Loading...
HomeMy WebLinkAboutEngineering i9f' TAI ..,.'i - -- 'g speed TDH CALCULATOR O 611 It 1 T1s 7 1 ) Pool lit farmation 0 Flow Rate: 52 GPM Total P'ip'ing Lengths:, N rSuction tiff: 3 Ft Inlet Side: 60 Ft DO c— Discharge Side: 60 Ft illlaximurn Pipe Velocity Allowed: Piping Si zes• ... N (consult yaurlocai code), Inlet Piping: 2.052 in (� Branch Pipinga 8 FUSec Discharge Piping 1.592 in ('r' InTet Piping: 8 Ft./Sec �-� Discharge.Piping: 10 Ft/Sec. Piping Head Loss at S.2;00Ga1/MIn: (nOi ELiCUC11ng'fitting Of V71J�5} 9 c— Inlet Piping 2.59 Ft h Disi i arge Piping 8.92 Ft LA b For advaneed pools that contain.mduple:suc601s,this programr may be /r MM inaccurate..- a hydraulics engineer, This program is for single pump N rt L1') syfems v.4th a single body of water S Results-You TDH Calculation, µ v rt- Suggested Mi.pirnurn Pipe Siaes: qz— Flow Rate: 52.00 Gal/Min Branch Piping 2.0 in Your Head Loss- 33.19 Ft inlet Pipings 2.0 In Maximum Fiow Rate Discharge Piping: 1.5 in at Maximum RPM: 67.34 Gal/Min Head Loss at Maximum Flow:Rate 52.90:Ft- System Head PPesSure Curve 100 4 a: e3. S 40 20 -:Os75hp,_E+,Full Stated„High Speed(012530). . Clean System � Desired Operation:PoR 0 - 0 20 40. 100 V6lumetric:Flcw Rate(GPM) Shcedted Components Components� Head.Loss at (D Name Quantity 52.00031/Min 1' 124 320 chlorinator 1.5; 2. 0,76, `, T �v'�t12 x 2 5 2 way valve PXC brain 0 2.02 0.6 1 5. 4,��. + 914 inch:.Retum 3 2.49. Z�lfR Sklmine.rX' 1 0:50 CD Piping T ^ inlet Discheirga Head Loss at,. tdanigi Quantity Quaitifji 52 OOGaUtViin r- N 90degree elbow 8:, 10 7 92 {, �r' '/►I �' Tee Through: 0 2 0.80 a Check ValveCD 0 1 2.26 N Name. Quantity. i' O 7.6hp E+,FuiLRated,High Speed 1 . +7a STAINLESS STEEL HANDRAIL ' (SAME BONDING FOR 18"MIN.-24"MAX. ter__ . LADDER) #8 SOLID BARE COPPER BOND WIRE W/APPR.CLAMPS EN'fONE ON EACH SIDE OF PERIMETER (TER POOL-4 TOTAL) -. 4"TO 6" BELOW SUB-GRADE 4g ANCHOR W/#8 BOND ......W.L..,,... WIRE&APPR.BOND � CLAMP 1-#8 BARE COPPER WIRE BONDED TO POOL -1 - STEEL AS SHOWN I � I #8 BOND WIRE W/APPR.CLAMP NOTE:BONDING GRID REQUIRED AT PERIMETER OF POOL IN AREAS LIGHT NICHE OF PAVED DECKING ONLY EQUIPOTENTIAL BONDING DETAIL PER FLORIDA BUILDING CODE ADAPTATION OF THE N.E.C.2011 SEC.680.26 Electrical Equipment Wiring, Grounding and Equipotential Bonding Loop #8 copper around Pool Installation must conform to the 2011 N.E.C. and applicable local codes Bonded to pool steel in 4 Places N.E.C. 2011 sec. 680.26(C) 12V LIGHT OPTIONAL 2N°LIGH SERVICE PANEL Install pool/spa per ANSI3,5,7 and 15 TRANSFORMER WAP JUNCTION-Box(s) DISCONNECT' J.B. MIN OF 8" I•e• W/P POOL TIMER W�S.T. ABOVE POOL DECK G.F.1 TOGGLE-SWITCH A POOL DECK NEGAWRovm1" NOTE: PVCCONDIRF WATER LINE WATER-PROOF G.F.I. 3#12IN / 01 n s CJ 0 VS v_Lt b ,0 •1�eJ b J V, MZ. MOST NOT BE MORE c a >y�• v THAN 20'-0"FROM 4 POOL-ITHEDGEAND .vpt NOT WITHIN 6'.0" / \ I� 1� 1. V C�1�I�J Y 1 Ci OF POOL-EDGE' Sec.680.22(3) — Phowe: 772 322 2626 FAX: 7'7 2.571 8102 AMAu,DHMWA-WOWMUuCAWMfTogCARMEIV06W o ELECTRICAL DIAGRAM