Loading...
HomeMy WebLinkAboutProduct approvals, shingles Florida Building Code Online 1}-1t Lt5 COP116f4 BCIS Home i Log In User Registration Hot Topics 4 Submit Surcharge Stats&Facts Publications i FBC Staff j BCIS Site Map Links search i Florida P ��'USER:Public r E Al MEM Product Approval Menu>Product or Application Search>Application List>Application Detail M FL# FL1956-R12 Application Type Editorial Change Code Version 2014 Application Status Approved i *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived L� I Product Manufacturer TAMKO Building Products,Inc. Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerri_eden@tamko.coTHESE PLANS AND A16L PROPOSED WOSK Authorized Signature Kerri Eden io ARE SUBJECT TO ANY CORRECTIONS kerri_eden@tamko.comREQUIRED BY FIELD INSPECT®RS THAT- Technical Representative Kerri Eden Y r Address/Phone/Email PO Box 1404 �6 C� ,% ® ®ER TO,,. Joplin,MO 64802 C�i/pdfp H ALL°APPLICABLE GOgES. (417)624-6644 Ext 2l0�'"_Yd kerri—eden@tamko.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles i Compliance Method Certification Mark or Listing I Certification Agency UL LLC Validated By Robert J. M. Nieminen,PE I Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2009 ASTM D3462 2009 ASTM D7158 2008 Equivalence of Product Standards Certified By� 1���- �� ST.L C?L'Cr1L1�i R1JII� �1ViSIQ�1 RE tiVED FOR COIN LNCE tD n . fiE MI MUST BE KEPT ON JOB . Product Approval Method Method 1 Optl65'FANTO MPEIC'ION NMI.BCE MADE.! Date Submitted 09/17/2015 I i https:Hfloridabuilding.I g/pr/pr app_dtl.aspx?param=wGEVXQwtDgs%2fmGFoyT6raQ... 1/16/2017 Florida Building Code OI ine e 2 of 4 c Date Validated 10/06/2015 Date Pending FBC Approval Date Approved 10/09/2015 I i Summa of Products FL# Model,Number Description or Name 1956.1 Elite Glass-Seal A three tab asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 RS1 C CAC Tamko Sery Conf FL 1956 2015.odf HVHZ:No FL1956 R12 C CAC UL certification 10-11-12.12df i Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure: N/A FL1956 R12 II Glass Seal Elite Glass Seal amp inst.mdf Other.Asphalt shingles Verified By: Robert Nieminen 59166 shall be used only on roof Created by Independent Third Party: No slopes of 2:12 or greater. Evaluation Reports Nails must be used as the Created by Independent Third Party: method of attachment. 1956.2 1 Glass-Seal A three tab asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 Rll C CAC Tamko Sery Conf FL 1956 2015.mdf HVHZ: No FL1956 R12 C CAC UL certification 10-11-12.pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure:N/A FL1956 R12 II Glass Seal Elite Glass Seal apt) inst.oddf Other:Asphalt shingles Verified By: Robert Nieminen PE 59166 shall be used only on roof Created by Independent Third Party: No slopes of 2:12 or greater. Evaluation Reports Nails must be used as the Created by Independent Third Party: method of attachment. 1956.3 1 Heritage A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.pdf HVHZ: No FL1956 R12 C CAC UL certification 10-11-12.pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure: N/A FL1956 R12 II Heritage D F I P app inst.odf Other:Asphalt shingles FL1956 R12 II Heritage F aop inst.mdf only on roof FL1956 R12 II Heritage T app inst.ndf slo s of 2:1 reater. Verified By: Robert]. M.Nieminen FL 59166 ails must be u d the Created by Independent Third Party: No method of attach nt. Evaluation Reports Created by Independent Third Party: 1956.4 1 Heritage 30 A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 RI C CAC Tamko Sery Conf FL 1956 2015.pdf VHZ:No FL1956 R12 C CAC UL certification 10-11-12.pdf A d for use o de Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure:N/A FL1956 R12 II heritage 30 app inst april 10.odf Other:Asphalt shingles FL1956 R12 II heritage 30 app inst f april 10.pdf shall be used only on roof Verified By: Robert Nieminen PE 59166 slopes of 2:12 or greater. Created by Independent Third Party: No Nails must be used as the Evaluation Reports method of attachment. Created by Independent Third Party: i 1956.5 Heritage 50 A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.pdf HVHZ:No' FL1956 R12 C CAC UL certification 10-11-12.odf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure: N/A FL1956 R12 II heritage 50 app inst april 10.pdf Other:Asphalt shingles FL1956 R12 II heritage 50 aop inst f april 10.pdf shall be used only on roof Verified By: Robert Nieminen PE 59166 slopes of 2':12 or greater. Created by Independent Third Party: No Nails mustibe used as the Evaluation Reports method of attachment. Created by Independent Third Party: I https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs%2fmGFoyT6raQ... 1/16/ 017 i Florida Building Code Online age 3 of 4 1956.E 1 Heritage Premium A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.odf HVHZ: No FL1956 R12 C CAC UL certification 10-11-12 odf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes; 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure:N/A FL1956 R12 II Heritage Premium D P app inst.pdf Other:Asphalt shingles FL1956 R12 II Heritage Premium F app inst.pdf shall be used only on roof FL1956 R12 II Heritage Premium T app inst.pdf slopes of 2:12 or greater. Verified By: Robert Nieminen 59166 Nails must be used as the Created by Independent Third Party: No method of attachment. Evaluation Reports Created by Independent Third Party: 1956.7 Heritage Vintage A heavy weight dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.pdf HVHZ:No FL1956 R12 C CAC UL shingle matrix,pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure: N/A FL1956 R12 II Heritage Vintage app inst.pdf Other:Asphalt shingles Verified By: Robert J. M.Nieminen PE 59166 shall be used only on roof Created by Independent Third Party: No slopes of 2:12 or greater. Evaluation Reports Nails must be used as the Created by Independent Third Party: method of attachment. 1956.8 Heritage Vintage Hip and ridge shingles 12 X 12 Hip and Ridge Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.pdf HVHZ: No FL1956 R12 C CAC UL shingle matrix.pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure: N/A FL1956 R12 II TAMKOR Heritage(p) 12 x 12 Hip and Ridge Application Instructions.pdf Other:Asphalt shingles Verified By: Robert J. M. Nieminen PE 59166 shall be used only on roof Created by Independent Third Party: No slopes of 2:12 or greater. Evaluation Reports Nails must be used as the Created by Independent Third Party: method of attachment. i 1956.9 Heritage A dimensional asphalt shingle. Woodgate Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.pdf HVHZ: No ' FL1956 R12 C CAC UL certification 10-11-12.odf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure:N/A FL1956 R12 II Heritage Woodgate D am) inst.pdf Other:Asphalt shingles FL1956 R12 II Heritage Woodgate F am) inst.pdf shall be used only on roof Verified By: Robert Nieminen 59166 slopes of 2:12 or greater. Created by Independent Third Party: No Nails must be used as the Evaluation Reports method of attachment. Created by Independent Third Party: 1956.10 1 Heritage XL A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 R1I C CAC Tamko Sery Conf FL 1956 2015.odf HVHZ: No FL1956 R12 C CAC UL certification 10-11-12.pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes, 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure: N/A FL1956 R12 II heritage A app inst d april Modf Other:Asphalt shingles FL1956 R12 II heritage xl app inst f april 10.ndf shall be used only on roof Verified By: Robert Nieminen PE 59166 slopes of 2:12 or greater. Created by Independent Third Party: No Nails must be used as the Evaluation Reports method of attachment. Created by Independent Third Party: 1956.11 Hip and Ridge Hip and ridge shingles Shingles Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.odf HVHZ:No FL1956 R12 C CAC UL certification 10-11-12.pdf https://Roridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs%2fmGFoyT6raQ... 1/16/2017 •Florida Building Code Online e 4 f 4 CIOApproved for use outside Quality Assurance Contract Expiration Date w rSt HVHZ:Yes . 09/17/2018 1 Impact Resistant:N/A Installation Instructions Design Pressure: N/A FL1956 R12 II 12.25x12 Hip and Ridge.Ddf Other:Hipland Ridge FL1956 R12 II 12 x 12 Hip Ridge ADDlication Instructions.Ddf shingles shall be used only FL1956 R12 II 12-1-4x12 HipRidge Sealant Dab Illustrations pdf on roof slopes of 2:12 or FL1956 R12 II 12x12 HipRidge Sealant Dab Illustrations Ddf greater.Nails must be used Verified By: Robert Nieminen 59166 as the method of Created by Independent Third Party: No attachment. Evaluation Reports Created by Independent Third Party: Back Next Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement:;Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address ifs they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here_. Product Approval Accepts: Credit Card Safe https:Hfloridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs%2fmGFoyT6raQ... 1/16/21 17 ji ® Application Instructions for TAMKO HERITAGE® 30 BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES Dallas,TX •Tuscaloosa,AL• Phillipsburg, KS • Joplin, MO I THESE ARE THE MANUFACTURER'S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS,INC.ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING DEFECTS RESULTINGi FROM FAILURE TO FOLLOW THE MANUFACTURER'S INSTRUCTIONS. THIS PRODUCT IS COVERED BY A LIMITED WARRANTY,THE TERMS OF WHICH ARE PRINTED ON THE WRAPPER. i IN COLD WEATHER(BELOW 40°17),CARE MUST BE TAKEN TO AVOID DAMAGE TO THE EDGES AND CORNERS OF THE SHINGLES, IMPORTANT It is not necessary to remove the plastic strip from the back of the shingles. 1.ROOF DECK S.FASTENERS j These shingles are forapplication to roof decks capable of receiving WIND CAUTION: Extreme wind velocities can damage these and retaining fasteners,and to inclines of not less than 2 in.per foot. shingles after application when proper sealing of the shingles For roofs having pitches 2 in.per foot to less than 4 in.per foot,refer does not occur.This can especially be a problem if the shingles to special instructions titled"Low Slope Application".Shingles must are applied in cooler months or in areas on the roof that do not be applied properly.TAMKO assumes no responsibility for leaks or receive direct sunlight.These conditions may impede the sealing defects resulting from improper application,or failure to properly of the adhesive strips on the shingles.The inability to seal down prepare the surface to be roofed over. may be compounded by prolonged cold weather conditions and/ NEW ROOF DECK CONSTRUCTION:Roof deck must be smooth, or blowing dust.In these situations,hand sealing of the shingles is dry and free from warped,surfaces. It is recommended that metal recommended.To insure immediate sealing,apply 4 quarter-sized drip edges be installed at eaves and rakes. dabs of TAM-PROID Premium SBS Adhesive or TAMKO Tam-Seal Adhesive on the back of the shingle 1 in.(25mm)and 13 in.(330mm) PLYWOOD:All plywood shall be exterior grade as defined by the in from each side and 1 In. (25mm) up from the bottom of the Engineered Wood Association.Plywood shall be a minimum of 3/6 shingle. Press shingle firmly into the adhesive.For maximum wind in.thickness and applied in accordance with the recommendations resistance along rakes,cement shingles to the underlayment'and of the Engineered Wood Association. each other in a 4 in.(102mm)width of TAM-PRO SBS Adhesive or SHEATHING BOARDS: Boards shall be well-seasoned tongue- TAMKO Tam-Seal Adhesive. Caution:Apply ONLY a thin uniform and-groove boards and not over 6 in.nominal width.Boards shall layer of adhesive less than 1/8 in.(3mm)thick.Excessive amounts be a 1 in. nominal minimum thickness. Boards shall be properly can cause blistering of the shingles and may soften the asphalt in spaced and nailed. certain underlayments resulting in the asphalt flowing,dripping and staining.Shingles must also be fastened according to the fastening 2.VENTILATION instructions described below. Inadequate ventilation of attic spaces can cause accumulation of Correct placement of the fasteners is critical to the performance moisture in winter months and a build up of heat in the summer. of the shingle. If the fasteners are not placed as shown in the These conditions can lead to: diagram and described below,this will result in the termination of TAMKO's liabilities under the limited warranty.TAMKO will not be 1.Vapor Condensation responsible for damage to shingles caused by winds in excess of 2.Buckling of shingles due to deck movement. the applicable mph as stated in the limited warranty. See limited warranty for details. 3.Rotting of wood members. FASTENING PATTERNS:Fasteners must be placed 6-1/8 in.,from 4.Premature failure of roof. the bottom edge of the shingle,penetrating through the common bond,and located horizontally as follows: To insure adequate ventilation and circulation of air,place louvers of sufficient size high in the gable ends and/or install continuous 1)Standard Fastening Pattern.(For use on decks with slopes 2 In. ridge and soffit vents. FHA minimum property standards require per foot to 21 in.per foot.)One fastener 1 in. back from each end one square foot of net free ventilation area to each 150 square feet and one 13-1/2 in.back from each end of the shingle for a total of 4 of space to be vented,or one square foot per 300 square feet if a fasteners.(See standard fastening pattern illustrated below). vapor barrier is installed on the warm side of the ceiling or if at least one half of the ventilation is provided near the ridge.If the ventilation STANDARD FASTENING PATTERN openings are screened,the total area should be doubled. FASTENERS NAZI!ZONE COMMON BOND IT IS PARTICULARLY IMPORTANT TO PROVIDE ODE(HATE NTILATIQN. [EXPOSURE 1'—►I 12-1/2°—+—12-3/8"—►- 12-1/2"--� �-1" (Continued) Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 11/09 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 tamko.com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 j 1 i l (CONTINUED from page 1) t TAMKO HERITAGE® 30 BM60ING PRODUCTS 6AMINATED ASPHALT SHINGLES Dallas, TX •Tuscaloosa,AL• Phillipsburg, KS • Joplin, MO 2) Mansard Fastening Pattern. (For use on decks with slopes be a minimum of 1-1/4 in.for new construction and 1-1/2 inJ for greater than 21 in.per foot.)One fastener 1 in.back from each end reroofing thus allowing a minimum deck penetration of 3/4 in.The and one fastener 8-1/2 in.back from each end and one fastener 16 crown of the staple must be parallel to the length of the shingle. in.back from each end for a total of 6 fasteners per shingle.(See The staple crown should be driven flush with the shingle surface. Mansard and High Wind Fastening Pattern illustrated below.) Staples that are crooked,underdriven or overdriven are considered MANSARD AND HIGH WIND FASTENING PATTERN improperly applied. FASTENERS NAIL ZONE Properly Driven Improperly Driven COMMON s,b, underonven overdriven crooked BOND Ft=N Asphalt ~Shingles S-Z EXPOSURES-5/B° E � Decking 3) �"-'I IFi-�rz"►Ire-irz^-►�-�-aia�a-�-�2-+��-�2°�I �-i° ��<m�. � 3) High Wind Fastening Pattern. (For High Wind Application CAUTION:ALL FASTENERS MUST BE DRIVEN INTO THE NAIL requirements)One fastener 1 in.back from each end.One fastener ZONE/COMMON BOND AS SHOWN IN THE DIAGRAM ABOVE. 8-1/2 in.back from each end and one fastener 16 in.back from each 4.UNDEHLAYMENT end for a total of six(6)fasteners per shingle.In addition to this shingle fastening pattern requirement for High Wind Application,TAMKO UNDERLAYMENT:An underlayment consisting of asphalt saturated also requires the use of the following TAMKO products: TAMKO felt must be applied over the entire deck before the installation of felts or underlayments;TAMKO Moisture Guard Plus underlayment TAMKO shingles.Failure to add underlayment can cause premature at all eaves,rakes,and valleys;TAMKO or TAM-PRO cements and failure of the shingles which is not covered by TAMKO's limited coatings products where required;TAMKO ventilation where required, warranty.Apply the felt when the deck is dry.On roof decks 4 in. TAMKO starter shingles if available in area,and TAMKO Hip and Ridge per foot and greater apply the felt parallel to the eaves lapping each shingles installed on all hips and ridges.Along rakes,cement shingles course of the felt over the lower course at least 2 in.Where ends to the underlayment and each other in a4 in.(102 mm)width of TAM- join, lap the felt 4 in. If left exposed, the underlayment felt may PRO SBS Adhesive or TAMKO Tam-Seal Adhesive.Also,see local be adversely affected by moisture and weathering. Laying of!the building codes for proper nailing application.High Wind Application underlayment and the shingle application must be done together. is offered on new construction or complete tear-off applications only. Products which are acceptable for use as underlayment are; It is not offered for recover applications. If High Wind Application requirements are not followed,the High Wind Application Warranty — TAMKO No.15 Asphalt Saturated Organic Felt MPH,as stated on Table I in the Limited Warranty, reverts to the — A non-perforated asphalt saturated organic felt which meets Standard Application Wind Warranty MPH limit.(See Mansard and ASTM:D226,Type I or ASTM D4869,Type I High Wind Fastening Pattern illustrated above.) — Any TAMKO noD-perforated asphalt saturated organic felt NAILS:TAMKO recommendsthe use of nails as the preferred method — TAMKO TW Metal and Tile®nderlayment,TW Underlayment and Moisture Guard Plus (additional ventilation may be of application. Standard type roofing nails should be used. Nail required.Contact TAMKO's Technical Services Department shanks should be made of minimum 12 gauge wire,and a minimum for more information.) head diameter of 3/8 in.Nails should be long enough to penetrate 3/4 in.into the roof deck.Where the deck is less than 3/4 in.thick, In areas where ice builds up along the eaves or a back-up of water the nails should be long enough to penetrate completely through from frozen or clogged gutters is a potential problem,TAMKO's plywood decking and extend at least 1/8 in.through the roof deck. Moisture Guard Plus®waterproofing underlayment(or any specialty Drive nail head flush with the shingle surface. eaves flashing product) may be applied to eaves, rakes, ridges, valleys, around chimneys, skylights or dormers to help prevent Properly DAven Improperly Odven water damage.Contact TAMKO's Technical Services Department OJ3WMIndlameter underdrl— ovmdrtm crooked for more information. Asphalt j Shingles TAMKO does not recommend the use of any substitute products sacking as shingle underlayment. tb^nanl°al S.APPLICATION INSTRUCTIONS 4 straight,good penetration, Inadequate too deep,cuts Inadequate i and Ik,sh with shingle surface pane+'°°.. Into ahinge ...h°r°I>° STARTER COURSE:A starter course may consist of TAMKO Shingle Starter,self-sealing 3-tab shingles or a 9 inch wide strip of mineral STAPLES: If staples are used in the attaching process,follow the surface roll roofing.If self-sealing 3-tab shingles are used,remove above instructions for placement All staples must be driven with the exposed tab portion and install with the factory applied adhesive pneumatic staplers.The staple must meet the following minimum adjacent to the eaves. Attach the starter course with approved dimensional requirements.Staples must be made from a minimum fasteners along a line parallel to and 3 in.to 4 in.above the eaves 16 gauge galvanized wire.Crown width must be at least 15/16 in. edge.The starter course should overhang both the eaves and rake (staple crown width is measured outside the legs)..Leg length should edges 1/4 in.to 3/8 in. (Continued) Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 11/09 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 tamko.eom Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 I 2 r ® (CONTINUED from page 2) � � "ITAMKOI HERITAGE® 30 BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES Dallas,TX •Tuscaloosa,AL• Phillipsburg, KS • Joplin, MO SHINGLE APPLICATION:Start the first course with a full size shingle S.6OW SLOPE APPLICATION and overhang the rake edge 1/4 in.Cut 10-3/8 in.from a full shingle On pitches 2 in.per footto 4 in.perfoot coverthe deck with two layers to form a shingle 291n.long.Use this to start the second course(see of asphalt saturated felt.Begin by applying the felt in a 19 in.wide strip diagram below).Cut a 23 in.long shingle to start the third course.Use along the eaves and overhanging the drip edge by 1/4 to 3/4 in.Place the remaining 16-3/8 in.piece of shingleto start the fourth course and a full 36 in.wide sheet over the 19 in.wide starter piece,completely use the remaining 10-3/8 in.piece to begin the fifth course.Continue overlapping it.All succeeding courses will be positioned to overlap the up the rake in as many rows as necessary using the same formula preceding course by 19 in.If winter temperatures average 25eF or less, as outlined above.The butt of the shingle should be aligned with thoroughly cement the felts to each other with TAM-PRO or TAMKO the top edge of the sawtooth of the underlying shingle for a 5-5/8 in. Plastic Roof Cement from eaves and rakes to a point of a least 24 in. exposure(see shingle application drawing illustrated on this panel), inside the interior wall line of the building.As an alternative,TAMKO's When you make your final cut atthe roof's edge,flip any pieces that Moisture Guard Plus®self-adhering waterproofing underlayment may are 8 in.or longer back onto the roof.These pieces can be worked be used in lieu of the cemented felts. in anywhere without creating zippers or color variations. NOTE Do not align joints of shingle courses when working in cut 7•MANSARD ROOF OR STEEP S60PE ROOF pieces.Joints should be no closer than 4 in.from one another. If the slope exceeds21 in.per foot(60),each shingle must besealedwith TAM-PRO SBS Adhesive or TAMKO Tam-Seal Adhesive immediately upon installation.Spots of cement must be equivalent in size to a$.25 piece and applied to shingles with a 5-5/8 in.exposure,use 6 fasteners 10-3/6° per shingle.See Section 3 for the Mansard Fastening Pattern. 8.RE-ROOFING copses 16-3/6" 10-3/6" 2s° Before re-roofing,be certain to inspect the roof decks.All plywood 23, shall meet the requirements listed in Section 1. Nail down or remove curled or broken shingles from the existing ' 16-3i6° 23" roof.Replace all missing shingles with new ones to provide a smooth rake `` ' 'Full base.Shingles that are buckled usually indicate warped decking N3/8 or protruding nails. Hammer down all protruding nails or remove them and refasten in a new location. Remove all drip edge metal 5th course 23" 16�l8" and replace with new. ath course If re-roofing over an existing roof where new flashing is required 3rd course to protect against ice dams(freeze/thaw cycle of water and/or the end course '9„ backup of water in frozen or clogged gutters),remove the old roofing point at least 24 in. beyond the interior wall line and apply 1stcourseavFull 10-3/9" TAMKO's Moisture Guard Plus®waterproofing underlayment.Contact ~�°ems TAMKO's Technical Services Department for more information. Measurements will vary when nesting overan existing 5 in.exposure single roof:Call TAMKO Technical Services for further information. Cut your first course shiryle to meae 29'end a 103/6' 1.length.Cut a second shirgle to make a 234 and The nesting procedure described below is the preferred method for a 183/6'Ieng1R ,o3re reroofing over existing metric size shingles with a 5-5/8 in.exposure. ' P See description below: �• 18�. Starter Course:Remove the tabs and an additional portion from the head of a full size shingle so that its height is equal to the exposure of the existing shingles.Position the resulting strip over the existing =, roof edge(with the factory-applied adhesive strip along the eaves). Cut approximately 6 in.from the rake end and apply the remaining portion at the eaves.Continue the starter strip by applying full length shingle strips cut to height as above,evenly along the existing roof at the eaves.The existing roof should overhang the eaves far Z.eegm ca appuuon who a full length shingle. I rnen lay your 29'.23'.163/tl'and 10316'lenOths. enough to carry water off into the gutter.If this is not the case, threat wiNNro cuts cut and apply the starter strip so that it will provide sufficient m overhang for proper drainage. 3.Cmgnuetthem working reedgyour ayawsypiece the othatama When cu longermake your First Course:Remove an amount from the butt edge of a full-size Ilnal at at ma roots edge.sip eny pieces that am tl'of longer back onto the root These plecs;can he worked In arywham without shingle so that the remaining portion of the shingle fits between the creating zippers or color variations. NOTE:Do not align joints of shingle courses when working In butts of the existing third course.This course must also be applied cut pieces.Johns should be no c oser than a•from one another. evenly along the eaves edge of the new starter strip. (Continued) Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 11/09 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 tamkoxom Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 3 { (CONTINUED from page 3) + , [TAMKO" HERITAGE® 30 BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES Dallas,TX •Tuscaloosa,AL• Phillipsburg, KS • Joplin, MO ` I Second and Succeeding Courses: Remove 10-3/8 in.from the FOR ALTERNATE VALLEY APPLICATION METHODS, PLEASE rake end of the first shingle in the second course, and continue CONTACTTAMKO'S TECHNICAL SERVICES DEPARTMENT. with full width shingles for the remainder of the course, placing the top edge of each new shingle against the butt edge of the old vaCey ce teritne shingle in the course above.This method should create an exposure ofN F 6' eat of 5-5/8 in.after the first course.When beginning the Guard PSnsor 50 lb. 1 Extra nail In e9. ge succeeding or heavier roll roofing end of shingle courses continue to follow the Heritage application instructions. Extend end shingiel 't>eyond (See section 5). 12'-78 valleycentedne Existing shingles \\ i Y� Undorl.m t Nofaat-orowRhin 5 5/8' 6'of centedine 131/4" 1 /4" Drip edge glace tlp o1 sNngle on the edge of Dripedge the vertical shirgle,2 inches back 9 from valley=rine and covering New shingles the vertical shtrgle. 5 5/8" \ 5 5/8"exposure 10.HIP AND®DIGE FASTENING DETAIL exposure Apply the shingles with a 5 in.exposure beginning at the bottom of the hip or from the end of the ridge opposite the direction of the 9.VALLEY APPLICATION prevailing winds.Secure each shingle with one fastener on each side, 5-1/2 in.back from the exposed end and 1 in.up from the edge. of TAM a shingle underlaymene center a minimum 36 in.wide sheet TAMKO recommends the use of TAMKO Hi & Ridge shingle of TAMKO Nail-Fast,Moisture Guard Plusa or a minimum 50 lb.roll products.Where matching colors are available, is acceptable 9 0 roofing in the valley.Nail the felt only where necessary to hold it in use TAMKO's Elite Glass-Seal shingles cut down to 12 in.pieces. place and then only nail the outside edges. IMPORTANT:PRIOR TO INSTALLATION WARM SHINGLES TO Fasteners should be 1/4 in.longer than the one used for shingles PREVENT DAMAGE WHICH CAN OCCUR WHILE BENDING IMPORTANT. PRIOR TO INSTALLATION, CARE NEEDS TO BE SHINGLES TO FORM VALLEY. TAKEN TO PREVENT DAMAGE WHICH CAN OCCUR WHILE After valley flashing is in place: BENDING SHINGLE IN COLD WEATHER. • Apply the first course of shingles along the eaves of one of the Direction of prevailing wind intersecting roof planes and across the valley. Start 5"exposure Note:For proper flow of water over the trimmed shingle,always here— 1 n start applying the shingles on the roof plane that has the lower slope or less height. F,sIt n � `5-1/2' • Extend the end shingle at least 12 in.onto the adjoining roof. ' it Start Apply succeeding courses in the same manner,extending them here 511 exposure across the valley and onto the adjoining roof. • Press the shingles tightly into the valley. THESE ARE THE MANUFACTURER'S APPLICATION • Use normal shingle fastening methods. INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED.TAMKO BUILDING PRODUCTS, INC.ASSUMES Note:No fastenershould bewithin 6 in.of the valley centerline, NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING and two fasteners should be placed at the end of each shingle DEFECTS RESULTING FROM FAILURE TO FOLLOW THE crossing the valley. MANUFACTURER'S INSTRUCTIONS. • To the adjoining roof plane,apply one row of shingles vertically facing the valley and 2 in.back from the valley centerline. Note- For a neater installation, snap a chalkline over the Tademar Moisture Guard Plus®,Nail Fast®,TAM-PRO®and Heritage®are registered P trademarks of TAMKO Building Products,Inc. shingles for guidance. Information included in these application Instructions was current at time of printing.ITo • To complete the valley, apply shingles on the adjoining roof obtain a copy of the most current version of these application instructions,visit us online plane by positioning the tip of the first shingle of each row at at tamko.com or call us at 800-641-4691. the 2 in.point from the centerline where the edge of the vertical shingle has been applied,covering the vertical shingle. I Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 11/09 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 tamko.eom Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 4 I