HomeMy WebLinkAboutProduct Approval Florida Building Code Onlint ,_-) Page 1 of 2
EsTt:
ms= '
Flaida Depalti mtof SCIS Home i Log In I User Registration I Hot Topless I Submit Surcharge I Stats a Facts I Publications I FBC Staff I SCIS Site Map I Links I Search
�TsMi
ProI 41.15rclt:Product Approval
Public User
Regulation
Product Approval Mernj!>Product or Annncation Search>Anpllcation List>Application Detail
FL# FL2569-R31
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived ❑
Product Manufacturer Soprema,Inc.(Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville,NON-US 00000
(819)478-2400 Ext 3327
memathieu@sop rema.ca
Authorized Signature Marc-Etienne Mathieu
memathleu@sop rema.ca
Technical Representative Marc-Etienne Mathieu
Address/Phone/Email 1688 lea n-Berchmans-Michaud
Drummondville,NON-US 00000
(819)478-2400 Ext 3327
_ —__._ __._. ._. ...._._. ....... .. .._.... ..__.....-.__memathieu@soprema.ca -._......
Quality Assurance Representative Jean-Francois Cote,Ph.D.
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca .
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert J,M.Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/16/2017
Validated By John W.Knezevlch,PE
2 Validation Checklist-Hardcopy Received
Certificate of Independence FLL2569 R11 COI 2015 01 COI Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2009
ASTM D6163 2000
ASTM D6164 2005
FM 4474 2004
FRSA/TRI April 2012(04-12) 2012
TAS 103 1995
TAS 110 2000
https://floridabuilding.ore./,nr/pr app_dtl.aspx?param=wGEVXQwtDgsKQFEnckB108Erx... 1/21/2016
Florida Building Code Online, Page 2 of 2
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted t 10/15/2015
Date Validated 10/19/2015
Date Pending FBC Approval 10/21/2015
Date Approved 12/15/2015
Summa of Products
FL# Model,Number or De cription
Name
2569.1 Soprema Roof Self adhering roof underlayments
Underlayments
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL2569 R11 II 2015 10 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569-
Approved for use outside HVHZt YesSR 1.odf
Impact Resistant:N/A Verified By:Robert Nleminen,P.E.PE-59165
Design Pressure:+N/A/-90 Created by Independent Third Party:Yes
Others 1.)Refer to ER Section 5 for Evaluation Reports
Limits of Use.2,)The design pressure FL2569 R11 AE 2015 10 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569-
noted herein pertains to underlaymentiR 1-od
systems used beneath adhesive-set file Created by Independent Third Party:Yes
systems.Refer to ER Section 5.6.4 for
details.
__._._.............
Contact Us;:1940 North Monroe Street.Tallahassee FL 32399 Phone:850487-1824
The State of Florida Is an AA/EEO employer,Coovrioht 20072013 State of Florida.::Privacy Statement::Accesslblllty Statement;;Refund Statement
Under Florida law,email addresses are public records.If you do not want your e•mall address released In response to a public-records request,do not send
electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487,1395.-Pursuant to
Section 455.175(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If
they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accoptst
®gg n
1 sccurit nth ittta
I ,
i
hUps://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsKQFEnckB 108Erx... 1/21/2016
EXTERIOR RESEARCH&.DESIGN,LLC.
Certificate DfAuthdrization#!9503
�TRINITYI 353 CHRISTIAN STREET,UNIT#13
ERD OXFORD,Cr 06478
PHONE:(203)262-9245
FAX:(203)262-9243
:EVALUATION REPORT
Soprema,Inc. Evaluation Repo rt,528020.06.09-R9
1640 rue.Haggerty FL2569-R31
Drummondville;Quebec J2C 5138 Date-of-Issuance:06/15/2009
Canada Revision 9:10/12/2015
SCOPE;
This Evaluation Report is Issued under Rule 616203 and the applica.bl.e rules arid'regulatlons gbv.erhing the use of
construction materials in the State of Florida.The documentation submitted has been'reviewed-by Robert Nieminen,
RE. for use of the product under ithe Florida Building Code and Florida Building Code, Residential Volume. The
products described herein.have been evaluated for compliance with the 5th Edition.(2014) Florida Building Code
sections noted-herein.
DESCRIPTION: Suprema Roof`Underlayments
LABELING: Labeling shall be in accordance with the requirements the,Accredited Quality Assurance Agency noted
herein.
CONTINUEDCOMPLIANCE.: This EValuat on Report lsvaliduntil.such:time.asfhe riamed.prod,uct(s)changes,the referenced
Quality Assurance documentation changes,orprovlsions cif the Code-thatrelate to the product change.. Acceptance of
this Evaluation Report, by the named client constitutes agreement to notlfy Robert Nieminen, P.E. If the product
changes or the referenced'Quality Assurance documentation changes. Trinity)ERD requires a complete review of this
Evaluation Iieport.relative to updated Gods requirements with each Code C-
ycle.
ADVERTISEMENT:The Evaluation Report.number preceded by-the words "TrinitylERD Evaluated" may be displayed'in
advertising literature. If any.portion of the.Evaluation Report is displayed;then it shall be done in its entirety.
INSPECTION:Upon request,a.copy of this.entlre.Evaluation Report shafi be.provided to the user by the manufacturer or
i
its distributors and shall be avallable for`fnspection at thejob site at the request of the BUilding Official.
i
This E.valuation,Report consists of pages 1 through 7.
Prepared-by:
a-;�°,.•moo=sp�e�"'='�s
Robert J.M.Nieminen P.E. Tha4csMpeseal.appearingwasauthorfumb
dbyRobertNlean,
P.E.on 101121201S.This does not se'rveas aoelectronkallydgned
do
�iOfidORCQIStrati0nlif0.$91�6,Fi0rid0DCAANF1983 mptent5�hed,sealedhardmpie$havebeer:transmktedtothe
1✓J�b.nrntria Product ApprovalAdininlsttatorand.whenamedcileht
CERTIFICATION OF INDEPENDENCE:
1. TrldltylERD does not have,nor does it intend to acquire.or will it.acquire,a financial Interest in any company manufacturing or
distributing products it evaluates, .
2. Trinity ERD is,not owned,operated or controlled by any company manufacturing.or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have-nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports.are being issued.
4. Robert Nieminen,P.E.does.not have,nor will acquire,a financial interest in any other entity involved In.the approval process of the
product.
5. This Isaa building code evaluation. Nelther'Trinityl ERD nor Robert N16minen, RE:are,in any way,the Designer of Record for any
project on which this:Evaluation.Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically forthat purpose.
TRINITY(ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub:Category: Uriderlayment
Compliance Statement: Roof Undedayments, as produced'by.Soprema,:have.demonstrated compliance-with the
"follow"Ing- sections of the Florida. Building 'Code through testing In accotdance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations/Conditions of Use.set forth herein.
2. STANDARDS:
Section .Property Standard. Year
1504.3.1 Wind Resistance FM 4474 2004
1507.2.4,1507.2.8, Physical Properties- ASTM D1970 2009
1507.2.9.2,1507.4.5.1,
1507.5.3,1507.7.3-
1507.11;2 Physical Propertles ASTM D6163 2000
1507.11.2 Physical Properties ASTM D6164 2005
1523.6.5.2.1 Physical Properties TAS 103 1995
TAS 110 Accelerated Weathering, TAS 110 2000
1507.3.3 Installation Practice F.RSA/TRI April 2012(04-12) 2012
3. REFERENCES:
Entily Examination Reference Date
ERD(TST6049) ASTM D1970/TAS 110 2968.05:04=2 05/14/2004
ERD(T5T6049). Physical Properties 2757.02.05 02%03/2005
ERD(TST6049) ASTM D1970/TA5110 2R74.03.05-2 05%17/2005
------ ----ERD�T5T6049)----..----WIhd-Resistance----....— -...__.-...— ---27--78.07;05-.. .-.......... . _. __...07/15/2005..._... — ------.
ERD-(TST6049): Wind Resistance 2779:11.05-R1 04%18/2007
ERD(TST6049) TAS 103'./TAS].10 573.20,11.07-2 12/02/2007
ERD(TST6049). ASTM D1970/TAS 110 S13190.02A941 04/01/2010
ERD(TST604% ASTM D1970/TAS 110 S31370.03.10-1-R! 04/07/2010.
ERD(TST6049). Physical:Properties/Tensile Adhesion 511159,05.10.111 D9/09/2010
50-:(TST6049) physical'Properties.%Tensile Adhesion S111%.05;09-112 10/05/•2010
ERD(TST6049.) ASTM D.1970 S37210.11.11 11/09/2011
ERD(TST6049)' ASTM D1970 S40540.02.13-1 02/19/2013
ERD(TST6049) Physical Properties/Ten0le Adhesion 543530.02:14-1 02/21/2014
ERD.(TST6049) Physical Propertles ITensile Adhesion: SOPC SC7645.02.15 02%13/2015
ERD(T5T6049) Accelerated Weathering SOPC-SC8520.14 04/17/2015
M-D(CER1592) HVHZ Comp)lanee 09r1005.02 11/04/2010
M-D(6ER1592). HVHZ CDmpliance 13-0530.02. 11/27/2014
i ICC-ES(EVL2396) 2012,2009.and 2006 IBC Compliance ESR-1524 10/01/2014
PRI(TST5878) Physical Properties SOP-064=02-01• 12/03/2013
Soprema,,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 05129/2015
UL,LLC(QUA9625) Quality Control Service Confirmation Exp.10/16/2017
4. PRODUCT DESCRIPTION:
4.1 Lastobodd TU HT is a self-adhering; non-woven polyester fabric surfaced, SBS modified bitumen roof
underiayment. '
4.2 Lastobond Shield is a self-adhering, .woven polyethylene surfaced, :SBS modified bitumen roof
underiayment available in two widths;36.and.45 inch.
4.3 RESISTO SA.SMOOTH PLY 40 is a self=adhering;woven polyethylene surfaced,SBS modified bitumen roof
underiayment;available in 3:3 ft:x 65 ft rolls:
Exterior,Research ond.0esign,LLC. Evaluation Report518010.:06.0949
Certlflcdte Of Aurhorkdtlori#9$03 FL2569.1111
Revision 8:10/12/2015
Paget of 7
TRINITY`ERD
4:4 Lastobond Shield W.is.a self-adhering, woven.poly6thylehe.surfaced, high temperature,.SBS modified
bitumen ro:of.underlayment.
4.5 Lastobond. Pro HT=N is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment availablein two widths;36 and 45 inch.
4.6 Lastobond Pro HT-S is.a seif-adhering, woven polyethylene surfaced, high temperature, SBS modified
bitumen roof.underlayment.
4.7 Lastobond 195 is a self-adhering; glass-mat reinforced, sand-surfaced, SBS modified bitumen roof
underlayment.
4:8 Lastobond Is a self-adhering, glass=mat reinforced; sand-surfaced, SBS modified bitumen roof
underlayment.
4.9 Lastobond Eco is a self-adhering; glass-mat reinforced,. sand-surfaced, SBS modified bitumen roof
underlayment.
4.10 Lastobond Smooth Seal HT-is.a:self-adhering,glasst-mat reinforced, film-surfaced,SBS modified bitumen
roof underlayment,
4.11 RESiSTO LB1236 is a self-adhering,.glass-mat- rei.lforcetf, sand surfaced, 'S8S modified bitumen roof
underlayment,with a 36=inch sheet width.
4:12 Prime5cu.rce G'rlp-Rite Eave 8t V6iley Protector Is a self-adhering,glass-mat reinforced,sand-surfaced,SBS
modified-bftumen roof underlayment,witha 36-Inch sheet width.
4.13 RESISTO L8.1244 is a self-adhering,:glass-mat relnfot.Ced, sand-surfaced,'SBS modified bitumen roof
under-layrnent,with a 44-inth sheet Width,-
4.14
idth,4.14 Colphene FR CR is-a self-adhering, fiberglass,reinforced, granule-surfaced, SBS modified bitumen roof
underlayment.
4.Ss"-"'"—Unilay"(ej-Ts a:mechanically attached, polyeste"r-reiiif`orced;granule=surfaced,SBS-modi led-bitiirnen-roof--'-~'-"
underlayment.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityiERD nor Robert Nieminen, P.E. are, in any way, the
Designer.9f Record for any project-on which:this..Mluation Report,or previous versions thereof, is/was
used for permitting or design guidance unless.retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the•HVHZ.
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 5oprema Roof Underlayments may be used with any prepared roof cover where the product Is specifically
referenced.within FBC approval documents. If not-listed,a request may be made to.the AHJ.for approval
based.on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop the.underiaymepts are follows;
LP
W.1,
Asphalt. Nail.-On Metal Foam•On. Wood Shakes:& Slate
Underlayment Shingles Tile: Tile Shingles
Yes
Lastobond TU HT Yes YesSee:5r5.1 Yes Yes Yes
Lastobond Shield/Pro HT-N/ yes No No No Yes Yes
RESISTO SA SMOOTH PLY 40
Lastobond 5hieid HT%Pro HT-S Yes No No Yes Yes Yes -
Lastobond/Lastobond 195 Yes No No No Yes Yes
Uterlor Research ond.Design;LLC: Evaluation Report 518010.06:09-R9
Certt lc6te of AOthorizatfod ABS03 FL2569-R11
Revision 9:10/12/201s
q Y Page 3 of 7
F)O
TRINITY I ERD
�i;,z.,F'3',1 ��-'ja ��� t tf ,Py d }e +yr,-: •d F7Y a ii�Ca., A�u'/$ P T rTy' l.1 •ti,+A,f' �'i���F�.r t',�' __`
t .:.:} }1�A}+.�� .,..,.:,f SF�Yi.,:Fr::r�,`F.a..t.ni�:3�"�',>1��. s.' •�..� .s��l?.._'.fU�i Y(FI::hW./4i.{inaE.
Asphalt Plait-0n Foam=On Metal Wood Shakes& Slate
Underlayment Shingles Tile The Shingles
Lastobond ECO /•RESISTO
LB1236,Grip-Rite Eave&Valley Yes No• ,No No Yes Yes
Protector/RESISTO LB1244
Lastobond Smooth Seal HT Yes No No Yes: Yes Yes
Colphene FR GR Yes Yes Yes No Yes Yes
See 5.5.1
.Unilay(e) Yes Yes. Yes No No No
Batten•Only See 5.5.1
5.5.1 "Foam-On Tile"is limited to use of the following adhesives unless tensile adhesion/longterm aging data
from an accredited testing laboratory is:provided,
Vnderlayment Adhesives)
Lastobond TU HT -3Jvl 2-Component;Foam Roof.Tile Adhesive.AH=160(FL6332)or Row Chemical TileBond'"Roof
Tile Adhesive(FL717)
Colphene FR GR 3M 2=Compdnent Foam Roof The Adhesive•AH-160(FL6332)
Urillay.{e) 3M 2=Component Foam Roof Tile Adhes14e AH-160.(FL6332)
5.6 Allowable substrates are noted below:-
.54.1. Direct-Bond to Deck:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SASMOOTRTLY'40,Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT,.Lastobond; Lastobond.195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eaue &
V— ey.Pr
.allotector,RE515T0 l Bf244•or 66bQnd 5mooth:Seal HT.applied to:
Plywood;ASTM 041 primed plywood;OSB;ASTM.D41:primed OSB;southern Yellow Pine;.ASTM D41
primed Southern Yellow Plnel ASTM D41 primed structural concrete.
Colphene FR-GR applied to:
Plywood;ASTM D41 primed plywood;ASTM'D41.primed structural concrete.
1
I Note:
➢ While not required over plywood,.OSB or Southern Yellow Pine substrates, soprema recommends
priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation.within '
24 hours;.
➢ Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to
1 installation of the self-.adhering underlayment.
5.6.2 Bond-to-Insulation:
I •
j Lastobond Shield, Lastobond Pro HT-N, RESISTO.SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT=S, Lastobond TU 11T; Lastobond;Lastobond 19.5, Lastobond.SCO, $ESISTD LB1286, Grip Rite E.ave &
Valley Protector,RESISTO L81244,Lastobond Smooth Seal.HT.or Colphene FR GR applied to:
Dens Deck Prime;SECUROCK.Gypsuin-Fiber Roof Board.
For installation under mechanically attached prepared roof coVer'ings, insulation shall be attached per
minimum requirements of the prepared:roof covering.manufacturer's Product Approval, For installations
under foam-on tale systems(Lastobond TU HT only),insulation attachment shall be.designed.,by a qualified
design professional and installed:based on testing of'the Insulation/underlayment system in accordance
with FM 4474,Appendix D o.r TAS 114,Appendix.
Exterior Research$nd.nesign,LLC. Evaluation ReportS18010:06.09-.R9
Cefriffnite of Authorraatfai,0505 FL2569-R11
Revision 9:10/12%2015
V 12V Page 4 of 7
"_J
TRINITY I ERS
5.6.3 Bond to Mechanically Attached Base.Layer:
Lastobond Shield,Lastobond Pro HT=N,.RES ISTO.$A SMOOTH PLY 40,Lastobond.8hleld HT, Lastobond Pro
HT-S, Lastobond TU-HT, Lastobond; Lastobond 155,1asto.bond ECO, RESISTO LB1236, Grip-Rite Eave &
Valley Protector,RESISTO LB1244,Lastobond Sm'ocih-Seal HT or.Colpliene FR GR applied to: -
ASTM D226,Type I or 1.1 felt;Sopra-G;,Modified Sopra=G':
For 'installations under mechanically attached prepared roof.coverings, base layer shall be attached per
minimum.codified requirements. For installations.under4.0am-on tile.systems (Lastobond TU HT only),
base layer shall.be attached in accordance With FRSA/TRI April 2012(0412).
5.6.4 Wind Resistance:for Underlayment Systems in Foam-On Tile Applications; FRSA/TRI April 2012 (04-12)
does.not address wind uplift'r'esistance.of all.underlayment.systems beneath foam-on tile systems,where
the underlayment forms part of'the-load=path..The-following.-wind uplift.limitations apply to underlayment
systems that are not addressed in FRSA/TRI April 2012-(04-12)and are used in foam-on'tile applications.
Maximum Design Pressure is theres.ult-oftestipg for wind load resistance based on allowable wind loads,
and reflects.they ultimate passing.pressure divided by 2 (the.2 to 1 margin of safety per FBC 1504.9 has
already been applied). Refer.to FBC 1509 for determinatl'on of.design wind pressures.
5.6.4.1 Maximum Desf&Pressure,=-45:0:risf.
Deck: Min.15%32-inch-plywood to meet project requirements to satisfaction of AHJ.
Primer.:: (OptionalJ;Elastocol Stick or Elastocol 600c
Underlaymentr 'LastobondTU HT or Colphene FR GR,:self-adhered..
5.6.4.2 Maximum Design"Pressure=•-67.5 Dsf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer E1astocol600c-
Underlayment: Lastobond TLY HT or ColpherieA GR,self-adhered.
- ---5:6:4:3•--Maximum•Design Pressure.=--60.0-psf:..._._........ -...__.._..-- - ...._._....... .._.._..................._.........._.........._... .._. .._. -
Deck:_ Mlh,29/32-inch plywood to.meet project requirements to satisfaction of AHJ.
Base Sheet:. Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin
caps.(FBC'1517.5.2)spaced 6-inch o.c.at the47inch laps and 6-Inch o.c.In three,equally
spaced rows in-the center of the:sheet.
Underlayment: Lastobon&TU HT'or Colphene PR 611,self-adhered
5.6:4:4 Maximum Design Pressure==50:0'psf.
Deck: Min.19/32-inch plywood to meet project requirements"to satisfaction of-AHJ.
Underlayment: Unilay(e)'mechanically attached with Soprafix P:olynier Batten Bar (PBB) or Soprafix
Metal-Batten Bar(MBB)with Soprema#.15-EL.fasteners spaced•6-inch o.c.within the 5-
inch wide; self-adhering side laps. End laps-are 6-inch Wide and sealed using either
heat-welding or hot-air welding technlques.
5.7 Exposure Limitations:
Lastobond, L"ast0bond 195,Lastobond E'go, Lastob0'nd'-smooth Seal HT, RE51STO LB1236, GHp Rite Eave &
Valley Protector or RESISTO LB1244 shall.not.b.e left-exposed for longer than,30-days after installation.
Lastobond.Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH.PLY 4Q, Lastobond Shield HT or Lastobond
Pro HT=S shall not be left exposed for longer than 9G.-days after installation.
Lastobond TU HT orcolphene FR GR or Unilay;(e)shall not be left exposed for longer than 180-days after
Installatlon..
Exterior.Research and:0eslgn,LLC: Evaluation ReportS19010.06.09-119
Ceraffleare of Authorftatton#9503 FL2569-1111
Revision 9:10%12/1015
Page 5 of7
TRINITY I ERD
6. INSTALLATION!
6:1 Soprema Roof Underlayments .shall'.be-installed 'in.accordance with.So.prema published installation
requirements subject to the limitations set forth in Section 5 herein and;the specifics noted below.
63' Re-fasten any loose decking panels,and check for protruding'nail'heads, Sweep the substrate:thoroughly
to remove any dust and debris prior to applicatlon, and prime.t4e substrate with Elastocol Stick.or
Elastocol 600c..(if applicable),
6:3 Lastdb6nd TU HT.Lastdbond Shield Lastobon'd•pro Ht--N ,RESISMSkSMOOTH PLY 40,Lastobond Shield
HT 'lastobond Pro HT=S Lastobond Lastobond 195 Lastobond Eco..Lastobond Smooth Seal HT RESIST.O
LB1236,Grip-Rite Eave&Valley Protector;.RESISTO LB3244�oecol`phene FR:GR;
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections
1507 for the type;of prepared roof covering to be Installed.
6.3.2 Non=TileAoMications:
While priming Moptional,Soprema.recommends priming with Elastocol Stick or Elastocol 600c if the final
roof cover,is n•ot.slated for installatiorrwithin,24flours,
Apply sheet:parallel to the roof edge. Roll out approXimately 10 ft of membrane and peel back the.first 3
ftof release film.
Adhere the exposed part" the.sabstrate:=and unroll the remaining membrane as far as possible.
Once the entire,length of:memb.rane,is in place, peel=off the release film diagonally while holding the
membrane tight: Firmly:roll the membrane into place tb.achleve a bond.
Horizontal seams should be:minitrium 34nches; configured to.shed water. Vertical seams should be 6-
inches and,staggered not less than 2=ft from vertical-seams in the,cdurse below. All over-granule end-laps-
shall
nd-lapsshall be sealed using:either heat-welding or hot:air weitlin.g tet�.nlques..
-- — When-insta11ing•at-slopes:-above 8::1.2;,Soprema=recommencls, back-nailing•in.the-overlap area•at-the•top-of---•- • -the sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlaymentinto 4 to 6 foot.lengths.Peel the release.paper and center.sheet
over valley or ridge. Drape and press sheet Into place,,working from the center of the valley or ridge in
each direction, For valleys,.-apply the.sheet.starting at the lowest point and work upward.
6.3.3 Tile Applications.f Lastobond TU HT or C6lohene FR.GR;onlv):
Reference is,made to FRSA/TRI April 2012-,(04n1!) 1051411.ation Manual and Table 1 herein, using the
Instructions noted above as a guideline.
For foam-on the applications,reference is made to'S.ection-5.6.4.herein forwind resistance limitations that
fall outside the.scope of FRSA/TRI April 2012(0442).
Tile shall be loaded and staged in a manner that prevents. tile slippage and/or damage to the
underlayrnent.
6.4 Unila e
I
6.4.1 Non-Tile Applications or Nail-On,.Battened Tile Abplications;.
Reference is made to Table 1 herein and FRSA/TRi April 2012(04-12)Installation Manual:(lf applicable).
Apply sheet parallel; to the roof edge and, starting at the eave with the selvedge-:edge upslope,
mechanically attach the 5-inch Wide selvedge-edge.to,the wood-deck with naiis:and tin caps or round cap-
nails.spaced M-inch o.c. .Apply the second course in a water-shedding manner with self-adhering side-
laps..Vigorous hand or motorized roller pressure Is.applied to the-self-adhering laps to ensure a watertight
applicatloh:
Vertical seams should be 64nches and'staggered,-not:less than:2-ft,from vertical seams in the course
below. All over-granule ends-laps-shall besealed using either heat-welding or hot airwelding techniques.
Exterior Research and.aesign,LLC: Evaluation Report 518010:06:09-R9
Certlfkkt8 of Aurhorfratfad M03 FL2569•R12
Revision 9i 10/12/2015
Page 6 of 7
TRINITY I ERD
Tile.(if applicable)shall be.loaded and staged in a rrianner that'preventstile:.slippage and/br damage to the
underlayment.
6.4.2 Foam-On Tile.Armlications
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual,Table 1 herein and Section 5.6.4.4
herein.
Apply sheet parallel to the roof edge and, starting at.the :eave: with the selvedge-edge upslope,
mechanically attach th'e.5 nch wide selvedge-edgeto the wood deck-Soprafix.Polymer 8atten,Bar(PBB)or
Soprafix Metal Batten Bar (MBB) with Soprema'#15=EL fasteners.spaced 6-inch o.c. Apply the second
course in a water-shedding manner,with self-adhering side-19p9: Vigorous.hand or motorized roller
pressure is applied to the self-adhering laps to.ensure.a.watertigh.t application.
Vertical seams should be 64hches-and staggered not,less.thah 2-ft from vertical seams in the course
below. Ail over-granule:end-laps shall be sealed usingeither heat-welding or hot air welding techniques.
Tile shall be loaded andstagedin a manner that prevents-tile slippage and/or damage to the
underlayment.
7. BUILDING PERMiT'R.EQ,UIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the Installation of
this product:
_
S. MANUFACiURINGPLANTS:
Contact the manufaeturer dr. the named QA entity for information on plants covered under Rule 61620-3 QA.
requirements.
9. QUAL)TYASSURANCE ENTITY:
---- --'—----"-UL","L'L'C' QUA9625�`(314)'578-3406;k.chancellor@us;uCcom -_...._._._.__..... ............... ............._... __... ._..._ .._.... ..-------. .... ._.. ..
-PIVD OF EVALUATION REPORT-
Exteripy.Research and Design,LLC: Evaluation Report 519010.06;09•R9
Cert[fitate of AuthodZ6006,0503 FL2569•RII
Revision 91 10/12/2015
Page 7 of 7