HomeMy WebLinkAboutRevisions; Energy Calcs & Manual J Forms( OFFICE USE ONLY:
DATE FILED: • 12- I /
REVISION FEE: IM. !
1. LOCATION/SITE
ADDRESS:
I5o -oayq
PERMIT #
RECEIPT #
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGEWA AVENUE
FORT PIERCE, FL 34992-5652
(772) 462-1553 FAX (772) 462-1578
APPLICATION FOR BUILDING PERMIT REVI.�.�
PROJECT INFORMATION`"
A01r,.
2. DETAILED DESCRIPTIPMOF PROJECT
REVISIONS:
3.
4.
5.
CONTRACTOR INFORMATION:
STATE'of FL REG./CERT. #: _
BUSINESS NAME: _
QUALIFIERS NAME: _
ADDRESS•
ST. LUCIE COUNTY CERT. #:
CITY: STATE: ZIP:
PHONE (DAYTE%IE): FAX:
OWNER/BUILDER INFORMATION:
NAME:
ADDRESS:
CITY:
PHONE:
ARCHITECT/ENGINEER INFORMATION:
STATE:
FAX:
ZIP:
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE (DAYTIME): FAX:
". Revised 07/22/2014
REVISION
0
FORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: EMMONS HOBBY RM WITHOUT SITTNG
Builder Name
,IN (';"�
J " l)
Street 526 CAMPBELL ROAD
City, State, Zip: FORT PIERCE. FL,
Permit Office:r!
Permit Number
Owner
Jurisdiction:
Design Location: FL, Fort Pierce
�,; a
1. New construction or e)Mng New (From Plans)
9. Wall Types (3070.7 sgfL)
Insulation Area
2. Single family or multiple family Single-family
a Concrete Block- Fad Insul, Ederior
R=4.1 3070.70 ftz
b. N/A
R= ft2
3. Number of units, if multiple family 1
c. N/A
R= fP
4. Number of Bedrooms 4
d. N/A
R= W
10. Ceiling Types (3515.0 sgfL)
Insulation Area
5. Is this aworst case? No
a Roof Deck (Unvented)
R=20.0 3515.00 ft
6. Conditioned floor area above grade (ftj 3515
b. N/A
R= ft2
Conditioned floor area below grade (ft) 0
r- WA
R= ft2
11. Ducts
R ft
7. Windows(501.0 sgft.) Description Area
a Sup: Attic, Ret Attic, AH: Attic
6 175
a U-Factor. Sgt, U=0.79 501.00112
b. Sup: Attic, Ret Attic, AH: Attic
6 150
SHGC: SHGG0.49
b. U-Factor. NIA fe
12. Cooing systems
kBtulhr Efficiency
SHGC;
SHGC-.
a Central Unit
42.0 SEER:16.00
c. N/A
b. Central Unit
a Central Unit
18.0 SEER:16.00
12.0 SEER:20.50
SHGC:
13. Heating systems
kBtulhr Efficiency
d. U-Factor. N/A ftZ
a Electric Strip Heat
27.0 COP:1.00
SHGC:
b. Electric Strip Heat
17.0 COP:1.00
Area Weighted Average Overhang Depth. 8.818 fL
a Electric Heat Pump
17.0 HSPF:10.00
Area Weighted Average SHGC: 0A90
14. Hot water systems
a Electric
Cap: 40 gallons
8. Floor Types (3515.0 sgfL) Insulation Area
EF: 0.920
a Slab -On -Grade Edge Insulation R=0.0 3515.00 f?
b. Conservation features
b. N/A R= ft2
None
m N/A R= fP
15. Credits
Pstat
Glass/Floor Area: 0.143 Total Proposed Modified Loads: 44.69
/�'1
PASS
SS
Total Standard Reference Loads: 64.07
1 hereby certify that the plans and specifications covered by
Review of the plans and
-VMS
this calculation are in compliance with the Florida Energy
specifications covered by this
o
, _ ; p
Code.
calculation indicates compliance
Q91
with the Florida Energy Code.
PREPARED
Before construction is completed
DATE: -
this building will be inspected for
compliance with Section 553.908
* e
hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy C e.
G'OD WE
OWNER/AGENT-
BUILDING OFFICIAL:
DATE: -
DATE:
11130=15 7:29 PM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Sofiware Page 1 of 6
PROJECT
Title:
EMMONS HOBBY RM WITH Bedrooms: 4
Address Type: Street Address
Building Type:
User
Conditioned Area: 3515
Lot #
Total Stories 1
Block/SubDivision:
Owner
# of Units:
1
Worst Case: No
PlatBoak
Rotate Angle: 0
Street 526 CAMPBELL ROAD
Builder Name:
Cross Ventilation:
County. St. Lucie
Permit Office:
Whole House Fan:
City, State, Zip: FORT PIERCE,
Jurisdiction:
FL.
FamllyType:
Single -fatuity
New/Edsting:
New (From Plans)
Comment:
CLIMATE
IECC Design Temp
Int Design Temp Heating Design Daily Temp
Design Location
TMY Site Zone 97.5 % 2.6 %
Winter
Summer Degree Days Moisture Range
FL, Fort Pierce
Fl.ST LUCIE CO INTL 2 39 90
70
75 722 62 Low
BLOCKS
Number
Name
Area Volume
1
Blocki
2200 19800
2
Block2
809 7281
3
Block33
506 4554
SPACES
Number
Name
Area Volume IGtchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
MAIN
2200 19800 Yes 4
3
1 Yes Yes Yes
2
MASTER
809 7281 No 2
1
1 Yes Yes Yes
3
HOBBY
506 4554 No 0
0
1 Yes Yes Yes
FLOORS
#
Floor -Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value Tile Wood Carpet
1-Slab-On-Grade Edge Insulation MAIN 181 ft 0
2200 ft2
— 1 0 0
2 Slab -On -Grade Edge Insulation MASTER 64 ft 0
809 ft=
— 1 0 0
3 Slab
-On -Grade Edge insulation HOBBY 67 ft 0
506 ft'
— 1 0 0
ROOF
Roof Gable Roof
Solar
SA Emdtt Emitt Deck Pitch
#
Type
Materials Area Area Color
Absor.
Tested Tested Insul- (deg)
1
Hip
Metal 3807W 0f? White
0.3
No 0.9 No 20 22.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 In)
Area
RBS IRCC
1
Full attic
Unvented 0
3515 ft2
N N
11/30/2015 7:29 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6
1
2
3
4
5
6
7
8
9
10
11
N
E
S
W
N
E
S
W
N
E
S
CEILING
Ceiling Type Space
R Value
Under Attic (Unvented) MAIN
20
Under Attic (Unvented) MASTER
20
Under Attic (Unvented) HOBBY
20
WALLS
Anacnt
T
nit Moe Space
Cvity
RAW-
Width
Ff I
Exterior
Concrete Block- EA Insul MAIN
4.09999
43
Exterior
Concrete Block- Ext Insul MAIN
4.09999
67
Exterior
Concrete Block - Ext Insul MAIN
4.09999
39
Exterior
Concrete Block- Ext Insul MAIN
4.09999
42
Exterior
Concrete Block- F-A Insul MASTER
4.09999
15
Exterior
Concrete Block - Ext Insul MASTER
4.09999
6
Exterior
Concrete Block - Ext Insul MASTER
4.09999
19
Exterior
Concrete Block - Ext Insul MASTER
4.09999
42
Exterior
Concrete Block- EA Insul HOBBY
4.1
22
Exterior
Concrete Block- Ext Insul HOBBY
4.1
23
Exterior
Concrete Block - Ext Insul HOBBY
4.09999
22
DOORS
Area
Framing Frac
Truss Ty
2200 ft2
0.11
Wood
809 ft2
0.11
Wood
506 ft2
0.11
Wood
Height
Et In
Area
Sheathing Framing
R�(aiue �^
Solar
Ahcnr
Below
rrad j
9 4
401.3 W
0
0
0.75
0
9 4
53Z0 ftZ
0
0
0.75
0
9 4
364.0 ft2
0
0
0.75
0
9 4
392.0 ft2
0
0
0.75
0
9 4
140.0 ft2
0
0
0.75
0
9 4
46.7 ft2
0
0
0.75
0
9 4
177.3 ft2
0
0
0.75
0
9 4
39Z0 ft2
0
0
o.75
0
9 4
205.3 ft2
0
0
0.75
0
9 4
214.7 ft2
0
0
0.75
0
9 4
205.3 ft2
0
0
0.75
0
# Omt Door Type Space Storms U Value Width Height Area
Ft In Ft In
1 N Wood MAIN None 2 .1 .1 .1 ft2
WINDOWS
V #
Ornt
Wait
ID
Frame
Panes
NFRC
U-Factor SHGC
1
N
1
Metal
Single (Clear)
Yes
0.79
0.49
2
N
1
Metal
Single (Clear)
Yes
0.79
0.49
3
N
1
Metal
Single (Clear)
Yes
0.79
0.49
4
E
2
Metal
Single (Clear)
Yes
0.79
OAS
5
E
2
Metal
Single (Clear)
Yes
0.79
0AS
6
E
2
Metal
Single (Clear)
Yes
0.79
0.49
7
S
3
Metal
Single(Clear)
Yes
0.79
0.49
8
S
3
Metal
Single (Clear)
Yes
0.79
0.49
9
S
3
Metal
Single (Clear)
Yes
0.79
0.49
10
S
3
Metal
Single (Clear)
Yes
0.79
0.49
11
W
4
Metal
Single (Clear)
Yes
0.79
0.49
12
N
5
Metal
Single (Clear)
Yes
0.79
0.49
13
S
7
Metal
Single (Clear)
Yes
0.79
0.49
14
S
7
Metal
Single (Clear)
Yes
0.79
0.49
15
W
8
Metal
Single (Clear)
Yes
0.79
0.49
16
N
9
Metal
Low-E Single
Yes
0.79
0.49
V
N
9
Metal
Low E Single
Yes
0.79
0.49
Overhang
Area
Depth
Separdo
96.0ft2
10ft01n
6ft0in
36.0ft2
10ft0in
6ROIn
15.0ft2
0ftOln
6ft0in
4.0ft2
10ft01n
6ft01n
15.0ft2
10ftOin
6ftOin
20.0ft2
10ft0in
6it01n
15.0ft2
10ft0in
6ft0in
9.0fF
10it0in
6It0in
36.0ft2
10ft0in
6ft0in
48.0ft2
10R0in
6ft01n
20.0 ft2
10 It 0 in
6 ft 0 In
48.0ft2
10ft0in
6ft0in
36.0ft2
10ft0in
6ft0in
9.0fF
10ft01n
6ftOin
20.0ft2
10ft0in
6ft0in
24.0ft2
2ft0in
6ftOin
20.0ft2
2ftOin
6ft0in
Int Shade Screening
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
Drapesiblinds
Exterior 5
Drapesiblinds
Exterior
11/30/2015 7:29 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6
WINDOWS
Orientation shown is the entered. Proposed orientation.
#
wall
Omt ID Frame Panes
NFRC
Overhang
U-Factor SHGC Area Depth Separation Int Shade
Screening
18
S 11 Metal Low-E Single
Yes
0.79 0.49 MOW 2 ft 0 in 6 ft 0 in Drapesiblinds
EbWor 5
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse ProposedACH(50)
.000286
2636.3 144.73 272-18 2087 5
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity Block
Ducts
1
2
3
Electric Strip Heat
Electric Strip Heat
Electric Heat Pump
None
None
None
COPA 27 kBW&r 1
COPA 17 kBbAr 2
HSPF:10 17 kBtu/hr 3
sys#1
sys#2
Ductless
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
2
3
Central Unit
Central Unit
Central Unit
None
None
None
SEER:16 42 kBhubr 1260 cfrn 0.75 1
SEER:16 18 kBtu1hr 540 cfm 0.75 2
SEER: 20.5 12 kBW/hr 360 cf n 0.75 3
sys#1
sys#2
sys#0
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
MAIN
0.92 40 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model* Collector Model # Area Volume
FEF
None None
ft=
DUCTS
#
— Supply—
Location R Value Area
— Return — Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT ON RLF
HVAC #
Heat Cool
1
2
Attic 6 175 fF
Attic 6 150ft'
Attic
Attic
18 ft' Default Leakage Attic (Default) c(Default) c
ibfi= Default Leakage Attic (Default) c(Default) c
1 1
2 2
11/30/2015 7.29 PM EnergyGauge® USA - RaRes2010 Section 405.4.1 Compliant Software Page 4 of 6
TEMPERATURES
Programable Thermostat Y
Ceiling Fans:
Conlin Jan
Heating Jan
[[ ]] Feb
[XJ Feb
�]] Mar
[Xj Mar
r , r
[ ] Apr
[
] May
May
Jun
Jun
Jul
Jul
Au
Augj
Sep
]Oct
Q Oct
Nw
Nov
H Dec
Dec
Venting I ] Jan
IIL 11) Feb
LLL�XXIII Mar
LLLXXXIII Apr
E]
1 May
llL Jun
ltt Jul
Lll 111 Aug
L 1 Sep
Oct
Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
ScheduleType
i
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
PM
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
PM
66
68
66
68
fib
68
66
68
66
68
68
68
68
68
68
68
68
68
68
68
68
66
68
66
Heating (WEH)
AM
PM
66
68
66
68
66
68
66
68.
66
68
68
68
68
68
68
68
68
68
68
68
68
66
68
66
11/30/2415 7:29 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Complian Software Page 5 of 6
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: 526 CAMPBELL ROAD PERMIT #:
FORT PIERCE, FL,
MANDATORY REQUIREMENTS SUMMARY -See individual code sections for full details.
C�R
COMPONENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise seated.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required.
Fireplaces: gasketed doors & outdoor combustion air. Must complete
envelope leakage report or visually verify Table 402.4.2.
Thermostat &
403A
At least one thermostat shall be provided for each separate heating
controls
and cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
Building framing cavities shall not be used as supply ducts.
Water heaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies
in Table 403A.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to =
R 2 + accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation
ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawispaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of =1
& Spas
HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters
minimum thermal efficiency=78% (821/6 after 4116/13). Heat pump pool
heaters minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >10kW must be divided into
two or more stages.
Ceilings/kneewalls
405.2.1
R-19 space permitting.
I IM0/2015 7:29 PM EnergyGauge® USA - RaRes2010 Section 4054.1 Compliant Software Page 6 of 6
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD'��'
ESTIMATED'ENERGY PERFORMANCE INDEX - 70
the more efficient the home.
The lower the EnergyPerformance Index,
526 CAMPBELL ROAD, FORT PIERCE, FL,
1. New construction or ebsting
New (From Plans)
9. Wail Types
Insulation Area
a Concrete Block- Ext insul, E)derior
R=4A 3070.70 ft2Single
2. Single family or multiple family
Single-family
JY
b. NIA
R= ft1
3. Number of units, if multiple family
1
c. NIA
R= ft2
4. Number of Bedrooms
4
d. N/A
10. Ceiling Types
R= ft=
Insulation Area
S. Is this a worst case?
No
a Roof Deck (Umrented)
R=20.0 3515.00 ft=
6. Conditioned floor area (f l)
3515
b. N/A
R= ftz
R ft'
7. Windows" Description
Area11
Ducts
R ft2
a U-Factor. Sgl, Uro.79
501.00 ft2
a Sup: Attic, Ret: Attic, AH: Attic
6 175
SHGC: SHGC=0.49
b. Sup: Attic, Ret Attic, AH: Attic
6 150
b. U-Factor. N/A
ft2
SHGC:
12. Cooling systems
kBbAr Efficiency
a U-Factor. NIA
fP
a Central Unit
42.0 SEERA6.00
b. Central Unit
18.0 SEE"6.00
SHGC:
c. Central Unit
12.0 SEER20.50
d. U-Factor WA
fN
13. Heating systems
kBtu/hr Efficiency
SHGC:
a, Electric Strip Heat
27.0 COP:1.00
Area Weighted Average Overhang Depth:
8.818 f .
b. Electric Strip Heat
17.0 COP:1.00
Area Weighted Average SHGC:
0.490
c. Electric Heat Pump
17.0 HSPF:10.00
8. Floor Types
Insulation
Area
14. Hot water systems
Cap: 40 gallons
a Slab -On -Grade Edge Insulation
R=0.0
3515.00 ft2
a Electric
EF: 0.92
b. NIA
R=
ft'
b. Conservation features
a NIA
R=
f z
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which Will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:Date: lZ %/,T-
Address of New Home: City/FL Zip:! -
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software