HomeMy WebLinkAboutEngineering, truss plans ItsLumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber value g y s established by others. MITek® RE: M11323 - 62' Grand Carlton III with porch MiTek USA, Inc. Site Information: 6904 Parke East Blvd. Customer Info: WYNNNE DEVELOPEMENT CORP Project Name: M11323 ModelTIT1M610-4115 Lot/Block: Subdivision: Address: N/A City: PORT ST LUCIE State: FL Name Address and License#of Structural Engineer of Record, If there is one,for the building. Name: License #: Address: City: State: General Truss Engineering Criteria& Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2014/TP12007 Design Program: MiTek 20/20 7.6 Wind Code: ASCE 7-10 [All HeighII Wind Speed: 165 mph Roof Load: 37.0 psf Floor Load: N/A psf This package includes 13 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# Truss Name Date 1 IT9680954 A 10/17/16 2 I T9680955 (A5 1 10/17/16 13 I T9680956 A6 110/17/16 I (4 I T9680957 I A7 110/17/16 I 15 I T9680958 I A8 1 10/17/16 I 6 T9680959 A9 10/17/16 (7 T9680960 I GRA ( 10/17/16 I 18 I T9680961 I GRB 110/17/16 I 9 T9680962 I J2 110/17/16 10 T9680963 J4 , 10/17/16 1 11 (T9680964 I J6 ( 10/17/16 (12 I T9680965 (J8 110/17/16( . 113 I T9680966 I KJ8 110/17/16 I i i The truss drawing(s)referenced above have been prepared by MiTek , �N USA,Inc. under my direct supervision based on the parameters ����PQ . provided by Chambers Truss. .` �•.��G E IUS�.F�' Truss Design Engineer's Name: Velez, Joaquin ?"68182 ••i My license renewal date for the state of Florida is February 28,2017. IMPORTANT NOTE: The seal on these truss component designs is a certification =-10' that the engineer named is licensed in the jurisdiction(s)identified and that the 1 STATE OF It/ 4;designs comply with ANSI/TPI 1. These designs are based upon parameters ��,�•. ,p �/� shown(e.g.,loads,supports,dimensions,shapes and design codes),which were p R O P'•\��� given to MiTek. Any project specific information included is for MiTek's customers �i,ss •• '• �C',file reference designs. MiTek has not independently verified the applicability preparation i O N y f the design ''�� A these parameters or the designs for any particular building. Before use,the building designer Joaquin Velez PE No.68182 should verify applicability of design parameters and properly incorporate these designs MITek USA,Inc.FL Cert 6634 into the overall building design per ANSI/TPI 1,Chapter 2. 6904 Parke East Blvd.Tampa FL 33610 Date: October 17,2016 Velez,Joaquin 1 of 1 • i r PM1b Truss 71ruls Type Qty Ply 62'Grand Carlton III with porchT9680954 1323 A ON 9 1 Job Reference(optional) Chambers Truss, Fort Pierce,FL 7.640 s Apr 19 2016 MiTek Industries,Inc. Mon Oct 17 10:40:01 2016 Page i I D:a3B4PavKnnZweXyJckSFBgyuFUN-iMeaXsQ91 rHM W rvchxpgcTUSE1Md6iD2tQGCyMySYQy r1-0-Q 6-7-13 12-4-13 171-0 21-7-3 27-43 34-0-0 35.0-0 i-0-0 6-7-13 5-9-0 4-7-3 4-7-3 5-9-0 6-7-13 1-0-0 I Scale=1:59.2 4.00 12 44= 6 25 2x3 124 2x3 11 3x6% 5 7 3x6 8 3x4% 4 3x4 3 9 I I N1 2 10 11 `0 O 17 16 15 26 27 14 13 12 o 4x5— 2x3 I I 4x6= 3x8= 3x8= 4x6= 2x3 I I 4x5= i i 6-7-13 12-4-13 21-7-3 i 27-43 i 34-0-0 6-7-13 5-9-0 9-2-7 5-9-0 6-7-13 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Vdefl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.33 Vert(LL) 0.29 15 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.55 Vert(TL) -0.72 14-15 >567 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.54 Horz(TL) 0.14 10 n/a n/a BCDL 10.0 Code FBC2014/TP12007 (Matrix-M) Weight:163 lb FT=0% LUMBER- BRACING- TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 3-11-7 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 5-9-1 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1362/0-8-0,10=1362/0-8-0 Max Horz2=179(LC 7) Max Uplift2=-832(LC 8),10=-832(LC 8) FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=-3188/1833,3-4=2663/1558,4-5=2616/1565,5-24=-2668/1672,6-24=2608/1669, 6-25=-2608/1669,7-25=-2668/1672,7-8=2616/1565,8-9=-2663/1558,9-10=3188/1833 BOT CHORD 2-17=-1629/2972,16-17=1629/2972.15-16=-1629/2972,15-26=-934/1925, 26-27=934/1925,14-27=934/1925,13-14=1629/2972,12-13=-1629/2972, 10-12=-1629/2972 WEBS 6-14=-533/948,7-14=-328/317,9-14=550/387,6-15=-533/948,5-15=-328/317, 3-15=-550/387 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASIDE 7-10;Vult=165mph(3-second gust)Vasd=128mph;TCDL=4.2psf;BCDL=3.Opsf;h=14ft;B=52ft;L=34ft;eave=6ft Cat.II; Exp C;Encl.,GCpi=0.18;MW FRS(directional);Lumber DOL=1.60 plate grip DOL=1.60 3)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)`This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members,with BCDL=10.Opsf. 5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 832 lb uplift at joint 2 and 832 lb uplift at joint 10. 6)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. 7)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)50 lb down and 29 lb up at 15-0-0, and 50 lb down and 29 lb up at 19-0-0 on top chord. The design/selection of such connection device(s)is the responsibility of others. 8)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25 Uniform Loads(plf) Vert:1-6=-54,6-11=54,18-21=-20 . Concentrated Loads(lb) Vert:24=-50(F)25=50(F) ®WARNING-Verity design parameters end READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev.1010312015 BEFORE USE. Design valid for use only with MITek9 connectors.This design Is based only upon parameters shown,and Is for an Individual building component,not a truss system.Before use,the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall V bullding design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only.Additional temporary and permanent bracing Mffek' Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,seeANSi/TPI I Quality Criteria,DSB-89 and BCSI Building Component 6904 Parke East BlJd. Safety Information avallable from Truss Plate Institute,218 N.Lee Street,Suite 312.AJexandda,VA 22314. Tampa,FL 33610 I PMIb Truss Truss Type city Ply 62'Grand Carlton III with porchT9680955 1323 A5 SPECIAL 9 1 Job Reference(optional) Chambers Truss, Fort Pierce,FL I. 7.640 s Apr 19 2016 MiTek Industries,Inc. Mon Oct 17 10:40:03 2016 Page 1 1 ID:2GIScwwyY5hnGhXVARzUkuyuFUM-eliLyYSPZSX4m92-1Lr8huZhiZy4adbKKkll1 FySYOw r1-0-0 7-8-5 1011 17-0-0 20-4$ 26-4-0 34-0-0 135-0-0 1-0-0 7-8-5 2-9-15 6-5-12 31-11 5-11-8 7-8-0 Scale=1:61.2 4.00 12 5x8 II j 6 2x3 I I 20 II 7 j 4x6 55� 3x6 5 2x3� 4 8 3x4 3 9 14 10 11 �^ 5xl2 MT18HS= I6 6 6 13 12 5x12= 2x3 I 3x6= 3x10= 2.00 12 I 10-6-4 20-4.8 i 26-4-0 34.0-0 10-6-4 9-10-4 5-11-8 7-8-0 Plate Offsets(X,Y)-- f2:0-2-2,0-0-71,f4:0-3-0,Edgel LOADING(psf) SPACING- 2-0-0 I CSI. DEFL. in (loc) I/defl Ud PLATES GRIP, TCLL 20.0 Plate Grip DOL 1.25 TC 0.82 Vert(LL) 0.74 14 >553 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.87 Vert(TL) -1.48 13-14 >275 240 MT18HS 244/190 BCLL 0.0 ' Rep Stress Incr YES WB 0.49 Horz(TL) 0.43 10 n/a n/a BCDL 10.0 Code FBC2014/TP12007 (Matrix-M) Weight:154lb FTI=0% %LUMBER- BRACING- TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 4-3-11 oc bracing. WEBS 2x4 SP No.3*Except* WEBS 1 Row at midpt 6-14 6-14:2x4 SP M 30 REACTIONS, (lb/size) 2=1297/0-8-0,10=1327/0-8-0 j Max Horz2=179(LC 7) Max Uplift2=-795(LC 8),10=-812(LC 8) FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=-5402/3080,3-4=-5047/2830,4-5=5005/2833,5-6=-5093/2947,6-7=-2352/1498, 7-8=-2330/1420,8-9=-2383/1406,9-10=-2979/1705 BOT CHORD 2-14=-2837/5142,13-14=-990/2054,12-13=-1496/2765,10-12=1496/2765 WEBS 3-14=-342/309,5-14=297/306,6-14=-1796/3265,6-13=-246/514,7-13=-259/242, 9-13=-634/426 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=165mph(3-second gust)Vasd=128mph;TCDL=4.2psf;BCDL=3.Opsf;h=14ft B=52fh L=3411;eave=6ft;Cat.II; Exp C;Encl.,GCpi=0.18;MWFRS(directional);Lumber DOL=1.60 plate grip DOL=1.60 3)All plates are MT20 plates unless otherwise indicated. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord-and any other members. 6)Bearing at joint(s)2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 795 lb uplift at joint 2 and 812 Ito uplift at joint 10. 8)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. ®WARNING•Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 11411-7473 rev.1010312015 BEFORE USE Design valid for use only with MITek®connectors.This design is based only upon parameters shown,and is for an Individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and property Incorporate this design into the overall building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only.Additional temporary and permanent bracing MOTek• Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,seeANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information avaliable from Truss Plate Institute,218 N.Lee Street,Suite 312.Alexandda,VA 22314. Tampa,FL 33610 I Job Truss I T russ Type Qty Ply 62'Grand Carhon III with porch T9680956 M11323 A6 I SPECIAL 1 1 Job Reference(optional) Chambers Truss, Fort Pierce,FL 7.640 s Apr 19 2016 MiTek Industries,Inc. Mon Oct 17 10:40:04 2016 Pagel ` ID:2GIScwwyY5hnGhXVARzUkuyuFUM-6xJj9uT1 KmfxNJdBM3MNE56scyHtJ?2UZOVsZhySYQV 1-0- 9-11-11 16-0-0 18-0-0 20-1 25-11-15 34-0-0 5-0- -0-0 8-11-11 7-0-5 2-0-0 2-4-8 5-7-7 8-0-1 -0-0 ■ Scale:3/16°=1' • 4.00 12 6x8= 5x6= 5 6 2x3 3x4 5x6 WB 5x6 34 78 N r i 14 g N1 2 10 � r; r) 5xl2 MT18HS= 13 IcS 3x4:z 12 11 o Sx6= 20 1I 3x6 1 3xlO= 2.00 F12 i 10-6-4 15-0-0 6-0-0 20-4 8 25-11-15 34-0-0 10-6-4 4-5-12 -0-0 4-4-8 5-7-7 8-0-1 Plate Offsets_(X,Y)-- (2:0-2-2,0-0-71,13:0-3-0,Edgel,15:0-4-0,0-2-31,17:0-2-7,Edgel I LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.76 Vert(LL) 0.68 14 >601 360 MT20 244/1,90 ,TCDL 7.0 Lumber DOL 1.25 BC 0.90 Vert(fL) -1.13 14-17 >362 240 MT18HS 244/1.90 BCLL 0.0 Rep Stress Incr YES WB 0.79 Horz(TL) 0.41 9 n/a n/a I BCDL 10.0 CodeFBC2014f-P12007 (Matrix-M) Weight 156lb F11=0% LUMBER- BRACING- 'TOP CHORD 2x4 SP M 30`Except' TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. 3-5:2x4 SP M 31 BOT CHORD Rigid ceiling directly applied or 4-4-0 oc bracing. BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3`Except` 5-14:2x4 SP M 30 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 2=1298/0-8-0,9=1326/0-8-0 Max Horz2=169(LC 7) Max Uplift2=796(LC 8),9=-811(LC 8) FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=-5374/3073,3-4=5240/3075,4-5=4981/2826,5-6=-2255/1421,6-7=-2312/1390, i 7-8=-2320/1368,8-9=-3010/1736 BOT CHORD 2-14=-2825/5111,13-14=-1110/2301,12-13=-1043/2141.11-12=-152812799, 9-11=1528/2799 'WEBS 4-14=-487/484,5-14=-1581/2900,5-13=402/185,6-13=-166/517,8-12=-764/537, 8-11=0/257 NOTES- - 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=165mph(3-second gust)Vasd=128mph;TCDL=4.2psf;BCDL=3.Opsf;h=14ft;B=52ft;L=34fh eave=6fh Cat.II; Exp C;Encl.,GCpi=0.18;MW FRS(directional);Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)All plates are MT20 plates unless otherwise indicated. 5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)`This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7)Bearing at joint(s)2 considers parallel to grain value using ANSIfrPI 1 angle to grain formula. Building designer should verify capacity of beating surface. 8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 796 lb uplift at joint 2 and 811 lb uplift at joint 9. 9)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. 1 i ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE MI1.7473 rev.10103,2015 BEFORE USE Design valid for use only with MITek®connectors]This design is based only upon parameters shown,and is for an individual building ccomponent,not a truss system.Before use,the building designer must verify the applicability of design parameters and property incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing iVliTek� Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabdcallom storage,delivery.erection and bracing of trusses and truss systems,seeANSi/TPI l Quality Criteria,DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute,218 N.Lee Street.Suite 312,Alexandria,VA 22314. Tampa,FL 33610 i I I Job Truss Truss Type Qty Ply 62'Grand Carlton III with porch I T9680957 M11323 A7 SPECIAL 1 1 Job Reference(optional) Chambers Truss, Fort Pierce,FL 7.640 s Apr 19 2016 MiTek Industries,Inc. Mon Oct 17 10:4D:05 2016 Page 1 ` I D:WSJgpGwal Ppeur6hk9UjG5yuFU L-a7t5N ETf53no?TCNwmtcnJfOEMeV2Pldn1 EP58ySYQu r1-0-Q 8-10-10 14-0-0 20-0-0 i 25-11-15 34-0-0 35?0-0 1-0-0 8-10-10 5-1-6 6-0-0 5-11-15 8-0-1 1--0-0 1 Scale=1:62.3 I i 5x10= 5x6= 4.00 F12 4 5 2x3 3x4 3 6 N d 11 I ,n1 2 7 8 rn Ir Sx12 MT18HS= Icd 0 10 9 b 5x12= 2x3 I I 45= 3x10= 2.00 12 10-6-4 14-0-0 20-4-8 25-11-15 34-0-0 10-6-4 3-5-12 - 6-4-8 5-7-7 8-0-1 Plate Offsets(X Y)-- (2:0-2-2 0-0-71,(4:0-5-0,0-1-131 I LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIPI TCLL 20.0 Plate Grip DOL 1.25 TC 0.77 Vert(LL) 0.66 11 >623 360 MT20 244/190 -TCDL 7.0 Lumber DOL 1.25 BC 0.88 Vert(TL) -1.40 10-11 >291 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.99 Horz(TL) 0.41 7 n/a n/a BCDL 10.0 Code FBC2014/TP12007 (Matrix-M) Weight:147lb FTi=0% 'LUMBER- BRACING- TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 4-3-13 oc bracing. WEBS 2x4 SP No.3 I REACTIONS. (lb/size) 2=1297/0-8-0,7=1327/0-8-0 Max Horz 2=-1 49(LC 6) Max Uplift2=795(LC 8),7=-812(LC 8) FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=5357/3035,3-4=-4993/2805,4-5=-2157/1368,5-6=-2364/1410,6-7=2960/1697 BOT CHORD 2-11=2785/5096,10-11=1430/2801,9-10=-1486/2746,7-9=1486/2746 WEBS 3-11=-412/418,4-11=1327/2588,4-10=-810/415,5-10=-166/455,6-10=-636/444 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=165mph(3-second gust)Vasd=128mph;TCDL=4.2psf;BCDL=3.Opsf;h=14ft;B=52ft;L=34fh eave=6fh Cat.11; Exp C;Encl.,GCpl=0.18;MWFRS(directional);Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)All plates are MT20 plates unless otherwise indicated. 5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)`This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7)Bearing at joint(s)2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. i 8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 795 lb uplift at joint 2 and 812 lb uplift at joint 7. 9)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. I i • i I i ®WARNING-Verity design parameters and READ NOTES ON THIS AND INCLUDED M/TEK REFERANCE PAGE MII-7473 rev.1010312015 BEFORE USE. Design valid for use only with MlTeke connectors!This design Is based only upon parameters shown,and Is for an Individual building component,not a truss system.Before use.the building designer must verify the applicability of design parameters and properly Incorporate this design Into The overall binding design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek• Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and Truss systems,seeANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute,218 N.Lee Sheet.Suite 312.Alexandda VA 22314. Tampa,FL 33610 Job Truss Truss Type Qty Ply 62'Grand Carlton III with porch T9680958 M11323 AS SPECIAL 1 1 Job Reference(optional) Chambers Truss, Fort Pierce,FL 7.640 s Apr 19 2016 MiTek Industries,Inc. Mon Oct 17 10:40:07 2016 Page 1 ID:WSJgpGwalPpeur6hk9UjG5yuFUL-XW?sovVwdhl WEmM12Bw4skkNSAK2WNRWFLjWAOySYQs r1-0-Q 8-8-4 i 12-0-0 15-8-4 20-4-8 22-0-0 24-6-12 34-0-0 85-0-q 1-0-0 8-8-4 3-3-12 3-8-4 4-8-4 1-7-8 243-12 9-3-4 Scale=1:62.2 5x6= 3x4= 2x3 11 4x8= 4.00 12 4 20 5 6 21 7 2x3 1 2x3 8 3 t2 e ,n1 2 13 9 10 11� 5xl2 MT18HS= IM 6 6 12 11 5x12= 3x4= 4x6= 3x10'�w: 2.00 12 10-6-4 20-4-8 ,22-0-0 34-M 10-6-4 9-10-4 1-7-8 12-0-0 Plate Offsets(X Y)-- (2:0-2-2 0-0-71 (7:0-5-8,0-2-4),j9:0-2-6,Edgel LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.73 Vert(LL) 0.64 12-13 >642 360 MT20 244/190 :TCDL 7.0 Lumber DOL 1.25 BC 0.87 Vert(TL) -1.3612-13 >301 240 MT18HS 244/190 BCLL 0.0 ' Rep Stress incr YES WB 0.69 Horz(TL) 0.39 9 n/a n/a I BCDL 10.0 Code FBC2014/TPI2007 (Matrix-M) Weight:154lb FT=0% LUMBER- BRACING- TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc puriins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 4-3-14 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1292/0-8-0,9=1332/0-8-0 Max Horz2=129(LC 7) Max Uplift2=-794(LC 8),9=813(LC 8) FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=-5337/3033,3-4=-4970/2788,4-20=-3801/2193,5-20=-3801/2193,5-6=-2464/1521, 6-21=-2472/1529,7-21=2472/1529,7-8=-2492/1487,8-9=-2808/1655 BOT CHORD 2-13=-2785/5078,12-13=-1698/3180,11-12=1158/2331,9-11=-1432/2593 WEBS 3-13=-389/395,4-13=-895/1665,5-13=-291/796,5-12=-894/538,7-12=-303/452, 7-11=-228/474,8-11=408/405 i NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=165mph(3-second gust)Vasd=128mph;TCDL=4.2psf;BCDL=3.Opsf;h=14ft;B=52ft;L=34ft;eave=6ft;Cat.11; Exp C;Encl.,GCpi=0.18;MW FRS(directional);Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)All plates are MT20 plates unless otherwise indicated. 5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)`This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7)Bearing at joint(s)2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 794 lb uplift at joint 2 and 813 lb uplift at joint 9. 9)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. I I i I ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev.1010MO15 BEFORE USE. Design valid for use only with MITek®connectors!This design is based only upon parameters shown,and Is for an Individual building component.not a truss system.Before use,the building designer must verify the applicability of design parameters and property incorporate this design Into the overall r building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possble personal Injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,seeANSI/TPI l Quality Criteria,DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate institute.218 N.Lee Street,Suite 312.Alexandria VA 22314. Tampa,FL 33610 I _ I Job Truss Truss Type city PV 62'Grand Carlton III with porch T9660959 M11323 A9 HIP 1 1 Job Reference o tional Chambers Truss, Fort Pierce,FL 7.640 s Apr 19 2016 MiTek Industries,Inc. Mon Oct 17 10:40:08 2016 Pagel t I D:_etC 1 cxC3ixVV?huls?ypJyuFUK-?iZE?F WYO_9MswxybvRJOxHgpalH FnB4U?T3iSySYQr 1-0- 6-7-15 10-0-0 152-14 20-4-0 24-0-0 27-4-1 34-0-0 5-0 Q 1-0-0 6-7-15 1 3-4-1 5-2-14- 5-1-2 3-8-0 3-4-1 6-7-15 '1-0 0 Scale=1:60.1 I i 4x4= 2x3 I 4x8= 4.00 12 3x4= 4 22 5 6 23 7 2x3 2x3 3 8 N I f` N1 2 9 10 N Im o — o 15 14 13 12 11 3x5= 3x8 3x6= 6x8 3x6= 3x4= 3x5= i i I 10-0-0 20-4-0 24-0-0 34-0-0 10-0-0 10-4-0 3-8-0 10-0-0 Plate Offsets(X Y)-- f2:0-2-8 Edged f7:0-5-4 0-2-01 [9:0-2-2 Edge] LOADING(psf) SPACING- 2-0-0 CSL I DEFL. in (loc) I/defl Ud PLATES GRIP, TCLL 20.0 Plate Grip DOL 1.25 TC 0.24 Vert(LL) -0.17 13-15 >999 360 MT20 244/1'90 TCDL 7.0 Lumber DOL 1.25 BC 0.49 Vert(TL) -0.42 13-15 >574 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.85 Horz(TL) 0.02 13 n/a n/a BCDL 10.0 Code FBC2014/TP12007 (Matrix-M) Weight:156lb FTi=0% LUMBER- BRACING- I TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=68710-8-0,9=382/0-8-0,13=1554/0-8-0 Max Horz2=-109(1_C 6) Max Uplift2=-441(LC 8),9=262(LC 8),13=-904(LC 8) Max Grav2=709(LC 17),9=420(LC 18),13=1554(LC 1) FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=-1196/685,3-4=-874/475,4-22=-797/472,5-22=-797/472,5-6=-369/747, 6-23=-369/747,7-23_369/747,7-8=78/269,8-9=-295/175 BOT CHORD 2-15=-543/1091,14-15=-39/316,13-14—39/316,12-13=-245/259,11-12=245/259 WEBS 3-15=349/338,5-15=-256/615,5-13=-1162/752,6-13=-260/229,7-11=-156/325, 8-11=-387/359,7-13=762/448 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=165mph(3-second gust)Vasd=128mph;TCDL=4.2psf;BCDL=3.Opsf;h=14ft B=52ft L=34ft;eave=6ft;Cat.II; Exp C;Encl.,GCpi=0.18;MW FRS(directional);Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)`This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will I fit between the bottom chord and any other members. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 441 lb uplift at joint 2,262 lb uplift at joint 9 and 904 lb uplift at joint 13. 7)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. I I i I I ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev.1010312015 BEFORE USE. Design valid for use only with MITek®connectors.This design Is based only upon parameters shown,and Is for an individual building component,not �A® a truss system.Before use,the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall _p��'Y� building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only.Additional temporary and permanent bracing M iTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,seeANSI/TPII Quality Criteria,DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information avallabte from Truss Plate Institute,218 N.Lee Street,Suite 312.Alexandria VA 22314. Tampa,FL 33610 I Job Truss Truss Type Qty Ply 62'Grand Carlton III with porch T9680960 M11323 GRA HIP 1 1 Job Reference(optional) Chambers Truss, Fort Pierce,FL ! 7.640 s Apr 19 2016 M!Tek Industries,Inc. Mon Oct 17 10:40:09 2016 Page 1 I D:_etC 1 cxC3ixVV?huls?ypJyuFUK-Tv7cDbWA91HD U4 W 89cyYxgpgDz6A_CfDifCdEvySYQq t1.0-Q 8-0-0 11-1-1 17-0-0 1116-0 22-2-2 26-0-0 34-0-0 35-0-0 1-0-0 8-0-0 3-1-1 5-10-15 1-6-0 3-8-2 3-9-14 8-0-0 1-0-0 I Scale=1:62.3 TOP CHORD MUST BE BRACED BY END JACKS, THIS COMPONENT IS TO BE USED IN ROOF DIAPHRAGM,OR PROPERLY CONNECTED CONJUNCTION WITH A RIGID DIAPHRAGM. PURLINS AS SPECIFIED. 44= THIS DIAPHRAGM MUST BE CAPABLE OF TRANSFERRING ROOF LOADS TO THE GROUND 11 14 WITH NEGLIGIBLE LATERAL DEFLECTIONS. T 9 7x10 6 /p 17 6x10 4.00 F12 4 3x6 19 3 = 131 16- Sx 21 - 10 - N ' N 1 2 22 23 N N I 0 0 29 28 25 27 26 24 3x6 II 3x6= 6x8= 3x6= 6x8= 4x4= 3x5= 6x8= i 8-0-0 11-1-1 18-6-0 26-0-0 r 34-0-0 8-0-0 3-1-1 7-4-15 7-6-0 Plate Offsets(X Y)-- [3:0-3-8 Edge) [21:0-3-8 Edge) [24:0-3-8 0-3-0) [27:0-3-8 0-3-0) I LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udefl Ud PLATES GRIP TOLL 20.0 Plate Grip DOL 1.25 TC 0.90 Vert(LL) 0.10 24-35 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.44 Vert(TL) -0.19 24-26 >987 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.96 Horz(TL) 0.02 22 n/a n/a BCDL 10.0 Code FB02014[TP12007 (Matrix-M) Weight:1941b FT=0% I LUMBER- BRACING- TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 4-7-4 oc pudins. Except: BOT CHORD 2x4 SP M 30 1 Row at midpt B-21 WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. JOINTS 1 Brace at Jt(s):7,8,19,17,14 REACTIONS. All bearings 0-8-0. I (Ib)- Max Horz 2=179(LC 7) Max Uplift All uplift 100 lb or less at joint(s)except 2=-376(LC 8),27=-1146(LC 8),26=-1470(LC 8),22=646(LC 8) Max Grav All reactions 250 lb or less at joint(s)except 2=527(LC 13),27=2197(LC 13),26=2894(LC 14), 22=1015(LC 14) FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=-561/338,3-5=-306/839,5-7=-584/1206,7-8=-584/1206,8-10=-584/1206, 10-12=-584/1206,12-13=584/1206,13-15=584/1206,15-16=-584/1206, 16-18=-584/1206,18-20=-2121/1203,20-21=-2121/1203,21-22=2176/1197, 4-6=-173/256,6-9=134/313,9-11=114/371,11-14=200/419,14-17=-102/280, 19-21=151/268 BOT CHORD 2-29=-195/591,28-29=143/463,27-28=143/463,26-27=772/440,25-26=-393/630, 24-25=-393/630,22-24=-1014/2010 WEBS 3-29=457/1105,3-27=1643/836,5-27=-769/636,5-26=-537/3461 13-26=934/608, 18-26=-2360/1437,18-24=-782/1690,21-24=-38/353,4-5=-618/520,19-20=342/310, 14-15=-549/402 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=165mph(3-second gust)Vasd=128mph;TCDL=4.2psf;BCDL=3.Opsf;h=14ft;B=52fh L=34ft eave=6ft;Cat.11; Exp C;Encl.,GCpi=0.18;MW FRS(directional);Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)All plates are 2x3 MT20 unless otherwise indicated. 5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 376 lb uplift at joint 2,1146 lb uplift at joint 27,1470 lb uplift at joint 26 and 646 lb uplift at joint 22. 811"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. 9)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)967 lb down and 461 lb up at 26-0-0,and 967 lb down and 461 Ito up at 8-0-0 on bottom chord. The design/selection of such connection device(s)is the responsibility of others. 11)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). C S Standard WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 11111-7473 rev.1010312015 BEFORE USE. Design valid for use only with MITek®connectors.This design Is based only upon parameters shown,and Is for an Individual building component,not a tmss system.Before use.the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall t�v i building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,seeANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute,218 N.Lee Street.Suite 312 Alexandria.VA 22314. Tampa,FL 33610 I I �Mib1323 o Truss Truss Type Qty Ply 62'Grand Carlton III with porch i T9680960 GRA ' 1 1 Job Reference(optional) • Chambers Truss, Fort Pierce,FL 7.640 s Apr 19 2016 MiTek Industries,Inc. Mon Oct 17 10:40:09 2016 Page 2 I D:_etC 1 cxC3ixVV?huls?ypJyuFUK-Tv7cDbWA91 H D U4W B9cyYx9pgDz6ALCfDifCdEvySYQq LOAD CASE(S) Standard 1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25 Uniform Loads(plf) Vert:1-3=-54,21-23=-54,29-30=-20,24-29=-47(1`=-27),24-33=-20,3-11=-126(F=-72),11-21=126(F=72) Concentrated Loads(lb) Vert:29=-641(F)24=-641(F) i I I I I I I I � I I i ®WARNING-Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev.1010312016 BEFORE USE Design valid for use ody with MITek®connectors!This design Is based only upon parameters shown,and Is for an Individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,seeANSI/TPI I Quality Criteria,DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute.218 N.Lee Street Suite 312,Alexandria VA 22314. Tampa,FL 33610 — f Job Truss Truss Type city Ply 62'Grand Carlton III with porch T9680961 M11323 GRB HIP 1 1 Job Reference(optional) Chambers Truss, Fort Pierce,FL 7.640 s Apr 19 2016 MiTak Industries,Inc. Mon Oct 17 10:40:09 2016 Page 1 I D:SrRaEyyrgO4M78G4raW BLWyuFUJ-Tv7cDbWA91 H D U4W 89cyYx9piuz4F_CM DifCdEvySYQq 1-0 0 B-0-0 13-8-0 17-0-0 20 4 0 26-0-0 34-0-0 35-0-0 1-0-0 8-0-0 5-8-0 3-4-0 3-4-0 5-8-0 8-0-0 1.0-0 Scale=1:60.1 II 5x8 MT18HS= 4x10= 5x8 MT18HS= 4.00 12 2x3 II 4x6= 2x3 II 3 23 4 5 6 7 24 8 10!;2 N Im o E9d E9d o 16 15 14 13 12 11 4x5= 3x6 11 4x6_ 6x10= 6x10— 4x6= 3x6 II 4x5— I I 8-0-0 13-8-0 20-4-0 26-0-0 34-0-0 1 8-0-0 5-8-0 6-8-0 5-8-0 8-0-0 Plate Offsets(X,Y)-- r2:0-2-2,Edge],f3:0-5-4,0-2-81,[5:0-3-0,Edge],f8:0-5-4 0-2-81,(9:0-2-2,Edge) LOADING(psf) SPACING- 2-0-0 CS1. DEFL. in (loc) Udefl Ud PLATES GRIP, TCLL 20.0 Plate Grip DOL 1.25 TC 0.79 Vert(LL) 0.16 16 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.57 Vert(TL) -0.27 14-16 >912 240 MT18HS 244/190 BCLL 0.0 ' Rep Stress Incr NO WB 0.98 Horz(TL) 0.07 9 n/a n/a BCDL 10.0 Code FBC20141TP12007 (Matrix-M) Weight:153lb FT=0 LUMBER- BRACING- TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 3-7-9 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 5-8-1 oc bracing. WEBS 2x4 SP No.3'Except* WEBS 1 Row at midpt 8-13,6-13 4-14,7-13:2x6 SP No.2 REACTIONS. (lb/size) 2=1296/0-8-0,13=3993/0-8-0,9=510/0-8-0 Max Horz 2=-90(LC 6) Max Uplift2=-871(LC 8),13=-2549(LC 8),9=369(LC 8) Max Grav2=1479(LC 13),13=4684(LC 15),9=563(LC 14) FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=3514/1878,3-23=-2062/1226,4-23=2062/1226,4-5=2062/1226,5-6=-2062/1226, 6-7=-1265/2545,7-24=1265/2545,8-24=-1265/2545,B-9=-692/331 BOT CHORD 2-16—1655/3336,15-16=-1676/3398,14-15=-1676/3398,12-13=-246/658, 11-12=-246/658,9-11=-225/595 WEBS 3-16=-402/1155,3-14=1431l700,4-14=-847/699,7-13=886/720,8-13=-3505/1836, 8-11—403/1157,6-14=-1431/2780,6-13=-3151/1776 NOTES- 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=165mph(3-second gust)Vasd=128mph;TCDL=4.2psf;BCDL=3.Opsf;h=1411h B=52fh L=34ft;eave=6ft;Cat.II; Exp C;Encl.,GCpi=0.18;MW FRS(directional);Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)All plates are MT20 plates unless otherwise Indicated. 5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)`This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 871 lb uplift at joint 2,2549 lb uplift at joint 13 and 369 lb uplift at joint 9. 8)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. 9)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)967 lb down and 461 lb up at 26-0-0,and 967 lb down and 461 lb up at 8-0-0 on bottom chord. The design/selection of such connection device(s)is the responsibility of others. 10)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S)Standard 1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25 Uniform Loads(pit) Vert:1-3=-54,3-8=-131(F=-77),8-10=-54,16-17=-20,11-16=-49(F=-29),11-20=20 i ®WARNING-Verily design parameters and READ NOTES ON THIS AND INCLUDED M/TEK REFERANCE PAGE MI1-7473 rev.10/03/2015 BEFORE USE. , Design valid for use only with MiTek®connectors!This design is based only upon parameters shown,and Is for on Individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall Iva 1 building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and txacing of trusses and truss systems,seeANSI/TPI1 Quality Cdterta,DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute,218 N.Lee Street Suite 312.Alexandria.VA 22314. Tampa,FL 33610 I PbTruss Truss Type Qty Ply 62'Grand Carlson III with porch T9680961 M11323 GRB HIP 1 1 Job Reference(optional) Chambers Truss, Fort Pierce,FL 7.640 s Apr 19 2016 MiTek Industries,Inc. Mon Oct 17 10:40:1 0 2016 Page 2 I D:SrRaEyyrg04M78G4raW BLW yuFUJ-x5h_QxXowcP45E5KjJTnUMMteNQUjfcMxJyAnLySYQp i LOAD CASE(S) Standard Concentrated Loads(lb) Vert:16=-641(F)11=-641(F) I i I I i I I I I I I II I r , I ®WARNING-Verity design parameters and READ NOTES ON THIS AND INCLUDED M?EK REFERANCE PAGE M/h7473 rev.10/03/2015 BEFORE USE i Design valid for use only with MITekO connectors!This design is based only upon parameters shown,and Is for an individual building component not a truss system.Before use,the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall � building design. Bracing Indicated Is to prevent buckling of Individual truss web p and/or chord members only.Additional temporary and permanent bracing iTek' Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,seeANSI/TPI I Quality Criteria,DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute,218 N.Lee Street.Suite 312.Alexandria.VA 22314. Tampa,FL 33610 I I I Job Truss Truss Type Qty Ply 62'Grand Carlton III with porch T9680962 M11323 J2 MONO TRUSS 8 1 Job Reference(optional) Chambers Truss, Fort Pierce,FL 7.640 s Apr 19 2016 MiTek Industries,Inc. Mon Oct 17 10:40:10 2016 Page 1 I D:x1?zSlzTbJCDIIrGPH i QukyuFU l-x5h_QxXowc P45E5KjJTnU MM21NYIjuxMxJyAnLySYQp 1-0-0 2-0-0 10 0 2-0-0 j Scale=1:7.9 3 4.00 12 2 1 i 4 3x4= 2-0-0 2-0-0 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.11 Vert(LL) -0.00 7 >999 360 MT20 244/19t) TCDL 7.0 Lumber DOL 1.25 BC 0.04 Vert(TL) -0.00 7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 2 n/a n/a BCDL 10.0 Code FBC2014/TP12007 (Matrix-M) I Weight:8lb FT=0% LUMBER- BRACING- ,TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc puriins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS: (lb/size) 3=37/Mechanical,2=143/0-8-0,4=21/Mechanical Max Horz2=67(LC 8) Max Uplift3=-30(LC 8),2=-131(LC 8),4=3(LC 5) Max Grav3=37(LC 13),2=143(LC 1),4=29(LC 3) i FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Wind:ASIDE 7-10;Vult=165mph(3-second gust)Vasd=128mph;TCDL=4.2psf;BCDL=3.Opsf;h=14ft B=52ft;L=3411t;eave=6ft Cat.11; Exp C;Encl.,GCpi=0.18;MW FRS(directional);Lumber DOL=1.60 plate grip DOL=1.60 2)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)`This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. -4)Refer to girder(s)for truss to truss connections. 5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 30 lb uplift at joint 3,131 lb uplift at joint 2 and 3 lb uplift at joint 4. 6)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. I ®WARNING-Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev,10/03/2015 BEFORE USE- Design valid for use only with MITekO connectors!This design Is based only upon parameters shown,and Is for an Individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only.Additional temporary and permanent bracing Mffek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,seeANSI/TPII Quality Criteria,DSE-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 31Z Alexandria.VA 22314. Tampa,FL 33610 Job Truss Truss Type city Ply 62'Grand Carlton III with porch T9680963 M11323 J4 MONOTRUSS 8 1 Job Reference(optional) Chambers Truss, Fort Pierce,FL 7.640 s Apr 19 2016 MiTek Industries,Inc. Mon Oct 17 10:40:10 2016 Page 1 j I D:PDYLfd_5MdK4MSQTz?Zf RxyuFU H-x5h_WowcP45E5KjJTnU MMOdN W ej uxMxJyAnLySYQp -1-0-0 I 4-0-0 1-0-0 4-0-0 Scale=1:11.2 3 4.0D 12 I 2 1 , 4 3x4= 4-0-0 r 4-0-0 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.22 Vert(LL) -0.01 4-7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.17 Vert(TL) -0.02 4-7 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(fL) 0.00 2 n/a n/a BCDL 10.0 Code FBC2014/TP12007 (Matrix-M) Weight:14lb FT=0 LUMBER- BRACING- TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=79/Mechanical,2=229/0-8-0,4=39/Mechanical Max Horz2=104(LC 8) Max Uplift3=-75(LC 8),2=-171(LC 8),4=-2(LC 8) Max Grav3=79(LC 1),2=229(LC 1),4=60(LC 3) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust)Vasd=128mph;TCDL=4.2psf;BCDL=3.Opsf;h=14ft;B=52ft;L=34ft eave=6ft;Cat.11; Exp C;Encl.,GCpi=0.18;MWFRS(directional);Lumber DOL=1.60 plate grip DOL=1.60 2)This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will tit between the bottom chord and any other members. .4)Refer to girder(s)for truss to truss connections. 5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 75 lb uplift at joint 3,171 lb uplift at joint 2 and 2 lb uplift at joint 4. 6)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. i i i I ' ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev,10/03/2015 BEFORE USE. Design valid for use only with MiTek®connectors.This design Is based only upon parameters shown,and Is for an Individual building component,not a truss system.Before use.the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall iVliTek� building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only.Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrk;atlon,storage,delivery,erection and bracing of trusses and truss systems,seeANSI/TPI I Quality Criteria,DSE-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute,218 N.Lee Street.Suite 312 Alexandria.VA 22314. Tama,FL 33610 • i ' Job Truss Truss Type Qty Ply 62'Grand Carlton III with porch ' T9680964 M11323 J6 MONO TRUSS 8 1 Jab Reference(optional Chambers Truss, Fort Pierce,FL 7,640 s Apr 19 2016 MiTek Industries,Inc. Mon Oct 17 10:40:11 2016 Page 1 I D:tP6jtz_j7xSx_c_fXi4uz9yuFUG-PHEMd HYQgvXxjOgXH 1_10av6FnozSLAWAzhkJnySYQo -1-0-0 6-0-0 1-0-D �' 6-0-0 Scale=1:14.8 3 4.0D 12 2 1 4 3x4= 6-0-0 6-0-0 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.55 Vert(LL) 0.04 4-7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.42 Vert(TL) -0.09 4-7 >790 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 2 n/a n/a BCDL 10.0 Code FBC2014/TPI2007 (Matrix M) Weight:20 lb FT=0% LUMBER- BRACING- TOP CHORD 2x4 SP N0.3 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP N0.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=120/Mechanical,2=321/0-8-0,4=54/Mechanical Max Horz2=142(LC 8) Max Upl1ft3—117(LC 8),2=218(LC 8) Max Grav3=120(LC 1),2=321(LC 1),4=89(LC 3) FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust)Vasd=128mph;TCDL=4.2psf;BCDL=3.Opsf;h=14ft B=52fh L=34ft;eave=6ft;Cat.Il; Exp C;Encl.,GCpi=0.18;MWFRS(directional);Lumber DOL=1.60 plate grip DOL=1.60 2)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)'This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will tit between the bottom chord and any other members. 4)Refer to girder(s)for truss to truss connections. 5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 117 lb uplift at joint 3 and 218 lb uplift at joint 2. 6)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. I I LING•Verity design parametrs and READ NOTES ON THIS AND INCLUDED M?EKREFERANCE PAGE Ml!•7473 rev.70/03/2015 BEFORE USElid for use only with MITek®connectors.This design Is based only upon parameters shown,and Is for an Individual building component,nottem.Before use,the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall esign. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek I required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the n,storage,delivery,erection and bracing of trusses and truss systems,seeANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 6904 Parke East BNd. ormatlon available from Truss Plate Institute,218 N.Lee Street,Suite 312.Alexandra,VA 22314. Tampa,FL 33610 Job Truss Truss Type Qty Pty 62'Grand Carlton III with porch T9680966 Ml1323 JS MONO TRUSS 20 1 Job Reference(optional) Chambers Truss, Fort Pierce,FL 7.640 s Apr 19 2016 MiTek Industries,Inc. Mon Oct 17 10:40:11 2016 Page 1 I D:tP6j tz_j7xSx_c_fXi4uzgyuFUG-PHEMdHYQgvXujOgXH 1_10av9TniQSLAWAzhkJnySYQo -1-0-0 8-0-0 1-0-0 8-M Scale=1:17.7 3 4.00 12 I 2 1 I 4 3x4= 8-" 8-0-0 Plate Offsets(X,Y)-- f2:0-1-2,Edgel LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udefl - Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.34 Vert(LL) -0.10 -4-7 >972 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.78 j Vert(TL) -0.27 4-7 >350 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) 0.01 2 n/a n/a BCDL 10.0 Code FBC20141TP12007 (Matrix-M) Weight:26lb FT,=0% LUMBER- BRACING- TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 5-11-4 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=164/Mechanical,2=411/0-8-0,4=68/Mechanical Max Horz2=180(LC 8) Max Uplift3=-160(LC 8),2=265(LC 8) Max Grav3=164(LC 1),2=411(LC 1),4=118(LC 3) FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust)Vasd=128mph;TCDL=4.2psf;BCDL=3.Opsf;h=14ft;13=521t;L=34fh eave=6ft;Cat.II; Exp C;Encl.,GCpi=0.18;MW FRS(directional);Lumber DOL=1.60 plate grip DOL=1.60 2)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)`This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4)Refer to girder(s)for truss to truss connections. 5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 160 lb uplift at joint 3 and 265 lb uplift at joint 2. 6)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. i I i I I ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED mfrEK REFERANCE PAGE MIF7473 rev.10103/2015 BEFORE USE. Design valld for use only with MITek®connectorsi This design is based only upon parameters shown,and Is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall 9 h PP tY 9 Pa P Pe Y � 9 � building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and tniss systems.seeANSI/TPI I Quality Criteria,DSB-89 and BCSI Building Component 6904 Parke East Blvd: Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312.Alexandria VA 22314. Tampa,FL 33610 it I I Job Truss Truss Type city Ply . 62'Grand Carlton III with porch � T9680966 Ml 1323 KJ8 MONO TRUSS 4 1 Job Reference(optional) Chambers Truss, For[Pierce,FL 7.640 s Apr 19 2016 MiTek Industries,Inc. Mon Oct 17 10:40:11 2016 Pagel I D:Lcg54J?LuEancmZr4Qb7W MyuFUF-PHEMdHYQgvXxjOgXH 1_10avAingZSFRWAzhkJnySYQo i -1-5-0 i 7-3-4 11-3-0 1 1-5-0 7-3-4 3-11-12 Scale=1:20.8 4 2.83 12 3x4 3 i l c 2 cl 7 6 2x3 I 3x4= 5 3x4= i 7-3-4 11-3-0 { 7-3-4 3-11-12 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.26 Vert(LL) 0.05 7-10 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.26 Vert(TL) -0.11 7-10 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.43 Horz(TL) 0.02 6 n/a n/a BCDL 10.0 Code FBC2014ITP12007 (Matrix-M) Weight:44lb FT{=0% LUMBER- BRACING- ,TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pu Ilins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 9-0-4 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 4=207/Mechanical,2=482/0-11-5,6=556/Mechanical Max Horz2=244(LC 8) Max Uplift4=-207(LC 8),2=312(LC 8),6=277(LC 8) Max Grav4=250(LC 13),2=482(LC 1),6=574(LC 13) FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=-1090/498 BOT CHORD 2-7=-662/1072,.6-7=-662/1072 WEBS 3-7=0/309,3-6=-1177/727 NOTES- 1)Wind:ASCE 7-10;Vult=165mph(3-second gust)Vasd=128mph;TCDL=4.2psf;BCDL=3.Opsf;h=14ft;B=52ft;L=34ft;eave=6ft;Cat.II; Exp C;Encl.,GCpi=0.18;MW FRS(directional);Lumber DOL=1.60 plate grip DOL=1.60 '2)na 3)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)`This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5)Refer to girder(s)for truss to truss connections. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 207 lb uplift at joint 4,312 lb uplift at joint 2 and 277 lb uplift at joint 6. 7)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. 8)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25 Uniform Loads(pif) Vert:1-2=-54 Trapezoidal Loads(Pit) Vert:2=0(F=27,B=27)-to-4152(F=-49,B=49),8=0(F=10,B=10)-to-5=-56(F=18,B=-18) I ®WARNING-Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE MII--7473 rev 1010312015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and Is for an Individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,seeANSI/TPI1 Quality Criteria,DSE-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute,218 N.Lee Street.Suite 312.Alexandria,VA 22314. Tampa,FL 33610, i Symbols Numbering System General Safety Notes PLATE LOCATION AND ORIENTATION 3 " Center plate on joint unless x,y 6-4-8 dimensions shown in ft-in-sixteenths Failure to Follow Could Cause Property /4__ —_-_ (Drawings-not to scale)_ -Damage or Personal-Injury-- - --- - -- -- -- - - offsets are indicated. - - - - - -- g J ry Dimensions are in ff-in-sixteenths. Apply plates to both sides of truss 1 2 3 1. Additional stability bracing for truss system,e.g. and fully embed teeth. TOP CHORDS diagonal or X-bracing,is always required. See BCSI. 1 r C1-2 C2-3 2. Truss bracing must be designed by an engineer.For WEBS 4 wide truss spacing,individual lateral braces themselves may require bracing,or alternative Tor I � p � v p bracing should be considered. a b 3. Never exceed the design loading shown and never a �p U U stack materials on inadequately braced trusses. 0 a- 4. Provide copies of this truss design to the building For 4 x 2 orientation, locate C7-8 C6a c5a 0 designer,erection supervisor,property owner and plates 0-1/0 from outside BOTTOM CHORDS all other interested parties. edge of truss. 8 7 6 5 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each This symbol indicates the JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE joint and embed fully.Knots and wane at joint required direction of slots in AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO locations are regulated by ANSI/TPI 1. Connector plates. THE LEFT. 7. Design assumes trusses will be suitably protected from CHORDS AND WEBS ARE IDENTIFIED BY END JOINT the environment in accord with ANSI/TPI 1. `Plate location details available in MiTek 20/20 NUMBERS/LETTERS. software or upon request. 8. Unless otherwise noted,moisture content of lumber shall not exceed 19%at time of fabrication. PLATE SIZE PRODUCT CODE APPROVALS 9. Unless expressly noted,this design is not applicable for ICC-ES Reports: use with fire retardant,preservative treated,or green lumber. The first dimension is the plate 10.Camber is a non-structural consideration and is the width measured perpendicular ESR-1311, ESR-1352, ESR1988 responsibility of truss fabricator.General practice is to 4 x 4 to slots.Second dimension is ER-3907, ESR-2362, ESR-1397, ESR-3282 camber for dead load deflection. the length parallel to slots. 11.Plate type,size,orientation and location dimensions indicated are minimum plating requirements. LATERAL BRACING LOCATION 12.Lumber used shall be of the species and size,and in all respects,equal to or better than that Indicated by symbol shown and/or Trusses are designed for wind loads in the plane of the specified. by text in the bracing section of the truss unless otherwise shown. 13.Top chords must be sheathed or purllns provided at output. Use T or 1 bracing spacing indicated on design. if indicated. Lumber design values are in accordance with ANSI/TPI 1 14.Bottom chords require lateral bracing at 10 ft.spacing, section 6.3 These truss designs rely on lumber values or less,if no ceiling is installed,unless otherwise noted. BEARING established by others. 15.Connections not shown are the responsibility of others. Indicates location where bearings 16.Do not cut or alter truss member or plate without prior '��no (supports)occur. Icons vary but ©2012 MiTek®All Rights Reserved approval of an engineer. reaction section indicates joint number where bearings occur. 17.Install and load vertically unless indicated otherwise. Min size shown is for crushing only. �� 18.Use of green or treated lumber may pose unacceptable RHenvironmental,health or performance risks.Consult with Industry Standards: project engineer before use. ANSI/TPI1: National Design Specification for Metal 19.Review all portions of this design(front,back,words Plate Connected Wood Truss Construction. and pictures)before use.Reviewing pictures alone DSB-89: Design Standard for Bracing. is not sufficient. BCSI: Building Component Safety Information, MiTek 20.Design assumes manufacture in accordance with Guide to Good Practice for Handling, ANSI/TPI 1 Quality Criteria. Installing&Bracing of Metal Plate Connected Wood Trusses. MiTek Engineering-Reference Sheet:Mll-7473 rev. 10/03/2015