Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Generator Product info
e GENERACp 16/20/22 kW GUARDIAN® SERIES - Residential Standby Generators Air-Cooled Gas Engine INCLUDES: Standby Power Rating • True Power" Electrical Technology Models G007036-0, G007037-0(Aluminum - Bisque) - 16 kW 60 Hz • Two Line LCD Multilingual Digital Model G007035-0 (Aluminum- Bisque) - 16 kW 60 Hz Evolution ' Controller (English/Spanish/ Models G007039-0, G007038-0 (Aluminum- Bisque) -20 kW 60 Hz French.Portuguese) Models G007043-0, G007042-0(Aluminum - Bisque) -22 kW 60 Hz • Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. See Page 4 for Details. • Electronic Governor • System Status & Maintenance Interval LED Indicators • Sound Attenuated Enclosure GENERAC' • Flexible Fuel Line Connector • Direct-To-Dirt Composite Mounting Pad • Natural Gas or LP Gas Operation • 5 Year Limited Warranty c(&s QUIETqTS • Capability to be installed within 18" (457 mm) LISTED of a building* Note:CUL certification only applies to unbundled units and units packaged with limited circuit g switches.Units packaged with the Smart Switch are UL certified in the USA only. *Only if located away from doors,windows and fresh air intakes,and unless other- wise directed by local codes. FEATURES iNNUVAT!VE DESIGN&PROTOTYPE TESTING are key components of O SOLID-STATE,FREQUENCY COMPENSATED VOLTAGE REGULATION.This state- GENERAC'S success in"IMPROVING POWER BY DESIGN."But it doesn't of-the-art power maximizing regulation system is standard on all Generac models.It slop there. Total commitment to component testing,reliability testing, provides optimized FAST RESPONSE to changing load conditions and MAXIMUM environmental testing,destruction and life testing,plus testing to applicable MOTOR STARTING CAPABILITY by electronically torque-matching the surge CSA.NEMA,EGSA,and other standards,allows you to choose GENERAC loads to the engine.Digital voltage regulation at±1%. POWER SYSTEMS with the confidence that these systems will provide superior performance. O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive deafer network provides parts and service know-how for the entire unit, from the engine to the 1 HUL rGwEls ' ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave smallest electronic component. form produce less than 5%Total Harmonic Distortion for utility quality power.This allows onfident r Aeration,)t sensitive electronic equipment and micro chip based appliances, O GENERAC TRANSFER SWITCHES.Long life and reliability are synonymous such a,unable spcei HVAC systems. with GENERAC POWER SYSTEMS. One reason for this confidence is that the rFS' rr GENERAC product line includes its awn transfer systems and controls for total system compatibility. PROTOTYPE TESTED NEMA MG1-22 EVALUATION SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY w GENE R AC tiN1*ass �EARrMI �► •`®P *©* Mobil`, F— PROMISE W Link Sl�MEP LP �4RRA -Nu,11,r,11,e US4 usrr,q J-111N,1114 lo,e,pr,t:orfs S ' GENERAC 16/20/22 kW features and benefits F�igine •Generac(OHVI)design Maximizes engine"breathing"for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine run cooler,reducing oil consumption resulting in longer engine life. • Quiet-Test" Greatly reduces sound output and fuel consumption during bi-weekly exercise. •"Spiny-lok'cast iron cylinder walls Rigid construction and added durability provide long engine life. ' -Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. -Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. •t.ow oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. •I ligh temperature shutdown Prevents damage due to overheating. Generator •Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. •Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. -Displaced phase excitation Maximizes motor starting capability. •Automatic voltage regulation Regulates the output voltage to±1%prevents damaging voltage spikes. •UI 2200 listed For your safety. �rr,�s'er Swit.- •e uily automatic Transfers your vital electrical loads to the energized source of power. -Remote mounting Mounts near your existing distribution panel for simple,low-cost installation. -NEMA 3R Can be installed inside or outside for maximum flexibility. Evolution'" Controls •,A ito/Manual/Off illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. •two line LCD multilingual display Provides homeowners easily visible logs of history,maintenance and events up to 50 occurrences. •';eawd raised buttons Smooth,weather-resistant user interface for programming and operations. •eltility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. -Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. •Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. •Engine warm-up Ensures engine is ready to assume the load,setpoint approximately 5 seconds. •Lngine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. •I'rograrnmable exerciser Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. •Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. •electronic governor Maintains constant 60 Hz frequency. Unit -SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph.Hinged key locking roof panel for security. Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. •e nciosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. •Small.compact,attractive Makes for an easy,eye appealing installation,as close as 18"away from a building. tris',ikat,on Syster •t ft ,30�mm)flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. •Direct-to-dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. -integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine,prolonging engine life. GENERAC" 16/20/22 kW specifications _ Ucrler ator G007035-0,G007036-0, G007038-0,G007039-0 G007042-0,G007043-0 _ Model G007037-0(16 kW) (20 kW) (22 kW) Rated Maximum Continuous Power Capacity(LP) 16,000 Watts* 20,000 Watts* 22,000 Watts* Rated Maximum Contuwous Power Capaclly(NG) 16,000 Watts' 18.000 Watts* 19.500 Watts' RatedVollage ` 240 240 240 Rated Niaxii Continuous load Curren 240 Volts(LP/NG) 66.6/66 6 83 3/75 91.6/81-3 Total yarrgEm[c D[slgrlioft „ � :, Less than 5% Less than 5% Less than 5% Main Linty Clreuit Rreaker 70 Amp 100 Amp 100 Amp Phase7iliir .irM; .yku Number of Rotor Poles 2 2 2 Rated AC Frequency ;;;,_.., 60 Hz 60 Hz 60 Hz Power Faclor 1.0 1 0 1.0 Battery Requirement(not included) 12 Volts,Group 26R 540 CCA Minimum or Group 35AGM 650 CCA Minimum Unit Weight(Ib/kg) 409/186 448/203 466/211 DlmeOslons'(L x W x H)irVmm 48 It 25 x 29/1218 x 638 x 732 Sniff Id Apuf in IBrm 112,1 rr ,ith generator operating at normal load** 66 66 67 Sound output in dB(A)at 23 it(7 m)with generator in Quiet Test" low-speed 58 58 58 exercise mode** pis lu dhnr 5 min 5 min 5 into Enoine _.._ ., Type...Engine _ GENERAC OHVI VTWIN GENERAC OHVI VTWIN GENERAC OHVI VTWIN Nw,Ide,cf Ninders 2 2 2 'ri Displacement 999 cc 999 cc 999 cc Cyl adei BIec1 Aluminum w/Cast Iron Sleeve Valve Arrangement Overhead Valve Overhead Valve Overhead Valve gi tion System. Solid-state w/Magneto Solid-state w/Magneto Solid-state w/Magneto Governor System Electronic Electronic Electronic ;f,npnr slot Rah 9 5 1 9.5:1 9.5 1 Starter 12 Vdc 12 Vdc 12 Vdc C,( : ,I dti,i Approx 1 9 ql'8 L Approx 1 9 qV1-8 L Approx 1 9 qi 8 L Operating rpm 3,600 3,600 3,600 Fuel Consumption Natural Gas fl,,/hr(nrl 1172 Load 193(5.47) 205(5.8) 184(5.21) Full Load 312(8.83) 308(8.72) 281 (7.96) Liquid Propane 113/hr(gall[Vhr] 1/2 Load 69(1.9)17.21 81 (2.23)[8.451 78(2.16)[8.16] Full Load 116(3.19)[12 07] 140(3.85)[14.571 134(3.68)(13 941 gate:Fuel pipe must he sized for full load. Required fuel pressure to generator fuel inlet at all load ranges-3.5-7"water column(7-13 mm mercury)for natural gas,10-12"water column(19-22 men mercury,ror LP gas.For Btu content,multiply 113/hr x 2500(LP)or ft3/hr x1000(NG).For Megajoule content,multiply m3/hr x93.15(LP)or m3/hr x 37.26(NG) 2-Line Plain Text Multilingual LCD Display Simple user interface for ease of operation. Mt.de 6�:ror, A,;ro Automatic Start on Utility failure.7 day exerciser Manual Start with starter control,unit stays on.If utility fails,transfer to load takes place. Stops unit.Power is removed.Control and charger still operate. Ready:to RttVI&JillenanceiMessages Standard Ergine n,n nouts muit,a ion Standard Progra(nmable Start delay between 2-1500 seconds Standard(programmable by dealer only) Utility Voltage Loss/Return to Utility Adjustable(Brownout Selling) From 140-171 V/190-216 V Purge Se;Capable Exe:cisgr/Exercise Set Error Warning Standard Rw1/Ala, N,in tenance togs 50 Events Each Engine Start SequenceWw. e Jli Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). Starter cannot re-engage until 5 sec after engine has stopped Smart Battery Charger Standard Charger FauNNi mg AC Warning Standard Low.Battery/Battery Problem Protection and Battery Condition Indication Standard Automat e Vmtage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Overload/Slepper.Overcurrent Protection - Standard Safety Fused/Fuse Problem Protection Standard Automatic L "1iiPress4Hi p(frgtll,gr 2{y(l1Dwn Standard Overcrank/Overspeed(na 72 Hz)/rpm Sense Loss Shutdown Standard High Engine Tem*ture*ut ' Standard ntemal au"'ncorrect Wiring Protection Standard Common External Fault Capabil >w. - 4 0M •. Standard tl U6yraaauie%.rmware Standard Sound le refs ere taker from the pont of me generator Sound levels taken from other sides of rhe generator may be higher depending on installation parameters.Rating definitions-Standby:Applicable for supplying emergency power for the duration lot i rating All ratios in accordance win BS5514.IS03046 and DIN6271). *Maximum wattage and current are subject to and limited by such factors as fuel Btt✓rnegajoule content, I m• d «e•Dula a Nr avenrwe�. abd N 5 available D this c Lir m r.- 9 ap rg ( 9 , ,vn nenf te�nue•amre ermude engine ahwer and condition etc Maximum power decreases about 3.5 percent for each 1,000 feet(304.8 meters)above sea level,and also vall decrease about 1 percent for each 6 T(10"F)above 16 T(60 rt). GENERAC' 16/20/22 kW switch options Limited Circuit Switch Model G007036-0(16 kW) • 16 circuits. No.of Poles'; Current Rating(Amps) 100 • Electrically operated,mechanically-held contacts for fast,positive connections. Voltage Rating(VACjjj 120/240;10 • Rated for all classes of load, 100%equipment rated,both inductive and resistive. Utility voltage Monitor(Fixed)* -Pick-up 80% • 2 pole 250 VAC contactors -Dropout 65% Return to Utility' approx.15 sec. • 30 millisecond transfer time. Exercise bi-weekly for 12 minutes' Standard UL Listed Standard • Dual Coe design. Total of Pre-wired Circuits 16 • Rated for both copper and aluminum conductors. No.15 A 120 V 5 • Mair:contacts are silver plated or silver alloy to resist welding and sticking. No.20 A 120 V 5 P Y 9 9 No.20 A 240 V 1 • NEMA 3R aluminum outdoor enclosure allows for indoor or outdoor mounting No.30 A 240 V - No.40 A 240 V 1 flexibility. No.50 A 240 V 1 • Mul1 listed for use with 1"standard,tandem,GFCI and AFCI breakers from Tandem Breaker Capability Siemens,Murray,Eaton and Square D for the most flexible and cost effective install. Circuit Breaker Protected Available RMS Symmetrical Fault Current @ 250 Volts 10,000 'Function of Evolution Controller Exercise can be set to weekly or monthly Dimensions 200 Amps 120/240,1e Open Transition Service Rated Height _Width HI H2 y_--W1 W2 - Depth --.----- in 27 24 30.0 11.4 1 13.5 7.09 mm 692.0 762.4 -289_0 -343_0 180.0 Wire Ranges i Conductor Lug Neutral Lug Ground Lug 2,'0-#14 2/0-#14 2/0-#14 Service Rated Smart Switch Features G007037-0(16 kW)/G007039-0(20 kW)/ • Includes Digital Power Management Technology standard(DPM). Model 0007043-0(22 kW) • Intelligently manages up to four air conditioner loads with no No.of Poles 2 additional hardware. Current Rating(Amps) 200 Voltage Rating(VAC).„ ': 120/240,10 • Up to four more large(240 VAC)loads can be managed when used in Utility Voltage Monitor(Fixed)" conjunction with Smart Management Modules(SMMs). -Pick-up 80% • ::lectrcally operated,inechan tally-held contacts for fast,clean 0ropour 65% ronrnt,ctions Return toUti%* approx.13 sec. • !iatec for ail classes of load, 100%equipment rated,both inductive and Exercise weekly for 12 minutes` Standard UL Listed Standard resistive. NEMA/UL 3R Enclosure Type • Up to tour more large(120/240 VAC)loads can be managed when used in Withstand Rating(Amps) 22,000 conjunction with 50 amp Power Management Modules(PMM"). Lug Range 250 MCM-#6 • 2 pole 250 VAC contactors. `Function of Evolution Controller • Service equipment rated,dual coil design. • Rated for both aluminum and copper conductors. --" ---- - • NI MA 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • ".^air,ontacts aie sdv!;r platen or silver alloy to resist welding and s�ick�iy i Dimensions 200 Amps 120/240,to Open Transition Service Rated Height_ Width h H1 H2 W1 W2 Depth in 27.24 30.0 11.4 13.5 7.09 --- mm 692.0 762.4 289.0 343.0 180.0 L DEPTH U W2—� GENERACa 16/20/22 kW available accessories Model# Product _ Description I Generac's Mobile Link allows you to check the status of your generator from anywhere that you have G006463-3 Mobile Link" access to an Internet connection from a PC or any smart device. You will even be notified via e-mail or text message when a change in the generator's status occurs. Available in the U.S.only. G005819 0 26R Wet Cell Battery Every standby generator requires a battery to start the system.Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product(excluding PowerPact@). r G007101-0 Battery Pad Warmer The pad warmer rests under the battery.Recommended for use if the temperature regularly falls below 0°F.(Not necessary for use with AGM-style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if the temperature regularly falls below 0°F. ('77103-0 Breather Warmer The breather warmer is for use in extreme cold weather applications. For use with Evolution L controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch Contact The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical Kit load you may not need.Not compatible with 50 amp pre-wired switches. Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air cooled generators.This offers G007027-0-Bisque Standard on 22 kW) a sleek,contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. II the generator enclosure is scratched or damaged,it is important to touch-up the paint to protect G005703-0-Bisque Paint Kit from future corrosion.The paint kit includes the necessary paint to property maintain or touch-up a generator enclosure. G006485-0- 16,20& Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete 22 kW routine maintenance on a Generac automatic standby generator. Smart Management Module Smart Management Modules are used in conjunction with the Automatic Transfer Switch to G006873-0 increase its power management capabilities.It provides additional power management flexibility (50 Amps) not found in any other power management system. dimensions & UPCs Dimensions shown are approximate. Refer to installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. —1218- 63 fimn -- — I".0 Nr 125.1 int Model UPC G007035-0 696471070354 G007036-0 696471070361 G007037-0 696471070378 G007038-0 696471070385 ji s , h G007039-0 696471070392 I� G007040-0 696471070408 i Oil / -- - �, G007042-0 696471070422 G007043-0 696471070439 6.. _ _ ,32 2 - -- 125.5 int 1".5 Me LFF SIDE VIEW FRONT VIEW GENE RAC Generac Power Systems,Inc. • S45 W29290 HWY.59, Waukesha,WI 53189 • generac.com 02016 Generac Power Systems,Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 10000000194-B 05/18/16