Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Revision, energy calcs, 4.7.7
FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE,FL, Permit Number: Ow net: \\ql-\ 4v , . Jurisdiction: Deign Location: FL, Fort Pierce County:: ST.LUCIE COUNTY(Florida Climate Zone 2') i P4. ew construction or existing New(From Plans) 9. Wall Types(1432.0 sqft.) Insulation Area ingle family or multiple family Single-family a.Concrete Block-Ext Insul, Exterior R=4.1 1224.00 ft2b.Frame-Wood,Adjacent R=11.0 208.00 ft2 umber of units,if multiple family 1 c.N/A R= ft2 umber of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1753.0 sqft.) Insulation Area 0 ft2 6. Conditioned floor area above grade(ft a.Under Attic(Vented) R=30.0 1753.0 (ft2) a. b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 ' 11.Ducts R ft2 7. Windows(151.4 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 325 a. U-Factor: Sgl,U=0.54 111.36 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a.Central Unit 34.8 SEER:1�5.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.850 ft. Area Weighted Average SHGC: 0.250 14.Hot water systems 8. Floor Types (1753.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.970 a.Slab-On-Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.086 Total Proposed Modified Loads: 53.74 PASS Total Baseline Loads: 53.87 I hereby certify that the plans and specifications covered by Review of the plans and O4Z$E Sr�1� this calculation are in compliance with the Florida Energy specifications covered by this Code. ~__ calculation indicates compliance � ��,, '� ..�` vs+ with the Florida Energy Code. ;�,;. „ O PREPARED BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. 5� with the Florida Energy Code. G'OD wt, OWNER/ �N BUILDING OFFICIAL: DATE: DATE: DATE: i - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checkli e R n v pe leakage test report in accordance with R402.4.1.2. i 4/3/2017 2:28 PM EnergyGauge®USA-FlaRes2014 Section pli S a Page 1 of 5 i I FORM R405-2014 PROJECT Title: WYNNE THE WINDSOR Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot# Owner: Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 225 Street: THE WINDSOR Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: ST.LUCIE COUNTY Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE FaTily Type: Single-family FL, NeW/Existing: New(From Plans) ment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisturel Range FL, Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 i SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M.BATH 61 488 No 0 1 Yes Yes Yes i 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes I 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yesi Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ft2 ____ 0 1, 0 2Slab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft2 0 1! 0 3 Slab-On-Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft2 ____ 0 1 0 4 Slab-On-Grade Edge Insulatio M.BATH 7 ft 0 61 ft2 0 1 0 5 Slab-On-Grade Edge Insulatio LAUDRY 1 ft 0 36 ft2 ____ 0 1 0 I 4/3/2017 2:28 PM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab-On-Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft2 ---- 0 1 0 7SIab-On-Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft2 ---- 0 1 0 8SIab-On-Grade Edge Insulatio KITCHEN 11 ft 0 209 ft2 ---- 0 1 0 9 Slab-On-Grade Edge Insulatio BATH 5 ft 0 50 ft2 ---- 0 1 1 0 10SIab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft2 ---- 0 1 0 11SIab-On-Grade Edge Insulatio FOYER 9 ft 0 92 ft2 ---- 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 ft2 ---- 0 1 1 0 ROOF I / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested In,'sul. (deg) 1 Gable or Shed Metal 1847 ft2 292 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC V # Type yp Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft2 N N I CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) MASTER BEDRO 30 Blown 224 ft2 0.1 Wood 2 Under Attic(Vented) WIC 30 Blown 63 ft2 0.1 Wood j 3 Under Attic(Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic(Vented) M.BATH 30 Blown 61 ft2 0.1 Wood 5 Under Attic(Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood 6 Under Attic(Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood 7 Under Attic(Vented) DINING/GREAT 30 Blown 588 ft2 0.1 Wood 8 Under Attic(Vented) KITCHEN 30 Blown 209 ft2 0.1 Wood 9 Under Attic(Vented) BATH 30 Blown 50 ft2 0.1 Wood 10 Under Attic(Vented) HALL 30 Blown 25 ft2 0.1 Wood 11 Under Attic(Vented) FOYER 30 Blown 92 ft2 0.1 Wood 12 Under Attic(Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood WALLS I Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w �t TO Mail TAxpe1 'NE=>W Exterior Concrete Block-Ext InsMASTER BE 4.1 16 0 8 0 128.0 ft2 0 0 d 5 0 2 SW=>E Exterior Concrete Block-Ext IndUASTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0j.5 0 3 rNW=>S Exterior Concrete Block-Ext InIMASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 4 NE=>W Exterior Concrete Block-Ext InEMASTER BA 4.1 8 0 8 0 64.0 ft2 0 0 65 0 4/3/2017 2:28 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 I � I FORM R405-2014 WALLS i Adjacent Space Cavity Width Height Sheathing Framing Solar Below 5 NE=>W Exterior Concrete Block-Ext InsuM.BATH 4.1 7 0 8 0 56.0 ft2 0 0 0.5 0 6 NE=>W Exterior Concrete Block-Ext InfiffDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.5 0 7 SW=>E Exterior Concrete Block-Ext InEUMNING/GRE 4.1 30 0 8 0 240.0 ft2 0 0 0.5 0 8 NW=>S Exterior Concrete Block-Ext IndNNING/GRE 4.1 20 0 8 0 160.0 ft2 0 0 0.5 0 9 SW=>E Exterior Concrete Block-Ext InsuKITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.5 0 10 NE=>W Exterior Concrete Block-Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 11 SE=>N Exterior Concrete Block-Ext Insul FOYER 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 12 SW=>E Exterior Concrete Block-Ext Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0 13 NE=>W Exterior Concrete Block-Ext InfiffDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0 14 SW=>E Exterior Concrete Block-Ext InQEDROOM 3 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0 15 N=>SW Garage Frame-Wood BEDROOM 3 11 26 8 208.0 ft2 0.23 0.5 0 DOORS I # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>N Insulated FOYER None .39 3 3 6 8 21.7 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 NW=>S 3 Metal Low-E Single Yes 0.54 0.25 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 NE=>W 5 Metal Low-E Single Yes 0.54 0.25 6.9 ft2 1 ft 0 in 1 ft 4 in None None 3 NE=>W 6 Metal Low-E Single Yes 0.54 0.25 16.2 ft2 1 ft 0 in 1 ft 4 in None None 4 SW=>E 7 Metal Low-E Single Yes 0.54 0.25 39.8 ft2 1 ft 0 in 1 ft 4 in None None 5 NW=>S 8 Metal Low-E Single Yes 0.55 0.25 40.0 ft2 8 ft 0 in 1 ft 4 in None None 6 NE=>W 13 Metal Low-E Single Yes 0.54 0.25 16.2 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds, Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 806 ft2 806 ft2 26 ft 8 ft 11 INFILTRATION # ^ Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1636.1 89.82 168.92 .2598 7 L 4/3/2017 2:28 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block j Ducts 1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 •Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 i sys#1 HOT WATER SYSTEM I # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None i SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS ----Supply-- ---Return-- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 325 ft2 Attic 95 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar Apr May rj Jun rj Jul rj Au Se Oct Nov' Dec Heatin HJan HFeb Mar Apr May Jun Jul AujXj Sep Oct Nov X DecVentin Jan Feb X Mar [Xl A r [ Ma Jun Jul Aug Se [X]Oct H Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 801 80 PM 80 80 78 78 78 78 78 78 78 78 781 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78' 78 PM 78 78 78 78 78 78 78 78 78 78 781 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 681 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68, 68 PM 68 68 68 68 68 68 68 68 68 68 661 66 i I 4/3/2017 2:28 PM Ener Gau e gy g O USA-FlaRes2014 Section R405.4.1 Compliant Software ,Page 5 of 5 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA roject Name: WYNNE THE WINDSOR Builder Name: WYNNE DEVELOPMENT treet: THE WINDSOR Permit Office: ST.LUCIE COUNTY ity,State,Zip: FT.PIERCE; FL, Permit Number: wner: Jurisdiction: Design Location: FL,Fort Pierce OMPONENT CRITERIA CHECK it barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/doorjambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. I Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. yRecessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 4/3/2017 2:28 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 `FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. i THE WINDSOR, FT. PIERCE, FL, 1.lingle construction or existing New(From Plans) 9. Wall Types Insulation Area 2. family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1224.00 ftz b.Frame-Wood,Adjacent R=11.0 208.00 ft 3. Number of units,if multiple family 1 c.N/A R= ftZ 4. Number of Bedrooms 3 d.N/A R= ftz 10.Ceiling Types Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1753.00 ftZ 6. Conditioned floor area(ftz) 1753 b.N/A R= ftZ z 7. Windows- Description Area c.N R= ft a. U-Factor: Sgl,U=0.54 111.36 ftz 11. Ducts R ftz a.Sup:Attic,Ret:Attic,AH:Attic 6 325 SHGC: SHGC=0.25 b. U-Factor: SgI, U=0.55 40.00 ftz SHGC: SHGC=0.25 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ftz a.Central Unit 34.8 SEER:15.00 SHGC: I d. U-Factor: N/A ftz 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average Overhang Depth. 2.850 ft. Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14.Hot water systems i z a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1753.00 ft EF:I0.97 b.N/A R= ftz c.N/A R= ftz b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which w' ���IHE Sr,1 g gy g III be installed (or exceeded) _ .y .� i In this home before final inspection. Otherwise anew EPL Display Card will be completed k3" ,p'r�• '�_' based on installed Code compliant features. Builder Signature: Date: a Address of New Home: Ci /FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) .638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. •**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/3/2017 2:28 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 i Pro ect Summa Job: - + wrightsoft Entire House Date: QUICK CALCS, INC. File ®p � 317 ST.LUCIE LN.,FT.PIERCE,FL.34946 Phone:772-466-6799 Fax 772-46M796 Email:.QUICKCALCS AOL.COM: Project • • For: WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL k. Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db. 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 %. Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment.Load Sizing Structure 18467 Btuh Structure 17655 Btuh Ducts 6190 Btuh Ducts 9340 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humnone idification 0 Btuh Blower e) 0 Btuh Piping 0 Btuh Equipment load 24657 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 25645 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2453 Btuh Ducts 2554 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) . Area(ft2) 175g 1753 Equipment latent load 5007 Btuh Volume(ft3) 14741 14741 Air changes/hour 0.38 0.20 Equipment total load 30652 Btuh Equiv.AVF(cfm) 93 49 Req. total capacity at 0.70 SHR 3.1 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIERAIR CONDITIONING Model 25HBC536A*030 Cond 25HBC536A*030 AHRI ref 7914585 Coil. FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 Btuh @ 47°F Latent cooling 10440 Btuh Temperature rise 27 OF Total cooling 34800_ Btuh Actual-airflow 1160. cfm Actual airflow 1160. cfm _ . Air flow factor 0.047 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat. Load sensible heat ratio 0.84 Capacity balance point=34 OF Backup: Input=7 kW, Output='23009 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of-Manual J 8th Ed. wrightsoft` Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Apr-10 17:19:28 ACM Page 1 ...k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc=MJ8 Front Door faces: N - wrightsoft Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS AOL.COM 1 Room name Entire House MASTER BEDROOM 2 EVosed wall 153.0 ft . 45.0 ft 3 Room height 8.4 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 280.0 ft 5 Room area 1753:0 ft- 280.0 ftz Ty Construction U-value Or HTM Area number (Btuh/ft'°F) (Btu 2) or perimeter (ft) (Btuh) oorperimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 13A�ocs'.- -0143 .ne. -4:00 255 488 448 1795 ' 1141 192 192, 769 489 1Ac11. om : T270 ne`: 35:56 70.43 -.7 0 247 488 0' 0: ;p 0 _1A-c1om 1 270 ne- 35 56 70.43 16 0 581 - 1151 : 0>' 0:-*: '0 "Q 1A-c1om .1:270, ne. 35.58 45:24 16 0 581 ..Z39 - .: -0, .0. . 0_ 0; I 11 13A4ocs 0.143 se 4.00 2.55 64 41 165 105 0 0 0 0 11DO 0.390._se 10.92 11.31 23 23 248 257 0 0 0 0 134 400s.. '" 0.143 sw. :4.00 2.55 437 396 1584 : `1007 56 56.. 224 '143 .4A5 tom O:TIO sw 21.56 . 27:53 41 45 893 1140 .: 0 - 0:. 0...: 0 13A-4ocs 0.143 nw 4.00 2.55 290 217 867 551 112 79 318 202 I-G 1Ac1om 1.270 nw 35.56 45.24 33 0 1162 1478 33 0 1162 1478 4A5.2omd, 0.770 .nw_ 21.56 36.90 41. 0 880, 1505 0 0 0 0 P•:_ 12C-0sw. 0.091 .-2:55 .1.28': 308<- -:308 '7M 395 :: 0 :. 0, p ; '0 C . 16A-30md 0.032 - 0.90 2.32 1753 1753 1571 4067 280 280 251 MOF 22A tpl .. 0.989 27.69 0.00 1753 153 '4237. : 0: 286 -45 :. 1246 -..0 6 c)AED exursion 1360 Epp Envelope loss/gain 15594 15385 3970 3561 12 a) Infiltration 2873 810 809 228 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 1000 p Subtotal(lines 6 to 13) 18467 17655 4779 1:3789 Less eMemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18467 17655 4779 3789 15 Duct loads 34% 53% 6190 9340 34% 53% 1602 2005 Total room load 24657 26995 6380 5794 Air required(cfm) 1160 1160 1 1. 300 249 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. w 'igFTttsoft' Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Apr 17P.age 8 ...k Calcs\D.cuments\WYNNE-THE WINDSOR-REVISED.rup Calc=MJ8 Front Door faces: N g 1 -�-wrightsoft° Righti-J®Worksheet Job: Entire House Date: QUICK CALCS, INC. By 1 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772.46"799 Fax 772-466-6796 Email:QUICKCALCS AOL.COM 1 Room name WIC M.BATH 2 FRVosed wall 0 ft 7.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heauuml' 4 Room dimensions 7.0 x 9.0 ft 1.0 x 61.0 ft 5 Room area 63.0 ftz 61.0 ft2 T Construction U-value Or HTM Area z Lo Y number (Btuhfftz°F) (Btu 2) or perimeter (ft) (Btuh) oorperimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross- WKS Heat Cool 6 - - ':.13A=4cos 0.143 :ne 4.00 . 255_ 0 0 0. 0 56 49 196 ' 125 1Ac1om 1.270 ne: 35.56 7043 0 0 0 0 . 7- 0: 247 488 1A c1om 1:270 :ne. 35;56 70:43 0 0 0 A .. 0 1Ac1om 1`.276 =ne 35.56 45:24 0 .0 6: - .0 0' 0; 0 ':0 11 13A-4ocs 0.143 se 4.00 255 0 0 0 0 0 0 0 0 .—D 110 0 0.390 se 10 92, 11.31 0 0 0 0 0 0 0 1 0 13A flocs.- 0:143 sw 4 00 2.55 -.0 .0.-- 0 0 :: 0 0 0 0 ;4A52om :0;770 sw. 21:56 27 53 0 _ 0 0 0 0 0 0 V�J 13A-0ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 j 0 I�—_—_GG 1A�1om 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5-2(?md 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0, P ';12C-0sw- 0.091 '2.56.- -.1:28 i0 ,p ,0 0 ._ -.0 0•.< 0 0 C 16A-30md 0.032 - 0.90 2.32 63 63 56 146 61 61 55 142 ;22AIpl: 0:989>':-.. 27;69 ' 0;00 63 :0 4. 0 :61 7 194 0. i : 6 c)AED e)xursion -5 -26 i Envelope loss/gain 56 141 692 729 12 a) Infiltration 0 0 126 35 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 56 141 817 764 Less a demal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 141 817 764 15 Duct loads 34% 53% 19 75 34% 53% 274 404 Total room load 75 216 1091 1168 Air required(cfm) 4 9 51 50 Calculations approved byACCA to meet all requirements of Manual J.8th Ed. . 41- wrigiltsoft' 2017-Apr-1014:19:28 �LcA Right-Suite®Universal 2017 17.0.14 RSU08101 Page 2 ..k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc=MA Front Door faces: N i -t +wrightsoft* Right-JO Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946•Phone:772-466-6799 Fax 772-466-6796 Email.QUICKCALCS AOL.COM 1 Room name LAUDRY BEDROOM 2 2 • Exposed wall 0 ft 12.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 6.0 x 6.0 ft 15.0 x 12.0 ft 5 Room area 36.0 ft2 180.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load i number (Btuh/ft2-0F) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 , 13A-0ocs- 0.143.-:ne.; 4:00" _ 2.55 0 0 0 0 96 80 319 203, 1A�1otn t;270 rie• 3556 70:43 0 0 0 0:- 0 0 . 0 =0; 1A c1om 1 270 ne: 35 56: 70.93 A 0 0 0 16 0 : 581- F 1151 1Ac1om 1;270 ne 35 56 45:24 0 0 _ 0 0 0 0 11 13AAocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 11DO 0.390 se 10.92 11.31 0, 0 0 0 0 0 0 0 13A-0acs : 0,143 sw;-. 4;00 255 0 0 0 0 0 0 : :0 p 4A5 tom ' 0:770..sw"• . .21.56 .2T53 .0 0 0 0 --. 0" 0 - 0" 0 1.n'rI 13A4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 ! 0 �-G IA-c1om 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 -V 4A5-2omd" 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 P� ti12GOsw .'0:091 Z55 - s~1.28 0 0 0 0:.-.. 0-.;: 0.. A' •0. C 16A-30md 0:032 - 0.90 2.32 36 36 32 84 180 180 161 418 F 22Prtpl 0:989 :._: 27:69 _ 0.00 '. 36 0 p 0. 180. 12 -332 0 i r I a 1. 6 c)AED excursion -3 -60 Envelope loss/gain 32 81 1394 1711 12 a) Infiltration 0 0 216 61 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal pines 6 to 13) 32 81 1609 1772 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 6 14 14 Subtotal' 38 95 1615 1786 15 Duct loads 34% 53% 13 50 34% 53% 541 945 t Total room load 51 145 2156 2730 Air required(cfm) 2 6 101 117 Calculations approved bV ACCA to meet all requirements of Manual J 8th Ed. 1 444- wrightsoft' 2017-Apr-1017:19:28 AFM Right-Suite®Universal 2017 17.0.14 RSU08101 Page 3 k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Cale=MJ8 Front Door faces: N i r I - -wrightsoft° Right-M Worksheet Job: Entire House Date` By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name DINING/GREAT ROOM KITCHEN 2 E:Q�osed wall 50.0 ft 11.0 ft 3 Roam height 8.9 ft heat/cool 8.9 ft heat/cool 4 Room dimensions 1.0 x 588.0 ft 19.0 x 11.0 ft 5 Room area 588.0 ft2 209.0 ft2 Ty .Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft;°F) (Btu 2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W, 13A-4ocs 0.143 =ne 4.00 265, 0 0 0. 0 0 0 0 0 1Aq1om 1i270 :ne 35.56 70.43 0 A 0 0 0 0 0 ;0 1A�1om'- 1.270 ne 35.56 70:43 0 0 0 0". 0 0 ` 1A c1om 1.270- ne=: . 35:56 45:24 0 0_ 0 -_ 0 0: 0 0 =0 11 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 �--D 11D0 0:390 se 10.92. 11.31 0 0 0 0 0 0 0 0 13A-0ocs': O143 swC 400' 255 267 :.226 903` :.. 574 =. 98 98_ 392 249 4A5-2om '. 0:770 sw" 21.56 27.53 All . 22. 893 _ 1140 13A4ocs ' 0.143 nw 4.00 2.55 178 137 549 349 0 0. 0 1 0 IA-clom 1.270 nw 35.56 45.24 0 0. 0 0 0 0 0 I 0 4A5-2omd 0.770 nw 21.66. 36.90 41 . 0 880 1505 0. . 0 0 0 14-VG4gif•. .. -' . `0.091 - 2:55 1:28 '0 0`-: 0 0 -':. 116.. -:116 295 '.148 C 16A 30md 0.032 0.90 2.32 588 588 527 1364 .209 209 187 485 F, 22M 1 '03989 '-:27:60 0.00. 588 50 . . .:1385.: 0 209 11 305 0 i - L- i 6 c)AED ecursion 1004 -64 Envelope loss/gain 5136 5937 11791 818 12 a) Infiltration 1000 212 220 62 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 b 0 Appliances/other 0 1000 Subtotal(lines 6 to 13) 6136 6679 1399 . 11880 Less e#emal load 0 0 0 0 Less transfer 0 0 0. 0 Redistribution 6 14 0 0 14 Subtotal 6142 6693 1399 1880 15 Duct loads 1349/6 53% 2058 3541 34% 53% 469 995 Total room load 8200 10234 1861 2875 Air required(cfm)' 3861 440 88 124 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft- 2017-Apr-1017:19:28 C�P: Right-Suite®Universal 2017 17.0.14 RSU08101 Page 4 k Calcs\Documents\WYNNE-THE WINOSOR-REVISED.rup Calc=MJ8 Front Door faces: N -wr ghtsoft° Right-M Worksheet °b Entire House Date: QUICK CALCS, INC. By: 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS AOL.COM 1 Room name BATH HALL 2 Biposed wall 5.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 10.0 x 5.0 ft 5.0 x 5.0 ft 5 Room area 50.0.ft2 25.0 ft2 Ty .Construction U-value Or HTM Area 2 Load Area (ft2) Load number (Btuh/ft'-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A4ocs 0.143 ne 4 00 2.55 40 40 160 102 0 0 01 0 1A c1om 1:270 ne 35 56 7043 0 0 0 0 0 0; 0 -`.0 C. 0' 1A�1om .. 1 270 ne; . - 35.56. .45.4 0 0 0 0. 0 0, 0 0 c 11 W 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 L—p 1100 0,390 se 10.92, 11.31 0 0 0 0 0 0 0 0. 13A-0ocs '- 07143 ;sw:, 400 2l55 0 0 0 0 p p 0 p 0.770 -sw 21.56 27:53 0 .: 0 0: 0 0 ':.. 0 0 0 13A4ocs 0:143 nw 4.00 2.55 0 0 0 0 0 0 0 0 IA-c1om 1.270 nw 35.56. 45.24 0 0 0 0 0 0 0 0 4A5-2omd 0.770 nw 21.56-_ 36.90. 0 0 0 0 0 0 0 0 Pi lk4sw_: .0:09T.. 2:55: .1:26-'.' _ 0 0 .0* p'_ 0 0 0. .:'6 C 16A30md 0.032 - 0.90. 2.32 50 50 45 116 25 25 22 58 F ;22A tpF 0:989 27:68 0:00 r. 50 5 438 : 0. 25; 0: 0 p. r 6 c)AED excursion -8 -2 Envelope loss/gain 343 210 22 I 56 12 a) Infiltration 90 25 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other p I p Subtotal(lines 6 to 13) 433 235 22 - 56 Less e:Qemal load 0 0 0 0 Less.transfer 0 0 0 0 Redistribution 14 Subtotal 439 249 0 0 15 Duct loads 34% 53% 147 . 132 34% 53% 0 0 Total room load Air required(cfm) 5281 16 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. Aft411- wriSjhtsoft- 2017-Apr-1017:19:28 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 5 k CalcsWocumentsMYNNE-THE WINDSOR-REVISED.rup Cale=MJ8 Front Door faces: N wrightsoft• Right4@ Worksheet °b Entire House Date: QUICK CALCS, INC. By. 317 ST LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS a�OL.COM 1 Room name FOYER BEDROOM-3 2 Bposed wall 9.0 ft 14.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heaticool 4 Room dimensions 1.0 x 92.0 ft 13.0 x 13.0 ft 5 Room area 92.0 ft2 169.0 ft2 Ty Construction U-value Or HTM Area (ft2) . Load Area (ft2) Load number (Btuh/ft;°F) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A4ocs 0.143 -ne 4.00 2.65 0 0 0 0 104 88 351 223 1A c1om 1.270 ne 35.56 70.43 0 " 0 0 0 0 '0. :0 0 1A-c16m .' 1'270 .ne. 35.56' 70:43I .. 0," 0 0 p 0 . 0; 0 0' 1A�1om :. 1.270 .ne. . 35.56' 4524 0. 0" 0 0 16 0 581. s739 c 11 W 13A4ocs 0.143 se 4.00 2.55 64 41 165 105 0 0 0 0 L-D 11D0 0.390 se_ 10.92 11.31 23 23 248 257 0 0 0 0 13A11ocs 0143 sw. -4 00 2.56 8 8 32 _ .. 20 8:1 8.: 32 ,20: 4A5-2om 0.770 sh. 21.56 27.53 .0 0 0. 0 0 0 0 `:-0 13A4ocs 0:143 .my 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1.270 nw 35.66 45.24 0 0 0 0 0 0 0 0 4A5.2omd 0.770,nw 21.56 36.90 0 0 0 0 0 0 0 0. P 12C-0sw::.' 0 091 ;::-. 2:55 1:.28 88 88 224 113 104 '.104 .265 4M C 16A-30md 0.032 0.90 2.32 92 92 82 213 169 169 151 392 F. "22Aapl 0 989 "-: 27:69:: abb 92 -9 249 0 169 14 388 0 6 c)AED exursion -25 -52 Envelope loss/gain 1002 6&1 1768 1456 12 a) Infiltration . 162 46 252 71 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 p Subtotal Qines 6 to 13) 1163 730 2020 . '1527 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1163 780 2020 1527 15 Duct loads 34% 53% 390 386 341/6 53% 6771 808 Total room load 1553 1116 2697 2335 Air required(cfm) 73 48 127 100 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. .� - wrightsofY 2017-Apr-1017:19:28 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 6 k CalcsWocuments\WYNNE-THE WINDSOR-REVISED.rup Calc=MJ8 Front Door faces: N i Duct-S stem Summary Job: wrightsoft- y Date: Entire House ft: QUICK CALCS,INC. I 317 ST.LUCIE LN.,FT PIERCE,FL 34946 Phone:772-46"799 Fax 772-466-6796 Email:,QUICKCALCS AQL.COM Project I • • For. WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL j Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses. 0 in H2O 0 in H2O Available.static pressure 0:50 in H2O 0.50 in H2O Supplly/:return available pressure 0.250/0.250. in H2O 0.250/0.250 in H2O Lowest friction rate 0.273 in/100ft 0.273 in/100ft Actual air flow 1160 cfm 1160 cfm Total effective length(TEL) 183 ft SupplyBranch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln (ft) Trunk BATH h 586 28 16 0.372 4.0 Ox 0 VIFx 19.5 115.6 st1 BEDROOM 2 C 2730 101 117 0.384 7:0 OxO VIFx 15.0 115.0 st1 BEDROOM 3 Ih . 2697 127 100 0.353 6.0 OxO VIFx 26.8 115A st1 DINING/GREAT ROOM C 3411 129 147 0.292 7.0 Ox0 VIFx 36.5 135.0 st2 DINING/GREAT ROOM-B C 3411 129 147. 0.371 7.0 0x0 VIFx 19.9 115.0 st1 DINING/GREAT ROOM-C C 3411 129 147 0.278 7.0 Ox 0 VIFx 44.9 135.0 st2 FOYER h 1553 73 48 0.490 4.0 OxO VIFx 7.0 95.0 KITCHEN c 2875 88 124 0.366 6.0 Ox 0 VIFx 21.8 115.0 st1 LAUDRY C 145 2 6 0.371 4.0 OxO VIFx 19.9 115.0 st1 M.BATH h 1091 51 50 0.282 6.0 Ox 0 VIFx 42.3 135.0 st2 MASTER BEDROOM h 3190 150 124 0.273 6.0 OxO VIFx 48.4 135.0 st2 MASTER BEDROOM-A h 3190 150 124 0.284 6.0 Ox 6 VIFx 40.9. 135.0 st2 WIC C 216 4 9 0.292 1 4.0 Ox0 VIFx 36.0 135.0 st2 I I Supply TrunDetail • - Trunk - Htg Clg Design Veloc Diam. H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (In) Material Trunk st2 Peak AVF 612 . 602' 0.273 780 12.0 0 x 0 VinlFlx st1 SO Peak AVF 1087 1112 0.273 796 16.0 0 x 0 VihIFlx t wri htsoftg 2017-Apr-1017:19:29 �. 9 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1 'CK ...k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup. Calc=MJ8 Front Door faces: N i I Return Branch Detail Grille Htg Clg TEL Design Veloc D.iam H x W Stud/Joist Duct. Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl: Trunk rb1 ox0 1160 1160. 0 0 0 0. Ox 0 VIFx I . I I I ,a I I r-10 17:19:29 WrightSOft .Right-Suite®Universal 2017 17.0.14 RSU08101 2017-A p ACCA Page 2 k Calcs\DocumentMWYNNE-THE WINDSOR-REVISED.rug Cale=MA Front Door faces; N I