HomeMy WebLinkAboutProdudct Approval - underlayment i.Floride Building Code Online1e ® yPage 1 of 2
-7 -
V I
_ x
Business & Professional RegWatiot
SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats®Facts Publications FBC Staff eCtS Site Map links Search
'Busines �`
Professional Product Approval
USER:Public User
RAr1:.�rt!i1i�
Prod,wt Annrnual Mnn„>Prnd,rt nr Annlirat nn Caarrh>Annliration I ict>Application Detail
FL# FL5259-R24
Application Type Revision + � #
Code Version 2014
Application Status Approved ? J�
*Approved by DBPR.Approvals by DBPR s 4,��'wljewed a&no ratified by
the POC and/or the Commission if necessary. e co ,v
Comments
Archived
Product Manufacturer POLYGLASS USA
Address/Phone/Email 150 Lyon Drive
Fernley, NV 89408
(570) 384-1230 Ext 242
jakins@polyglass.com
Authorized Signature James Akins
jakins@polyglass.com
Technical Representative Steve Wadding
Address/Phone/Email 150 Lyon Drive
Fernley, NV 98408
(602) 363-7139
stevew@polyglass.com
Quality Assurance Representative James Akins
Address/Phone/Email 555 Oakridge Road
Humboldt Industrial Pkwy
Hazleton,PA 18201
(800)894-4563
jakins@polyglass.com
Category Roofing
Subcategory Undedayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 07/01/2017
Validated By John W.Knezevich, PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL5259 R24 COI 2015 01 COI Nieminen.odf
Referenced Standard and Year(of Standard) Stand, Year
ASTM D1970 2009
ASTM D226 2006
ASTM D6164 2005
httpJ/www.floridabuilding.org/pr/pr_app_d6.aspx?param=wGP-VXQwtDgvbSgAaZp3Crk2vS%2fegOlipH82Cu7FMfVnJrJdOHoR9%2fA%3d... April 13,2016
Florida Building Code Online Page 2 of 2
ASTM D6222 2008
ASTM G154 2006
ASTM G155 2005
' FM 4474 2004
FRSA/TRI April 2012 2012
TAS 103 1995
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 07/22/2015
Date Validated 08/07/2015
Date Pending FBC Approval 08/15/2015
Date Approved 10/16/2015
Summary of Products
FL# Model,Number or Name Description
5259.1 Polyglass Roof Roofing underlayments
Underlayments
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL5259 R24 II 2015 07 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
Approved for use outside HVHZ:Yes R24.odf
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes
Other: 1.)The design pressure in this Evaluation Reports
application relates to one particular FL5259 R24 AE 2015 07 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
underlayment system (over concrete deck) for P 2,4.Odf
use under foam-on tile systems(where the Created by Independent Third Party: Yes
underlayment forms part of the load-path).
Refer to ER Section 5.6.4 for other systems,
other deck types and associated maximum
design pressures. 2.) Refer to ER Section 5 for
other limits of use.
0
L Contact I.Is::1440 North Mnnrn St-1 TallahasceP FI "112709 Phoney R50-4117-t R24
The State of Florida is an AA/EEO employer.Cnpyr oht 2nn7-201-4 State of Florida-::Pr vary-,Statement::ArrP—Hity Statement::Reft and Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section
155.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.if you do not wish to supply a personal
address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,
please click here.
Product Approval Accepts:
111 ®Wfea. C
securitv,ii 1 ial
http://www.floridabuilding.org/pr/pr_app_dfl.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2vS%2feg01ipH82Cu7FMfVnJrJdOHoR9%2fA%3d... April 13,2016
EXTERIOR RESEARCH &DESIGN, LLC.
Certificate of Authorization#9503
353 CHRISTIAN STREET, UNIT#13
TRINITY ERD OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
EVALUATION REPORT
Polyglass USA, Inc. Evaluation Report P12060.02.09-R20
ISO Lyon Drive FL5259-R24
Fernley, NV 98408 Date of Issuance:02/24/2009
Revision 20:07/22/2015
SCOPE:
This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted
herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 12.
Prepared by:
" The facsimile seal appearing was authorized by Robert Nieminen,
a_
P.E.on 07/22/2015. This does not serve as an electronically
Robert J.M. Nieminen P.E. �'O�' R:^Rt lir—:':' signed document. Signed,sealed hardcopies have been
• '••f'cO�a`�;` , transmitted to the Product Approval Administrator and to the
Florida Registration No. 59166, Florida DCA ANE1983 �.,..,,,,,,
named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY ERS
4.2.7 Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet (FR) are polyester
reinforced,APP modified bitumen cap sheets; meet ASTM D6222.
4.2.8 Polystick Dual Pro`" is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass
reinforced,with a polyester fabric surface; meets ASTM D1970.
4.2.9 Polystick Tile Pro'" is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass
reinforced,with a polyester fabric surface; meets ASTM D1970 and TAS 103.
4.3 Mechanically Fastened and/or Bonded Underlayments:
4.3.1 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced, SBS modified bitumen cap sheets; meet ASTM D6164.
4.3.2 Polyflex G and Polyflex G FR are polyester reinforced,APP modified bitumen cap sheets; meet ASTM D6222.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation
combined with supporting data for the prepared roof covering.
5.S Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Underiayment Asphalt Shingles Nail-On Tile Foam-On Tile Metal Wood Shakes& Slate
_ Shingles
Yes Yes
Elastobase Yes (base la er m 2- Yes Yes Yes
Y Ph (base layer in 2-ply
system) system)
Yes Yes
Elastobase P Yes (base layer in 2-ply (base layer in 2-ply Yes Yes Yes
-
V
_ system) system)
Polystick MTS Yes Yes No Yes Yes Yes
Polystick MTS PLUS Yes Yes No Yes Yes Yes
Polystick IR-Xe Yes No No No Yes Yes
Polystick TU P Yes Yes Yes No Yes Yes
See 5.5.1
Polystick TU Plus Yes Yes Yes Yes Yes Yes
See 5.5.1
Polystick TU Max No Yes Yes Yes No No
See 5.5.1
Polystick Dual Pro I Yes Yes No Yes Yes Yes
Polystick Tile Pro Yes Yes Yes Yes Yes Yes
See 5.5.1
Elastoflex S6 G Yes Yes Yes No Yes Yes
See 5.5.1
Elastoflex S6 G FR Yes Yes No No Yes Yes
Polyflex G Yes Yes Yes No Yes Yes
See 5.5.1
Polyflex G FR Yes Yes No No Yes Yes
Polyflex SAP or SAP FR Yes Yes Yes No Yes Yes
See 5.51
Mule-Hide SA-APP Cap Sheet Yes Yes Yes No Yes Yes
or SA-APP Ca -T-
p Sheet(FR) See 5.5.1
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R20
Certificate of Authorization#9503 FL5259-R24
Revision 20:07/22/2015
Page 4 of 12
L
TRINITY ERD
5.5.1 "Foam-On Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion / long term aging
data from an accredited testing laboratory is provided.
✓ 31VI"" 2-Component Roof Tile Adhesive AH-160 (FL6332): Polystick TU P, Polystick TU Plus, Polystick TU Max,
Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP
Cap Sheet(FR)or Tile Pro.
✓ 3M'"' Foam Roof Tile Adhesive RTA-1 (FL6276): Polystick TU P, Polystick TU Plus, Polystick TU Max, Elastoflex S6
G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet (FR)
or Tile Pro
✓ Dow TileBond (FL717): Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro
✓ Convenience Products' Touch 'n Seal StormBond Roof Tile Adhesive (FL14506): Polystick TU Plus, Polystick TU
Max
5.6 Allowable Substrates:
5.6.1 Direct-Bond to Deck:
Polystick (all variations), Dual Pro,Tile Pro, Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet
(FR)self-adhered to:
r New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing
plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels
(designed and installed to meet wind loads for project).
Note: Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or
OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes.
Flastoflex S6 G or S6 G FR in hot asphalt to:
ASTM D41 primed structural concrete.
Polyflex G or G FR torch-applied to:
%- ASTM D41 primed structural concrete.
5.6.2 Bond-to-Insulation:
Polystick (all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self-adhered
to:
r ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck
DuraGuard; Dens Deck Prime; or SECUROCK Gypsum-Fiber Roof Board.
Elastoflex S6 G or S6 G FR in hot asphalt to:
.- Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board.
` Polyflex G or G FR torch-applied to:
.- ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile
systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FBC Section 1504.3.1.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R20
Certificate o/Authorization#9503 FL5259-1124
Revision 20:07/22/2015
Page 5 of 12
TRINITY ERD
5.6.3 Bond to Mechanically Attached Base Laver:
Polystick (all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or
Tile Pro self-adhered to:
i' ASTM D226,Type I or II felt; Elastobase; Elastobase P or Mule-Hide Nail Base.
Elastoflex S6 G or S6 G FR in hot asphalt to:
ASTM D226,Type I or 11 felt; Elastobase; Elastobase P or Mule-Hide Nail Base.
Polyflex G or G FR torch-applied to:
Elastobase; Elastobase P or Mule-Hide Nail Base.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam-on the systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12), Appendix A,Table 1, or as listed in Section 5.6.4 herein, or as tested in
accordance with FBC Section 1504.3.1.
Applications: FRSA RI April 2012 04-12) does not
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile pp /T P (
address wind uplift resistance of all underlayment systems beneath foam-on tile systems, where the underlayment
forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012 (04-12) and are used in foam-on tile applications. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-
12),Appendix A,Table 1A or FBC 1609 for determination of design wind loads.
5.6.4.1 Maximum Design Pressure=-90 psf.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional)PG100 or ASTM D41
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.2 Maximum Design Pressure=-135 psf.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional)PG100 or ASTM D41
Joints: Min.4-inch wide strips of Elastoflex SA-V over all plywood joints.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.3 Maximum Design Pressure=-315 psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: PG 100 or ASTM D41
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max,Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap
Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.4 Maximum Design Pressure=-622.5 psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: PG100 or ASTM D41
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.5 Maximum Design Pressure=-30.0 psf*.
Deck: Min.15/32-inch OSB to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R20
Certificate of Authorization#9503 FL5259-R24
Revision 20:07/22/2015
Page 6 of 12
TRINITY ERD
5.6.4.6 Maximum Design Pressure=-37.5 psf*.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.7 Maximum Design Pressure=-37.5 psf*.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: One(1)or two(2)layers ASTM D226,Type It felt
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt.
5.6.4.8 Maximum Design Pressure=-4S psf*.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: One(1)layer ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c.at the 2-inch wide side laps and 4-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex S6 G,applied in full mopping of hot asphalt.
5.6.4.9 Maximum Design Pressure=-45 psf*.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Two(2)layers ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 9-inch o.c.at the 2-inch wide side laps and 9-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus, Polystick TU Max, Polyflex SAP,Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex 56 G,applied in full mopping of hot asphalt.
5.6.4.10 Maximum Design Pressure=-45 psf.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 2-inch wide side laps and 18-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.11 Maximum Design Pressure=-52.5 psf.
` Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.12 Maximum Design Pressure=-SIS psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R20
Certificate of Authorization#9503 FL5259-R24
Revision 20:07/22/2015
Page 7 of 12
TRINIn ERD
5.6.4.13 Maximum Design Pressure=-52.5 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHI.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.14 Maximum Design Pressure=-60 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.15 Maximum Design Pressure=-60 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.16 Maximum Design Pressure=-90 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MARX Cap Fasteners
Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.17 Maximum Design Pressure=-90 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.18 Maximum Design Pressure=-90 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt.
5.6.4.19 Maximum Design Pressure=-97.5 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c.at the 4-inch wide side laps and 4-inch o.c.at four(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.20 Maximum Design Pressure=-105 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R20
Certificate of Authorization aa9503 F152S9-R24
Revision 20:07/22/2015
Page 8 of 12
i
TRINITY ERS
5.6.4.21 Maximum Design Pressure=-112.5 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer at all tin-caps
Base Ply: Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.22 Maximum Design Pressure= -120 psf.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with CMG 3" Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.23 Maximum Design Pressure=-120 psf.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt.
5.6.4.24 All other direct-deck, adhered Polyglass underlayment systems beneath foam-on tile systems carry a Maximum
Design Pressure of-45 psf.
5.6.4.25 For mechanically attached base sheet in a 2-ply system,the maximum design pressure for the selected assembly shall
meet or exceed the Zone 1 design pressure determined in accordance with FRSA/TRI April 2012 (04-12), Appendix A,
Table 1A or FBC 1609. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional
to resist the elevated pressure criteria. Commonly used methods are RAS 117, FM LPDS 1-29 and ANSI/SPRI WD1.
Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone
2/3 enhancements.
5.7 Exposure Limitations:
Elastobase or Elastobase P shall not be left exposed for longer than 30-days after installation.
Polystick IR-Xe shall not be left exposed for longer than 90-days after installation.
Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Dual Pro or Tile Pro shall not be left exposed for longer than 180-
days after installation.
Polyflex SAP or SAP FR, or Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive-set tile, in which case the maximum exposure is 30
days.
Elastoflex S6 G or S6 G FR or Polyflex G or G FR does not have an exposure limitation, unless the prepared roof
covering is to be adhesive-set the (Elastoflex 56 G or Polyflex G only), in which case the maximum exposure is 180
days.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-RZO
Certificate of Authorization#9503 FL5259-R24
Revision 20:07/22/2015
Page 9 of 12
TRINITY ERS
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application,and prime the substrate(if applicable).
6.3 Elastobase Elastobase P or Mule-Hide Nail Base:
6.3.1 Shall be installed in compliance with the codified requirements for ASTM D226,Type II underlayment in FBC Sections
1507 for the type of prepared roof covering to be installed.
6.3.2 Non-Tile Applications:
Reference is made to the current edition of the NRCA Steep-slope Roofing Manual and ARMA recommendations for
installing shingle underlayments and flashings
Elastobase, Elastobase P or Mule-Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP or SAP FR,
Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or Tile Pro, self-adhered, Elastoflex S6 G or S6 G FR in
hot asphalt or Polyflex G or G FR,torch applied.
6.3.3 Tile Applications:
Reference is made to FRSA/TRI April 2012(04-12) Installation Manual and Table 1 herein, using the instructions noted
above as a guideline.
6.4 Polystick MTS MTS PLUS IR-Xe TU P TU Plus,TU Max-Polyflex SAP or SAP FR Mule-Hide SA-APP Cap Sheet or SA-
APP Cap Sheet(FR) Dual Pro or Tile Pro:
6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Sections 1507
for the type of prepared roof covering to be installed.
6.4.2 Direct-to-Deck with Mechanically Fastened Roof Covers:
All self-adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule-Hide SA-APP Cap
Sheet or SA-APP Cap Sheet (FR) should be back-nailed in selvage edge seam in accordance with Polyglass/ Mule-Hide
Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring-shank type with a minimum 1-inch diameter
metal disk or Simplex-type metal cap nail,at a minimum rate of 12" o.c. Polystick TU Plus should be back-nailed using
the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane. The
head lap membrane is to cover the area being back-nailed
All seal-lap seams (selvage laps) must be
firmly rolled with a minimum 28 Ib. hand ".
roller to ensure full contact and adhesion.
For Dual Pro and Tile Pro, align the edge of
the top sheet to the end of the glue pattern
(the sheet will overlap the fabric).
y
View of Ovelap Seam of Dual Pro and Tile Pro
All over-fabric and over-granule end-laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified
Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap.
Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys,
or exposed roof to wall details
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R20
FL5259-R24
Certificate of Authorization#9503
Revision 20:07/22/2015
Page 10 of 12
TRINITY ERS
Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or
Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be
installed in a water shedding manner.
All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 40-Ib weighted-roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches, laps(min.28 Ib roller)or small areas of the
roof that are not accessible to a large roller or broom.
6.4.3 Tile Applications(not allowed for Polystick IR-Xe):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted
above as a guideline.
For mechanically fastened tile roofing over 2-ply system, consisting of base sheet and self-adhering top sheet(s), base
sheet fastening shall be not less than FRSA/TRI April 2012 (04-12),Table 1.
For adhesive-set tile applications, refer to Section 5.6.4 herein.
For nail-on tile systems over Polystick MTS, battens are required for loading/staging of the tile.
For nail-on tile systems over Polystick MTS PLUS:
Battens are required for loading/staging of lugged tile regardless of slope.
Battens are required for loading/staging of flat tile at slopes in excess of 5:12.
6.4.4 Two(2) Ply Underlayment Systems:
Polystick MTS or MTS PLUS followed by Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, TilePro or Polyflex SAP is
allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the
top-layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired.
Polystick MTS PLUS followed by Polystick TU P, TU Plus, TU Max, TilePro or Polyflex SAP is allowable for use under
foam-on tile systems. Limits of use are those associated with the top-layer material. This is not a requirement, but is
allowable if a 2-ply underlayment system is desired.
6_5 Elastoflex S6 G or S6 G FR:
6.5.1 Elastoflex 56 G or S6 G FR shall be installed in compliance with current Polyglass published installation requirements.
For use in tile applications, reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein.
6.S.2 Elastoflex S6 G or S6 G FR shall be fully asphalt-applied to the substrates noted in Section 5.6. Side laps shall be
minimum 3-inch and end-laps minimum 6-inch wide, off-set minimum 3 feet from course to course. Side and end
laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch
beyond the lap edge.
6_6 Polyflex G or G FR:
6.6.1 Polyflex G or G FR shall be installed in compliance with current Polyglass published installation requirements. For use
in tile applications, reference is made FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein.
6.6.2 Polyflex G or G FR shall be fully torch-applied to the substrates noted in Section 5.6. Side laps shall be minimum 3-
inch and end-laps minimum 6-inch wide, off-set minimum 3 feet from course to course. Side and end laps shall be
fully heat-welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge.
6_7 Tile Staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to
Polyglass published requirements for tile staging.
6.7.2 Battens and/or Counter-battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used
on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or sail-
boards,to prevent tile sliding and/or damage to the underlayment during the loading process.
6.7.3 For nail-on tile systems over Polystick MTS, battens are required for loading/staging of the tile.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R20
Certificate of Authorization#9503 FL5259-RZ4
Revision 20:07/22/2015
Page 11 of 12
f
TRINITY ERD
6.7.4 For nail-on tile systems over Polystick MTS PLUS:
i Battens are required for loading/staging of lugged the regardless of slope.
P, Battens are required for loading/staging of flat tile at slopes in excess of 5:12.
6.7.5 The minimum cure time after installation of self-adhering membranes and before loading of roofing tiles is forty-eight
(48) hours.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
H. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. Rule 61G20-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
UL, LLC—QUA9625;(314)578-3406; k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
I
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R20
certificate of Authorization#9503 FL5259-R24
Revision 20:07/22/2015
Page 12 of 12