ b.Frame-Wood,Adjacent R=11.0 208.00 ftz 3. Number of units,if multiple family 1 c.N/A R= ftZ 4. Number of Bedrooms 3 d.N/A R= ftz 10.Ceiling Types Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1753.00 ftz 6. Conditioned floor area(ftZ) 1753 b.N/A R= ft2 7. Windows- Description Area c.N/A R= ftz a. U-Factor: Sgl, U=0.54 111.36 ftZ 11.Ducts R ftZ SHGC: SHGC=0.25 a.Sup:Attic,Ret:Attic,AH:Attic 6 325 b. U-Factor: Sgl, U=0.55 40.00 ftZ SHGC: SHGC=0.25 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ftZ a.Central Unit 34.8 SEER:1!5.00 SHGC: d. U-Factor: N/A ftZ 13.Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 34.8 HSPF 8.50 Area Weighted Average Overhang Depth: 2.850 ft. Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14.Hot water systems a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1753.00 ftZ EF:0.97 b. N/A R= ftZ c. N/A R= ftZ b. Conservation features None 15.Credits Pstat I I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) .y��KgE SrgraO in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home:�9��� City/FL Zip: e�ce WS *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) Z38-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. i 4/3/2017 2:28 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 wri htsoft Project Summary 9 Da : Y . ° En#ire HoQuse By QUICK CA-CS,INjC. 317 ST'LUCIE LN.,FT.PIERCE,F .34946,Phone:772-4�6 r 799 Fax,772-466-6796. Email:QUICKCAL aS@/101.COM: . Project Information For. ' WYN qE DEVELOPMENT . THE WNDSOR, FT. PIERCE,FL �J 1 Noes: i i Desicin Information I Weatherl. Fort Pierce, FL, US i I Winter esign Conditions Summer Design Conditions Outside db 42 °F Outside db 90. OF Inside db. ' 70 OF Inside db; 75 OF Design TD 28 OF Design TD ! 15 OF Daily range ! L ., Relative-humic ity 50 Moisture difference 61 gr/lb He a ing'Summa Sensible C,00lin E ui ment:Load Sizing 9 q p g Structure 18467 Btuh Structure 1 17655 .Btuh Ducts 6190 Btuh Ducts 9340 Btuh Central vent(0 cfm 0 Btuh Central vent(C cfm) 0 Btuh (none) Humidification 0 Btuh Bloer(none, 0 Btuh Piping I 0 Btuh Equipment load 21657 Btuh Use man act re data n Rate/swi' g multiplier ! 0.95 nfiltratlOn Equipme f sensible load 25645 Btuh Method Slrn lified p Latent Cooling E ui merit Load Sizing 9 q . p Construction ualit g Fireplaces q Averag0 Structure j 2453 Btuh Ducts ! .2554 Btuh Central vent(0 cfm) 0 Btuh Heati g Cooling (none Area.(ft?) 1713 j 1753 Equipme t lat nt load L. 5007 Btuh Volume(ft3) 1471. 14741 Air changes/hour 0.38 0.20 Equipme it toti I load 30652 Btuh Equiv.AVF(cfm) 9II3 49 Req. tot I cap city at_0.70 SHR ! 3.1 ton Heating Equipment S�mmary Coc ling Equipment Summary Make Carrier Make Carrier Trade CARR,IERAIR COND TIONING Trade CARRIERAIR CONDITIONING Model 25HBC536A*030 Cond 2 HBC536A*030 AHRI ref 7914585 Coil F 4DN(B,F)037. ff AHRI ref 7 14585 Efficiency 18.5 HSPF Efficiencyy 12.0 EER, 15 SEER Heating input Sensible�cooli g. 24360 Btuh Heating,output 34600 Btuh @ 47 F Latent cooling : 10440. Btuh Temperature rise 27 OF Total cooing 34800_ Btuh Actual airflow 1160 cfm . Actual air flow 1.160. cfm. Air flow factor 0.047 cfm/Btuh Air flow factor I 0.043 cfm/Btuh Static pressure 0.50 in. H2O Static pressure 0.50 in H2O 1 Space thermostat. Load sensible eat ratio 1 0.84 Capacity balance p int 34 OF ; Backup: Input=7 kW; Output 23009 Btu 00 AFUE Calculations appr Ived byACCA to meet all requirement of Manual J 8th Ed. I - - wrightsoft•. 2017-Apr-10 V:19:28 Right-Suite®Uni er$al 201717.0.14 RSU08101 I. Page 1 ...k Calcs\Documents\WN NNE-THE WINDSOR- Ei`/ISED.ru' Calc=MJ8 Front_Door faces: N I i I I i - -wrightsoft* Right-J®Worksheet °b . Entire louse ' BY: BY� QUICK C� �CS, INC. 317 ST.LUCIE LN.,FT.PIERCE,Fi 34946 Phone:772-4 1799 Fax 772-466-6796 Email:QUICKCAL?S@/\O .COM 1 Room name I Entire Ouse MASTER BEDROOM 2 .=ad wall f 153.0 ft ' i . 45.0 ft 3 Room height 8.4 ft d 8.0 ft I heaticool 4 . Room dimensions 1 0 x 280.0 ft 5 Room area i 1753.0 ft' 280.0 ft' Ty Construction U- ue Or HTM Area : Load number Btuhlft�val °F 2 (fit) oad Area (ft2) ( ) (Btu or perimeter (ft) (ptuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat I Cool Gross N/P/S Heat Cool 6 13A4ocs 0143 -ne 4001 2.65. 488 448 .17 5. 1141 192 .j 192 769' 489 1Ac1om 1 270 ne_ 35.56 70:43 7 0 2 7 488. 0 D: 0 0 1Ac1om 'i 1 270 ne 3556' l' M43 16 0 1 1151 0 ] 0: KC : 1-270 :rie' 35:56 i .`45.24, 16 0 1. 739 11 13AAocs 0143 se 4.00 2.55 .64 41 1 5 105 0 0 0 0 T—D 11130 0 390 se 10.92 11.31 23 23 248 257 0 0 0 0 ;13A-0ocs, 0 143 sw 4:00' I 255 437 _:396 4 1007 56 56; 224 143 4A52om �0770 ••sw 21;5fi.r. 2T53 Al ; 8 3 - 1140 0 f 0 . 0 �1 13AAocs 0.143 nw 4.00 2.55 290 217 8 i7 551 112 79, 318 I 202 �--G 1A-c1om 1.270 nw 35.56 45.24 33 0 11 2 1478 33 0 1162 1478 I--G 4A5-2omd.. 0.770 nw 21.56 36.90 41 0 0 1505 0 0 0 0 P 12C-0sw.r, 0 091 = 2:`55. i ,.1628: `308 308 _764' 395.` 0`. 0 0 0 C 16A 30md 0.032 - 0.90 2.32 1753 1753 1 1 4067 280 i 280 251 650 F 2769 0:00 .1753 : .153 42 7':' 0 280 a �.:: 45 1246 0 • � i ,.. 1 j h { ;. 1 I. 6 c)AED mursion I I I 1360 1 600 Envelope loss/gain I I I 155 15385 3970 1 3561 12 a) Infiltration 2873 810 1 809 228 b) Room ventilation I0 0 01 0 13 Internal gains: Occupants @ I 230 2 460 0 0 Appliances/other I 1000 I 0 Subtotal Qines 6 to 13) I I I I 184E 7 17655 4779 3789 Less e#emal load 0 0 i 0 I 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1 7 17655 4779 3789 15 Duct loads 34% 53% 61E0 9340 34%' i 53% 1602 1 2005 Total room load 246 26995 1 6380 5794 Air required(cfm) 11E0 1160 i 300 249 I i Calculations a roved b !ACCA to meet all re uireMent of Manual J.8th Ed. P. wrigt�tso#t- j 2017-Apr 10 17:19:28 Right-Suite@ Un versal 2017 17.0.14 RSU08101 Page 1 k CalcsWocuments\W NNE-THE WINDSOR EVISED.rup Calc=MJ8 Front Door faces: i I I I i -�-wrightsoft° Right�Q Worksheet °b Entire House Date: By: QUICK CALCs, INC. 317 ST LUCIE LN.,FT.PIERCE, L 34946 Phone:772-16-1 799 Fax 772-466-6796 Email:QUICKCALCS@AO .COM j 1 Room name WIC M.BATH. 2 Exposed wall 0'ft 7.0 ft 3 Room height I 8.0 ft eat/cool 8.0 ft heat/cool 4 Room dimensions 7.0 x 9.0 ft 1.0 x 61.0 ft 5 Room area ( 63.0 ft2 61.0 ft2; Ty Construction U-value Or I HTM Area (ft2) oad Area (ft2)I Load number (Btuh/ft2-°F) (Btu 2) or perimeter (ft) (Ruh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S j Heat Cool Gross N/P/S Heat Cool 6 13A4ocs 0143 :ne 4;00 1 2:55 0 0 0 0 56 I 49 196 125 ;1A-c1om : 1 270 -ne 35:58 7,0:43 : 0 0 0 0 7 0; 247 988; 1A�1om,: A 270 ne.: 95;55 i 70:43. 0 0. 0.'_ A A :0 0 i I1 0, 1Ac1om =1.270 ne 35.5.B r 4524 p 0 O 0 0' j 0 0 . 0. 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 �D 11D0 0.390 se• 1092 11.31 0 0 0 0 0 f 0 0 0 13A-0ocs !:•_ 0.143 sw' 4 00 i 2.55 0 0 0 0: 0 0: 4A5tom 0.7,70•sw' 21.56,.1 .27:53 0. 0 0. 0. p , p '0 0. 13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0" 0 0 0 0 �-G 1Ac1om 1.270 nw 35.56 45.24 0 0 0 0 0 j 0 0 0 LL--GG- 4A5-2omd 0.770 nw 21.56. 36.90. 0 0 0 0 0 0. 0 0 P '-12C-0sw:: 0:091 2;55. I 1`28 0: .. 0,. 0.. -:0 " 0::. 0" =_0 0. C 16A-30md 0.032 0.90 Z32 63 63 146 61 61 55 142 F 22Prtpl 0`.989 :27% 0.00 :63 `.. ;0 .I 0 : 0 61 i 6 c)AED emursion I I I I -5 I -26 I Envelope loss/gain I I I 1F6 141 I 692 ! 729 12 a) Infiltration I I 0 0 I 126 35 b) Room ventilation 0 0 i 0 0 13 Intemal gains: Occupants @ j 230 0 0 0 i 0 Appliances/othe I 0 0 Subtotal pines 6 to 13) I I I I 6 141 f 817. I 764 Less extemal load I I 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 I 0 0 14 Subtotal 141 817 764 15 Duct loads 34% 53% 9 75 34% 1 53% 274 404 Total room load 75 216 1091 1168 Air required(cfm) 9 ! 51 50 i Calculations a7 roved b 'ACCA to meet all re uirements of Manual J 8th Ed. wrightsaft- I 2017-Apr=10 17:19:28 Right-Suite®On 5sal 2017 1,7.0.14 RSU08101 Page 2 k Calcs\Documents\ NNE-THE WINDSOR- EVISED.ru0 Calc=MJ8 Front Door faces: N I -�-wrightsoft- Right-A)Worksheet Job: Entire Krouse Byte: QUICK C� I CS, INC. j � 1 317 ST LUCIE LN.,FT.PIERCE,F 34946 Phone:772-4 6 i 799 Fax 772-466-6796 Ernail:QUICKCALCSgAu .COM 1 Room name LAUDRY i BEDROOM 2 2 • 5gwsed wall 01 ft 12.0 ft 3 Room height I 8.0 ft eaUcool 8.0 ft I heat/cool 4 Room dimensions 1 6.0 x 6.0 ft 15.0 x 12.0 ft 5 _ Room area 36.0 ft2 180.0 ftz! I Ty Construction U-value. Or 1 HTM Area (ftz) Load Area (ftz) Load number (Btuh/ft2--°F) I (BtuWft2) or perimeter (ft) ( tuh) or perimeter (ft) (Btuh) j Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat I Cool 6 -13AAocs 0.143 ne- 4 00 2.55 0 0 0- 0 96 i 80 319 l 203 1A c1om ', 1'.270 rie 35 56 70 43 0 0 0 0 0 ] 0,: 0 1A c1om 1.270 ne 35 56:. 70.43 :0 0 0 0 16 { 0: 581 ; 11 1 51 1Aclom 1:270 ne. 3556 45.24 0: 0 .. 0 0... 0.. 0 0 :.,0 11 V�✓ 13AAocs 0.143 se 4.00 2.55 0 0 0 0 0 I 0 0 0 D 11D0 ." 0.390 se 10.92 11.31 0 0 , 0 0 0 j 0 0 0 13A-0ocs:>..` 0.143 sw.: 4 00. 2i55 0. 0 0 0 0, I p`. 0 ;.0 :4A5 tom: 0:TI0 ;sw- 21.56 .. 2753 0 0 0 " 0. 0 0 0 - 0 13AAocs 0.143 nw 4.00 2.55 0 0 0 0 0 i 0 0 .0 IA-c1om 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 1 0 4A5.2omd 0.770 nw 21.56 36,90 0 0 0 0 0 � 0 0 0 P -I -0sw: 0:091'-- 2t55 r ":1:28. 0 0 0. 0.,'.- -r 0::. { ,o ::.-6: 0 C 16A-30md 0.032 - 0.90 2.32 36 36 32 84 180 180 161 ' .418 F. 2?A tpl "., 0.989 2T69 0.00 ,:. 36: 0 0 0 180 12 332 0 V. I a I i 6 c)AED excursion I I I I -3 -60 Envelope loss/gain I I I 32 81 1394 1711 12 a) Infiltration i 0 0 216 61 b) Room ventilation 0 0 0 0 13 Internal gains: I Occupants @ er 230 0 I 00 0 00 Subtotal pines 6 to 13) I 2 81 i 1609 1772 Less external load 0 0 0 0, Less transfer 0 0 0 0 Redistribution 6 14 6 14 14 Subtotal 8 95 1615 1786 15 Duct loads 1 1 34% 53% 1 3 50 34% 1 53% 541 1. 94.5 Total room load 1 145 2156 2730 Air required(cfm) 121 6 I 101 _ 117 (Calculations ap roved b ;ACCA to meet all re uirehienti of Manual J 8th Ed. A - Right-S 1- wcighYso 2017-Apr-10 17:19:28 .. uite®Un versai 201717.0.14 RSU08101 Page 3 k Calcs\Documents\ NNE-THE WINDSOR-REVISED.rp Calc=MJ8 Front Door faces: N 1 I i i I - -wrightsoft°. Right-A)Wolcksheet Job: { Entire House dace: QUICK ci LCs, INC. By: i 317 ST.LUCIE LN.,FT.PIERCE, C 34946 Phone:772 16!799 Fax 772-466-6796 Email:QUICKCALCS@AO .COM 1 Room name DINING/GREFApT RC OMi KrrCHEN 2 .E)q)osed wall 505 ft 1 11.0 ft 3 Room height 8.9 ft I ieat/cool 8.9 ft i heat/cool 4 Room dimensions 1.0 x 588.0 ft 19.0. x 11.0 ft 5 Room area 588.0 ft2 209.0 ft2 Ty Construction U-value or HTM Area (ft2) oad Area :(ft2)j Load number (Btuh/ft2-'F) (Btuh/ft2) or perimeter (ft) tuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Head Cool Gross N/P/S Heat Cool 6 13A-0ocs 0.143 •ne 4:00 2:55 0 0 0 0 0 0 0 I' 0 1A�1om 1 270 ne. 35.56 70.43 0 0 0 0 0_ 0 :0 0 1Ac1om : 1 276 ne, 35 56, 70:43 0 ' 0 0 0 0 0 0 1Ac1om 1270 ne: 35;56 - 45, 4 0 0 0. , 0 0 .0: 0 _ p 11 W, 13AAocs 0143 se 4.00 5 0 0 0 0 0 0 0 10 —D 2.5 11D0 0 390 se 10.92 11.31. 0 0 0. 0 0 � 0 0 0 13A flocs:: Q 143 s" I A. 255 267 226 3 574 98':: ] .:98 392 ) 249. :_4A5 tom A 770 sw; 21:56. 27.:53 41 22 8 3:: 1140 0 . { 0. 0 0 13A-4ocs 0.143 nw 4.00 2.55 178 137 649 349 0 0 0 0 1A-c1om 1.270 nw 35.56 45.24 0 0 I I0 0 0 0 0 0 4A5-2omd 0.770 nw 21.56. ; 36.90 41 _. 0 830 1505 0 0 0 0 P 12GOsw-. 009i 2.55. 128 . "0 0 - 0 0 116 176 295 148 C 16A 30md 0.032 0.90 2.32 588 588 527 1364 209 209 187 485 F 22A tpl 0 989 2769 0.00 588 50 ;1 0,: 209 ' .I 11 305 0. i. f ! .. I. i I i i 6 c)AED excursion I I I 1004 I -64 Envelope loss/gain I I I 151 6 5937 1179 818 12 a) Infiltration 1 282 220 62 b) Room ventilation to 0 0 0 13 Internal gains: Occupants @ I 230 2 460 0 0 Appliances/other) 0 1000 Subtotal(lines 6 to 13) I I I 61 6 6679 1399 1880 Less extemal load i 0 0 i 0 0 Less transfer 0 0 0 0 Redistribution 6 14 ! 0 0 14 Subtotal 6142 6693 j 1399 1880 151 Duct loads 34% 53% I 20 3541 34% 1 53% 469 995 Total room load 82 10234 1867 2875 Air required(cfm) 6 440 88 124 I Calculations ap r6ved b ACCA to meet all requirements requirelments of Manual J.8th Ed. .� wri F�tso 2017-A 17:19:28 Fa 9 r10 Right-Suite®Universal 201717.0.14 RSU08101 I p Page 4 k Calcs\Documents\W NNE-THE WINDSOR- EVISED.rup Calc=MJ8 Front Door faces: N i i - wr%ghtsoft* Right.4 Worksheet °b Entire use Date:': QUICK CAL CS, INC. By: i 317 ST.LUCIE LN.,FT PIERCE,F 34946 Phone:772-4i 61 799 Fax 772-46M796 Email:QUICKCALCS@AO .COM 1 Room name I BATH I HALL 2 Exposed wall 5.01 ft I O ft 3 Room height 1 8.0 ft eat/cool. 8.0 ft I heat/cool 4 Room dimensions 10.0 x 5.0 ft 5.0 x 5.0 ft 5 Room area 50.0 ft2 ! II 25.0 ft2 j Ty Construction U-value Or HTM Area (ft2) Joad Area (ft2) .Load number (Btuhlft2°F) (Btuh/ft2) or perimeter (ft) ( uh) or perimeter (ft) (Btuh) ! Heat Cool Gross N/P/S Heat I Cool Gross WP/S Heat Cool 6 13A-0ocs 0.143 ne 4 00 40 40 1 0. 102 0 b. 0 0 1Ac1om 1.270 ne 35 56: 70.43 0 0 0 0 0 0; :0 0 9A clom 1:270 ne 35 56 70.43 0 0 b 0 0 0 0 0: 1A�1om` 1:270 ..rie 35 56- 45:24 0 A 0 0 0. { 0: 0 U 11 VJJ 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 I—D 11DO 0.390 se, 10 92 11,31 0 0 0 0 0 0_ 0 0 13A�ocs;i: 0.143 sw 4:00 255 p p p- `. 0 0; :I 0 U 0 ::4A52om o:770 'sw' 2ti5fi:;.::-2Z.53 .:: o o.- 0. o:. o :. I o o li 13A-4ocs 0.143 ow 4.00 2.55 0 0 I 0 0 0 i 0 0 0 1A�1om 1.270 nw 35.56 45.24 0 0 0 0 0- ! 0 0 1 0 ,4A5-2omd 0,770 nw 21,56-. 36.90 0. 0 0 0- 0 0 0 0 P 12C-0sw' 0 091 =' 2.55.k .:1.28 0 .. 0 .j 0 .0 0 0: p 0. C 16A30md 0032 - 0.90 2.32 50 50 116 25 25 22 58 F ''2 tpL" = ,: O'.989 27.69.:..,:oz6 5o:.. :-5 1 0 : 25` { :0 � I i i ..:. 6 c)AED excursion I I I -8 -2 Envelope loss/gain I I I 3¢3 210 j 22 56 12 a)' Infiltration I I �0 25 j 0 0 b) Room ventilation ! 0 0 j 0 0 13 Internal gains: Occupants @ 230 0 1 0 0 I 0 Appliances/other 0 0 Subtotal Qines 6 to 13) I ! 4,3 235 22 56 Less extemal load i 0 0 0 0 Less transfer j 0 0 0 0 Redistribution 6 14 j -22 -56 14 Subtotal 9 249 I 0 0 15 Duct loads 34% 53% 1 7 132 34% j 53% 0 0 Total room load Air required(cfm) 8 16 0 0 Calculations approved bvACCA to meet all requirelments of Manual J 8th Ed. A& - - wrightso ( 2017-Apr-1017:19:28 7 Right-Suite@ Un versa]2017 17.0.14 RSU08101 Page 5 :k Calcs\Documents\W NNE-THE WINDSOR- EVISED.rup Calc=MJ8 Front Door faces: i I I i -wr ghtsoft° Right-JIouse Worksheet J ' Entire H _ QUICK CA' LI CS, INC. By 317 ST LUCIE LN.,FT.PIERCE, L 34946 Phone:772 16I 799 Fa)c 772-466-6796 Email:QUICKCALCS@AO .COM 1 Room name I FOYER ! BEDROOM 3 3 Room t 14.0 ft height 8.0 ft 9.O ft eat/cool 8.0 ft heat/cool 4. Room dimensions 1.0 x: 92.0 ft 13.0 x 13.0 ft 5 Room area 92.0 ft2 I 169.0 ft2{ Ty Construction U-value Or HTM Area (ft-) Load Area (ft�j Load number (Btuh/ftk*F) (Btuh/ft2) 1 or perimeter (ft) �.Btuh) or perimeter (ft) (Btuh) ' i j Heat Cool Gross N/P/S Heatl I Cool Gross N/P/S Heat Cool 6 13A4ocs 0143 he 4 00 2.55 0 0 1 0 0 104 88 351 223 1Ac1om 1 270 ne 3556 7043 0 0 ' 0 0- 0 0 :0 0 1Ac1om :1 270 ne, 3556 7093 _ 0 0 0 0 0 - 0 Q pAc1om ` $270 .ne. 35: 6 4524 0 0 { 0 0 16 ,0 581 i >:739 11 13A4ocs 0.143 se 4.0D 2.55 64 41 155 105 0 0 0 0 �—D _11D0 0.390 _se 10.92 11.31 23 23 ! 248 257 0 0 0 0 y/ 13A-400s 0143 s 4.'00 2;55 - 8 13 2 20 8:- 8 32 20 L--G 4A5 tom -0.770 .sw;. . 21.56-. 27:53 0 0. 0 0 .. 0 :0 p.. . 0 V�1 13A4ocs 0.143 nw 4.00 2.55 0 0 ! 0 0 0 i 0 0 0 {—G 1A-c1om 1.270 nw 35.56 45.24 0 0 ! 0 0 0 0 0 0 �G 4A5-2omd 0 770 nw 21.56, 36.90 0 0 0 0 0 0 0 0 P ';12C-0sw: : ' - 0.091 255 : d 28:, 88 88 i 4 113' 100 :104 :265 133 C 16A-30md 0.032 - 0.90 2.32 92 92 2 213 169 169 151 392 F '4MpI,'. 0 989 - 27.69 0.00 92 9 j: 249 0 .169`. {. 14'' '368 0 i 6 c)AEO excursion I I I I -25 j -52 Envelope loss/gain I I I 10¢2 684 1768 1456 12 a) Infiltration 162 46 252 71 b) 'Room ventilation ! 101 0 0 0 13 Internal gains: Occupants @ MO 0 0 0 j 0 Appliances/cthe ! 0 0 Subtotal(lines 6 to 13) I I 11(3 730 2020 . 1527 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal i 11 730 1 2020 1527 15 Duct loads 340/6 53% 390 386 34% 53% 677 808 Total room load 1 Air required(cfm) 57713 11 26 3488 27 2100 Calculations a roved b :ACCA to meet all requi4ments of Manual J 8th Ed. A& - k.weightso i ' 2017-Apr-10 17:19:28 k Right-Suite®UniveSsal 2017 17.0.14 RSU08101' i Page 6 ...k CalcslDocumentsXW NNE-THE WINDSOR-REVISED.rup Calc=MJ8 Front Door faces: N 1 ! i i - + wrightsoft° Duct System Summary. pat: Entire Ho d sO By' QUICK CA CS,INC. 317 ST.LUCIE LN.,FT.PIERCE,F 34946 Phone:772-4 Fax 772A66-6796 Email:.QUICKCALCS@AOIr.COM Project Information Fo . WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL i Heating Cooling External static pressure 0.50 in H2O ; 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available.statio pressure 0'.50 in H2O 0.50 in H2O Supply/:return available r ressure 0.250/0.250. in H2O 0.250/0.250 in H2O Lowest friction rate 0.273 in/100ft 0.273 in/100ft Actual air flow 1160 cfm 1160 cfm Total effective length_(TEL) 18 ft I Supply Dlesign Htg Clg Design Diam. H x W Duct ActualI Ftg.Egv Name (ltuh) (cfm (cfm) FIR (in) (i ) Mat] Ln(ft) i Ln(ft) Trunk I , BATH h 586 28� 16 0.372 4.0 OxO VIFx 19.5 1 115.0 st1 BEDROOM 2 c 2730 161 117 0.384 7.0 Ox 0 VIFx 15.0 1 115.0 st1 BEDROOM 3 h . 2697 127I .100 0.353 6.0 Ox 0 VIFx 26.8 1 115.0 . st1 DINING/GREAT ROOM C 3411 129 147 0.292 7.0 Ox 0 VIFx' 36.5 �. 135.0 st2. DINING/GREAT ROOM=B C 3411 129 147 0.371 7.0 OxO VIFx 19.9 I 115.0 st1 DINING/GREAT ROOM-C C 3411 129 147 0.278 7.0 OxO VIFx 44.9 135.0 st2 FOYER h 1553 73 48 0.490 4.0 Ox0 VIFx 7.0 j 95.0 KITCHEN c 2875 88 124 0.366 6.0 Ox 0 VIFx 21.8 115.0 st1 LAUDRY. c 145 12 6 0.371 4.0 Ox0 VIFx 19.9 115.0 stl1 M.BATH h 1091 51 50 0.282 6.0 OxO VI Fx 42.3 135.0 st2 MASTER BEDROOM h 3190 100 124 0.273 6.0 OxO VIFx 48.4 135.0 st2 MASTER BEDROOM-A h 3190 150 124 0.284 6.0 OxO VIFx 40.9. 135.0 st2 Wlc C 216 4 9 0.202 4.0 Ox0 VIFx 36.0 135.0 st2 SupplyDetail Table Trunk Htg 6Ig Design Veloc Diam H x W Duct Name Type (cfm) I(cm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 612 602 0:273 780 1. 12.0 0 x 0 V]nlFlx st1 st1 Peak AVF 1087 I 1112 0.273- 796 ' 16.d 0 x 0 VinlFlx 4 i 1 I - I I I i {r{} htsoft° I i 2017-Apr-10 17:19:29 wri r 9 I Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1 ...k Calm%Documents\W NNE-THE WINDSOR REVISED".rup Calc=MJB Front Door faces: N I I 1 i - I I , I I Return Branch Detail Table I I I I Grille tg Clg TEL Design Veloc .:Diam H x W Stud/Joist Duct Name Size(in) (c m) (cfm) (ft) FR ' (fpm) (in) (in) Opening(in) Matl Trunk, i rb1 Ox 0 1160 1160. I 0 0 0 0 Ox 0 VIFx I i i � f � i i I i j i i i i I i j j I i i htso 2017-Apr-10 97:19:29 wri r 9 � Right-Suite®Ur wral 2017 17.0.14 RSU08101 I I Page 2 k CalcsMocuments\W ME-THE WINDSOR-REVISED.rup Calc=MJ8 Front Door faces: N I j