Loading...
HomeMy WebLinkAboutPDF0795-06WINDOW MFR. TO SUBMIT SHOP DWGS. TO SHOW FASTENING & ENGINEERING PER LATEST CODE. STUCCO RETURNS, TYP. EXTERIOR SEALANT, TYP EXTERIOR 0 WALL STUCCO & BANDS TEXTURED & PAINTED PER ELEVATIONS/PLANS. SOLID CONCRETE @ PERIMETER, FILLED CMU OR�POURED CONC., PER PLANS. INTERIOR 1 1/2" MIN. ANCHOR CAULK JOINT EMBEDMENT TYP. 1/4" MAX. SHIM, PROVIDE P.T. WOOD BUCKS AS NECESSARY, VERIFY W/ PRODUCT APPROVALS. VERIFY RETURNS, CASINGS, SILL, 1" (R-5) RIGID FOAM BOARD MATERIALS & PROFILES W/ OWNER. INSULATION CONT. TYP. AROUND PERIMETER. 5/8" DRYWALL ON 1X3 FURRING PROVIDE FLUID APPLIED SEAMLESS WATERPROOFSTRIPS @ 16" O.C., FINISHED & COATING/MEMBRANE AROUND ENTIRE OPENING. PAINTED PER FINISH SCHEDULE. MIN. 1X3 FURRING STRIPS TYP. IMPACT -RATED WINDOW, CONFIRM ALL CONT. AROUND PERIMETER. DETAILS & REQUIREMENTS W/ WINDOW MFR. 1 EXTERIOR WINDOW JAMB AT MASONRY WALL A-7 NOTE: AS APPLICABLE THE PRODUCT APPROVAL OR N.O.A. SCALE. 3" = Y-0" GOVERNS AS THE MIN. INSTALLATION REQUIREMENTS. SLIDING DOOR MFR. TO SUBMIT SHOP- DWGS. TO SHOW FASTENING & ENGINEERING PER LATEST CODE. EXTERIOR SEALANT, TYP.-\ EXTERIOR 11 WALL STUCCO & BANDS TEXTURED & PAINTED PER ELEVATIONS/PLANS, SOLID CONCRETE @ PERIMETER, FILLED CMU ORrOURED CONC., PER PLANS. INTERIOR 1 1/2" MIN. ANCHOR EMBEDMENT TYP. CAULK JOINT 1/4" MAX. SHIM, PROVIDE P.T. WOOD BUCKS AS - NECESSARY, VERIFY W/ PRODUCT APPROVALS. 1" (R-5) RIGID FOAM BOARD DRYWALL OR WOOD RETURNS INSULATION CONT. & CASINGS, AROUND PERIMETER, CONFIRM MATERIAL & PROFILES W/ OWNER. 5/8" DRYWALL ON 1X3 FURRING PROVIDE FLUID APPLIED SEAMLESS WATERPROOF STRIPS @ 16" O.C., FINISHED & COATING/MEMBRANE AROUND ENTIRE OPENING. PAINTED PER FINISH SCHEDULE. MIN. 1X3 FURRING STRIPS TYP. IMPACT -RATED SLIDING GLASS DOOR, CONFIRM CONT. AROUND PERIMETER. ALL DETAILS & REQUIREMENTS W/ DOOR MFR. 4 EXTERIOR SLIDING GLASS DOOR JAMB A_7 NOTE: AS APPLICABLE THE PRODUCT APPROVAL OR N.O.A. SCALE. -3" = 1'-0., GOVERNS AS THE MIN. INSTALLATION REQUIREMENTS. PRE -CAST LINTEL, SEE MAS OPENING & LINTEL SCHED WALL STUCCO & BANDS T & PAINTED PER ELEVATIOP SEE SCHEDULE _ B/ HEADER STUCCO RETURNS, TYP. EXTERIOR SEALANT, TYF EXTERIOR WINDOW MFR. TO SUBMIT SHOP DWGS. TO SHOW FASTENING & ENGINEERING PER LATEST CODE. EXTERIOR SEALANT, TYP. SLOPE SILL MIN. 1/8"� CONT. SILL FLASHING. �SSEE SCHEDULE -IV-T/ SILL WALL STUCCO & BANDS TEXTURED - & PAINTED PER ELEVATIONS/PLANS. MIN. 4" H. POURED CONC. SILL W/- (1) #5 CONT. (MAX. 8" H. ALLOWED) FIELD VERIFY FINAL SILL HEIGHT. MASON TO PROVIDE CAVITY CAPS. - 11 1" (R-5) RIGID FOAM BOARD INSULATION CONT. 5/8" DRYWALL ON 1X3 FURRING STRIPS @ 16" O.C., FINISHED & PAINTED PER FINISH SCHEDULE. 1/4" MAX. SHIM, PROVIDE P.T. WOOD BUCKS AS NECESSARY, VERIFY W/ PRODUCT APPROVALS. MIN. 1X3 FURRING STRIPS CONT. AROUND PERIMETER. VERIFY RETURNS, CASINGS, MATERIALS & PROFILES W/ OWNER. TYP. AROUND PERIMETER. CAULK JOINT INTERIOR 1/4" MAX. SHIM, PROVIDE P.T. WOOD BUCKS AS NECESSARY, VERIFY W/ PRODUCT APPROVALS. CAULK JOINT WINDOW SILL TYP. VERIFY W/ OWNER. CAULK JOINT MIN. 1X3 FURRING STRIPS CONT. AROUND PERIMETER. 5/8" DRYWALL ON 1X3 FURRING STRIPS @ 16" O.C., FINISHED & PAINTED PER FINISH SCHEDULE. 1" (R-5) RIGID FOAM BOARD INSULATION CONT. TYP. IMPACT -RATED WINDOW, CONFIRM ALL PROVIDE FLUID APPLIED SEAMLESS WATERPROOF DETAILS & REQUIREMENTS W/ WINDOW MFR.I COATING/MEMBRANE AROUND ENTIRE OPENING. WINDOW HEAD/SILL DETAIL AT MASONRY WALL A_7 NOTE: AS APPLICABLE THE PRODUCT APPROVAL OR N.O.A. SCALE. 11,/2" _ - GOVERNS AS THE MIN. INSTALLATION REQUIREMENTS. DOOR MFR. TO SUBMIT SHOP - DWGS. TO SHOW FASTENING & ENGINEERING PER LATEST CODE. STUCCO RETURNS, TYP. EXTERIOR SEALANT, TYP EXTERIOR 0 WALL STUCCO & BANDS TEXTURED & PAINTED PER ELEVATIONS/PLANS. SOLID CONCRETE @ PERIMETER, FILLED CMU OR �OUREID CONC., PER PLANS. INTERIOR 0 THRESHOLD SET 1 1/2" MIN—. ANCHOR IN SEALANT, TYP. EMBEDMENT TYP. CAULK JOINT 1/4" MAX. SHIM, PROVIDE P.T. WOOD BUCKS AS NECESSARY, VERIFY W/ PRODUCT APPROVALS. L 1" (R-5) RIGID FOAM BOARD WOOD RETURNS & CASINGS, INSULATION CONT. TYP. AROUND PERIMETER. CONFIRM MATERIAL & PROFILES W/ OWNER. 5/8" DRYWALL ON 1X3 FURRING PROVIDE FLUID APPLIED SEAMLESS WATERPROOF STRIPS @ 16" O.C., FINISHED & COATING/MEMBRANE AROUND ENTIRE OPENING. PAINTED PER FINISH SCHEDULE. MIN. 1X3 FURRING STRIPS TYP. IMPACT -RATED FRENCH DOOR, CONFIRM CONT. AROUND PERIMETER. ALL DETAILS & REQUIREMENTS W/ DOOR MFR. 2 EXTERIOR DOOR JAMB AT MASONRY WALL A-7 NOTE: AS APPLICABLE THE PRODUCT APPROVAL OR N.O.A. SCALE. 3" = Y-0" GOVERNS AS THE MIN. INSTALLATION REQUIREMENTS. EXTERIOR 5/8" TH. STUCCO RETURNS, TYP. • EXT. SEALANT, TYP. DOOR GASKET PER DOOR MFR. WALL STUCCO & BANDS TEXTURED & PAINTED PER ELEVATIONS/PLANS. SOLID CONCRETE @ PERIMETER, FILLED CMU OR POURED CONC., PER PLANS. I 3" X 3" X 1/4" GALV. WASHERS W/ 1/2"O X 4" L. EXP. ANCHORS OR PER PRODUCT APPROVALS. (SPACE EQUALLY, 16" O.C. MAX. AND MAX. 6" FROM ENDS). GARAGE DOOR MFR. TO SUBMIT MIN. 2X8 P.T. WD. BUCK, FULL HT. SHOP DWGS. TO SHOW FASTENING MOUNTING CLIPS & ANCHORS ENGINEERING PER LATEST CODE. PER DOOR SHOP DRAWINGS. 3 GARAGE DOOR JAMB DETAIL A-7 NOTE: AS APPLICABLE THE PRODUCT APPROVAL OR N.O.A. SCALE. 3" = 1'-0" -01 GOVERNS AS THE MIN. INSTALLATION REQUIREMENTS. PRE -CAST LINTEL, SEE MAS( OPENING & LINTEL SCHEDL WALL STUCCO & BANDS TE & PAINTED PER ELEVATION SEE SCHEDULE_ _ B/ HEADER HEADER EXTERIOR SEALANT, TYP. SLIDING DOOR MFR. TO SUBMIT SHOP DWGS. TO SHOW FASTENING & ENGINEERING PER LATEST CODE. I 1" (R-5) RIGID FOAM BOARD INSULATION CONT. 5/8" DRYWALL ON 1X3 FURRING STRIPS @ 16" O.C., FINISHED & PAINTED PER FINISH SCHEDULE. 1/4" MAX. SHIM, PROVIDE P.T. WOOD BUCKS AS NECESSARY, VERIFY W/ PRODUCT APPROVALS. MIN. 1X3 FURRING STRIPS CONT. AROUND PERIMETER. VERIFY RETURNS, CASINGS, MATERIALS & PROFILES W/ OWNER. TYP. AROUND PERIMETER. CAULK JOINT INTERIOR DOOR TRACK SET IN CONT. FINISH FLOORING, PROVIDE CONT. BEAD OF SEALANT, TYP. RISER ACCORDINGLY. VERIFY W/ FASTEN PER SHOP DRAWINGS. OWNER & FLOORING CONTRACTOR, MAX. 1/4" NON -SHRINK GROUT. PROVIDE BUILT -OUT STUCCOe a 3/4" TO 1 1/2" D. X ±8" W. AS REQ'D. AT THRESHOLDS.TDOOR TRACK RECESS CONFIRM WIDTH & DEPTH W/ DOOR MFR., OWNER, & FLOORING CONTRACTOR. TYP. IMPACT -RATED SLIDING GLASS DOOR, CONFIRM PROVIDE FLUID APPLIED SEAMLESS WATERPROOF ALL DETAILS & REQUIREMENTS W/ DOOR MFR. COATING/MEMBRANE AROUND ENTIRE OPENING. 8 TYPICAL SLIDING GLASS DOOR HEAD17HRESHOLD A-7 NOTE: AS APPLICABLE THE PRODUCT APPROVAL OR N.O.A. SCALE. 1112" = V-0" GOVERNS AS THE MIN. INSTALLATION REQUIREMENTS. CEILING FRAMING, SEE CEILING PLANS FOR DETAILS. ,j, SEESCHEDULE 'r CEILING HEIGHT `- BATT INSUL. TYP. THROUGHOUT CEILING 5/8" DRYWALL, PAINTED CONFIRM FINISH/TEXTURE. 25 GA. TOP TRACK 3-5/8" MTL. STUDS 16" O.C., 25 GA. 5/8" GYP. BD. BOTH SIDES, CONFIRM FINISH/TEXTURE, PAINTED, TYP. SEE FINISH SCHEDULE PROVIDE (R-11) 3-1/2" BATT INS. WHERE SHOWN, ON PLANS, FULL HEIGHT. IL25 GA. BOTTOM TRACK BASE PER FINISH SCHEDULE. -0FIN. PER FINISH SCHEDULE. `� FIN. FLOOR TYP. INTERIOR NON-BEARING 9 METAL STUD WALL SECTION ALUMINUM STANDING SEAM — ROOF PANELS, 20 GA. TYP. SEE ELEVATIONS FOR SPECS. SELF -ADHERING UNDERLAYMENT PROVIDE SUBMITTALS. 5/8" CDX PLYWOOD SHEATHING. - HURRICANE ANCHORS PER ROOF FRAMING PLAN. 38'_10"(46.85)) T/ WALL ALUM. DRIP FLASHING PER ROOF PANEL MFR. 1x4 DRIP & 2x8 FASCIA HARDIE BOARD, PAINTED. 5/8" STUCCO SOFFIT, OVER HI -RIB LATH, PAINTED. SOFFIT VENTS 6" X 14" AT 8'-0" O.C. OR 2" CONT. VENT PROVIDE SUBMITTALS. FOAM/STUCCO OUTLOOKER. 5/8" STUCCO, PAINTED. CONFIRM FINISH/TEXTURE STD. 8" MASONRY WALL W/ DUR-O-WALL HORIZ. REINF. EVERY OTHER COURSE. #6 DOWELS @ EACH FILLED CELL PER STRUCTURAL PLANS PROVIDE STD. 90° ACI HOOK. LAP 48 BAR DIAMETERS MIN. STUCCO BAND, TYP. SEE DETAIL. %,� X25' 6 (3.352) r 1 FLOOR F.F. 3rd X24'-4" T/ BOND BEAM REFER TO STRUCTURAL— DRAWINGS FOR BOND BEAM LOCATIONS & DETAILS. 5/8" STUCCO, PAINTED. CONFIRM FINISH/TEXTURE STD. 8" MASONRY WALL W/ DUR-O-WALL HORIZ. REI NF. EVERY OTHER COURSE. #6 DOWELS @ EACH FILLED CELL PER STRUCTURAL PLANS. PROVIDE STD. 90° ACI HOOK. LAP 48 BAR DIAMETERS MIN. STUCCO BAND, TYP. SEE DETAIL. 12' 2�" (20.18) FLOOR F.F. 11'-3-3" T/ TIE BEAM 9'4' (17.3_5) Z� B/ TIE BEAM (B/ LOWEST BEAM) REFER TO STRUCTURAL DRAWINGS FOR CONC. TIE BEAM LOCATIONS & DETAILS. 5/8" STUCCO, PAINTED. CONFIRM FINISH/TEXTURE J J 18 S-6 w m BREAKAWAY WALL SEE SEE DETAIL 18/S-6. 0'-0-0"(&02) 1st FLOOR F.F. 4'7_11 GRADE BEAM STUCCO EXTENDS MIN. 8" - BELOW FINAL GRADE. d W REVISIONS: No: DATE COMMENTS O Q2 06-19-19 BLDG, DEPT. REV. A3 07-10-20 OWNER REV. p Z W F U W F- I U Q 12 5 �/' 0 Q W LL F MIN. 5.25" TH. (R-20) 0 SPRAY -FOAM INSULATION � Q THROUGHOUT ENTIRE ROOF. N PRE-ENGINEERED WOOD c� TRUSSES @ 24" O.C. O SEE TRUSS ENGINEERING I FOR LAYOUT AND DETAILS. 5/8" DRYWALL CEILING, TYP. O CONFIRM FINISH/TEXTURE. REFER TO STRUCTURAL •.J DRAWINGS FOR BOND BEAM LOCATIONS & DETAILS. V� Q E° 1/2" DRYWALL, PAINTED ON 1 X 3 P.T. WD. FURRING @ 16" O.C. o E - OVER CONT. 3/4" (R-5) RIGID BOARD 4ft-ftZ INSULATION (TAPE ALL SEAMS). �•. (n cc I CONFIRM FINISH/TEXTURE V W/ OWNER, TYP. r , 1 . � U � 1 X 3 P.T. WD NAILER, TYP. O 4` 0 SEE FINISH SCHEDULE FOR BASE & FLOORING.r'j „r [ � I it 8" HOLLOW CORE PANEL W/ V� �V �/ Lt. 3" CONC. TOPPING. SEE SHOP DRAWINGS & ENGINEERING FOR LAYOUT AND DETAILS. � , f"1 0 00 �'•. a moi. 0 U --------- - 2;;� I V) 0 3 1/2" (R-11) BATT. INSUL., TYP. W� 5/8" DRYWALL, PAINTED ON SUSPENDED FRAMING. SEE 0 CEILING PLANS FOR DETAILS. Z 1 X 3 P.T. WD NAILER, TYP. W CO J J 1/2" DRYWALL, PAINTED ON Q 1 X 3 P.T. WD. FURRING @ 16" O.C. N I OVER CONT. 3/4" (R-5) RIGID BOARD N In INSULATION (TAPE ALL SEAMS). W CONFIRM FINISH/TEXTURE dam' 00 W W/ OWNER, TYP. 00 N I W LF 1 X 3 P.T. WD NAILER, TYP. Q 0 W SEE FINISH SCHEDULE FOR v) k H BASE & FLOORING. ��+\Nm 8" HOLLOW CORE PANEL W/ 3" CONC. TOPPING. SEE SHOP DRAWINGS & ENGINEERING d FOR LAYOUT AND DETAILS. m ae U All CD d 3 1/2" (R-11) BATT. INSUL., TYP. o W 11�5/8" DRYWALL, PAINTED ON �� Q SUSPENDED FRAMING. SEE 0 CEILING PLANS FOR DETAILS. �� L N 1 X 3 P.T. WD NAILER, TYP. on ® z �U N aj -a Z c: O > 1/2" DRYWALL, PAINTED ON ' L 1 X 3 P.T. WD. FURRING @ 16" O.C. o 0U OVER CONT. 3/4" (R-5) RIGID BOARD �: W INSULATION (TAPE ALL SEAMS). 000 ( F CONFIRM FINISH/TEXTURE W/ OWNER, TYP. N U 1 X 3 P.T. WD NAILER, TYP. Q SEE FINISH SCHEDULE FOR --- -.a o BASE & FLOORING. w Q W ! 3 C✓ C)L g 0 L0l,� } Zf Q W REFER TO FOUNDATION DRAWINGS t (SHEETS S-1, S-2, S-3) BY CSM ENGINEERING, a FOR FOUNDATION, GRADE BEAM, SLAB & �\ e: �' O AUGER PILE REQUIREMENTS &DETAILS. ` � a W Job Number: I Drawn By: rss Date: 03-20-19 Sheet Number Z ALL ELEVATIONS SHOWN RIOR WALL SECTION REFERENCED TO NAVD-88. A 7 TYPICAL EXTE 0 __ o DETAILS THIS SHEET. A-7 'S WINDOW WIDTH WOOD CASINGS, TYP. CONFIRM MATERIAL & 3" MAX. 3" MAX. CAULK PROFILES W/ OWNER. SHIM GAP 5/8" GYP. BD., - - - PAINTED. PRE -HUNG -v ' WOOD JAMB CAULK M TYPICAL ATTACHMENT: WOOD STOP u? 1/4" X 3 1/2" TAPCONS @ = I I 12" O.C. THRU P.T. 1X WOOD p ( BUCK W/ MIN. 1 1/2" CONC. z ( EMBED. 3" MAX. FROM ENDS. CAU LK ---�� I I SEE DETAILS DOOR R.O. 3-5/8" X 25 GA. A-7 THIS SHEET. METAL STUDS @ 16" O.C. VERIFY W/ MFR. `" 2 X 4 WOOD BLOCKING L — J PROVIDE 5" DOOR RETURNS WHERE POSSIBLE TYP., 4" MIN. REQUIRED. FINAL FASTENING SHALL BE PER THE WINDOW MFR. PRODUCT APPROVALS OR N.O.A. AS APPLICABLE. 5 INTERIOR DOOR JAMB 6 TYP. WINDOW ATTACHMENT A-7 SCALE. 3" = Y-0" A-7 N.T.S. PRE -CAST LINTEL, SEE MAS( OPENING & LINTEL SCHEDL WALL STUCCO & BANDS TE & PAINTED PER ELEVATION SEE SCHEDULE_ _ B/ HEADER HEADER EXTERIOR SEALANT, TYP. SLIDING DOOR MFR. TO SUBMIT SHOP DWGS. TO SHOW FASTENING & ENGINEERING PER LATEST CODE. I 1" (R-5) RIGID FOAM BOARD INSULATION CONT. 5/8" DRYWALL ON 1X3 FURRING STRIPS @ 16" O.C., FINISHED & PAINTED PER FINISH SCHEDULE. 1/4" MAX. SHIM, PROVIDE P.T. WOOD BUCKS AS NECESSARY, VERIFY W/ PRODUCT APPROVALS. MIN. 1X3 FURRING STRIPS CONT. AROUND PERIMETER. VERIFY RETURNS, CASINGS, MATERIALS & PROFILES W/ OWNER. TYP. AROUND PERIMETER. CAULK JOINT INTERIOR DOOR TRACK SET IN CONT. FINISH FLOORING, PROVIDE CONT. BEAD OF SEALANT, TYP. RISER ACCORDINGLY. VERIFY W/ FASTEN PER SHOP DRAWINGS. OWNER & FLOORING CONTRACTOR, MAX. 1/4" NON -SHRINK GROUT. PROVIDE BUILT -OUT STUCCOe a 3/4" TO 1 1/2" D. X ±8" W. AS REQ'D. AT THRESHOLDS.TDOOR TRACK RECESS CONFIRM WIDTH & DEPTH W/ DOOR MFR., OWNER, & FLOORING CONTRACTOR. TYP. IMPACT -RATED SLIDING GLASS DOOR, CONFIRM PROVIDE FLUID APPLIED SEAMLESS WATERPROOF ALL DETAILS & REQUIREMENTS W/ DOOR MFR. COATING/MEMBRANE AROUND ENTIRE OPENING. 8 TYPICAL SLIDING GLASS DOOR HEAD17HRESHOLD A-7 NOTE: AS APPLICABLE THE PRODUCT APPROVAL OR N.O.A. SCALE. 1112" = V-0" GOVERNS AS THE MIN. INSTALLATION REQUIREMENTS. CEILING FRAMING, SEE CEILING PLANS FOR DETAILS. ,j, SEESCHEDULE 'r CEILING HEIGHT `- BATT INSUL. TYP. THROUGHOUT CEILING 5/8" DRYWALL, PAINTED CONFIRM FINISH/TEXTURE. 25 GA. TOP TRACK 3-5/8" MTL. STUDS 16" O.C., 25 GA. 5/8" GYP. BD. BOTH SIDES, CONFIRM FINISH/TEXTURE, PAINTED, TYP. SEE FINISH SCHEDULE PROVIDE (R-11) 3-1/2" BATT INS. WHERE SHOWN, ON PLANS, FULL HEIGHT. IL25 GA. BOTTOM TRACK BASE PER FINISH SCHEDULE. -0FIN. PER FINISH SCHEDULE. `� FIN. FLOOR TYP. INTERIOR NON-BEARING 9 METAL STUD WALL SECTION ALUMINUM STANDING SEAM — ROOF PANELS, 20 GA. TYP. SEE ELEVATIONS FOR SPECS. SELF -ADHERING UNDERLAYMENT PROVIDE SUBMITTALS. 5/8" CDX PLYWOOD SHEATHING. - HURRICANE ANCHORS PER ROOF FRAMING PLAN. 38'_10"(46.85)) T/ WALL ALUM. DRIP FLASHING PER ROOF PANEL MFR. 1x4 DRIP & 2x8 FASCIA HARDIE BOARD, PAINTED. 5/8" STUCCO SOFFIT, OVER HI -RIB LATH, PAINTED. SOFFIT VENTS 6" X 14" AT 8'-0" O.C. OR 2" CONT. VENT PROVIDE SUBMITTALS. FOAM/STUCCO OUTLOOKER. 5/8" STUCCO, PAINTED. CONFIRM FINISH/TEXTURE STD. 8" MASONRY WALL W/ DUR-O-WALL HORIZ. REINF. EVERY OTHER COURSE. #6 DOWELS @ EACH FILLED CELL PER STRUCTURAL PLANS PROVIDE STD. 90° ACI HOOK. LAP 48 BAR DIAMETERS MIN. STUCCO BAND, TYP. SEE DETAIL. %,� X25' 6 (3.352) r 1 FLOOR F.F. 3rd X24'-4" T/ BOND BEAM REFER TO STRUCTURAL— DRAWINGS FOR BOND BEAM LOCATIONS & DETAILS. 5/8" STUCCO, PAINTED. CONFIRM FINISH/TEXTURE STD. 8" MASONRY WALL W/ DUR-O-WALL HORIZ. REI NF. EVERY OTHER COURSE. #6 DOWELS @ EACH FILLED CELL PER STRUCTURAL PLANS. PROVIDE STD. 90° ACI HOOK. LAP 48 BAR DIAMETERS MIN. STUCCO BAND, TYP. SEE DETAIL. 12' 2�" (20.18) FLOOR F.F. 11'-3-3" T/ TIE BEAM 9'4' (17.3_5) Z� B/ TIE BEAM (B/ LOWEST BEAM) REFER TO STRUCTURAL DRAWINGS FOR CONC. TIE BEAM LOCATIONS & DETAILS. 5/8" STUCCO, PAINTED. CONFIRM FINISH/TEXTURE J J 18 S-6 w m BREAKAWAY WALL SEE SEE DETAIL 18/S-6. 0'-0-0"(&02) 1st FLOOR F.F. 4'7_11 GRADE BEAM STUCCO EXTENDS MIN. 8" - BELOW FINAL GRADE. d W REVISIONS: No: DATE COMMENTS O Q2 06-19-19 BLDG, DEPT. REV. A3 07-10-20 OWNER REV. p Z W F U W F- I U Q 12 5 �/' 0 Q W LL F MIN. 5.25" TH. (R-20) 0 SPRAY -FOAM INSULATION � Q THROUGHOUT ENTIRE ROOF. N PRE-ENGINEERED WOOD c� TRUSSES @ 24" O.C. O SEE TRUSS ENGINEERING I FOR LAYOUT AND DETAILS. 5/8" DRYWALL CEILING, TYP. O CONFIRM FINISH/TEXTURE. REFER TO STRUCTURAL •.J DRAWINGS FOR BOND BEAM LOCATIONS & DETAILS. V� Q E° 1/2" DRYWALL, PAINTED ON 1 X 3 P.T. WD. FURRING @ 16" O.C. o E - OVER CONT. 3/4" (R-5) RIGID BOARD 4ft-ftZ INSULATION (TAPE ALL SEAMS). �•. (n cc I CONFIRM FINISH/TEXTURE V W/ OWNER, TYP. r , 1 . � U � 1 X 3 P.T. WD NAILER, TYP. O 4` 0 SEE FINISH SCHEDULE FOR BASE & FLOORING.r'j „r [ � I it 8" HOLLOW CORE PANEL W/ V� �V �/ Lt. 3" CONC. TOPPING. SEE SHOP DRAWINGS & ENGINEERING FOR LAYOUT AND DETAILS. � , f"1 0 00 �'•. a moi. 0 U --------- - 2;;� I V) 0 3 1/2" (R-11) BATT. INSUL., TYP. W� 5/8" DRYWALL, PAINTED ON SUSPENDED FRAMING. SEE 0 CEILING PLANS FOR DETAILS. Z 1 X 3 P.T. WD NAILER, TYP. W CO J J 1/2" DRYWALL, PAINTED ON Q 1 X 3 P.T. WD. FURRING @ 16" O.C. N I OVER CONT. 3/4" (R-5) RIGID BOARD N In INSULATION (TAPE ALL SEAMS). W CONFIRM FINISH/TEXTURE dam' 00 W W/ OWNER, TYP. 00 N I W LF 1 X 3 P.T. WD NAILER, TYP. Q 0 W SEE FINISH SCHEDULE FOR v) k H BASE & FLOORING. ��+\Nm 8" HOLLOW CORE PANEL W/ 3" CONC. TOPPING. SEE SHOP DRAWINGS & ENGINEERING d FOR LAYOUT AND DETAILS. m ae U All CD d 3 1/2" (R-11) BATT. INSUL., TYP. o W 11�5/8" DRYWALL, PAINTED ON �� Q SUSPENDED FRAMING. SEE 0 CEILING PLANS FOR DETAILS. �� L N 1 X 3 P.T. WD NAILER, TYP. on ® z �U N aj -a Z c: O > 1/2" DRYWALL, PAINTED ON ' L 1 X 3 P.T. WD. FURRING @ 16" O.C. o 0U OVER CONT. 3/4" (R-5) RIGID BOARD �: W INSULATION (TAPE ALL SEAMS). 000 ( F CONFIRM FINISH/TEXTURE W/ OWNER, TYP. N U 1 X 3 P.T. WD NAILER, TYP. Q SEE FINISH SCHEDULE FOR --- -.a o BASE & FLOORING. w Q W ! 3 C✓ C)L g 0 L0l,� } Zf Q W REFER TO FOUNDATION DRAWINGS t (SHEETS S-1, S-2, S-3) BY CSM ENGINEERING, a FOR FOUNDATION, GRADE BEAM, SLAB & �\ e: �' O AUGER PILE REQUIREMENTS &DETAILS. ` � a W Job Number: I Drawn By: rss Date: 03-20-19 Sheet Number Z ALL ELEVATIONS SHOWN RIOR WALL SECTION REFERENCED TO NAVD-88. A 7 TYPICAL EXTE 0 __ o