HomeMy WebLinkAboutEnergy calcs Pie- co
FORM R405-2014 Fly�
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
I
Project Name: THE GRAND CARLTON Builder Name: WYNNE DEVELOPMENT
Street: WYNNE DEVELOPMENT Permit Office: ST.LUCIE COUNTY
City,State,Zip: FT.PIERCE, FL, Permit Number:
Owner: <k �C� �-�� Jurisdiction:
Design Location: FL,West Palm Beach County:: ST.LUCIE COUNTY(Florida Climate Zone 2)
I
1. New construction or existing New(From Plans) 9. Wall Types(1437.3 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1250.00 ft2
b.Frame-Wood, Exterior R=11.0 187.33 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 2 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1446.0 sqft.) Insulation Area a. Under Attic(Vented) R=30.0 1446.00 ft2
6. Conditioned floor area above grade(ft2) 1446 b. N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R 1 ft2
7. Windows(139.2 sqft.) Description Area a.Sup:Attic, Ret:Attic,AH:Attic 6 320
a. U-Factor: Dbl,U=0.54 99.23 ft2
SHGC: SHGC=0.25
b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.25 a.Central Unit 34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.586 ft.
Area Weighted Average SHGC: 0.250 14.Hot water systems
8. Floor Types (1446.0 sqft.) Insulation Area a. Electric Cap:40 gallonsEF:0.970
a.Slab-On-Grade Edge Insulation R=0.0 1446.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits iPstat
Glass/Floor Area: 0.096
Total Proposed Modified Loads: 53.72 PASS
Total Baseline Loads: 54.66
I hereby certify that the plans and specifications covered by Review of the plans and �T%E s7.q?,
this calculation are in compliance with the Florida Energy specifications covered by this ti
Code. calculation indicates compliance � �,,,�'' _};,, V+
with the Florida Energy Code. ti /lp1
�PREPAR BY:: Before construction is completed
DATE: this building will be inspected for __l��l ;d
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance Florida Statutes.
with the Florida Energy Code. CODS
OWNER/ GET BUILDING OFFICIAL:
DATE: DATE:
,I
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
4/3/2017 6:45 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
I'
i
FORM R405-2014
PROJECT
Title: THE GRAND CARLTON Bedrooms: 2 Address Type: Street Address
Building Type: User Conditioned Area: 1446 Lot#
Owner: Total Stories: 1 Block/SubDivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate Angle: 135 Street: WYNNE DEVELOPME
Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: ST.LUCIE COUNTY
Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment:
I
CLIMATE
IECC Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,West Palm Beach FL_WEST_PALM_BEAC 2 44 90 70 75 316 60 Medium
I
BLOCKS
Number Name Area Volume
1 Entire House 1446 12514.8
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 BEDROOM 234 1872 No 2 1 1 Yes Yes j Yes
2 WIC 54 432 No 0 1 No Yes Yes
3 MASTER BATH 63 504 No 0 1 Yes Yesl Yes
4 M.BATH 56 448 No 0 1 Yes Yes Yes
5 KITCHEN 172 1376 Yes 0 1 No Yes I Yes
6 BATH 45 360 No 0 1 Yes Yes; Yes
7 BEDROOM 2 204 1632 No 1 1 1 Yes Yes I Yes
8 LAUNDRY 42 336 No 0 1 Yes Yes; Yes
9 GREAT/DINING 526 5154.8 No 0 1 Yes Yes I Yes
10 FOYER 50 400 No 0 1 Yes Yesi Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio BEDROOM 40 ft 0 234 ft2 ---_ 0 1 0
. 2 Slab-On-Grade Edge Insulatio WIC 1 ft 0 54 ft2 ___- 0 1 0
3 Slab-On-Grade Edge Insulatio MASTER BATH 9 ft 0 63 ft2 _-__ 0 1 0
4 Slab-On-Grade Edge Insulatio M.BATH 8 ft 0 56 ft2 -___ 0 1 0
5 Slab-On-Grade Edge Insulatio KITCHEN 1 ft 0 172 ft2 __-- 0 1 0
6 Slab-On-Grade Edge Insulatio BATH 5 ft 0 45 ft2 ____ 0 11 0
7 Slab-On-Grade Edge Insulatio BEDROOM 2 34.2 ft 0 204 ft2 ___- 0 1, 0
4/3/2017 6:45 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
I
• I
'L I
FORM R405-2014
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
8 Slab-On-Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 ---- 0 1 0
9 Slab-On-Grade Edge Insulatio GREAT/DINING 47 ft 0 526 ft2 ---- 0 1 0
10SIab-On-Grade Edge Insulatio FOYER 7 ft 0 50 ft2 ---- 0 1 0
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
v # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Gable or shed Metal 1524 ft2 240 ft2 Light 0.6 No 0.9 No 10 18.4
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 150 1446 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) BEDROOM 30 Blown 234 ft2 0.1 Wood
2 Under Attic(Vented) WIC 30 Blown 54 ft2 0.1 Wood
3 Under Attic(Vented) MASTER BATH 30 Blown 63 ft2 0.1 Wood
4 Under Attic(Vented) M.BATH 30 Blown 56 ft2 0.1 Wood
5 Under Attic(Vented) KITCHEN 30 Blown 172 ft2 0.1 Wood
6 Under Attic(Vented) BATH 30 Blown 45 ft2 0.1 Wood
7 Under Attic(Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood
8 Under Attic(Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood
9 Under Attic(Vented) GREAT/DINING 30 Blown 526 ft2 0.1 Wood
I
10 Under Attic(Vented) FOYER 30 Blown 50 ft2 0.1 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
1 N=>SE Exterior Concrete Block-Ext InsfHEDROOM 4.1 9 0 8 0 72.0 ft2 0 0 015 0
2 S=>NW Exterior Concrete Block-Ext InsIBEDROOM 4.1 18 0 8 0 144.0 ft2 0 0 O15 0
3 W=>NE Exterior Concrete Block-Ext InsiHEDROOM 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0
4 S=>NW Exterior Concrete Block-Ext InsMRSTER BA 4.1 9 0 8 0 72.0 ft2 0 0 OI5 0
5 S=>NW Exterior Concrete Block-Ext InsuM.BATH 4.1 8 0 8 0 64.0 ft2 0 0 OL5 0
6 N=>SE Exterior Concrete Block-Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 65 0
7 N=>SE Exterior Concrete Block-Ext InQEDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 O.5 0
8 E=>SW Exterior Concrete Block-Ext In!8EDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 O.5 0
9 SE=>W Exterior Concrete Block-Ext InfiffDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0L5 0
10 S=>NW Exterior Concrete Block-Ext InfiffDROOM 2 4.1 4 0 8 0 32.0 ft2 0 0 O15 0
11 S=>NW Exterior Concrete Block-Ext InsLUAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0
12 N=>SE Exterior Concrete Block-Ext Ins REAT/DINT 4.1 26 0 8 0 208.0 ft2 0 0 0.5 0
I
4/3/2017 6:45 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
I
I
FORM R405-2014 !
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
- -
_13 W=>NE Exterior Concrete Block-Ext IneGREAT/DINI 4.1 21 0 8 0 168.0 ft2 0 0 0.15 0
_14 N=>SE Exterior Concrete Block-Ext Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0 5 0
15 E=>SW Exterior Concrete Block-Ext Insul FOYER 4.1 6 0 8 0 48.0 ft2 0 0 0.15 0
16 N=>SE Exterior Frame-Wood GREAT/DINI 11 23 5 8 187.3 ft2 0.23 0.15 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 E=>SW Insulated FOYER None .28 3 6 8 ! 20 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall Overhang
# Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade i Screening
1 W=>NE 3 Metal Low-E Double Yes 0.54 0.25 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5
2 S=>NW 5 Metal Low-E Double Yes 0.54 0.25 6.9 ft2 1 ft 0 in 1 ft 4 in None None
i
3 E=>SW 8 Metal Low-E Double Yes 0.54 0.25 23.2 ft2 1 ft 0 in 1 ft 4 in None None
4 N=>SE 12 Metal Low-E Double Yes 0.54 0.25 36.8 ft2 1 ft 0 in 1 ft 4 in None None
5 W=>NE 13 Metal Low-E Double Yes 0.55 0.25 40.0 ft2 10 ft 0 in 1 ft 4 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 315 ft2 315 ft2 24 ft 8 ft 11
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000385 1460.1 80.16 150.74 .2656 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Blockl Ducts
1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Blockl Ducts
1 Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1
4/3/2017 6:45 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
i
� I
I .
FORM R405-2014
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
—Supply— —Return— Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 320 ft2 Attic 80 ft2 Default Leakage Attic (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans: j
Cooling Jan [ ]Feb Mar [ ]Apr I
]May ]Jun [X]Jul [X]Aug X Sep Oct Nov, Dec
Heating HJan [X]Feb Mar [ ]Apr
]May ]Jun [ ]Jul [ ]Aug4 Sepp Oct Novl Dec
Ventin Jan [ ]Feb X Mar [ i A r ]]May ]Jun [ ]Jul [ )Aug [ Se [Xl Oct X Novl Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78j 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 j 78
PM 78 78 78 78 78 78 78 78 78 78 78, 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68; 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66, 66
,
I
I I
4/3/2017 6:45 AM ! EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
I
, I
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: THE GRAND CARLTON Builder Name: WYNNE DEVELOPMENT
Street: WYNNE DEVELOPMENT Permit Office: ST.LUCIE COUNTY
City,State,Zip: FT.PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL,West Palm Beach
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces. I
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls,or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs. 1
Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
4/3/2017 6:45 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
I
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
WYNNE DEVELOPMENT, FT. PIERCE, FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
a.Concrete Block-Ext Insul,Exterior R=4.1 1250.00 ft2
2. Single family or multiple family Single-family b.Frame-Wood, Exterior R=11.0 187.33 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 2
d.N/A R= ft2
10.Ceiling Types es Insulation Area
5 Is this a worst case?e Yes a. Under Attic(Vented) R=30.0 1446.00 ft2
(V )
6. Conditioned floor area(ft2) 1446 b.N/A R= ft2
7. Windows" Description Area c.N/A R= ft2
11.Ducts R I ft2
a. U-Factor: Dbl,U=0.54 99.23 ft2 a.Sup:Attic,Ret:Attic,AH:Attic 6 1320
SHGC: SHGC=0.25
b. U-Factor: Dbl,U=0.55 40.00 ft2
SHGC: SHGC=0.25 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a.Central Unit 34.8 SEER:115.00
SHGC:
d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 34.8 HSPF'.8.50
Area Weighted Average Overhang Depth: 3.586 ft.
Area Weighted Average SHGC: 0.250
8. Floor Types Insulation Area 14.Hot water systems Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1446.00 ft2 a.Electric
EF:0.97
b.N/A R= ft2
c.N/A R= ft2 b. Conservation features
None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building ZHE 8T
Construction through the above energy saving features which will be installed (or exceeded) .yob : ATFo
in this home before final inspection. Otherwise, a new EPL Display Card will be completed ",;''��' _" ,.� V0
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home: G City/FL Zip ,
WE
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
,I
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/3/2017 6:45 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
I
I
I
i
I
PrOJeCt $1.1177mai1y na e:
- - wrightsoft Entire House By.
QUICK CALLS,INC.
317 ST.'LUCIE LN.,FT.PIERCE, L 34946 Pho6e:.772)66;6799 Fax 772-466-679.6. Email:QUICKCALCS@AO .COM. j
Project
• - Information
For: THE GRAND CARLTON
WYNNE DEVELOPMENT, FT._PIERCE, FL
Notes:
tes:
Design Information
1
Weather' Fort Pierce, FL, US . .
Winter Design Condi ions Summer Design Conditions
Outside db 42 OF Outsid6;db . 90: OF
Inside db 70 OF Inside db 75 OF
Design TD i 28 OF Design TD 15 OF
Daily range L
Relative;humi ity 50
Moisture diffe ence 61 gr/lb
i
Rez ting Summary Sensible Cooling Equipment:Load Sizing
Structure '7848 Btuh Structure ! 17520 Btuh
Ducts 5654 Btuh' Ducts : ! 8536 Btuh
Central vent,(0.cf ) 0 Btuh Central vent(0 cfm) i 0 Btuh
(none). (none)
Humidification 0' .Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 23503 Btuh. Use manufac urer's data n
Rate/swing m Itiptier 0.95
Infiltration Equipmenf sensible load 24753 Btuh
Method Simplified Latent Coolin E ui merit Load Sizin .
Construction qualit. Average g q p g '
Fireplaces 0 Structure 3203 Btuh
Ducts . : j 2318 Btuh
Central vent(0 cfm) 0 Btuh
Heati . Cool!ngg (none) I
Area(ftz) 14'n9 1446 Equipment latent load 5521 Btuh
Volume(ft') 1:011: 12511
Air changes/hour 0.j45. 0.23 Equipment total load 30274 Btuh
Equiv.AVF(cfm) I i 48 Req. total to lacity at 0.70 SHR 2.9 ton
Heating quipmeht-Slj mmary Cooling Equipment Summary
Make Carrier Make artier
Trade CARFIERAIR CON ITIONING Trade Ell
ARRIERAIR CONDITIONING
Model 251-18 536A*030 j Cond ZSHBC536A*030
AHRI ref 7914585 Coil FX4DN(B,F)037
AHRI ref 7914585
Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER
Heating.input i Sensible cooling ! 24360 Btuh
Heating output 1 600 Btuh @ 47°F Latent cooling 10440 Btuh
Temperature rise 27 OF Total cooling 34800 Btuh
Actual air flow_ 1160: cfm. Actual air flo 1160 cfm
Airflow factor .0.049 cfm/Btuh Airflow factor] j 0.045 cfm/Btuh
Static pressure 0.50 in H2O Static pressure '0.50 in H2O1
Space thermostat Load sensible heat ratio 0.83
Capacity balance point 32 OF
Backup:
Input=7 kW, O put=23009 Bt h, 100 AFUE
i
Calculations approved byACCA to meet all requirements of Manual J 8th Ed. i
.� wrights r 11 0 2017-A 9:29.38
.+ . ,Right-Suite®Uliv versa[2017 17.0.14 RSU08101 p Page 1
ACM ...uick CaIcslDocument THE GRAND CARCTC1N�1446.rup Calc=MJ8 Front Door faces: N
i
i
I
- -wrightsoft. Right-J®Worksheet °b
Entire House Byte'j
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772 66I 799 Fax 772-466-6796 Emalk.OUICKCALCS@AOL.COM {
1 Room name Entire House BEDROOM
2 F)qosed wall 156.2 ft 49.0 ft
3 Room height I 8.7 ft d 8.0 ft heat/cool
4 Room dimensions ,1.0 x 297.0 ft
5 Room area 1445.5 ft2 297.0 ft2'
Ty Construction U-value Or i HTM Area (ft2) Load Area (ft2) Load
number (Btuh/ftz-°F) I (Btuh/ft2) or perimeter (ft) 4Btuh) or perimeter, (ft) (Btuh) .
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-0ogs 0143 ri 4sQ0 2:55 503 4651 1 62 1184 72 j 72 288 183,
81
,4A5 2orrt O TIO _ n . 2156 , 19:31 38 0 , $15 730 0 0 0 0
13A4ocs 0.143 a 4.00 2.55 128 83 �33 212 0 0 0 0
1Ac1om 1.270 e I 35.56 87.29 24 2 848 2082 0 0 0 0
11 ���—Z 11D0 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0
W ' `+_13A4oc. 0.143. s 4.00 255 34 34 �36 86 0 0 0: U
V�! 13A-4ocs 0.143 s 4.00 2.55 360 353 1414 899 216 216 865 550
�--G IA-c1om 1.270 s 1 35.56 34.77 7 7 247 241 0 0 0 0
13A-0ocs 0143 �v 4.00 2.55 310 .237 603 104 72 288 183
1A�1om °; 1270 w. 35'56 5521. 32 2 1 40 : .1 . 32 1 2 1140 1T70
4A5 tom 0 770 w 21.56 .19:31 41 ', 41 0 :0 . 0 J;0
P 12C-0sw. 0.091 - 2.55 1.28 192 192 246__ 0 0 0 0
C , <16A-20md - 0 032- I 0;90 , 2.32 -1446 :1446; 1 95: 3354 297`: 297. 266
F 22Fvtpl 0 989 - 27.69 0.00 1446 156 4325 0 297 49 1357 0,
U. I .-
i
i + I.
t
l
6 c)AED excursion I I � 918 i 627
Envelope loss/gain I I 14961 13349 ! 4204 4003
12 a). Ir>Fltration 28187 791 848 232
b) Room ventilation 10 0 0 j 0
13 Intemal gains: I OccupantsOcl @ eI 230 6 z� 3 .690
Subtotal(lines 6 to 13) + 17848 17520 5053 4925
Less extemal load 0 0 0 0
Less.transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 17848 17520 5053 4925
15 Duct loads 32% 49% 5654 8536 32% 1 49% 1601 2400
Total room load 23503 26056 6653 7325
Air required(cfm). I 1100 1160 328 326
i
L-Calculations a roved b ACCA to meet all r uirements of Manual J 8th Ed.
.wrightsa t-. 2017-Apr-11 09:29:38
A& I Right-Suite®Universal 2017 17.0.14 RSU08101 Pa e 1
...uick Calcs\DocumentsffHE GRAND CARLTON-11446.rup Calc=MJ8 Front Door faces: N g
i
t
wrightsoft Right-JO Worksheet Job.
Date
Endre use . By. ,
QUICK O�►LCS, INC.
317 ST.LUCIE LN.,FT.PIERCE, L 34946 Phone:7721661-6799 Fax 772-46"796 Email:QUICKCALCS ALlL.COM 1
1 Room name WIC KrrCHEN
2 Exposed wall O ft O ft
3 Room height ! 8.0 ft heat/cool 8.0 ft! heat/cool
4 Room dimensions 6.0 x 9.0 ft i 1.0 x 1720 ft
5 Room area I 54.0 ft2 1720 ft?
Ty Construction U-value Or HTM Area z
number Btuh/ft�°F. Btuhlftz or perimeter ft Load Area (ftt � Load
• ( ) � ( ) pe O .. (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Hea� Cool Gross N/P/S Heat Cool
6 13A-0ocs 0143 -)n 4 00 255 0 0 i 0 p p: 0 0
4A5 tom 0.770- n' 2f:56 19 31 0 0 I 0 p p 0. p
13AAocs 0.143 el 4.00 2.55 0 0 0 0 0 0 0 j 0
IA-clom 1.270 e , 35.56 87.29 0 0 .0 0 0 0 0 0
11 11DO 0.390 el 10.92 11.31 0 0 0 0 0 0 0 0
,W.: .13A�4ocs 0143 ser I 4.00 2:55 0 01 0 . 0 0 0 .....0 0
W 13AAocs 0143 s i 4.00 255 0 0 0 0 0 0 0 0
L--G 1Ac1om 1270 sI j 35.56 34.77 0 0 0 0 0 0 0 0
W. 13A�4ods .0143 W 4:00 -2.55 0 ...01 0 0 0 0 6 0
1A-c1om" '. 1 270 w I 35:56 55.21 0 0 0: . 0 0 1 ;0, 0 0
AA-5-2 :. :0 770 ,.-v�: 21;56 19i39 0. 0;. 0 0. 0-_ j :0 0 0
P 12C-0sw - 0.091 _-. 2.55 1.28 0 0 0 0 64 64 163 82
C 16X30md'; :. <0 032 0 90 232 >:54`.. 54; 48? . 125.:, ;172 j'. '172 '154 :.3.99
F 22A tpl 0 989 - I 27.69 0.00 54 0, 0 0 172 0 0 0
j
I
_ I
j
6 c)AED excursion I I I -9 -170
Envelope loss/gain I I �8 117 317 311
12 b) Room ventilation Infiltration
10 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 ; 0
Appliances/oth 0 j 200p
Subtotal(Iines 6 to 13) I �48 117 317 2311
Less external load 0 0 i 0 0
Less transfer ! 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 117 317 2311
15 Duct loads 32% 49% 5 57 32% 49% 100 .1126
TotAirrequiredl room load(c m) 17$ 428 3433
Calculations approved byACCA to meet all requirements of Manual J 8th Ed. i
- -.wrightLssolit-,i � i 2017-Apr-11 j09:29:38
A RightSuite®Universal 2017 17.0.14 RSU08101 1 Page 2
...uick Calcs\Dccument 1THE GRAND CARLTON,1446.rup Cato=MJ8 Front Door faces: N
i
• j I
I
I ,
I
~ - ate`
w6ghtsoftp Right-MR Worksheet b !.
Entire Hause at ;
QUICK CALLS, INC. By
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:77216 I 799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name BATH BEDROOM 2
2 Exposed wall 5.0 ft 34.2 ft j
3 Room height 8.0 ft heat/cool 8.0 ft 1 heat/cool.
4 Room dimensions I 9.0 x' 5.0. ft !1.0 x 203.5 ft
5 Room area 45.0 ftz 203.5 ft?.
Ty Construction U-value. Or HTM Area (ftz) (Load Area (ftz)I Load
number (Btuh/ft2�_°F) (Btuhlftz) or perimeter (ft) :Btuh) or perimeter (ft) (Btuh)
I
Heat Cool Gross N/P/S Hea1 Cool Gross IV/P/S Heat Cool
6 y/ 13A4ocs 0 143 n A.00 255 40 40 60 102. 128 = ` 1213 513 326
G 4A5 tom; 0 T/0 '`n' 21 56 19 31 0 0'i p 0' 0: 1 0 "0 0
13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 80 56 225 143
V��1-G IA-c1om 1.270 a 35.56 87.29 0 0 0 0 24 2 848 2082
11 LID 11DO 0.390 e I 10.92 11.31 0 0 0 0 0 0 0 0
'.13A4ocs .0.143 s 4 00 Z55 .0 0 0 . 0 34 I .34 136 86
Vi/ 13A4ocs 0.143 s 4.00 2.55 0 0 0 0 32 32 128 81
Y-G 1Ac1om 1270 s 35.56 34.77 0 0 0 0 0 0 0 0
13AAocs 0143 4'00 2 55 0 0 0 0 0 0 0 0
1Ac1om•:, 1 270 35'56 55 21 0 -0 0 0 •. 0 ! 0 0 A
4A5 tom 0 770 �nJ 2156 193.1 0 0 ':'' 0 0'. 0` 0 ,U 0
P. 12C-0sw 0.091- - - 2.65_ _.. 1.28_ 0 .0 0 0 .0_ ' 0 0 0
C 16A 30md 0 032 0:90 Z32 :45, 45 40:_ 104' 204:_ j 204 182 472-
F 22A tpI 0.989 - I 27.69 0.00 45 5 38 0` 204 I 34 946 0
7.
I
I
1
6 c)AM excursion I I I I -16 I I 85
Envelope loss/gain I I 3,6 196 2978 3106
I
12 a) Infiltration . I 17 24 I 593 162
b) Room ventilation I 0 0 0 0
13 Internal gains: Occupants @ I 2-30 0 0 1 230
Appliances/other p p
Subtotal Qines 6 to 13) I I 4 5 214 3571 3496
Less external load- 0 0 0 0
Less transfer 0 0 I 0 0
Redistribution 0 0 i 0 10
14 .Subtotal I 4 5 214
15 Duct loads 1 3210 49% 1 104 32% I 49% 1131 1704
Total room load I 0 318 4702 5203
Air required(cfm) I 28 14 I 232 232
i
.Calculations allproved b ACCA to meet all r uirements of.Manual J.8th Ed.
-ft- wrigit�ltsolft� I I I 2017-Apr-11 09:29:38
AC�P. I Right-Sbite®Ugiversal.2017 17.0.14 RSU08101 Page 3
uick Calcs\Document \THE GRAND CARLT N,1446.rup Calc=MA Front Door faces: N 9
I
I ,
i
i
- -vi►rightsot Right-J R orksheet °b
I Date:!
Entire f�ouse
QUICK CII I CS, INC. By.
317 ST.LUCIE LN.,FT.PIERCE,r(L 34946 Phone:7724 661.-6799 Fax 772.46"796 Email:QUICKCALCS@AOL.COM
I
1 Room name ' LAUNDRY i GREAT/DINING
2 =ed wall 6.0 ft 47.0 ft
3 Room height 8.0 ft eat/cool 9.8 ft! heaUcool
4 Room dimensions 7.0 x 6.0 ft 1.0 x 526.0 ft
5 Room area 42.0 ft2 526.0 ft'I j
Ty Construction U-value. Or j HTM Area (ft-) oad Area (ft.) Load j
number (Btuh/ft�°F) (Btuhlft2) or perimeter (ft) �B-Wh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heatl Cool Gross N/P/S Heat Cool
6 13"6cs 0143 •n? 400 255 0 - 01 0 -,. 0 255 217 869 552
_4A5-tom 0 770 .n: 215.6 1931. 0 0; 0 0 38 0 815 730
13A-4ocs 0.143 e I 4.00 2.55 0 0 0 0 0 0 0 . 0
1A-c1om 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0
11 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0
W-.. A-M-3ocs 0143 'se 400 2.55 0 0 0 0 0
V+1 13A-4ocs 0.143 s 4.00 2.55 48 48 92 122 0 0 0 0
� G 1Ao1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
13AAocs 0 143 w 4.00 2.55 0 0 0 0 206 165 661 420
1Ac1om:: 1.270 w: 3556 -'55.21 0 - 0 0• 0>. 0: `0 0 p
4A5 tom 0 770 ":W. 21,56 19:31 0. 0:;. 0. : 0 41" 41 880 -788
P 12C-0sw . 0.091 2.55 1.28 56 56 43_ 72 0_ .I 0 0 0
C 16A30mdt,_ '`0 032 ;0:90 232 42 ;. _ :42 {. .. i38 . 97 -526 "526 421 7220
F 22A-tpl 0.989 - 27.69 0.00 42 6 166 0 526= 47 1302 0
_ j I
I
f
I
6 c)AED excursion I I I I -22 6W
Envelope loss/gain I I 539 276 4997 4379
12 a): Infiltration 104 28 997 273
b) Room ventilation 10 0 0 0
13 Internal gains: Occupants @ I 230 0 0 2 460
Appliances/othe{ I p p
Subtotal(lines 6 to 13) I I 643 298 5994 :5112
Less wdemal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 643 298 I 5994 5112
15 Duct loads 32% 49% 2Q4 145 32% 1 49%1 1899 2490
Total room load 846 443 7892 7602
Air required(cfm) I I 42 20 ' j 390 338
Calculations ar Proved by ACCA to meet all requirements of Manual J.Sth Ed.
-F- wrightsoft- 2017-Apr-11 09:29:38
.4+ A Right-Suite®Ur♦iversal 201717.0.14 RSUD8101 i Page 4
...uick Calcs\Documents THE GRAND CARLTON 1446.rup Calc=MJ8 Front Door faces: N
II
-�-wrightsoft• Right-J'Worksheet °b
Entire Ouse Date:1
QUICK CI i CS, INC. By.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772 66j6799 Fax 772-466-6796 Email:QUICKCALCS AgL.COM
1 Room name I FOYER M.BATH
2 =ed wall j 7.0 ft 8.0 ft
3 Room height 8.0 ft eat/cool 8.0 ft j heat/cool
4 Rodm dimensions 1.0 x 50.0 ft 17.0 x 8.0 ft
5 Room area 50.0 ft2 56.0'ftzl
Ty Construction U-value Or j HTM Area (ft Load Area LO
number (Btuh/ft'--F) (Btuhlft�) or perimeter (ft) Btuh) or perimeter. (ft) (Btuh)
Heat Cool Gross WP/S Heatl Cool Gross N/P/S Heat Cool
6 13A flocs 0143 n:: 4;00 2 55 8 8, 32 .: 20 0 0 w0 0
:4A5 tam>:' 0 770 ,n 21.5. 19.31 ,.0 0 0 0 : 0 i 0.
13A4ocs 0.143 a 4.00 2.55 48 27 08 69 0 0 0 0
11 �� IA-c1om 1.270 e i 35.56 87.29 0 0 0 0 0 0 0 0
6--DDD 11DO 0.390 e 1 10.92 11.31 21 21 229 238 0 0 0 0
;W 13A4ocs 0:143 s 4M . 255- 0 0 0. 0 0 0 0 p
V�/ 13A4ocs 0.143 s 4.00 Z55 0 0 0 0 64 57 228 145
�G IA-c1om 1270 s 35.56 3477 0 0 0 0 7 7 247 241
13A-4ocs 0143 w 4:00 2 55 0 0 0 .0 0 I 0 .0 0.
1Ac1orr 1 270 w 35:56 55 21 -0 0 , 0. 0 - 0
4A5 tom ' 0 770.:w° 29;56 19 3 -0 0_j. 0 '.' 0 0 I 0 0 i _0.
P 12C-0sw 0.091, - 2.55 1.28 72 72 83 92 0 i 0 0 0
C 16A 30md i- 0 032 0 90 232 50 50 45 116 56 ',56 50 13.0
F 22A-tpl 0.989 - 27.69 0.00 50 7 194 0 56 ; 8 222 0
_: . .
M.
1'
� 1
6 c)AED a cursion I I I -39 -38
Envelope loss/gain I I 792 *6 i 747 478
12 a) Infiltration 121 33 138 38
b) Room ventilation 101 0 0 0
i
13 Internal gains: Occupants @ I 230 0 0 0 0
Appliances/other, 0 0
Subtotal Qines 6 to 13) 913 529 885 516
Less odemal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 913 529 885 516
15 Duct loads 32% 49% 2q9 258 32% I 49%u 280 251
Total room.load I 12�2 787 1166 768
Air required(cfm) I j 59 35 I 58 34
Calculations a roved by ACCA to meet all re uirements of Manual J 8th Ed.
Aft` . -�- wrightso • 2017-Apr-11 09:29:38
, Right-Suite@ Universal 2017 17.0.14 RSU08101 Page 5
uick CalcslDocuments THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N
j I
j - -
Duct. S em Summa
-�- wrightsoft y�t I � Date:
Entire House By:
QUICK CAL�CS,INC.
317 ST.LUCIE LN.,FT.PIERCE,IfL 34946 Phone:.772�66i6799:Fax 772-466-6796 Email:QUICKCALCS@/10LCOM j
Project Information
i
For. THE GRAND CARLTON
WYNNJ i EVELOPMENT, FT PIERCE, FL
i
Heating. Cooling .
External static pressure 0.50 in H2O 0.50 in HF20
Pressure losses 0 in H2O 0 in H2O
Available static pressure 0.50 in H2O 0.50 in H2O
Supply!'return available pressure I 0.250/0.250 in H2O 0.250/0.250 in H2O
Lowest friction rate. 0.265 in/100ft 0.285 in/100ft
Actual,air flow 1160 cfm 1160 cfm
Total effective length(TE ) ! 176 ft
Supply Detail
I II I
4esign Ht� Clg Design . Diam. H) W Duct Actual] . . Ftg.Egv.
Name (�tuh) (cfrr?) i (cfm) FR (in) (irk) Mat[ Ln(ft)! Ln(ft) Trunk
BATH h 560 �8 14 0.364 4.0 ox( VIFx 22.4.! 115.0 st1
BEDROOM 2 h 4702 232 232 0.360 7.0 Ox() VIFx 23.9 ' 115.0 st1
BEDROOM-A h 3327 1m 163 0.300 6.0 Ox0 VIFx 31.8 135.0 42
BEDROOM-B h 3327 160 163 0.285 6.0 Oxq VIFx 40.6 135.0 st2
FOYER h 1202 59 35 0.505 4.0 Ox a VIFx 4.0 95.0 1
GREAT/DINING h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 i 135.0 st2
GR EAT/DININGA h 3946 1�5 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2
;KITCHEN c 3437 21 153 0.379 6.0 Ox0 VIFx 17.01 .115.0 st1
LAUNDRY h 846 42 20 0.361 4.0 OxC VIFx 0.3 I 115..0 st1
M.BATH-A h 768 �3'11
834 0 0 Ox( VIFx 0 0
wlc c 174 8 0.309 4.0 Ox 01 VIFx 27.0.i 135.0 st2
SupplyDetail
I II I I I
I
Trunk ME Clg _ Design Veloc Diam H x W I Duct
Name Type (cfm), (cfm) FR (fpm) (in) I (in) Material Trunk
i
st2 Peak AVF 721 672 .0.285 918 12.d 0 x 0 VinlFlx s�t1
St-1 PeakAVF 1043 L: 11091 ' 0.285 1020 14. 0 x 0 VinlFlx
I
I
i
i
{ ; I
I
2017-Apr-11 09:29:38
wrightso a iRight-Suite®Uriivelsal 2017 17.0.14 RSU08101 Pa e 1
ACCA ...uick Calcs\Documents THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N 9
is I � I
i
I
i
i
i
DetailReturn Branch
I I
Grille F,tg Clg . I TEL Design Veloc Diam H x W Stud/Jgist Duct
Name Size(in) (clfm) (cfm) (ft) FR . (fpm). (in) . (in) Opening'(in) Matl Trunk
rb1 Ox 0 1160 1160 1 0 0 0 0 I Ox 0 VIFx .
� I
I
i
� I
� � I
i
i I
i
i
i
I
i
j .
i
I
I I
i
'I
I I
I
i
i
I
i I
I
wri htso I 2017-Apr-11 09:29:38
9 Right-Suite®Urlivelrsal 2017 17.0.14 RSU08101 Page 2
...uick Calcs\Documents THE GRAND CARLT N-11446.rup Cale=MJ8 Front Door faces: N
I I
i
I