Loading...
HomeMy WebLinkAboutBldg plans3' x 3' x 0.050' MIN. 6063-T6 ALLOY PLATE OR STRONGER (WE SIDE) WITH (3) - #12 x %' S.M.S. EACH SIDE AS SHOWN <%' MIN. PLATE EDGE DISTANCE 4 C-C FASTENER SPACING) 3' x 2' x D.O50' MIN. 6063-T6 ALLOY PLATE 09 STRONGER MINE SIDE) (3) - #12 SAS, EACH SIDE AS SHOWN (Y3' MIN. PLATE EDGE DISTANCE B C-C FASTENER SPACING) FOUNDATION CORNER POST CORNER POST V x 2' POLE PLATE 0 CONCRETE ANCHOR (2 PLACES) IN LIEU OF TYP. Y' 0 CONCRETE SCREWS FOR CORNER COLUMN THESE PLANS AND ALL PROPOSED WORM: ARE SUBJECT TO ANY CORRECTIONS REQUIRED.BY•FIELD INSPECTORS THAT MAYBE NECESSARY IN ORDER TO COMPLYWH ALL APPLICARLE CODE$. (5) #12x3/4^ S.M.S. 1x2 O.B. ATTACHED TO BEAM W/ (2)-#10X2" S.M.S. INTO SCREW 8O55 (1)-1/4•xYA• S.S. THRU-BOLT W/ Y4^ BUT AND WASHER 6 EACH S10E OF BEM( p12x2" S.M.S. - 1x2 O.B. TO SUPER GUTTER (TYP.) (4) #12x3/4^ S.M.S. ROOF BEAM (MT OR SLOPED) 2x24" ANGLE, EACH SIDE y� (FOR ACUTE ANGLE CONOMONS INSTALL ANGLES AND FASTENERS INSIDE THE BEAM) (4) #120/4" S.M.S. 5' Or 7' SUPER GUTTER M[N. 0.090' THICK 2' 0 DOLLOP W CONSTRUCTION J ADHESIVE B 5' o.c. NOTE, CONSTRUCTION ADHESIVE SHALL MEET ASTM C-557. NIN SHEAR STRENGTH R 7 DAYS = 425 PSI VE RAIL C31 TOTAL) - #12 V x 2' O.B. SAS AS SHOWN I - PATIO SEMON PLATE EDGE ➢IST C-C FASTENER SI 6' x 5' x 0450' 6063-76 ALLOY PLATE (ONE SIDE) DR STRONGER K-BRACE 204.070 CHAIR RAIL K-BRACE K-BRACE LATERAL"K'- BRACING CONNECTION DETAILS 1x5x1§' ANGLE 6' LONG <TYP, B EACH BEAM) -(2) Y{0x3' LG. 9 EACH ANGLE ROOF BEAM TO SUPER GUTTER CONNECTION DETAIL CALE_D,..F_A_S. TOM _ ORATTACN ______EQUALLY (TYP.)ARIHEWPOMYVRNESCREWS COLUMN GIRT (CHAIR RAIL) • SEE ELEVATIONS FOR N(' BRACE SIZE Ixtxk" BY Z^ LONG ANGLE, EACH SIOE (TYP.) (4) #14,y S.M.S.. 2 SCREWS EACH LEG (TYP.) HOLLOW POST NOTE. PRIMARY SCREEN ENCLOSURE BEAMS SHALL BE ATTACHED TO HOST STRUCTURE CONSISTING OF CONVENTIONAL TRUSS/RAFTER FRAMING WITH NAX. FACIA TO BE 2x6 (MIN) S.P.F. OVERHANG NO TO EXCEED 30' UNLESS OTHERWISE OR WESTER RED CEDAR NOTED ON PLAN DWG. STRUCTURAL GRADE 2 MIN. (1) Y4'Ox2' LG. LAG SCREW B 24' OZ. ENTIRE LENGTH OF GUTTER SECURE FASCIA TO EACH RAFTER TAIL (2) #1Ox4" S.M.S. THRU. 2x3 W/ (D Yi Ox4' LONG PAN HEAD LAG SCREWS SAVE RAIL INTO PURLIN SCREW BEFORE ATTACHING SUPER GUTTER BOSSES CDR) #10x3/4^ a 2' O.C. (U Yj Oxe- I.G. LAG SCREWS <TYP. R EACH BEAM) (V #12x2' SAS B 12. Oc. K) BETWEEN BEAMS THICK CWTINUOUS LE USE #IOX1 S.M.S. O 24" O.C.— TO CONNEC "TO 1.2 O.S. TO 2x3. 1x2 O.B. FASTENED TO COLUMN/POST W/(2) #1Oxt$" S.M.S. INTO SCREW POSSES SECURE FASCIA TO EACH RAFTER TAIL W/ (1) WOx4' LONG PAN HEAD LAG SCREWS BEFORE ATTACHING SUPER GUTTER Y( CONTINUOUS BEAD OF CONSTRUCTION ADHESIVE R BEAN 1 SCREWS (SEE TABLE) B 24' O.C. SPLICE "OF SPLICE PLATE (EACH SIDE H) 5052-H32 ALLOY OR EQQUAL., 1/0'B' flLh ROOF BEAM MOMENT CONNECTION DETAIL (GABLE OR MANSARD, T MAX. RISE. U.N.O.) �10 t- i33 i3 ST. LUC COUA'TY Ruil DT` G ➢IVISION REVIEWED FOR MPL1AA_CE ki E VIEWED Y DAT' PLANS AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE, 2x3xDO70 GIRT/CHAIR PAIL (SEE PLAN) MIN. (4) #10x2^ LONG S.M.S. INTO SCREW BOSSES (TYP. ALTERNATVE) I.M.B. POST CHAIR RAIL / GIRT TO POST CONNECTION DETAIL 2x PURUN (MAY BE SLOPED OR FLAT) _ -1 PURLIN FASTENED TO COLUMN/POST WITH (4) #12x1^ S.M.S. (EACH LEG) USING )6• THICK FLAT BAR BENT TO ITT (6063-T6 ALLOY) SIDEWALL POST / COLUMN TO PURLIN CONNECTION DETAIL s (3) #12(4S" S.M.S.. EACH LEG AND 6) #12,(V[ S.M.S. CHANNEL TO BEAM 9) SCREW TOTAL 1x1 A" ANGLE 3" LONG (EACH SIDE) W/ (3) #12.Y S.M.S. EACH LEG. 2x3%O.O45 EAW RNL ATTACHED TO BEAMS WITH (2) MIN. #104m S.M.S. INTO SCREW BOSSES(TYP.) USE #100h" S.M.S. O 24" O.C. TO CONNECT TO 1x2 O.B. TO 20. 1.2 O.B. FASTENED TO COLUMN/POST W/(2) #1005• S.M.S. INTO REEN DSSES (EACH TYP.) 2x3XOG70 PURUN MIN. (4) #10x3" LONG S.M.S. INTO SCREW BOSSES (TYP. ALTERNATIVE) BEAT STITCHING 6 24" O.C. (TYP. TOP AND BOTTOM OF SMB SEE TABLE FOR SIZES) PURLIN TO ROOF BEAM CONNECTION DETAIL A" BY 3' LONG :LE, EACH SIDE (TYP.) #124j" S.M.S„ EACH (6) TOTAL (TYP-) S.M.B. BEAM MAY BE SLOPED OR MT (SEE PLAN FDA SIZE) (9) #12xi,• S.M.S. EACH SIDE I OF BEAM ('IYP.) OR $' MIN., 3 Y{ MAX. C-C Od #12xY4• S.M.S. EACH 910E SPACING DF FASTENERS MP.) OF BFAM FOR 2x5 COLUMN TO 2.5 BEAM MIN. BEAM EDGE // (STANCE CTYP.) COLUMN/POST) MAIN POST / COLUMN TO ROOF BEAM CONNECTION DETAIL DO KIM S, ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS PO Box 10039 Tampa, FL 33679 Tel: (813) 374-0321 ISSUED By. FLA. REG. NUMBER 49497 DO KIM 8 ASSOCIATES, LLC CA# 26887 PO Box10039 Tampa, FL 33679 Drawing No. - 060811 SHEET IOF3 PuRuM SUP, CO MLU N/POSi— ;Nw/S" x 2" LG. ANGLE S.M.S. WITH MIN. W/ (4) /12x.T/4' S.M.S EGGE DISTANCE (EACH SIDE) i& CONCRETE ANCHOR 2 W/2ii' E� D CONCRETE (EACH SIDE) x SIDEWALL COLUMN TO CONCRETE CONNECTION DETAIL D ANGLE, EACH SIDE (TYP.) '0 CONCRETE ANCHOR W/2)A" EMBEOMEM INiO SfRIICTURAL CONCRETE (TnJ (4) #12.%' �1"r2" O.B. SOLE PLATE 2"r PURUN S( AND 9- FROM POST (IY N88 COLUMN/POST 'la 0.& SOLE P'IAIE SEE PUN FOR SRN i � 1x2 O.B. FASTENED TO CORNER + .. SECTION WfIH j14r UL• S.M.5.0 EDGE OF CONCRETE I' (TYP,) k _ 21' O.C. wTWn 8 2x2p4' ANGLE 26 LONG (EACH SIDE)¢ PLAN VIEW W/(2)) �14x;'j S.M.S. TO POST HVvY a 3/8 0 HD. GALY. p(P. BOLT # 00 W/ 2 1/2• MIN. EMBEDMENT CORNER POST/COLUMN TO FOUNDATION CONNECTION DETAIL S.M.S. WITH MIN. ie' )f• ANGLE. FACH SIDE (TYP.) EDGE DISTANCE 46"0 CONCRETE ANCHOR W/2%' EMBEDMENT INTO STRUCTURAL CONCRETE (IYP.) �1•r2" O.S. SOLE PLATE Y ~� �w 3' MIN. K'O-A" CONCRETE SCREW ANCHOR 0 24" O.C. AND 9- mom POST MP.) COWMN/POST W O.B. SOLE PLATE EDGE OF CONCRETE J I V (TYP.) �i PLAN VIEW MAIN COLUMN TO CONCRETE CONNECTION DETAIL ` �� RNATE (1) ANGLE E . W ANGLE (lam€) W/ 12AN S.M.S. 0 EACH ER INTERSECTION s ANGLE 2' LONG ON RMB/BEAM 91 1%"BRAS.M.S. PLAN - TYPICAL ROOF BRACE TO BEAM CONNECTION 1 BEAM MAY BE FLAT OR SLOPE[ W/10x2U: P EACH 'EACH a. 0 TYPCIAL FRONT VIEW OF POST TO FOUNDATION CONNECTION WITH PAVERS U" ^""�rtT - V 12" MIN! U.N.O ON PLAN ITANDARD TYP. INUOUS PERIMETER FOOTING DOTER 3RACE PLAN) ALTERNATE IV 2"x PURUN 20 BRACE li•0x2Pe• UUG SCREW . 12' D.C.. (1) W w 3' OF EDGES (IYP:) 1'x O.B. (TYPJ t NOTE; SUD FORBLOCK FRAMED MOUSES USE /14ra1S• CONCRETE SCREWAME WALL (1 1W O.C., 1 wONN 3' OF EDGES OYP.) TYPICAL SCREEN EDGE TO STRUCTURE CONNECTION DETAIL 2x2r1j' ANGLE CUP, CUT AT A 45• (+/-) ANGLE AND SEMI WY TO THE SCREEN ROOF BE FLAT SENA WRH ONE ((1) Yd0 THRU- OR SLOPED BOLT, WASHER. ATTACHEDED BEAM TO BEAM OR R O NO BE ATTACHED BRACING SHALL NOT BE TO ROOF PURUNS. ATTACHED W 0.093 BAKE (SEE PLAN) PLAN - TYPICAL DIAGONAL ROOF BRACE CONNECTION O 2r5xl6- ANGLE IZ LONG) V/ (27-014 TENS INTO TOP OF 2.3 EAVE RAIL AND (2)- PSI MIN. CONCRETE STRENGTH f 014 TEKS INTO THE FRONT OF THE CORNER POST 1x3 O.B. FASTENED TO CORNER COMPACTED OR SECTION WITH 01ox2• S.M.S. W/ UNDISTURBED SOIL/SAND %' DIA WASHER 0 18• D.C. -(2)-/5 REBAR. CONTINUOUS 3" MIN. CONC. COVER. 36" MIN. LAP SPLICE m POST I —I 2 O.B. TOP FRAME HER POST O.B. SIDE WN.L CORNER UPRIGHT ELEVATION VIEW CORNER POST/COLUMN UPRIGHT DETAIL 4" NOMINAL CONCRETE SUB (2500 PSI, MIN.) W/6x6x10/10 W.W.M. OR FIBER REINFORCED [POLYPROPYLENE FIBER - 1.5 POUND (MIN.)PER C.Y.) .. d. .� .. •. ai •.,..i .a 4 .• ( US ROIL OR COMPACTED CRUSHED ' CRUSHEDED UM UNFROCK (90TG PROCTOR) _ I MIN. (1)-#5 REBAR CONTINUOUS, SPLICE MUST OVERLAP 20" MIN. 3' COVER (TYP.) FOUNDATION/SLAB DETAIL DO KIM & ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS PO BOX 10039 Tampa, FL 33679 Tel:(813) 374.0321 J Z J w N LLJ w U f. N U U) Z O O a H H CC LU CO w CO U O DRAWN BY: DYK CHECKED BY: DYK SCALE: ASSHOWN DATE SHIM DO YEON KIM, P.E. FLA. REG. NUMBER 49497 DO KIM & ASSOCIATES, LLC CAW 261587 PO BOX 10039 Tampa, FL 33679 (24 /R Drawing No. - 060811 SHEET 2 OF _ BEAM tl (2) #100" S.M.S. THRU. 2x- i v E RAIL INTO PURLIN SC SCREW BOSSES D O V I A A M 1� & ASSOCIATES, LLC' — — — SE #ICOY2" S.M.S. ® 24" O.C. CONNECT TO 1x2 G.B. TO 2x3. CONSULTING STRUCTURAL 4C(EACH ENGINEERS PURLIN FASTENED TO COLUMN/POST.B. FASTENED TO COLUMN/POST WITH (4) #12x1" S.M.S. (EACH LEG) #1OX%" S.M.S. INTO SCREW BOSSES PO Box 10039 USING )6" THICK FLAT BAR BENT END, TYP.) Tampa, FL 33679 TO FIT (6063—T6 ALLOY) a Tel: (813) 374-0321 J lx5xYe' ANGLE 6' LONG (TYP. @ EACH BEAM) Rev.loat Description n vc ISSUED SEE PLAN FOR UPRIGHT SIZE N I (B) y'0x3 (— ' LG. @ EACH ANGLE (5) #12x3/4" S.M.S. ` f CM N O 0 0 2x24" ANGLE, EACH SIDE (TYP.) (4) #12x1" S.M.S., EACH LEG (TYP.) ATTACH SUPER GUTTER W/ (2) Y4"9x23'x" LAG SCREW ® EACH PURLIN AND (1) #14x2" LG. S.M.S ® 12" O.C. MAX. THE ENTIRE LENGTH OF SUPER GUTTER TRANSOM TO SUPER GUTTER CONNECTION General Notes and Specifications: 1. Contractor shall field verify all dimensions before construction and shall notify engineer of discrepancies for immediate consideration. 2. Concrete shall be minimum 28 day compressive strength of f'c=2500 psi, and be in accordance with the requirements of ACI 318. Reinforcing steel shalt have a min. yield strength of 40,000 psi (grade 40) and be provided with cover in accordance with ACI 318. 3. All dimensions are provided by contractor, 00 Kim & Associates, LLC have made interpretations where necessary. 4. The following structures are designed to be attached to block and wood frame structures of adequate structural capacity. The contractor shalt verify that the host structure is in good condition and of sufficient strength to hold the proposed addition. If there is a question about the host structure, the owner (at his own expense) shall hire an architect or engineer to verify host structure capacity. 5. Screen density shall be a maximum of 18 x 14 x 0.013" mesh. Wall screen shall be removed in accordance with Rule 611320-1.002 Alternative Design for Screen Enclosures. Aluminum shalt be 7005-T53 Alloy, 6005-T5 Alloy, or 6063-T6 Alloy based on industry standard shapes, thicknesses, and tolerances unless otherwise noted. 6. Unless otherwise noted, SMB shall be stitched with #100/4" SMS at 24"o.c., top and bottom. 7. Connections using screw bosses shall have minimum (4)-#10x2" per connection unless shown otherwise. 8. Unless otherwise shown, screws shall have minimum edqe distance and center -to -center distances as shown in this table. C-1022 Low Carbon Steel SMS & Self -Drilling REM Screws (Industry Standard Screws) Screw Nominal Screw Diameter (in) Minimum Edge Distance Minimum Center to Center Distance #10 0.188 /,s' V2 #12 0.219 #14 (1/4") 0,250 /2" /a" 9. Structure has been designed to meet the 511 Edition FBC (2014 FBC). Project is sited where the ultimate design wind speed, VW`, is 150 mph (3-sec gust) for risk category I buildings and other structures. Exposure C. Design pressures are from Table 2002.4, reduced by 0.88 for screen mesh factor, 0.6 for allowable stress design (ASO). J I— W O W U) O U J J U J Z C W 0) Z w U Of � U a� 1n C Z ao U � H W rUq J W U � CHECKED BY' DYK SCALE: AS SHOWN FLA. REG. NUMBER 49497 DO KIM & ASSOCIATES, LLC CAN 26887 PO Box 10039 Tampa, FL 33679 a `,1G.C1 10. Concrete anchors may be "Large Diameter Tapcons" (LTDs), Tapcon concrete screws, Simpson Strong -Tie Anchors or Titian Screws or approved equal. Drawing No. - 060811