HomeMy WebLinkAboutSewager, - H APPLICATION #:,AP1.1:03624 STATE OF FLORIDA DEPARTMENT OF HEALTH PERMIT #:56-SF-146541'5 • DOCUMENT #:..F1:909290 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL, DATE PAID.:.04/17/20.13 +,fin waz FEE PAI015.00 RECEIPT #:56-PID-2119102 APPLICANT: Jane Emmons AGENT: Jason HarflS (All About Septic Services, Inc/Jason & Elizabeth Harris) PROPERTY ADDRESS: 526 Campbell Rd Fort Pierce, FL 34950 LOT: BLOCK: SUBDIVISION: ID# : 2309432-0001-000-8 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR. -RULE AND MUST BE CORRECTED: TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [1] 1050.00 [2] [ ] [271 SURFACE WATER 398 FT [ ] (02] TANK MATERIAL Concrete [ ] [281 DITCHES 20 FT [ ] (031 OUTLET DEVICE [ ] [291- PRIVATE WELLS 80 FT [ ] (04] MULTI -CHAMBERED [ Y LNJ[ ] [301 PUBLIC WELLS N/A FT [ ] [05] OUTLET FILTER Polylok [ ] [511 IRRIGATION WELLS N/A FT [ ] [06] LEGEND 1. 01-011-03DC4 2. [ ] [321 POTABLE WATER N/A FT [ ] [07] WATERTIGHT [ ] [33] BUILDING FOUNDATIONS 7 FT [ ] [08] LEVEL [ ] [34] PROPERTY LINES 45 FT [ ] [091 DEPTH TO LID [ ] [351 OTHER N/A FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [10] AREA [1] 667 [2] SQFT [ ] [36] D.RAINFiELD COVER [ ] (111 DISTRIBUTION BOX HEADER X [ ] [371 SHOULDERS [ ] [12] NUMBER OF DRAINLINES 1. 5.00 2. [ ] [381 SLOPES [ ] [13] DRAINLINE SEPARATION [ ] [39] STABILIZATION. [ ] (14] DRAINLINE SLOPE [ ] [15] DEPTH OF COVER ADDITIONAL INFORMATION [ ] [16] ELEVATION [ ABOVE / BELOW ]BM $.00 [ ] [40] UNOBSTRUCTED AREA [ ] [171 SYSTEM LOCATION [ ] [411 STORMWATER RUNOFF [ ] [18] DOSING PUMPS ( ] [421 ALARMS [ ] [19] AGGREGATE SIZE [ ] [431 MAINTENANCE AGREEMENT [ ] [20] AGGREGATE EXCESSIVE FINES [ ] [441 BUILDING AREA [ ] [21] AGGREGATE DEPTH [ ] [451 LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL [ ] [461 FINAL SITE GRADING' [ ] [22] FILL AMOUNT [ ] [4.71 CONTRACTOR [ ] [23] FILL TEXTURE [ ] [481 OTHER [ ] [24] EXCAVATION DEPTH ABANDONMENT` [ ] [25] AREA REPLACED [ ] [491 TANK PUMPED [ ] [26] REPLACEMENT MATERIAL ( ] 1501 TANK CRUSHED & FILLED Comments: Comments are on page 2. CONSTRUCTION [ EROE / DISAPPROVED ]: FINAL SYSTEM [ APPROVED / DISAPPROVED ]; (Explanation of Violations on following page) Lucie CHD DATE.: 06/19/2013 itof Health In St. Lu 6✓ St. Lucie CHD DATE : 10/10/2013 tewoo(Department o ealth in S DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, PAC PH f)ahhocn ., a n 4 AP1103524 EID1466416 Page 2 of 3 ., STATE OF FLORIDA DEPARTMENT OF HEALTH �• ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment Comments APPLICATION #:AP1103624 PERMIT # : 56-SF-1465415 DOCUMENT #: F1909290 DATE PAID:04117/2013 FEE PAI015.00 RECEIPT # :56-PI D-2':119192 The system is sized for 3 bedrooms with a maximum occupancy of 6 persons.(2 per bedroom), for a total estimated flow of 400 9pd• Duncan Final 6121/13 DH 4016, 08109 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC EH Database v 1.0.1 AP1103524 EID1466415 Page 2 .of 3