HomeMy WebLinkAboutProduct Approval (3) Florida Building Code Online Page 1 of 2
r-11s 77---�-
r ,
� ��-}--
I
f -BCIS Home Log In i User Registration f Hot Topics : Submit Surcharge Stats&Facts Publications PBC Staff BCIS Site Map Links i Search
EE' i Product Approval
USER:Public Per l'.'-.��t 11 i.• 1 �•1 I� i 1, ,r�
Product Approval Menu>Product or Aoolication Search>Application List>Application Detail .1 ,•� •$ �� _`.�'
A
FL# FL16027-R1
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived ❑
Product Manufacturer Tri-Built Materials Group, LLC
Address/Phone/Email PO Box 70
Rutherford,NJ 07070
(800) 516-1485
david.ruiz@tribuiltmg.com
Authorized Signature David Ruiz
david.ruiz@tribuiltmg.com
Technical Representative C Richard Schurman
Address/Phone/Email 9050 Louisiana Street
Merrillville,IN 46410
rich.schurman@alliedbuilding.com
Quality Assurance Representative C Richard Schurman
Address/Phone/Email 9050 Louisiana Street
Merrillville,IN 46410
rich.schurman@alliedbuilding.com
Category Roofing
Subcategory Modified Bitumen Roof System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
© Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity tIL LLC
Quality Assurance Contract Expiration Date 03/31/2019
Validated By John W. Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL16027 R1 COI 2015 01 COI Nieminen.Ddf
Referenced Standard and Year (of Standard) Standard Year
ASTM D6163 2000
ASTM D6164 2005
ASTM D6222 2008
FM 4470 1992
FM 4474 2004
Equivalence of Product Standards
Certified By
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtFPmdYiNDWrx... 3/3/2017
Florida Building Code Online Page 2 of 2
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 03/23/2015
Date Validated 03/29/2015
Date Pending FBC Approval 03/31/2015
Date Approved 06/22/2015
Summary of Products
FL# Model, Number or Name Description
16027.1 TRI-BUILT Modified Bitumen Roof SBS and APP modified bitumen roof systems
Systems
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16027 R1 II 2015 03 FINAL Al ER TRI-
Approved for use outside HVHZ: Yes BUILT MODBIT FL16027-111.pdf
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes
Other: 1.)The DP noted in this application refers to one Evaluation Reports
system. Refer to ER Appendix for all systems and max. FL16027 R1 AE 2015 03 FINAL ER TRI-
design pressures. 2.)Refer to ER Section 5 for Limits of Use. BUILT MODBIT FL16027-Rl.odf
Created by Independent Third Party: Yes
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
............._.._.__......................._............................
Credit Gare!
Safe
Cm=
http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtFPmdYiNDWrx... 3/3/2017
-7-
TRINIWI ERD
APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
Table Deck Application Type Description Page
IA-1 Wood New or Reroof(Tear-off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 4
1A-2 Wood New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 5-
1B Wood New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 5
1C Wood New,Reroof(Tear-off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 6
1D Wood New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 6
1E-1 Wood New or Reroof(Tear-Off) E Non-insulated,Mech.Attached Base Sheet,Bonded Roof Cover 7
IE-2 Wood New,Reroof(Tear-Off)or Recover E Non-insulated,Mech.Attached Base Sheet,Bonded Roof Cover 8
IF Wood New or Reroof(Tear-Off) F Non-insulated,Bonded Roof Cover 8
2A Steel or Conc. New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 9
2B Steel or Conc. New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 10
2C Steel or Conc. New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 11
3A-1 Concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 12-14
3A-2 Concrete New or Reroof(Tear-Off) A-1 Bonded Temporary Roof,Bonded Insulation,Bonded Roof Cover 15
3B Concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 15
4A LWIC New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 16-17
4B LWIC New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 17
4C LWIC New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 18-20
SA CWF New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 21
SB CWF New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 22
5C CWF New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 22
5D CWF New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 23
5E CWF New,Reroof(Tear-Off)or Recover E Non-insulated,Mech.Attached Base Sheet,Bonded Roof Cover 23
6A Gypsum New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 24
6B Gypsum New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 25
6C Gypsum New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 25
6D Gypsum New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 25
7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 26-27
7B Various Recover F Non-insulated,Bonded Base Sheet,Bonded Roof Cover 27
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the
roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Insulation/base sheet fasteners shall be of sufficient length for the following deck engagement:
>Wood: Minimum 0.75-inch penetration.
>Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.
> Concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions.
3. Unless otherwise noted,insulation may be any one layer or combination of polyisocya n u rate,polystyrene,wood fiberboard,perlite,Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or SECUROCK
Glass-Mat Roof Board that meets the CIA requirements of F.A.C.Rule 61G20-3 and is documented as meeting FBC 1505.1 and,for foam plastic,FBC 2603.4.1 or 2603.6,when installed with the roof cover.
Exterior Research and Design,LLC.d/b/a Trinity[ERD Evaluation Report A42970.10.12-RI for FL16027-R1
Certificate of Authorization#9503 Revision 1:03/23/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 1 of 27
TRINITY I ERD
4. Minimum 200 psi,minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D(mechanically attached base sheet,bonded roof cover),whereby the base
sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and
structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
S. Unless otherwise noted,insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instructions.
➢ HA(HA): Full coverage at 25-30 lbs/square.
➢ Dow Insta-Stik Roofing Adhesive(D-IS): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c.
➢ Millennium One Step Foamable Adhesive(M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c.
➢OMG OlyBond 500(OB500): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c.(PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced.
➢OlyBond Classic(OB Classic): Full coverage at 1 gal/square.
➢3M CR-20: Continuous 2.5-3.5-inch wide ribbons,12-inch o.c.
➢ Note: When multiple layers(s)of insulation and/or coverboard are installed in ribbon-applied adhesive,adhesive ribbons shall be staggered from layer-to-layer a distance of one-half the ribbon spacing.
➢Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
6. Unless otherwise noted,all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocya n u rate at the following thickness limitations may be substituted with the following Maximum
Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then
the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table:
➢ Millennium One Step Foamable Adhesive(M-OSFA): MDP -157.5 psf (Min.0.5-inch thick)
➢OMG OlyBond 500(OB500): MDP -45.0 psf (Min.0.5-inch thick Multi-Max FA-3)
➢ OMG OlyBond 500(OB500): MDP -187.5 psf (Min.0.5-inch thick ISO 95+GL)
➢OMG OlyBond 500(OB500): MDP -315.0 psf (Min.0.5-inch thick ENRGY 3)
➢ OMG OlyBond 500(06500): MDP -487.5 psf (Min.0.5-inch thick ACFoam II)
➢ 3M CR-20: MDP -117.5 psf (Min.1.0-inch thick)
7. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft.
8. For mechanically attached components or partially bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16,and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29.
Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.1.5.1(a)of FM LPDS 1-29 for Zone 2/3 enhancements.
9. For fully bonded assemblies,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16,and no rational analysis is permitted.
10. For mechanically attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1.
11. For existing substrates in a bonded recover installation,the existing roof system shall be examined for compatibility and bond performance with the selected adhesive,and the existing roof system shall be capable of
resisting project design pressures on its own merit to the satisfaction of the AHJ,as documented through field uplift testing in accordance with ASTM E907,FM LPDS 1-52,ANSI/SPRI IA-1 or TAS 124.
12. For Recover Applications using System Type D,the insulation is optional;however,the existing roof system shall be suitable for a recover application.
13. LWIC shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced,refer to current LWIC Product Approval for specific deck
construction and limitations. For systems where specific LWIC is not referenced,the minimum design mix shall be 300 psi. In all cases,the minimum top-coat thickness is 2-inches. For LWIC over structural concrete,
reference is made to FBC Section 1917.4.1,Point 1.
-
Exterior Research and Design,LLC.d/b/a Trinity ERDz i rc Evaluation Report A42970.10.12-R1 for FL16027-R1
Certificate of Authorization#9503 cT c '.z Revision 1:03/23/2015
Prepared by: Robert Nieminen,PE-59166 p cl Appendix 1,Page 2 of 27
.t
'\S
TRINITY I ERD
14. Unless otherwise noted,refer to the following references for bonded base,ply or cap sheet applications.
TABLE 1:TRI-BUILT ROOF COVERS
Reference Layer Material Application
BP-AA Base FBC Approved ASTM D4601,Type II
HA at 20-40 lbs/square
(Base and Ply sheets,Asphalt-Applied) Ply FBC Approved ASTM D2178,Type IV or VI
SBS-AA Cap TriBuilt SBS Granular HA at 20-40 lbs/square
(SBS,Asphalt-Applied)
SBS-TA
(SBS,Torch-Applied) Cap TriBuilt SBS Granular Torch-Applied
SBS-SA Base TriBuilt SA SBS Base
Self-Adhering
(SBS,Self-Adhering) Cap TriBuilt SA SBS Cap
APP-TA Base or Ply TriBuilt APP Smooth
Torch-Applied
(APP,Torch-Applied) Cap TriBuilt APP Smooth,TriBuilt APP Granular
APP-SA
(APP,Self-Adhering) —
Cap TriBuilt SA APP Cap Self-Adhering
15. The following represent priming requirements for gypsum-based coverboards:
➢ Dens Deck and Dens Deck Prime shall be field-primed with ASTM D41 primer prior to self-adhering.or torch-applied membrane application.'No priming is required for hot-asphalt membrane applications.
SECUROCK Gypsum-Fiber Roof Board does not require field priming for any membrane application.
16. "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design,LLC.d/b/a Trinity)ERD Evaluation Report A42970.10.12-R1 for FL16027-R1
Certificate of Authorization#9503 Revision 1:03/23/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 3 of 27
TRINIIYIERD
TABLE 1A-1:WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF)
SYSTEM TYPE A-2:MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER
System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover MDP
No. (See Note 1) Type Fasteners Attach Type Attach Type Attach Base Ply Cap (psf)
Min.0.25-inch Dens
Polyglass G2 Base, 8-inch o.c.in 4- Deck,Dens Deck Prime,
Min.19/32- CertainTeed Glasbase, 32 ga.,1-5/8- inch lap and 8- (Optional)FBC SECUROCK Gypsum-
inch diameter inch o.c.in Approved, Fiber Roof Board,Min. SBS-AA,
W-1 inch plywood Firestone at max.24- Perma-Ply 28 28 Base,,Tamko Bp-AA tin caps with 11 three,equally ASTM C1289, HA 0.75-inch FescoBoard HA BP-AA (Optional) SBS-TA, -60.0
�
inch spans Glass Base or ga.annular ring spaced, type II polyiso- (homogeneous)or min. APP-TA
GAFG LAS#75 shank nails staggered cyanurate 0.5-inch Structodek
center rows High Density Fiberboard
Roof Insulation
Polyglass G2 Base, 8-inch o.c.in 4-
32 ga.,1-5/8- inch lap and 8- (Optional)FBC (Optional) SBS-SA,
Min.19/32- CertainTeed Glasbase, Min.0.25-inch Dens
inch diameter inch o.c.in Approved, One or
inch plywood Firestone MB Base,JM Deck,Dens Deck Prime, APP-SA,
W-2 at max.24- Perma-Ply 28,Tamko tin caps with 11 three,equally ASTM C1289, HA SECUROCK Gypsum- HA SBS-SA more SBS- SBS-TA or -60.0
inch spans Glass Base or ga.annular ring spaced, type II polyiso- Fiber Roof Board SA or APP TA
GAFGLAS#75 shank nails staggered cyanurate APP-TA
center rows
6-inch o.c.in 4- Min.2-inch D-IS,OB500,
32 ga.,1-5/8- inch lap and 6-
Min.19/32- ACFoam II,III, CR-20 or M- Min.0.25-inch Dens D-IS,
Polyglass Elastobase inch diameter inch o.c.in SBS-AA,
W-3 inch plywood or Polyglass tin caps with 12 four,equally H-Shield,H- OSFA,atop Deck,Dens Deck Prime OB500, BP AA (Optional) SBS-TA, -60.0
at max.24- Shield CG, fastener or SECUROCK Gypsum- CR-20 or BP-AA
inch spans Elastobase Poly ga.annular ring spaced, Multi-Max FA3 rows,7-inch Fiber Roof Board M-OSFA APP TA
shank nails staggered
center rows or ENRGY-3 oc
6-inch o.c.in 4- Min.2-inch D-IS,08500,
32 ga.,1-5/8- inch lap and 6- (Optional)
Min.19/32- ACFoam II,III, CR-20 or M- D-IS, SBS-SA,
Polyglass Elastobase inch diameter inch o.c.in One or
inch plywood H-Shield,H- OSFA,atop (Optional)Additional OB500, APP-SA,
W-4 or Polyglass tin caps with 12 four,equally SBS-SA more SBS- -60.0
at max.24- Elastobase Poly Shield CG, "fastener layers of base insulation CR-20 or SBS-TA or
inch spans y ga.annular ring spaced, SA or
shank nails staggered Multi-Max FA3 rows,7-inch M-OSFA APP TA
center rows APP TA
or ENRGY-3 oc
Exterior Research and Design,I.I.C.d/b/a Trinity)ERD Evaluation Report A42970.10.12-111 for FL16027-R1
Certificate of Authorization#9503 Revision 1:03/23/2015 -�
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 4 of 27
fJ
TRINITY I ERD
TABLE 1A-2:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER
SYSTEM TYPE A-2:MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER
System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover MDP
No. (See Note 1) Type Fasteners Attach Type Attach Type Attach Base Ply Cap (Psf)
12-inch o.c.in 4-
Min.0.25-inch Dens Deck,
Min.19/32-
Polyglass OMG Flat inch lap and 12-
(Optional)FBC Dens Deck Prime,SECUROCK
Elastobase or Approved, Gypsum-Fiber Roof Board,
inch plywood Bottom Plates inch o.c.in two, (Optional) SBS-AA,SBS-
W-5 at max.24- Polyglass (square)with equally spaced, ASTM C1289, HA Min.0.75-inch FescoBoard HA BP-AA BP-AA TA,APP-TA -60.0
Elastobase type II polyiso- (homogeneous)or min.0.5-
inch spans Poly Roofgrip#12 staggered center cyanurate inch Structodek High Density
rows Fiberboard Roof Insulation
12-inch o.c.in 4-
Polyglass (Optional)FBC (Optional)
Min.19/32- OMG Flat inch lap and 12-
inch plywood Bottom Plates inch o.c.in tw
Elastobase or Approved, Min.0.25-inch Dens Deck, One or SBS-SA,APP-
W-6 Polyglass ASTM C1289, HA Dens Deck Prime,SECUROCK HA SBS-SA more SBS- SA,SBS-TA -60.0
at max.24- Elastobase (square)with equally spaced, type II polyiso- Gypsum-Fiber Roof Board SA or APP- or APP-TA
inch spans Poly Roofgrip#12 staggered center cyanurate TA
rows
TABLE 113:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER
SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER
System Base Insulation Layer Top Insulation Layer Roof Cover MDP
No.
Deck(See Note 1) Type Fasteners Attach Type Attach Base Ply Cap (pso
Min.19/32-inch Min.1.5-inch Dekfast Hex with Min.0.75-inch FescoBoard (Optional if (Optional if using
SBS-TA,
W-7 plywood at max.24-inch ENRGY 3,H-Shield Dekfast#12 or TruFast 1 per z (homogeneous)or min.0.5-inch HA using AA Ply) AA Base)One or SBS-AA, -60.0
1.33 ft Structodek High Density Fiberboard more BP-AA or APP-TA
spans or Polytherm MP-3 with TruFast DP Roof Insulation BP APP-TA
Exterior Research and Design,LLC.d/b/a Trinity]ERD Evaluation Report A42970.10.12-R1 for FL16027-R1
Certificate of Authorization#9503 Revision 1:03/23/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 5 of 27
F)o
TRINITY I ERS
TABLE 1C:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER
SYSTEM TYPE C:MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER
System Deck(See Note 1) Base Insulation Top Insulation Layer Roof Cover MDP
No. Layer Type Fasteners Attach Base Ply Cap (Psf)
(Optional) Min.0.5-inch Structodek High Density
Min.19/32-inch Dekfast Galvalume (Optional if (Optional if using AA
One or more layers, Fiberboard Roof Insulation or min.0.25- 1 per 1.33 SBS-AA,SBS-TA,APP-
W-8 plywood at max. Steel Hex with 2 using AA Ply) Base)One or more BP-AA -82.5
24-inch spans any combination, inch Dens Deck,Dens Deck Prime or Dekfast#12 DP ft BP-AA or APP-TA TA
loose laid SECUROCK Gypsum-Fiber Roof Board
(Optional)
Dekfast Galvalume
1
Min.19/3.2-inch Steel Hex with \
One or more layers, Min.1.5-inch ENRGY 3,H-Shield or 1 per 1.33 (Optional)One or more SBS-SA,APP-SA,SBS-
W-9 plywood at max. Dekfast#12 DP or 2 SBS-SA -82.5
24-inch spans any combination, Polytherm TruFast MP-3 with ft SBS-SA or APP-TA TA or APP-TA
loose laid TruFast DP
TABLE 1D:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER
SYSTEM TYPE D:PRELIMINARILY ATTACHED INSULATION,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER
System Deck(See Note 1) Insulation Layer(s) Base Sheet Roof Cover MDP
No. Type Attach Base Fasteners Attach Ply Cap (Psf)
Polyglass Elastobase,Polyglass OMG Flat Bottom Plates
Min.19/32-inch One or more layers, Prelim. Elastobase Poly,Polyglass G2 Base, (square)with Roofgrip 12-inch o.c.in 4-inch lap and 12- (Optional)One SBS-AA,
W-10 plywood at max. CertainTeed Glasbase,Firestone MB #14,Dekfast Hex with inch o.c.in two,equally spaced, or more BP-AA SBS-TA, -52.5
24-inch spans any combination Attached Base,JM Perma-Ply 28,Tamko Glass Dekfast#14 or TruFast staggered center rows or APP-TA APP-TA
Base or GAFGLAS#75 - MP-3 with TruFast HD
Min.19/32-inch - Dekfast Hex with Dekfast 12-inch o.c.in 4-inch lap and 12-
SBS-SA,
W-11 plywood at max. One or more layers, Prelim. Polyglass Elastobase or Polyglass #14 or TruFast MP-3 with inch o.c.in two,equally spaced, One or more APP-SA, -52.5*
24-inch spans any combination Attached Elastobase Poly with poly top surface TruFast HD staggered center rows SBS-SA SBS-TA or
APP-TA
Min.19/32-inch One or more layers, Prelim. Polyglass Elastobase or Polyglass OMG Flat Bottom Plates 12-inch o.c.in 4-inch lap and 12- (Optional)One SBS-AA, /
W-12 plywood at max. inch o.c.in two,equally spaced, or more BP-AA SBS-TA, -60.0
24-inch spans any combination Attached Elastobase Poly (square)with Roofgrip#12 staggered center rows or APP-TA APP-TA
Min.19/32-inch 12-inch o.c.in 4-inch lap and 12- SBS-SA,
One or more layers, Prelim. Polyglass Elastobase or Polyglass OMG Flat Bottom Plates One or more APP-SA, *
W-13 plywood at max. any combination Attached Elastobase Poly with poly top surface (square)with Roofgrip#12 inch o.c.in two,equally spaced, SBS-SA SBS-TA or 60.0
24-inch spans staggered center rows APP-TA
Exterior Research and Design;LLC.d/b/a Trinity)ERD Evaluation Report A42970.10.12-131 for FL16027-R1
Certificate of Authorization#9503 Revision 1:03/23/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 6 of 27
e
F)o
TRINITY I ERD
TABLE 1E-1:WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF)
SYSTEM TYPE E:NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER
System Base Sheet Roof Cover MDP
Deck(See Note 1)
No. Base Fasteners Attach Ply Cap (psf)
Min.15/32-inch 9-inch o.c.at 2-inch lap and 18-inch o.c.in two, (Optional)BP-AA or SBS-AA,SBS-TA
W-14 plywood at max.24- Polyglass Elastobase Simplex MAXX Cap equally spaced,staggered center rows APP-TA or APP-TA -45.0*
inch spans
Min.15/32-inch 9-inch o.c.at 2-inch lap and 12-inch o.c.in two, (Optional)BP-AA or SBS-AA,SBS-TA
W-15 plywood at max.24- Polyglass Elastobase Simplex MAXX Cap equally spaced,staggered center rows APP-TA or APP-TA -52.5
inch spans
Min.19/32-inch
Polyglass Elastobase,Polyglass Elastobase One or
(Optional)
W-16 plywood at max. Poly,Polyglass G2 Base,CertainTeed 32 ga.,1-5/8-inch diameter tin caps 8-inch o.c.in 4-inch lap and 8-inch o.c.in three, (O SBS-AA,SBS
more BP-AA or
Glasbase,Firestone MB Base,JM Perma- with 11 ga.annular ring shank nails equally spaced,staggered center rows TA,APP-TA 60.0
24-inch spans Ply 28,Tamko Glass Base or GAFGLAS#75 APP-TA
Min.19/32-inch
W-17 plywood at max. BS-SA or SA,SBS-TA or -60.0
more S(Optional)One or SBS-SA,APP-
Polyglass Elastobase or Polyglass 32 ga.,1-5/8-inch diameter tin caps 8-inch o.c.in 4-inch lap and 8-inch o.c.in three,
24-inch inch spans Elastobase Poly with poly top surface with 11 ga.annular ring shank nails equally spaced,staggered center rows moreAPP- S APP-TA
Min.15/32-inch 6-inch o.c.at 2-inch lap and 6-inch o.c.in two, (Optional)BP-AA or SBS-AA,SBS-TA
W-18 plywood at max.24- Polyglass Elastobase Simplex MAXX Cap equally spaced,staggered center rows APP-TA or APP-TA -90.0
inch spans
Min.19/32-inch
W-19 plywood at max. BS-SA or SA,SBS-TA or -97.5
more S(Optional)One or SBS-SA,APP-
Polyglass Elastobase or Polyglass 32 ga.,1-5/8-inch diameter tin caps 4-inch o.c.in 4-inch lap and 4-inch o.c.in four,
24-inch inch spans Elastobase Poly with poly top surface with 11 ga.annular ring shank nails. equally spaced,staggered center rows moreAPP- S APP-TA
Min.15/32-inch 6-inch o.c.at 2-inch lap and 6-inch o.c.in three, (Optional)BP-AA or SBS-AA,SBS-TA
W-20 plywood at max.24- Polyglass Elastobase Simplex MAXX Cap equally spaced,staggered center rows _ APP-TA or APP-TA -105.0
inch spans
Min.19/32-inch (Optional)One or
Polyglass Elastobase or Polyglass 32 ga.,1-5/8-inch diameter tin caps 6-inch o.c.in 4-inch lap and 6-inch o.c.in four, SBS-AA,SBS-
W-21 plywood at max.
Elastobase Poly with 11 ga.annular ring shank nails equally spaced,staggered center rows more
BP-AA or TA,APP-TA -112.5
24-inch spans
32 ga.,1-5/8-inch diameter tin caps SBS-SA,APP-
W-22 plylyw000ddn. aat inch max. Polyglass Elastobase or Polyglass with 11 ga.annular ring shank nails. 6-inch o.c.in 4-inch lap and 6-inch o.c.in four, (Optional)One or
t SA,585-TA or 112.5
24-inch spans Elastobase Poly with poly top surface Note:Tin caps are to be primed with equally spaced,staggered center rows more APP-TA
APP-TA
ASTM D41 primer.
Exterior Research and Design,I.I.C.d/b/a Trinity IERD Evaluation Report A42970.10.12-R3 for FL16027-Rl
Certificate of Authorization#9503 Revision 1:03/23/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 7 of 27
TRINITY I ERD
TABLE 1E-2:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER
SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER
System Deck(See Note 1) Base Sheet Roof Cover MDP
No. Base Fasteners Attach Ply Cap (psf)
Polyglass Elastobase,Polyglass Elastobase
Min.19/32-inch OMG Flat Bottom Plates(square)with 12-inch o.c.in 4-inch lap and 12-inch (Optional)One or
W-1 Poly,Polyglass G2 Base,CertainTeed SBS-AA,SBS-
plywood at max. Roofgrip#14,Dekfast Hex with Dekfast#14 o.c.in two,equally spaced,staggered more BP-AA or -52.5
24-inch spans Glasbase,Firestone MB Base,JM Perma- or TruFast MP-3 with TruFast HD center rows APP-TA TA,APP-TA
Ply 28,Tamko Glass Base or GAFGLAS#75
Min.19/32-inch 12-inch o.c.in 4-inch lap and 12-inch SBS-SA,APP-
W-2 plywood at max. Polyglass Elastobase or Polyglass Dekfast Hex with Dekfast#14 or TruFast MP- o.c.in two,equally spaced,staggered One or more SBS- SA,SBS-TA or -52.5*
24-inch spans Elastobase Poly with poly top surface 3 with Tru Fast HD center rows SA APP-TA
Min.19/32-inch 12-inch o.c.in 4-inch lap and 12-inch (Optional)One or
Polyglass Elastobase or Polyglass OMG Flat Bottom Plates(square)with SBS-AA,plywood at max. Elastobase PolRoofri #12 O.C.in two,equally spaced,staggered more BP-AA or TA,APP-TA -60.0
y gp
24-inch spans center rows APP-TA
Min.19/32-inch 12-inch o.c.in 4-inch lap and 12-inch SBS-SA,APP-
W-4 plywood at max. Polyglass Elastobase or Polyglass OMG Flat Bottom Plates(square)with O.C.in two,equally spaced,staggered One or more SBS- SA,SBS-TA or 60.0*
24-inch spans Elastobase Poly with poly top surface Roofgrip#12 center rows SA APP-TA
TABLE 1F:WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF)
SYSTEM TYPE F:NON-INSULATED,BONDED ROOF COVER
System Deck Primer Roof Cover MDP
No. Joint Treatment Base Ply Cap (Psfl
W 5 Min.15/32-inch plywood (Optional)ASTM D41 None SBS-SA (Optional)SBS-SA or SBS=SA,APP-SA,SBS-TA 90 -
at max.24-inch spans APP-TA or APP-TA
W6
Min.15/32-inch plywood (Optional)ASTM D41 Plywood joints are covered with 4-inch wide strips of TriBuilt SA TriBuilt SA SBS Base (Optional)SBS-SA or SBS-SA,APP-SA,SBS-TA g7 5 ] '
at max.24-inch spans SBS Base,rolled into place to create continuous bond. APP-TA or APP-TA
Exterior Research and Design,LLC.d/b/a Trinity)ERD Evaluation Report A42970.10.12-111 for FL16027-R1
Certificate of Authorization#9503 Revision 1:03/23/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 8 of 27